ReleaseNote-006-CSI-1.19.0-EN(1)
ReleaseNote-006-CSI-1.19.0-EN(1)
th
Date: January 08 2018 Distribution: Internal External
Document Reference #: RN006- CS Imaging-20180108 Contact: Michel Faure / Marc Laurentin/ Sandrine Perennou
Drivers DVD associated with CS Imaging Suite 1.19.0 is DVD Drivers 1.18.0
Note: Both CS Imaging and Trophy Imaging (version for Japan only) are available on infotec website. (Menu
“Imaging software” – CS Imaging V7 - tab “Download”)
CS 3D Imaging 3.8.7
o Fixed Bugs
Incorrect oblique cross section orientation: B/L orientation remains unchanged while a flip is
observed when browsing the oblique cross section. This problem occurs only if the volume is
reformatted with the version 3.8.6.
Components’ versions - Note: the versions colored in red are new regarding previous CS Imaging Suite
Disk Imaging Window 7.0.3.7
Products
CSI Suite CS Imaging Patient Browser 7.0.23.0
v.1.19.0 CS 3D Imaging Suite 3.8.7.0
CS Restore 1.7.8.2
CS Model 1.6.1.0
CSDM Lite 4.2.20.0
Monitor 1.1.13.0
CS Film Composer 3.6.9.1
CS Mesh Converter 1.1.1.0
Ceph Tracing 1.0.28.0
CAD Manager 1.0.15
Mesh Viewer 1.0.2.1
RecBase 2 1.0.0.5
Add-ons DISDemoImageDatabase 1.5
TaskQueue DataBaseCleaner 1.0.0.0
DicomTools 1.3.3
CSDM Lite Stopper 1.0.0
DICOM Printer Driver 2.0.0.17
DICOM Printer Driver 64 bits 2.0.0.18
DotNet2.0 2.0.50727.42
CS Link 5.2.0.8-A
VDDS media Interface 1.11.0.2
DPMS integration
Disk 2/2 RVG sensors RVG 4.6.11.0
Drivers Computed radiography CR 1.3.42
v.1.18.0 Extra-oral equipment CS 8000 E 5.0.2.29-I
CS 9000 5.4.5.7
CSDIT drivers 2.1.1.1
DotNet2.0 2.0.50727.42
CSDM Lite Stopper 1.0.0
Miscellaneous
TaskQueue DataBaseCleaner 1.0.0.0
DicomTools 1.3.3
Not included in the Drivers DVD (direct download available on Infotec website)
CS 8000 PCI 4.0.1.12-C
CS 8100 2D 0.2.24.0
CS 8100 3D 1.1.10.0
CS 8100SC 0.2.215.0
Extra-oral
CS 8100SC 3D 1.0.19.0
CS 9300 2.4.4.2-B
XP XP Vista Vista Win7 Win7 Win8 Win 8.1 Win 10 Server Server Server 2008 R2
Application 64 bit 64 bit
32 bit 64 bit 32 bit 64 bit 32 bit 64 bit 64 bit 2003 2008 64bit
CS Imaging version 7 N N N N Y Y Y Y Y N N Y
CS 3D Imaging N N N N N Y Y Y Y N N N
/ Film Composer
Film composer N N Y N Y Y Y Y Y N N N
CS Restore N N N N Y Y Y Y Y N N N
CS Model N N N N Y Y Y Y Y N N N
CS Acquisition (1) N N Y N Y Y Y Y Y N N N
Trophy DICOM N N Y N Y Y Y Y Y N N N
CS 8100 Pan/3D/SC N N N N N Y Y Y Y N N N
CS 9000 Pan/Ceph/3D N N Y N Y Y Y Y Y N N N
CS 9300 Pan/Ceph/3D N N N N Y Y Y Y Y N N N
9500 3D N N Y N Y Y N N N N N N
STV/1000 Camera N N Y N Y N N N N N N N
OEM Camera N N Y N Y N N N N N N N
CS 1200/1500/1600 Camera N N Y N Y Y Y Y Y N N N
CS 3500 3D IO scanner N N N N N Y Y Y Y N N N
CS 3600 3D IO scanner N N N N N Y Y Y Y N N N
CS 3000 Milling N N N N N Y Y Y Y N N N
CS 7400 N N Y N Y Y N N Y N N N
CS 7600 N N Y N Y Y Y Y Y N N N
CS 7200 N N N N Y Y Y Y Y N N N
RELEASE HISTORY
This release of CS Imaging Software is distributed as CS Imaging Suite 1.18.0 DVD and includes the following points:
- New features
- Drivers improvements
- Bug fixes
CS Imaging 7.0.3.4
Fixed Bugs
- Ceph Tracing Unknown error occurs with cephtracing2.m when trying to trace CS 8100SC images
- Error message appears when importing multiple images from imaging software
- Error pop-up appears when you export an image to a folder having a special character (Japanese character
for example)
- Images are overwritten when file extension is upper case (Ex: R1.RVG instead of R1.rvg).
