Daikin Aircond Outdoor Unit Specs
Daikin Aircond Outdoor Unit Specs
ENGINEERING DATA
Inverter Split Unit Air Conditioner
Ceiling Concealed
Cooling Only [50Hz]
FDMFC-A Series
Table of Contents
Table of Contents
Introduction..........................................................................................................................1
Model Name and Power Supply.....................................................................................1
Nomenclature.................................................................................................................2
Functions.............................................................................................................................3
Specifications......................................................................................................................4
Dimensions..........................................................................................................................6
Wiring Diagrams..................................................................................................................9
Piping Diagrams................................................................................................................12
Capacity Tables.................................................................................................................15
Capacity Tables............................................................................................................15
Capacity Correction Factor ..........................................................................................19
Operation Limit..................................................................................................................20
Fan Performance...............................................................................................................21
Sound Level.......................................................................................................................25
Measuring Location......................................................................................................25
Sound Pressure Level & NC Curve..............................................................................26
Electric Characteristic......................................................................................................32
Accessories List................................................................................................................33
i
Introduction
Introduction
Model Name and Power Supply
FDMFC50AV1M RZFC50BGVMM
FDMFC60AV1M RZFC60BGVMM
FDMFC85AV1M RZFC85BVMM
FDMFC100AV1M RZFC100BVMM
FDMFC125AV1M RZFC125BY1M
3Phase, 380-415V, 50Hz
FDMFC140AV1M RZFC140BY1M
1
Introduction
Nomenclature
Indoor Unit
Definition Description
Major Design
A : A Series
Category
Country M : Malaysia
Outdoor Unit
Definition Description
Country M : Malaysia
Remark:
*Capacity value under Nomenclature is an indication.
Please refer to Specifications for exact capacity value.
2
Functions
Functions
FDMFC85/100/125/14A
RZFC85/100/125/140
FDMFC50/60/71A
RZFC50/60/71
Category Functions
Inverter ● ●
Operation Limit for Cooling (°CDB)(O/D) 21~46 21~46
Basic Function Operation Limit for Cooling (°FDB)(O/D) 69.8~114.8 69.8~114.8
Operation Limit for Heating (°CWB)(O/D) - -
Operation Limit for Heating (°FWB)(O/D) - -
Scroll Compressor - -
Compressor Rotary Compressor - -
Swing Compressor ● ●
4-Way Airflow Operation - -
Comfortable
8-Way Airflow Operation - -
Airflow
Surround Airflow Operation - -
Auto Fan Speed ● ●
Switchable Fan Speed ● ●
Comfort Control
Auto Swing - -
Indoor Unit Quiet Operation - -
Programme Dry Function ● ●
ECO + - -
Operation Powerful/Turbo Mode - -
Sleep ● ●
Fan Only ● ●
Indoor Unit ON/OFF Button - -
Signal Receiving Sign *1 - -
Lifestyle R/C with Backlight *2 ●* ●*
Convenience LED Display ON/OFF Button - -
Room Temperature Display *2 ●* ●*
Streamer ON/OFF Button *1 - -
Saranet Filter ●* ●*
GIN-ION Blue Filter - -
PM 2.5 - -
Titanium Apatite - -
Health & Clean
Streamer - -
Ionizer - -
Fresh Air Intake Kit - -
Washable Grille - -
Weekly Timer Operation *3 ●* ●*
Timer 24-hour ON/OFF Timer (R/C) *1 ● ●
24-hour RTC ●* ●*
Auto Restart (After Power Failure) ● ●
Worry Free Self-diagnosis ● ●
Wiring Error Check Function ● ●
(Reliability &
Anti-corrosion Treatment of Outdoor Heat Exchanger Gold Fin MCHE
Durability) Low/High Voltage Shield - -
R32 Refrigerant Gas Sensor - -
ESP Selection ● ●
Water Pump (Water Drainage Pipe Flexibilty) ●* ●*
Flexibility °F/°C Changeover R/C Temperature Display
● ●
(Factory setting: °C)
Pre-charged Piping Length 10m 15m
Wireless LAN Connectivity ●* ●*
Remote Control BAG Connectivity - -
iTM Connectivity - -
Wireless (Optional) DGS01 DGS01
Remote Controller Wired DSLM8 DSLM8
Wired (Optional) BRC51D62 BRC51D62
Note: ● : Available
- : Not Available
●* : Optional (Refer to DAMA Spare Part team for more details on optional items.)
