0% found this document useful (0 votes)
22 views24 pages

8S202 R- LEVEL SWITCH

This document is a working drawing for a drills ship (Ship No. HN1911/12) owned by Seadrill, detailing specifications and assembly drawings for various level switches. It includes a parts list, specifications for side and top mounting types, and service life information. The document outlines the application models, operating principles, and includes tables for different level switch models and their respective tank applications.

Uploaded by

Bruno Oliveira
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
22 views24 pages

8S202 R- LEVEL SWITCH

This document is a working drawing for a drills ship (Ship No. HN1911/12) owned by Seadrill, detailing specifications and assembly drawings for various level switches. It includes a parts list, specifications for side and top mounting types, and service life information. The document outlines the application models, operating principles, and includes tables for different level switch models and their respective tank applications.

Uploaded by

Bruno Oliveira
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 24

WORKING DRAWING

Owner SEADRILL

Ship Yard SAMSUNG HEAVY INDUSTRIES

Ship No. HN1911/12


DAEHWA
ENGINEERING
Ship Type DRILLSHIP

IMO. No.

Item LEVEL SWITCH

4 2012. 05. 03 for Re-Working


3 2012. 03. 22 for Working
2 2012. 01. 03 for Re-Approval
1 2011. 04. 06 for Approval
No. Date Description
Contents 2

Ship No. : H1911/12


No. Name of Drawing Drawing No. Page Description Rev. No.

1 MAKER SUPPLY PARTS LIST 3

SPECIFICATION
2 4
(Abbreviation & Name plate)

3 SPECIFICATION 5 SIDE MOUNTING TYPE

4 SPEC. TABLE 6 "

5 ASSEMBLY DRAWING DX005S-L 7 "

6 " DX005S-H 8 "

7 SPEC. TABLE 9

8 ASSEMBLY DRAWING DX005S-H-10 10 "

9 " DX005S-L-10 11

10 SPECIFICATION 12 TOP MOUNTING TYPE

11 SPEC. TABLE 13 "

12 ASSEMBLY DRAWING DX007S-1FT 14 "

13 " DX007S-1FT-3 14-1 "

14 SPEC. TABLE 15, 16 "

15 ASSEMBLY DRAWING DX007S-1FTS-9 17 "

16 SPEC. TABLE 18 "

17 ASSEMBLY DRAWING DX007S-2FTn 19 "

18 SPEC. TABLE 20 "

19 ASSEMBLY DRAWING DX007S-1FTEx-2 21 "

20 SPARE PARTS LIST 22

Specification

.
Dwg. Dsg. Chk. Chief

S
DAEHWA ENGINEERING
Maker Supply Parts List 3

Ship No. : H1911/12


Name Wgt. Quantity
Sketch Model Remarks
Dwg. No. (kg) 1 Ship
LEVEL
SWITCH
DX005S-L 2.8 8 LS-SM-D3-ST Side Mounting Type
DX005S-H 10 * With Testing Device
* With Gasket

LEVEL
SWITCH
DX005S-L-10 3.5 3 LS-SM-D3-DF Side Mounting Type
DX005S-H-10 * With Testing Device
* With Gasket

LEVEL
SWITCH
DX007S-1FT 5.5 11 LS-TM-1FT Top Mounting Type
DX007S-1FT-3 9 * With Testing Device
10 * With Gasket

LEVEL
SWITCH
DX007S-1FTS-9 5 21 LS-TM-1FT Top Mounting Type
* With Testing Device
* With Gasket

LEVEL
SWITCH
DX007S-2FTn 6 8 LS-TM-2FT Top Mounting Type
11 * With Testing Device
* With Gasket

LEVEL
SWITCH
DX007S-1FEx-2 5 8 LS-TM-Exd Top Mounting Type
7 * With Testing Device
* With Gasket

DAEHWA ENGINEERING
4
Specification
( Abbreviation & Name Plate )

■ Abbreviation of Alarm / Control


The abbreviations of alarm / control symbols in the drawing are as follows.
L A H : High Level Alarm
L A L : Low Level Alarm
L C H : High Level Control
L C L : Low Level Control
F A H : High Flow Alarm

■ Name Plate
1) Drawing of name plate

Level S/W Tag No. LAL-3923


20
Description M / E C. F. W EXP. TK

65

2) Material : Stainless steel


3) The name plate for each level switch will be attached by riveting on the connection flange.