- Save pop-up doesn't appear when drag and drop panoramic image to the dental arch in Imaging software.
New Features
CS 3D Imaging 3.8.6
Fixed Bugs
New Features
- CS 3D Imaging version 32 bits (3.5.18.0) is now available in Infotec website for download (not in the CS
Imaging Suite 1.18 DVD).
- Airways Analyses.
1
Airways segmentation with a minimum of 2 mouse clicks
This release of CS Imaging Software is distributed as CS Imaging Suite 1.17.0 DVD and includes the following points:
- New features
- Drivers improvements
- Bug fixes
-
CS Imaging 7.0.2.8:
Fixed Bugs
New Features:
Cephalometric automatic tracing tool: add the possibility to perform a -/+ 90°
CS 3D Viewer 3.7.1:
Fixed Bugs
New Features
Driver CS 1200/1600 :
o Fixed bug : Win10 OS cannot be detected by Installation Wizard
This release of CS Imaging Software is distributed as CS Imaging Suite 1.16.0 DVD and includes the following points:
- New features
- Drivers improvements
- Bug fixes
-
Patient browser update & new features :
A large image preview
Applicable to Mesh objects
Exporting 3D volume enhancements,
Intraoral scanner 2D image management,
CAD/CAM
images can be
rotated
or display in a
Carousel view
It is also possible to export CAD/CAM scanned objects from the Patient Browser
(through the “Save as” function) and select the export file as STL, PLY, or the Native file
format.
Users can also select multiple images of whatever type (2D, 3D, CAD/CAM)
through CONTROL+CLICK and export them into the same folder.
Now, the Patient Browser Preferences allows users to choose and specify the
default application for opening a CAD/CAM, CS Restore, or CS Model image. In addition,
the feature adds security when deleting processes by making it an optional feature that can
be deactivated (by default).
The Imaging Window also supports CS 8100 / CS 8100 3D bitewing images, which can be inserted into a dedicated template
“PanoBitewing” from which it is possible to reposition the bitewings by panning those (one at a time or both images
simultaneously) so as to only display the meaningful elements as per a bitewing image.
Reposition the
bitewing
images
simultaneously
or one by one
Finally, the Demo toolbar is an option installed for tradeshow purposes that now includes the CS 8100 product range.
The Demo toolbar is not available in the list during the CS imaging suite installation.
