Fdmiu
Fdmiu
Fdmiu
Fdmiu
Fdmiu
MECH. INSP.
B. Referenced Information
REFERENCE DESIGNATION
Ref. Energize the Aircraft Electrical Circuits from
24-41-00-861-002-A the External Power
Ref. Energize the Aircraft Electrical Circuits from
24-41-00-861-002- the APU
A01
Ref. Energize the Aircraft Electrical Circuits from
24-41-00-861-002- Engine 1(2)
A02
Fdmiu
MECH. INSP.
REFERENCE DESIGNATION
Ref. Printout of the Engine/APU Hours and
31-36-00-740-015-A Cycles Stored in the Flight Data Interface
and Management Unit (FDIMU)
3. Job Set-up
** ON A/C FSN 252-400, 451-500, 551-850, 906-907, 910-910, 915-916,
919-999
PRE SB 31-1522 for A/C 252-255
SUBTASK 31-36-00-860-126-D
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
Ref. AMM TASK 24-41-00-861-002.
(2) Do the print out of the engine and APU hours and cycles Ref.
AMM TASK 31-36-00-740-015.
Fdmiu
MECH. INSP.
Fdmiu
MECH. INSP.
ACTION RESULT
On the overhead panel, on On the DLS display:
the Data Loading Selector
(DLS):
- Put the ON/OFF - The DB/N:XXXXXXXX
switch to the ON and PUSH NEXT/
position. PREV indications show.
- Push the NEXT or - The AIDS NOT
PREV key until the SELECTED indication
AIDS NOT shows.
SELECTED indication
shows on the display.
Fdmiu
MECH. INSP.
ACTION RESULT
- Put 10TVMD2 with - These indications show
10TVSW2 into the in a short time:
MDDU. It is necessary READY
to load all disks until WAIT RESPONSE
the loading process is TRANSF IN PROG.
completed.
Fdmiu
MECH. INSP.
ACTION RESULT
- Close the floppy-disk
access door.
On the DLS panel: On the DLS display:
- Push the SEL CTL - The AIDS NOT
key. SELECTED indication
shows.
ACTION RESULT
On the MCDU: On the MCDU display:
- Push the line key adjacent - The AIDS page comes into
to the AIDS indication. view.
- Push the line key adjacent - The AIDS:SPECIAL FUNC/
to the REPROG page comes into
REPROGRAMMING view.
indication.
Fdmiu
MECH. INSP.
ACTION RESULT
- Push the line key adjacent - The AIDS:DOCUMENTARY
to the DOC DATA DATA page comes into
indication. view.
- Make sure that the FDIMU
software part-number and
FDIMU hardware part-
number are correct.
- Push the line key adjacent - The AIDS:SPECIAL FUNC/
to the RETURN indication. REPROG page comes into
view.
- Push the line key adjacent - The AIDS page comes into
to the RETURN indication. view.