LS-SM TYPE LS-TM TYPE


Name Plate

DAEHWA ENGINEERING
5
Specification
( Side Mounting Type )

■ Specification
Application Model : LS-SM Max. Working Pressure : 5kg/㎠
Class : GL, KR, DNV, BV, LR, RINA, NK Max. Working Temp. : 120℃
Units : METRIC Min. SP/GR : 0.6
IP Rating : 56 Insulation Resistance : 100㏁ Min. AT 500DC
Switch Capacity : AC 125V 15A, AC 250V 15A, Dielectric Strength : 1000V AC 50/60Hz
DC 30V 6A for 1 Minute

■ Service Life
Mechanical Operations : Min. 1,500,000
Electrical Operations : Min. 1,000,000 at Switching Current

■ Operating Principle
A permanent magnet is fitted at the end of float arm which is located inside of tank And another
magnet is connected to the micro switch lever in the terminal box located outside of the tank. The
float moves up and down with liquid level in the tank. As the float reaches a certain level, the
micro switch is actuated by reacting operation caused by magnetic force.

LS-SM

DAEHWA ENGINEERING
Spec. Table for Level Switch 6

Ship No. : HN1911/12 MODEL : LS-SM-D3-65A Side Mounting type

Length Cable Drawing Conn. Enclosure Yard P & ID


No. Tag No. Tank Name Function Q'ty Position Remark
(L) No. Flange ( IP ) Cable no. Page no.
Gland

1 LAL-021601 FWD A/M C.F.W EXP TK LEVEL LAL 1 283 20A DX005S-L 5K-65A 56 AAM-68-002 L051 S28

2 LAL-022601 NO.2 TH C.F.W EXP TK LEVEL LAL 1 283 " DX005S-L 5K-65A 56 AAM-66-009 L052 S29

3 LAL-023601 NO.3 TH C.F.W EXP TK LEVEL LAL 1 283 " DX005S-L 5K-65A 56 AAM-66-018 L053 S29

4 LAL-063201 PORT E/R C.F.W EXP TK LEVEL LAL 1 283 " DX005S-L 5K-65A 56 AAM-59-010 L048 S25

5 LAL-063206 CENT E/R C.F.W EXP TK LEVEL LAL 1 283 " DX005S-L 5K-65A 56 AAM-61-007 L049 S26

6 LAL-063211 STBD E/R C.F.W EXP TK LEVEL LAL 1 283 " DX005S-L 5K-65A 56 AAM-63-011 L050 S27

7 LCH-072101 D.O SERVICE TANK ( P ) LEVEL CONTROL LCH 1 283 " DX005S-H 5K-65A 56 AAM-58-024 L009 S6 added

8 LCH-072103 D.O SERVICE TANK ( S ) LEVEL CONTROL LCH 1 283 " DX005S-H 5K-66A 56 AAM-62-023 L007 S6 added

9 L.O SETTLING TANK ( P ) LCL 1 283 " DX005S-L 5K-65A 56 3P-13-005 L-095 S13 added

10 L.O SETTLING TANK ( S ) LCL 1 283 " DX005S-L 5K-65A 56 5P-14-005 L-096 S15 added

DAEHWA ENGINEERING
C.G :15B(cable o.d:10.3)
C.G :20A(cable o.d:11.5)
C.G :20B(cable o.d:12.7)
Spec. Table for Level Switch 9

Ship No. : HN1911/12 MODEL : LS-SM-D3-DF Side Mounting type

Length Cable Drawing Conn. Enclosure Yard Position P & ID


No. Tag No. Tank Name Function Q'ty Remark
(L) No. Flange ( IP ) Cable no. (Boss No.) Page no.
Gland