However, you can install it manually from the DVD in the folder “Support\Tools”
New features:
- Improved tissue identification
- Implant planning report
- Unique Device Identifier (UDI)
Improvements:
- Select corresponding item in the object list when picking an object in a 2D view
- Warn user of mix-up when different patients are exported to the same media
- Use US letter templates by default for USA, Canada and Mexico
- Preserve transversal slice measurement when centering on an object
- Update US print templates (including single view, 4 views and curved)
- Update English Online help
- Prevent application from crashing when loading very large volumes
- Use the top of the implant as the reference point when replacing an implant
Fixed Bugs:
- 3D rendering of low dose acquisition is not always good
- Bad 3D view: amalgam algorithm error
- Bad 3D rendering for CS 8100 3D on 5x5 acquisitions
- Custom thickness for panoramic view does not apply when the thickness for other views is set to native resolution
Note: If you install this 3D suite version on a 32 bits OS, it will uninstall the previous 32 bits version and not installed the 3D suite 64
bits
Fixed bugs:
Fixed bugs:
- Header cannot be saved when creating a frame near to edge of header
- FilmComposer version 64 bit is not blacklisted on OS version 32 bit
- Film Composer error when print to PACS
- Implant report templates cannot be edited
RVG Driver 4.9.11.0
- Support RVG 142
This new RVG driver doesn’t support RVG 5 USB , RVG 5000 and RVG 6000 anymore
Fixed bugs
o IPET is considered as a virus, then blocked and deleted by AntiVirus
CS RESTORE 1.7.8.2:
o Fixed bugs :
o The margin line drawn in the acquisition software 3600 is not shown in the CS Restore
New Patient Browser replaces the previous Patient File of Dental Imaging Software (DIS).
It allows user to search for any patient quickly by using the patient search engine.
User can now see all of a patient’s images in the integrated image gallery.
User can launch the extra-oral image acquisition interface directly.
User can even manage image files for export/import/printing, as well as drag & drop images for export.
The Imaging Window of CS Imaging is directly issued from Carestream’s Dental Imaging Software (DIS). It ensures to the user a smooth
transition from Carestream’s Dental Imaging Software (DIS) to CS Imaging version 7.
New intuitive icons now share the same icon design with all other CS software solutions.
These new icons simplify the transition by maintaining the same icon location as in DIS.
The new stylish black radiographic background enhances the user’s diagnostic experience by highlighting the images in
front of a black background. It intensifies the details of the images. Details of the images can furthermore be highlighted
by a large choice of filters.
With CS Imaging, users can manage and analyze a vast array of digital images while using the same workflow or tools
as in DIS.
All of these features minimize the amount of user disruption when transitioning from DIS to CS Imaging version 7.
New features
When CS imaging version 7 is used in association with CS Acquisition, CS Acquisition must be upgraded in
version 1.0.30 minimum
New features
o New German DIN standard support in the service tools
o Window 10 compatibility
New features
o New German DIN standard support in the service tools
o Windows 10 compatibility
o QAT artifact checking during QAT 3D control in service tools
o Possibility to restore the old Task Queue rendering (KDIS version). This allows to not changing the
preferences of the customer when the driver is updated. In order to get the old rendering, you have to
open the Registry Editor of the acquisition computer and then create a DWORD “filter” in
HKLM/SOFTWARE/Classes/Trophy/PANO and set the value to 4
o CS Adapt is supported by the TWAIN driver
o It is possible to modify the dose factor (For panoramic modality only) of the unit from 0.7 to 1.3 in the
technical acquisition menu (see screen shoot below) This factor must be modifying regarding a Kerma
surface measurement.
Fixed bugs
o Panoramic acquisitions without X-ray stop during acquisition without error
o Increase the size of log files from 1MB to 5MB
o QAT test result failed even if all test passed
New features
o Add a dose factor value in the technician menu for kerma surface measurement (idem as shown in CS
9000 section)
Fixed bugs
o 9300 driver very slow to load when launching acquisition GUI
o Line pair reference in acceptance/constancy test for ceph should be reduced back to 2.5 because of
QS Guideline regulatory
o QAT test result failed even if all test passed
Fixed bugs
o Images displayed in wrong order with DEXIS using Twain driver
CS 8100 FAMILY:
The CS 8100/8100 3D/8100SC drivers are not included in the DVD Drivers. Each driver will be included in the product
packaging.
