PN014A-03_EN-GB
PN014A-03_EN-GB
Product characteristics
Number of inputs and outputs Number of digital outputs: 2
Measuring range -1...10 bar -14.5...145 psi -100...1000 kPa -0.1...1 MPa
Process connection threaded connection G 1/4 internal thread
Application
Special feature Gold-plated contacts
Application for industrial applications
Media liquids and gases
Medium temperature [°C] -20...60
Min. bursting pressure 150 bar 2175 psi 15 MPa
Pressure rating 75 bar 1087 psi 7.5 MPa
Type of pressure relative pressure; vacuum
Electrical data
Operating voltage [V] 18...36 DC; (to SELV/PELV)
Current consumption [mA] < 50
Protection class III
Reverse polarity protection yes
Overvoltage protection yes; (< 40 V)
Power-on delay time [s] 0.3
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2
Outputs
Total number of outputs 2
Output signal switching signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching [V]
2
output DC
Permanent current rating of [mA]
250
switching output DC
Switching frequency DC [Hz] < 170
Short-circuit protection yes
Type of short-circuit
pulsed
protection
Measuring/setting range
Measuring range -1...10 bar -14.5...145 psi -100...1000 kPa -0.1...1 MPa
Set point SP -0.9...10 bar -12...145 psi -0.09...1 MPa
Reset point rP -0.95...9.95 bar -13...144 psi -0.095...0.995 MPa
In steps of 0.05 bar 1 psi 0.005 MPa
Factory setting SP1 = 2.50 bar rP1 = 2.30 bar
SP2 = 7.50 bar rP2 = 7.30 bar
Accuracy / deviations
Switch point accuracy
< ± 0,5
[% of the span]
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation
< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
[% of the span]
Hysteresis deviation
< ± 0,25
[% of the span]
Long-term stability
< ± 0,05; (per 6 months)
[% of the span]
Temperature coefficient zero
point 0,2; (0...60 °C)
[% of the span / 10 K]
Temperature coefficient span
0,2; (0...60 °C)
[% of the span / 10 K]
Response times
Delay time programmable dS, [s]
0; 0,2...50
dr
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; diagnostic function;
switching logic; switch-on/switch-off delay; Damping; Display unit
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
Electrical connection
Connector: 1 x M12; coding: A; Contacts: gold-plated