1 FAH-071108 PORT E / R D.O OVERFLOW FAH 1 100 20A DX005S-H-10 5K-65A 56 AAM-59-004 L026 S6

2 FAH-071117 STBD E / R D.O DRAIN FLOW FAH 1 100 " DX005S-H-10 5K-65A 56 AAM-63-004 L028 S6

3 LAL-091308 F.W TANK FOR LOCAL FIRE FIGHTING LAL 1 100 " DX005S-L-10 5K-66A 56 AFF-11-010 L002 S1

DAEHWA ENGINEERING
C.G :15B(cable o.d:10.3)
C.G :20A(cable o.d:11.5)
C.G :20B(cable o.d:12.7)
12
Specification
( Top Mounting Type )

■ Specification
Application Model : LS-TM Max. Working Pressure : 5kg/㎠
Class : GL, KR, DNV, BV, LR, RINA, NK Max. Working Temp. : 120℃
Units : METRIC Min. SP/GR : 0.6
IP Rating : 56 Insulation Resistance : 100㏁ Min. at 500DC
Switch Capacity : 50VA Dielectric Strength : AC 350V, 50/60Hz
for 1 Minute

■ Service Life
Electrical Operations : Min. 400,000,000 at Switching Current

■ Operating Principle
As shown in the drawing below, permanent magnets are fitted inside of the float. The float moves
up and down along the guide pipe which is made of stainless steel. Two sets of reed switches are
installed inside of the guide pipe. As the float reaches a certain level, the reed switch is actuated by
magnetic force.

LS-TM

NORMAL ALARM

In Case of B-Contact (Normally Closed)

DAEHWA ENGINEERING
Spec. Table for Level Switch 13

Ship No. : HN1911/12 MODEL : LS-TM-1FT-100A Top Mounting type


Length Cable Enclosur Contact
Drawing Conn. Yard Position P & ID
No. Tag No. Tank Name Function Q'ty e Remark
No. Flange Cable no. (Boss No.) Page no.
A C E Gland ( IP ) Comp.

1 LAH-051105 DO PURI SLUDGE TANK ( P ) LEVEL LAH 1 250 - 150 20A DX007S-1FT 5K-100A 56 nc AAM-58-015 L020 S7

2 LAH-051115 DO PURI SLUDGE TANK ( S ) LEVEL LAH 1 250 - 150 " DX007S-1FT " " nc AAM-62-019 L021 S7

3 LAH-072201 PORT E / R L.O DRAIN TK LEVEL LAH 1 250 - 150 " DX007S-1FT " " nc AAM-59-022 S13

4 LAH-072203 STBD E / R L.O DRAIN TK LEVEL LAH 1 250 - 150 " DX007S-1FT " " nc AAM-63-010 S15

5 LAH-081103 FWD AUX. MACH. RM BILGE HOLD TK LEVEL LAH 1 250 - 150 " DX007S-1FT " " nc AAM-65-014 L088 S46

6 LAH-081131 BOSUN STORE ( P ) BILGE LEVEL LAH 1 450 - 350 " DX007S-1FT " " nc AAM-65-002 32 ( 2 / 3 )

7 LAH-081132 BOSUN STORE ( S ) BILGE LEVEL LAH 1 450 - 350 " DX007S-1FT " " nc AAM-65-003 32 ( 2 / 3 )

8 LAH-081144 HPU ROOM BILGE LEVEL LAH 1 400 - 300 " DX007S-1FT " " nc AAM-57-007 S45

Type changed to
9 LAH-052107 L.O PURI SLUDGE TANK ( P ) LEVEL LAH 1 - " DX007S-1FT " " nc AAM-59-023 L042 S13
page 18
Type changed to
10 LAH-052114 L.O PURI SLUDGE TANK ( C ) LEVEL LAH 1 - " DX007S-1FT " " nc AAM-61-004 L044 S14
page 18
Type changed to
11 LAH-052121 L.O PURI SLUDGE TANK ( S ) LEVEL LAH 1 - " DX007S-1FT " " nc AAM-63-009 L046 S15
page 18
Type Chnaged
9 LAH-081146 CENT VOID SPACE BILGE LEVEL LAH 1 320 - 250 " DX007S-1FT " " nc AAM-56-007 32 ( 1 / 3 )
from page 20