Fixed bugs
New features
o Windows 10 Support
o Custom rendering presets (Japan only)
o Default thickness for 2D views
o Add new options to the list of supported slice thickness with Volume convertor
o Display of the patient sex and date of birth
Fixed bugs
o Windows 10 support
o Windows 10 support
o Fixed FMS out of order issue by update plug-in software
CS 8000Ethernet driver 5.0.2.29-B :
o Driver now available on DVD Drivers
CS 8100 Family:
o The CS 8100/8100 3D/8100SC drivers are not included in the DVD Drivers. Each driver will be
included in the product packaging.
New features
o Windows 10 Support
Fixed bugs
NA
New features
Note 1: If you upgrade CS 3000 Software to latest version (0.2.0.4), you must install this new CS Restore release
1.6.6-B. It is the only one for now compatible with the CS 3000 Software 0.2.0.4.
o Mesh Viewer
o DIS
Customers who have upgraded their 8000 PCI to 8000 Ethernet with the PCI converter box have now the possibility to
choose between the 8000 PCI and the 8000 Ethernet processing’s.
This choice has to be made in the DIS Preferences by activating or deactivating the new option:
Fixed bugs
CS 3D Imaging
- The “Flip” button is no longer present on the toolbar for RVG, CRIO and CRPano images.
- Sometimes, an angle calculated during the ceph auto tracings is the opposite one.
- After having modified a patient name, the name is not modified on the radiological log.
- Optimization of the CS Adapt presets loading time
- In the case of a first DIS installation, the CS Adapt information message popup is not displayed after a first
acquisition.
- Extra-oral images are set with teeth numbers when inserted sometimes in a FMS.
- Ceph images saved as “new image” or acquired in DIS after launching a first time the Report are not listed in
the “List” tab of the patient history.
- Delete an image inserted in a FMS will cause DIS to crash in some cases.
- When deleting a ceph image, the associated tracing file is not deleted.
- Error message when using or changing favorite CS Adapt filters when the user was not logged as
administrator.
- Patient selection window comes forward after a camera acquisition.
CS 8100 3D
- Better management of the Twain.csv log file to prevent it from increasing too much.
CS 9300 Family
- Better management of the Twain.csv log file to prevent it from increasing too much.
- Integration of the latest Hasp key drivers to fix blue screen issues that could occur during installation.
New features
- CS Adapt Filters available for all extra-oral products except CS 8000 unit - Refer to
PN368_CS_Adapt_Release
- CS Mesh Viewer in stand-alone: must be installed manually from DIS Suite Tools folder
Fixed bugs
Drivers Improvements
- Add by default in the Film Composer the template FMS 1to1 8x10 (in attachements) (only as FMS template
for DIS)
- Refer to PN00368_CS Adapt_release for CS 9x00_ CS 8100
- PN00370_RVG6200_CSAdapt
Fixed bugs
- The FMS is not saved even if the automatic save of new image and modification are checked in the
preferences.
- Set "Institution Address" in DIS options.
- Need to display Teeth numbers for 3D meshes.
- Store a video on DIS with the import.
- Save as "Same file" was enabled by default when importing a digital camera image.
- Ceph Contextual Menu on images showed angle value without any unit.
- CS 7200 applications was still running after a force to close DIS.
- A measure defined during calibration was not saved when the image is closed.
- Image Export - Multiple Tif choices (standard Tiff, Tiff-Cmp, Exif, Exif-Jpeg)
- The Radiological Log journal is not well updated after acquisitions with a Japonese OS.
- Only one image was sent to FilmComposer when using the image multi selection feature.
- Wrong behavior when importing old FMX tif file taken with TW 5.
- Image will be duplicated when the user inserts the image into FMS in DIS.
- Import an image into DIS and then save it with another date, displayed the old date when importing image.