NOTICE : Make sure the cover & the communication cable gland has been mounted properly & adequately
INVERTER MOUNTING DCPLUGS AC CONNECTOR METER COMMUNICATION DOCUMENTS
ACCESSORIE (SEALED) or Wire CONNECTOR WARRANTY
4. Commissioning
DATALOGGER
OR RS 485 CARD & TR
(OPTIONAL)
CONNECTOR
Startup Avoid
5GSwitch
PRO INVERTER
on the DC after finishing the above checks, then switch on the AC circuit
breaker When there is sufficient DC power applied and the grid conditions are met, the inverter
will start to operate automatically
Ksolare Energy Private Ltd. Factory & Marketing Office Ksolare Technology Park Sr.No.62,
Hissa No.03, Mangdewadi, Pune-Satara Road, Katraj, Pune-411046. (MH-India)
Service: 8530111222
www.ksolare.com KSY -1KW - 4.4KW USER MANUAL 1
Specification
No. Item Type Specifications Notice
1 PE Cable Single-core outdoor copper cable Conductor cross-section: 4-6mm 2 Proper Grounding connection of the second PE terminal and the AC terminal is mandatory. NOT properly connecting both PE will void all product warranty.
KSY -1KW - 4.4Kw USER MANUAL 2 KSY -1KW - 4.4KW USER MANUAL 3
Panel Configuration
Contact :- 8530111222/
7030955502/703095507
DO's & Don'ts:
String configuration according to DS
Cable size and type selection should be accurate (mostly copper)
MC4 crimping- proper & other accessories
Polarity check
> DC/AC voltage check using DMM
Proper ventilation
If installing outside please prefer canopy for extra safety
Proper Earthing
Use extra protections (AC side MCBs & DC fuses) for maintenance
Fuse & MCB ratings selection should be proper
Don't do parallel connection in DCDB
Check DC leakage of stungs