10 LS SEP. BILGE OIL TK LCL 1 1000 900 - " DX007S-1FT-3 " " nc 4P-14-005 L075 S44 added

DAEHWA ENGINEERING
C.G :15B(cable o.d:10.3)
C.G :20A(cable o.d:12.0)
C.G :20B(cable o.d:12.7)
Spec. Table for Level Switch 15

Ship No. : HN1911/12 MODEL : LS-TM-1FT-65A Top Mounting type


Length Cable Drawing Conn. Enclosure Contact Yard Position P & ID
No. Tag No. Tank Name Function Q'ty Remark
No. Flange ( IP ) Cable no. (Boss No.) Page no.
A B E Gland Comp.

1 LAH-081107 PORT BOW TH. RM BILGE HAT LEVEL LAH 1 250 - 180 20A DX007S-1FTS-9 5K65A 56 nc AAM-66-008 L077 S46

2 LAH-081109 STBD STBD TH. RM BILGE HAT LEVEL LAH 1 250 - 180 " DX007S-1FTS-9 " " nc AAM--66-017 L079 S46

3 LAH-081113 PORT PURI RM BILGE HAT 1 LEVEL LAH 1 250 - 180 " DX007S-1FTS-9 " " nc AAM-58-007 L080 S43

4 LAH-081114 PORT PURI RM BILGE HAT 2 LEVEL LAH 1 250 - 180 " DX007S-1FTS-9 " " nc AAM-58-008 L081 S43

5 LAH-081115 PORT STERN TH. BILGE HAT ( FWD ) LEVEL LAH 1 250 - 180 " DX007S-1FTS-9 " " nc AAM-64-002 L068 S43

6 LAH-081119 CENTER STERN TH. BILGE HAT ( FWD ) LEVEL LAH 1 250 - 180 " DX007S-1FTS-9 " " nc AAM-64-010 L070 S44

7 LAH-081123 STBD PURI RM BILGE HAT 1 LEVEL LAH 1 250 - 180 " DX007S-1FTS-9 " " nc AAM-62-005 L083 S45

8 LAH-081124 STBD PURI RM BILGE HAT 2 LEVEL LAH 1 250 - 180 " DX007S-1FTS-9 " " nc AAM-62-006 L084 S45

9 LAH-081125 STBD STERN TH. BILGE HAT ( FWD ) LEVEL LAH 1 250 - 180 " DX007S-1FTS-9 " " nc AAM-64-006 L072 S45

10 LAH-081143 CO2 ROMM BILGE LEVEL LAH 1 250 - 180 " DX007S-1FTS-9 " " nc AAM-57-007 S43

11 LAH-081104 CENTER BOW TH. RM BILGE WELL LEVEL LAH 1 250 - 180 " DX007S-1FTS-9 " " nc AAM-66-001 L074 S46

12 LAH-081106 PORT BOW TH RM BILGE WELL LEVEL LAH 1 250 - 180 " DX007S-1FTS-9 " " nc AAM-66-007 L076 S46

DAEHWA ENGINEERING
C.G :15B(cable o.d:10.3)
C.G :20A(cable o.d:12.0)
C.G :20B(cable o.d:12.7)
Spec. Table for Level Switch 16

Ship No. : HN1911/12 MODEL : LS-TM-1FT-65A Top Mounting type


Length Cable Drawing Conn. Enclosure Contact Yard Position P & ID
No. Tag No. Tank Name Function Q'ty Remark
No. Flange ( IP ) Cable no. (Boss No.) Page no.
A B E Gland Comp.

