0% found this document useful (0 votes)
10 views

kslore

This document is a quick installation guide for the 5G Pro Inverter, detailing error codes, installation requirements, and specifications. It emphasizes the importance of proper grounding, cable connections, and safety precautions during installation. Additionally, it includes contact information for customer service and support.

Uploaded by

infosolarbni
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views

kslore

This document is a quick installation guide for the 5G Pro Inverter, detailing error codes, installation requirements, and specifications. It emphasizes the importance of proper grounding, cable connections, and safety precautions during installation. Additionally, it includes contact information for customer service and support.

Uploaded by

infosolarbni
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Since 2012

QUICK INSTALLATION GUIDE


5G PRO INVERTER
KSY:- 1KW- 4KW /4.4KW 1MPPT
Single-Phase Grid-tied Solar Inverter
3.6 5G Pro Error Codes QUICK INSTALLATION GUIDE
Error Code Error Code
1KW -4.4KW 1 MPPT-Single Phase
5 PV Voltage too high 1. Product Overview :
6 Surface insulation resistance error (DC Leakage) 1. LCD & LED or LED

Ground Fault circuit interruoter(GFCI) exceeds the


2. PV Terminal (s)
7 Permissible range 3. Wi-Fi/Stick (Optional)
8 Inverter temperature too high 5. AC Terminal / Cable
6. Second PE Terminal
9 Utility grid disconnected (Grid Voltage Unavailable)

10 Grid voltage exceeds the permissible range 2 3 5 4


11 Grid Frequency exceeds the permissible range Dimension : W x H x D = 297 x223X117mm

15 Bus-voltage too high 2. Packing List


16 Bus-voltage too low
19 N-PE Voltage too high

NOTICE : Make sure the cover & the communication cable gland has been mounted properly & adequately
INVERTER MOUNTING DCPLUGS AC CONNECTOR METER COMMUNICATION DOCUMENTS
ACCESSORIE (SEALED) or Wire CONNECTOR WARRANTY
4. Commissioning
DATALOGGER
OR RS 485 CARD & TR
(OPTIONAL)
CONNECTOR

Please check if 1 1 1pair 1 1 1 1


1. The inverter and mounting Screw/bracket have been correctly installed.
2 The inverter's exposed metal surface has a ground connection. 3. Installing
3. The resistance between PV arrays and ground is greater than 1Mohm. Installation Requirements
4 For any unused DC terminals there are DC connectors inserted to the terminal and 1.Please install the inverter(s) in places that
sealed with waterproof caps. can avoid inadvertent contact.
5. The grid voltage at the point of connection of the inverter is within the permitted range. 2.Please install he inverter on solid/ smooth
surfaces.
6. The AC circuit breaker must be correctly rated and wired
3.The inverter(s) should not be installed near

QUICK INSTALLATION GUIDE


7. The cable communication connectors have been correctly wired and tightened. inflammable or explosive objects.
8. Canopy has to be Installed over the Inverter.

Startup Avoid
5GSwitch
PRO INVERTER
on the DC after finishing the above checks, then switch on the AC circuit
breaker When there is sufficient DC power applied and the grid conditions are met, the inverter
will start to operate automatically

Ksolare Energy Private Ltd. Factory & Marketing Office Ksolare Technology Park Sr.No.62,
Hissa No.03, Mangdewadi, Pune-Satara Road, Katraj, Pune-411046. (MH-India)
Service: 8530111222
www.ksolare.com KSY -1KW - 4.4KW USER MANUAL 1
Specification
No. Item Type Specifications Notice
1 PE Cable Single-core outdoor copper cable Conductor cross-section: 4-6mm 2 Proper Grounding connection of the second PE terminal and the AC terminal is mandatory. NOT properly connecting both PE will void all product warranty.

2 AC Output cable Outdoor copper cable Cross-section:2.5-4 mm 2


/Connector Cable outer diameter: 5.5-12.5 mm
3.4 AC Wire Assembly & Connection
3 DC Intput cable Standard outdoor PV cable, PV1-F Conductor Cross-section:2.5-6 mm 2 DANGER
Model recommended Cable outer diameter: 5-8 mm
Danger to life due to High Voltage in the Inverter.
Before connecting any electrical wires & components, please ensure the DC Switch & AC circuit breaker are switched OFF & cannot be reactivated.
4 Meter/RS485 Two-core outdoor shielded twisted Conductor Cross-section:0.14-1.0 mm 2
pair cable Cable outer diameter: appox. 6 mm
Note: Please Ensure that the connector has been correctly installed!
CAT - 5E, outdoor shielded cable Cable outer diameter : apporex 9 mm
5 DRED
Standard for EIA/TIA 568B Cable maximum length 1000m 3.4 DC Wire Assembly & Connection
3 Mounting Meeting the following requirements is mandatory. All warranty rights will otherwise be invalid.
1. Use the Heatsink bracket holes as a template and mark the drill holes 10mm diameter & 3.3.1 Maximum open circuit voltage of each string is less than 500V/550V
70mm depth 3.3.2 Maximum short circuit current of each PV input is less than inverter allowable limit.
2. Fix the Inverter with the screws and expansion bolts packed in mounting accessories 3.3.3 The string is well insulated to ground in all cases.
3. Check both sides of the heat sink to ensure the inverter is stably attached. 3.3.4 Make sure that the DC connectors have the correct polarity.
2 3.3.5 If the PV connectors are not assembled properly & locked into place, arc or overheat may be induced.
125 mm

Installing the PE cable


A second PE terminal is equipped at the bottom of the inverter. /550V

Ensure the PE terminal is terminal is reliably grounded & the


grounding resistance is less than 10 Ohm.
3.5 Wi-Fi/ GPRS Connection (Optional)
Object Description The Stick is included in the scope of delivery as an option.
1 Housing 3.4.1 Tighten the stick into the COM1 port. Make sure the
2 M5 terminal lug with protective conductor stick is securely connected.
3 M 5x13 pan head screw 3.4.2 For the connetion & configuration of the stick please

Tighten it firmly into the housing (T25 screwdriver, torque:2.5Nm).


refer to <Wi -Fi stick User manual>

KSY -1KW - 4.4Kw USER MANUAL 2 KSY -1KW - 4.4KW USER MANUAL 3
Panel Configuration

S.N Capacity Panels Qty Connection Y connector Strings

1 3kW 1ph 540wp /530wp 6nos. 1 in 1 out No 1


2 3.4kW 1ph 540wp /530wp 7nos. 1 in 1 out No 1
3 4.2kW 1ph 540wp /530wp 8nos. 1 in 1 out No 1

Contact :- 8530111222/
7030955502/703095507
DO's & Don'ts:
String configuration according to DS
 Cable size and type selection should be accurate (mostly copper)
MC4 crimping- proper & other accessories

Polarity check
> DC/AC voltage check using DMM
Proper ventilation
If installing outside please prefer canopy for extra safety
Proper Earthing
Use extra protections (AC side MCBs & DC fuses) for maintenance
Fuse & MCB ratings selection should be proper
Don't do parallel connection in DCDB
Check DC leakage of stungs
Sr.No. 3, KSolare Technology Park, 7/B/1/4, opp.
Hotel Royal Sahyadri, near Poonam petrol pump, Mangdewadi,
Pune, Maharashtra 411046

Service Email: [email protected]