0% found this document useful (0 votes)
596 views1 page

V2Grid Australia

The Numbat-7 is a bidirectional 7kW DC wall box charger designed for V2G/V2H and B2G/B2H applications, allowing electric vehicle batteries and residential energy storage to connect to the AC grid for charging and backup power. It features high efficiency, a wide DC voltage range, and various safety and operational standards. The device supports multiple charging protocols and includes optional components for enhanced functionality and monitoring.

Uploaded by

rimshaanis861
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
596 views1 page

V2Grid Australia

The Numbat-7 is a bidirectional 7kW DC wall box charger designed for V2G/V2H and B2G/B2H applications, allowing electric vehicle batteries and residential energy storage to connect to the AC grid for charging and backup power. It features high efficiency, a wide DC voltage range, and various safety and operational standards. The device supports multiple charging protocols and includes optional components for enhanced functionality and monitoring.

Uploaded by

rimshaanis861
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

AUSTRALIA SPEC SHEET AUSTRALIA

NUMBAT-7
V2G Mode EV Battery Voltage vs. AC Output Power V2G Mode AC Output Voltage vs. AC Output Power
10 10

AC Output Power (KW)


AC Output Power (KW)
9 9

7kW 750V SINGLE PHASE V2G/V2H DC WALLBOX CHARGER 8


7
6
8
7
6
5 5
4 4

Numbat-7 is the bidirectional 7kW DC wall box for V2G/V2H and B2G/B2H applications, to connect the EV battery or the 3
2
3
2
Residential energy storage battery to the single phase AC grid to realize the EV dis/charging V2G function and Home power 1 1
0 0
backup V2H function. This V2G/V2H and B2G/B2H functions enable EV battery and residential battery to be used for grid 0 100 200 300 400 500 600 700 800 50 100 150 200 250 300
DC Input Voltage, VDC AC Output Voltage, VDC
energy storage, backup power supply, and smart grid node.

Charging Mode AC Input Voltage vs. DC Output Power Charging Mode DC Output Voltage vs. DC Output Current
10 800

DC Output Voltage (V)


DC Output Power (KW)
9 700
8
600
7
Solar Panel Priority Load General Load
6 500
Group
5 400
4 300
3
200
AC BOX 2
AC 220V AC 220V
1 100
AC 220V 0 0
V2H BOX
Solar 50 100 150 200 250 300 0 0 0 0 0
Inverter AC Input Voltage, VAC DC Output Current, A
General Load
Backup Load
Transformer Home AC BOX
B2G V2G MPPT
AC Grid AC Grid

TECHNICAL SPECIFICATIONS
V2G Electric B2G V2G
Vehicle
V2H BOX

Ambient Temperature - 40°c - + 75°c, derating from 45°C


V2G DC Charger Environmental
Cooling Fan cooling
Altitude 2000m
Input voltage & current 230Vac, L +N+PE; 20A
Input voltage/frequency range 100 Vac -264 Vac, 45 Hz -65 Hz
AC Input
Power factor ≥ 0.98 Full-load output power of @50%~100%
THD ≤ 5% Full-load output power of @50%~100%
Charging Mode
Rated power 7kW
DC Output Voltage and current range 200Vdc -750Vdc, 0 -23A
Efficiency (max) ≥ 95.0%
V2G AC Box if no V2H box, need to select this Box AC energy meter, SPD, AC distribution
Charging and V2G Mode convert time (Battery test) 10mS
UNIQUE FUNCTION MAIN FEATURES APPLICATION DC input voltage and Output power See Table
• 7kW DC charger with AC single phase • Inside high-frequency transformer • V2G EV charger DC Input
Max Input current 23A
for CCS, CHAdeMO, or GBT standard isolation to enhance safety • B2G Energy storage battery inverter Output AC Voltage and Output power See Table
• V2G, V2H, B2G, B2H configuration • Max efficiency is higher than 95.0% • V2H/B2H application with optional off- Rated power and current 7kW / 38A
• Optional V2H Box to realize the off-grid • Low standby power consumption, less grid V2H box AC Output Output AC Frequency 50Hz/60Hz
power backup than 7W • Residential off-grid backup power THDi / Output Power Factor < 5% / User Setting, 0.8 Leading-0.8 Lagging
• Wide DC voltage range from 200V to • Residential use with low noise, <60dB, supply V2G Mode Efficiency (max) ≥ 950%
Voltage accuracy and distortion 1 % and <3% // Off Grid only support 230Vac
750V EMC class B
Off Grid Power factor > 0.7
• One key to realize the manual charging • IP65
Dynamic volt stability & recovery time 5% and 20mS
and discharging Bidirectional Mid AC energy meter, SPD, AC distribution
V2H V2H Box
PV inverter connection, Grid switch connector, backup 12V/10Ah battery
(optional)
Grid Connection Power switch in the main grid, backup grid and V2G charger by AC contactor
V2H SOLUTION Protocol Standard OCPP 1.6J/OCPP 2.0, ISO15118/ISO15118-20, CHAdeMO Vl.2, EVPOSSA
B2G WallBox Battery side: Charge/Discharge Voltage 200-750V, max power 7kW, max current 23A
converter AC side: 100 Vac -264 Vac, 45 Hz -65 Hz, max current 32A, Grid connection standard: same to V2G
Monitor interface LAN lOM/lO0M and LTE wireless modem support
Charging Indication RGB Light bar Green-normal, Yellow-charging, Blue-discharging, Red-failure
Control HMI Tempered glass protective 5” TFT Touch Screen LCD, RFID support
Metering Bidirectional Mid AC energy meter in optional V2H box
Hot key one EPO key, one V2G action key
Reliability and Protection IP65, IKl0 for cabinet and IK08 for LCD
safety EMC/Safety UL2202, CE, EN61000-6-3/EN61000-6-1 Class B; EN 61851-1/EN 61851-23/EN 61851-24
V2G SOLUTION Grid connection Certification VDE-AR-N 4105, DIN V VDE V 0126-1-1, UL9741, UL1741, UL1741SA/SB, IEEE1547:2018, IEEE1547.1:2020
Mechanical Dimension / Weight 612mm(H)x340mm(W)x187mm(D) I ≤40 kg (include the charging gun)
Charging cable configuration 32A/750V for CCS, 32A/500V for CHAdeMO, 32A/750V for GBT
Optional Pedestal Pedestal with cable retractors