13 LAH-081108 STBD BOW TH RM BILGE WELL LEVEL LAH 1 250 - 180 20A DX007S-1FTS-9 5K65A 56 nc AAM-66-016 L078 S46

14 LAH-081116 PORT STERN TH. RM SUNKEN BILGE LEVEL LAH 1 250 - 180 " DX007S-1FTS-9 " " nc AAM-64-003 L068 S43

15 LAH-081120 CENTER STERN TH. RM SUNKEN BILGE LEVEL LAH 1 250 - 180 " DX007S-1FTS-9 " " nc AAM-64-011 L071 S44

16 LAH-081126 STBD STERN TH. RM SUNKEN BILGE LEVEL LAH 1 250 - 180 " DX007S-1FTS-9 " " nc AAM-64-007 L073 S45

17 LAH-081134 COFFERDAM ( AFT ) BILGE LEVEL LAH 1 250 - 180 " DX007S-1FTS-9 " " nc AAM-57-007 32 (2/3)

18 LAH-081135 COFFERDAM ( FWD ) BILGE LEVEL LAH 1 250 - 180 " DX007S-1FTS-9 " " nc AAM-67-003 32 (2/3)

19 LAH-081136 HPR COMPART ( P ) BILGE WELL LEVEL LAH 1 250 - 180 " DX007S-1FTS-9 " " nc AAM-56-009 32 (2/3)

21 LAH-081137 HPR COMPART ( S ) BILGE WELL LEVEL LAH 1 250 - 180 " DX007S-1FTS-9 " " nc AAM-56-010 32 (2/3)

21 LAH-081130 CENTER STERN TH. BILGE LEVEL LAH 1 250 - 180 " DX007S-1FTS-9 " " nc AAM-64-012 S44

DAEHWA ENGINEERING
C.G :15B(cable o.d:10.3)
C.G :20A(cable o.d:12.0)
C.G :20B(cable o.d:12.7)
Spec. Table for Level Switch 18

Ship No. : HN1911/12 MODEL : LS-TM-2FT-100A Top Mounting type


Length Cable Drawing Conn. Enclosure Contact Yard Position P & ID
No. Tag No. Tank Name Function Q'ty Remark
No. Flange ( IP ) Cable no. (Boss No.) Page no.
A B E Gland Comp.

1 LAHL-081101 FWD A/M RM BILGE WELL ( P ) LEVEL LAHL 1 765 665 150 20C DX007S-2FTn 5K100A 56 nc/nc AAM-65-006 L066 S46

2 LAHL-081102 FWD A/M RM BILGE WELL ( S ) LEVEL LAHL 1 765 665 150 " DX007S-2FTn " " nc/nc AAM-65-007 L067 S46

3 LAHL-081111 PORT E / R BILGE WELL ( P ) LEVEL LAHL 1 765 665 150 " DX007S-2FTn " " nc/nc AAM-59-002 L060 S43

4 LAHL-081112 PORT E / R BILGE WELL ( S ) LEVEL LAHL 1 765 665 150 " DX007S-2FTn " " nc/nc AAM-59-003 L061 S43

5 LAHL-081117 CENT E / R BILGE WELL ( P ) LEVEL LAHL 1 765 665 150 " DX007S-2FTn " " nc/nc AAM-60-012 L062 S44

6 LAHL-081118 CENT E / R BILGE WELL ( S ) LEVEL LAHL 1 765 665 150 " DX007S-2FTn " " nc/nc AAM-60-013 L063 S44

7 LAHL-081121 STBD E / R BILGE WELL ( P ) LEVEL LAHL 1 765 665 150 " DX007S-2FTn " " nc/nc AAM-63-002 L064 S45

8 LAHL-081122 STBD E / R BILGE WELL ( S ) LEVEL LAHL 1 765 665 150 " DX007S-2FTn " " nc/nc AAM-63-003 L065 S45

Type changed
9 LAHL-052107 L.O PURI SLUDGE TANK ( P ) LEVEL LAHL 1 600 500 310 " DX007S-2FTn " " nc AAM-59-023 L042 S13
from page 13
Type changed
10 LAHL-052114 L.O PURI SLUDGE TANK ( C ) LEVEL LAHL 1 600 500 310 " DX007S-2FTn " " nc AAM-61-004 L044 S14
from page 13
Type changed
11 LAHL-052121 L.O PURI SLUDGE TANK ( S ) LEVEL LAHL 1 600 500 310 " DX007S-2FTn " " nc AAM-63-009 L046 S15
from page 13