*1: Applicable when wireless (DGS01) remote controller is used for selected models.
*2: Applicable when wired (BRC51D62) (SHIRO) is used.
*3: Applicable when wired (DSLM8 / BRC51D62) remote controller is used.
3
Specifications
Specifications
INDOOR UNIT FDMFC50A FDMFC60A FDMFC71A FDMFC85A
MODEL
OUTDOOR UNIT RZFC50B RZFC60B RZFC71B RZFC85B
kW 5.42 (2.30-5.60) 6.00 (2.60-6.30) 7.10 (3.20-8.00) 8.79 (4.20-10.00)
Rated Capacity (Min - Max) 18500 20500 24200 30000
Btu/h
(7800-19100) (8900-21500) (10900-27300) (14300-34100)
Rated Running Current A 8.51 10.10 9.20 12.40
Rated Power Consumption W 1940 2300 2105 2770
EER W/W 2.79 2.61 3.37 3.17
CSPF Wh/Wh 4.16 4.13 4.36 4.76
Power Factor (Rated) 0.99 0.99 0.99 0.97
Piping Liquid mm 6.4 9.5
Connections Gas mm 12.7 15.9
Type R32
Refrigerant
Charge kg 0.95 0.95 1.15 0.95
Max. Interunit Piping Length m 30 30 30 50
Max. Interunit Height Difference m 15 15 15 30
Drawing No. 3D138361A
INDOOR UNIT FDMFC50A FDMFC60A FDMFC71A FDMFC85A
Super High CFM 590 950
High CFM 590 950
Airflow Rate
Medium CFM 525 810
Low CFM 430 700
Sound Pressure Level (SH/H/M/L) dBA 40/40/38/34 41/41/38/35
External Static Standard (H/M/L) Pa 30/22/17
Pressure High (SH/M/L) Pa 50/22/17
Type SIROCCO
Fan
Drive DIRECT
Type AC
Motor Output W 97 150
Fan Motor
Running Current (Rated) A 0.64 0.91
Power Consumption (Rated) W 149 208
Air Direction Control DUCTED
Air Filter N/A
Dimensions (H x W x D) mm 250 x 700 x 700 250 x 1000 x 700
Packaged Dimensions (H x W x D) mm 337 x 916 x 924 337 x 1216 x 924
Weight kg 24 31
Condensate Drain Size mm 32
Drawing No. 3D138360-1 3D138360-2 3D138360-3 3D138360-4
OUTDOOR UNIT RZFC50B RZFC60B RZFC71B RZFC85B
Casing Colour IVORY WHITE
Airflow Rate High CFM 1464 1464 1464 2186
Sound Pressure Level dBA 52 52 52 53
Type PROPELLER
Fan
Drive DIRECT
Type DC
Index of protection (IP) 23
Insulation Grade E
Fan Motor Running Current (Rated) A 0.92 0.92 0.92 1.26
Power Consumption (Rated) W 71 71 71 131
Motor Output W 68 68 68 55
Poles 8
Type HERMETIC SWING
Compressor Oil type DAPHNE FW68DA
Oil amount cm3 350 350 650 425
Heat Exchanger Type FIN TUBE FIN TUBE FIN TUBE MICROCHANNEL
Dimensions (H x W x D) mm 615 x 845 x 300 615 x 845 x 300 615 x 845 x 300 695 x 930 x 350
Packaged Dimensions (H x W x D) mm 679 x 992 x 414 679 x 992 x 414 679 x 992 x 414 760 x 1084 x 473
Weight kg 37 37 37 40
Document No. 2D138363E
1) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT).
2) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
COOLING
INDOOR: 27°CDB / 19°CWB
OUTDOOR: 35°CDB
4
Specifications
5
Dimensions
Dimensions
Indoor Unit
Model : FDMFC50/60A
3D119966D
Note: Dimension in mm
Model : FDMFC71/85A
3D119967E
Note: Dimension in mm
6
Dimensions
Model : FDMF100/125/140A
3D119968E
Note: Dimension in mm
Outdoor Unit
Model : RZFC50/60/71
3D138338E
Note: Dimension in mm
7
Dimensions
Model : RZFC85/100
3D144971B
Note: Dimension in mm
Model : RZFC125/140
3D144973B
Note: Dimension in mm
8
Wiring Diagrams
Wiring Diagrams
Indoor Unit
Model : FDMFC50/60/71/125/140A
3P674541A
Model : FDMFC85/100A
3P678800
9
Wiring Diagrams
Outdoor Unit
Model : RZFC50/60/71
3P721453
Model : RZFC85/100
3P721483
10
Wiring Diagrams
Model : RZFC125/140
3D138310B
11
Piping Diagrams
Piping Diagrams
Indoor Unit
Model : FDMFC-A
3D137822B
Note: Dimension in mm
12
Piping Diagrams
Outdoor Unit
Model : RZFC50/60
3D137805C
Note: Dimension in mm
Model : RZFC71
3D137806D
Note: Dimension in mm
13
Piping Diagrams
Model : RZFC85/100
3D138314D
Note: Dimension in mm
Model : RZFC125/140
3D137784C
Note: Dimension in mm
14
Capacity Tables
Capacity Tables
Cooling Only
3D138028A
3D138029A
15
Capacity Tables
3D138030A
3D138277B
16
Capacity Tables
3D138278B
3D138050B
17
Capacity Tables
3D138048B
18
Capacity Tables
FDMFC-A - RZFC
100
95
90
Capacity Correc�on Ra�o
85
80
75
70
65
60
0 5 10 15 20 25 30 35 40 45 50 55
Connec�on Pipe Length (m)
Notes:
1.-------- represents the correction ratio for cooling capacity.
2.The correction ratio remains the same whether the outdoor unit is to be installed above or below
the indoor unit.
3.Calculation method for cooling capacity
Capacity = cooling capacity obtained from capacity table x capacity correction ratio.
4.The actual unit piping length shall not exceed the maximum piping length shown on the table above.
3D137578E
19
Operation Limit
Operation Limit
Model : RZFC
3D138311C
20
Fan Performance
Fan Performance
Model : FDMFC50/60A
3D121584F
21
Fan Performance
Model : FDMFC71/85A
3D121598E
22
Fan Performance
Model : FDMFC100/125A
3D121606E
23
Fan Performance
Model : FDMFC140A
3D121607E
24
Sound Level
Sound Level
Measuring Location
FDMFC50A
FDMFC60A
FDMFC71A
FDMFC85A
FDMFC100A
FDMFC125A
FDMFC140A
Notes:
1. Operation sound is measured in an anechoic chamber.
25
Sound Level
Low 41 35 29 30 24 17 10 34 29
NC Curve
3D138903A
26
Sound Level
Low 41 37 32 30 25 16 9 35 29
NC Curve
3D138908A
27
Sound Level
Low 42 36 32 30 25 17 9 35 29
NC Curve
3D138909A
28
Sound Level
Low 44 37 32 31 27 18 11 36 30
NC Curve
3D138910A
29
Sound Level
Low 45 38 32 30 25 16 11 36 29
NC Curve
3D138913A
30
Sound Level
Low 43 37 32 31 27 16 10 36 30
NC Curve
3D138915A
31
Electric Characteristic
Electric Characteristic
Unit Combination Power Supply COMP OFM IFM
Indoor Unit Outdoor Unit Hz Voltage Voltage Range MCA MFA RHz RLA kW FLA kW FLA
Symbols: Notes:
MCA : Min. circuit amps (A) 1. RLA is based on the following conditions.
MFA : Max. fuse amps (A) Indoor temp. 27°CDB / 19°CWB
COMP : Compressor Outdoor temp. 35°CDB
RHz : Rated Operating Frequency (Hz) 2. Select the wire size according to the MCA.
RLA : Rated loads amps (A) 3. Maximum allowable voltage that is unbalance between phases is 2%.
OFM : Outdoor fan motor 4. Use circuit breaker instead of fuse
IFM : Indoor fan motor
kW : Fan motor rated output (kW)
FLA : Full load amps (A)
3D138365A
32
Accessories List
Accessories List
Model Number
FDMFC50/60A FDMFC71/85A FDMFC100/125/140A
Optional Accessories
NS Splitter R50044157819
33
ED3CC6-DM23V1