DAEHWA ENGINEERING
C.G :15B(cable o.d:10.3)
C.G :20A(cable o.d:12.0)
C.G :20B(cable o.d:12.7)
Spec. Table for Level Switch 20

Ship No. : HN1911 / 12 MODEL : LS-TM-1FE-65A(Exd type) Top Mounting type


Contac
Length Cable Drawing Conn. Enclosure Yard Position P & ID
No. Tag No. Tank Name Function Q'ty t Remark
No. Flange ( IP ) Cable no. (Boss No.) Page no.
A B E Gland Comp.

1 LAH-081138 DRY BULK TANK BILGE WELL ( P ) LEVEL LAH 1 320 - 250 20A DX007S-1FTEx-2 5K65A 56 nc AAM-67-001 32 ( 2 / 3 )

2 LAH-081139 DRY BULK TANK BILGE WELL ( S ) LEVEL LAH 1 320 - 250 " DX007S-1FTEx-2 " " nc AAM-67-002 32 ( 2 / 3 )

3 LAH-081140 BLST PUMP ROOM BILGE LEVEL ( P ) LAH 1 300 - 230 " DX007S-1FTEx-2 " " nc AAM-57-002 32 ( 1 / 3 )

4 LAH-081141 BLST PUMP ROOM BILGE LEVEL ( C ) LAH 1 300 - 230 " DX007S-1FTEx-2 " " nc AAM-57-003 32 ( 1 / 3 )

5 LAH-081142 BLST PUMP ROOM BILGE LEVEL ( S ) LAH 1 300 - 230 " DX007S-1FTEx-2 " " nc AAM-57-004 32 ( 1 / 3 )

Type changed to
6 LAH-081146 CENT VOID SPACE BILGE LEVEL LAH 1 320 - 250 " DX007S-1FTEx-2 " " nc AAM-56-007 32 ( 2 / 3 )
page 13

6 LAH-081148 AGITATOR ROOM BILGE LEVEL ( P ) LAH 1 320 - 250 " DX007S-1FTEx-2 " " nc ADC-01-004 32 ( 2 / 3 )

7 LAH-081149 AGITATOR ROOM BILGE LEVEL ( S ) LAH 1 320 - 250 " DX007S-1FTEx-2 " " nc ADC-01-005 32 ( 2 / 3 )

DAEHWA ENGINEERING
C.G :15B(cable o.d:10.3)
C.G :20A(cable o.d:12.0)
C.G :20B(cable o.d:12.7)
22
Spare Parts List

Ship No. : HN1911/12


Quantity
Item Part Name Outline Working Spare Remarks
No. per Set per Vssl per Vssl

49.3 17.5 TCZ-L11

1 MICRO SWITCH 1 13 1 Z4G1L01B 675008

29.4
15A 125, 250 or 480VAC

NEC RD24E
88
2 SENSOR φ12 1 49 5 40-50AT

( Reed Switch
Molded In )

POLYCARBONATE &
90

3 SPARE BOX 1 ABS-V-O

150
150

DAEHWA ENGINEERING
DAEHWA ENGINEERING
Makes Sensors with Sense

Factory & Office


1-771 Gomo-ri, Jinre-myeon, Gimhae-si, Kyungnum, Korea
Tel : (055)342-9115/6, Fax : (055)342-9117
E-mail : [email protected]

Products
Level Switch
Flow Switch
Non-Flow Alarm Switch
Bilge High Level Alarm System
High & High-High Level Alarm System
Level Control & Indicating System
I.S. Barrier
Level Gauge

You might also like