16. LEM current sensor HTFS

The Current Transducer HTFS 200..800-P/SP2 measures DC, AC, pulsed, and mixed currents with galvanic isolation between the primary and secondary circuits. It features a Hall effect measuring principle, low power consumption, and operates within a temperature range of -40 to +105 °C. The device is suitable for various applications, including industrial equipment and power supplies, and complies with safety standards to prevent electrical shock risks.

Uploaded by

tamin saat jonub
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views

16. LEM current sensor HTFS

The Current Transducer HTFS 200..800-P/SP2 measures DC, AC, pulsed, and mixed currents with galvanic isolation between the primary and secondary circuits. It features a Hall effect measuring principle, low power consumption, and operates within a temperature range of -40 to +105 °C. The device is suitable for various applications, including industrial equipment and power supplies, and complies with safety standards to prevent electrical shock risks.

Uploaded by

tamin saat jonub
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Current Transducer HTFS 200..

800-P/SP2 IPN = 200-400-800 A


For the electronic measurement of currents : DC, AC, pulsed, mixed,
with galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).

All Data are given with a RL = 10 kΩ


Electrical data
Primary nominal Primary current Type RoHS since
current rms measuring range datecode
IPN (A) IPM (A) Features
200 ± 300 HTFS 200-P/SP2 45326 • Hall effect measuring principle
400 ± 600 HTFS 400-P/SP2 45060 • Galvanic isolation between primary
800 ± 1200 HTFS 800-P/SP2 45060 and secondary circuit
VOUT Output voltage (Analog) @ IP VREF ± (1.25I P/ IPN) V • Low power consumption
IP = 0 VREF ± 0.025 V • Single power supply +5V
VREF Reference voltage1) - Output voltage 1/2VC ± 0.025 V • Ratiometric offset
VREF Output impedance typ. 200 Ω • TA = -40..+105 °C
VREF Load impedance ≥ 200 kW • Isolated plastic case recognized
RL Load resistance ≥2 kΩ according to UL 94-V0.
ROUT Output internal resistance < 10 Ω
CL Capacitive loading <1 µF Special Features
VC Supply voltage (± 5 %) 5 V
IC Current consumption @ VC = 5 V 22 mA • PCB fixation by 4pins x Ø 1.0

Accuracy - Dynamic performance data Advantages

X Accuracy 2) @ IPN, TA = 25 C ≤±1 % of IPN • Small size and space saving


εL Linearity error (0 .. 1.5 x IPN) ≤ ± 0.5 % of IPN • Only one design for wide current
ratings range
TCVOE Temperature coefficient of VOE @ IP = 0 ≤ ± 0.3 mV/K
• High immunity to external
TCVREF Temperature coefficient of VREF ≤ ± 0.01 %/K
interference.
TCV / V Temperature coefficient of VOUT / VREF @ IP = 0 ≤ ± 0.2 mV/K
OUT REF
• VREF. IN/OUT.
TCVOUT Temperature coefficient of VOUT ≤ ± 0.05 % of reading/K
VOM Magnetic offset voltage @ IP = 0,
after an overload of 3 x IPN DC < ± 0.5 % of IPN Applications
tra Reaction time @ 10 % of IPN <3 µs
tr Response time to 90 % of IPN step < 7 µs • Forklift drives
di/dt di/dt accurately followed > 100 A/µs • AC variable speed drives
Vno Output voltage noise (DC ..10 kHz) < 15 mVpp • Static converters for DC motor
(DC .. 1 MHz) < 40 mVpp drives
BW Frequency bandwidth (- 3 dB) 3) DC .. 50 kHz • Battery supplied applications
General data • Uninterruptible Power Supplies
(UPS)
TA Ambient operating temperature - 40 .. + 105 °C • Switched Mode Power Supplies
TS Ambient storage temperature - 40 .. + 105 °C (SMPS)
m Mass 60 g • Power supplies for welding
applications.
Standard EN 50178: 1997
1)
Notes : It is possible to overdrive VREF with an external reference voltage
between 2 - 2.8 V providing its ability to sink or source approx. 2.5 mA. Application domain
2)
Excluding offset and Magnetic offset voltage.
• Industrial.
3)
Small signal only to avoid excessive heatings of the magnetic core.
Page 1/3

120202/6 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com
Current Transducer HTFS 200..800-P/SP2

Isolation characteristics

Vb Rated isolation voltage rms with following conditions


- Over voltage category III
- Pollution degree 2
- Non-uniform field

Vd Rms voltage for AC isolation test, 50 Hz, 1 min 2.5 kV


Ve Partial discharge extinction voltage rms @ 10pC >1 kV
Vw Impulse withstand voltage 1.2/50 µs 4 kV
dCp Creepage distance >4 mm
dCl Clearance distance >4 mm
CTI Comparative tracking index (Group IIIa) > 220

If insulated cable is used for the primary circuit, the


voltage category could be improved with the following table :
Cable insulation (primary) Category
HAR 03 300V CAT III
HAR 05 400V CAT III
HAR 07 500V CAT III

Safety

This transducer must be used in electric/electronic equipment with respect to


applicable standards and safety requirements in accordance with the manufacturer’s
operating instructions.

Caution! Risk of electrical shock

When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a built-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3

120202/6 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com
Dimensions HTFS 200..800-P/SP2 (in mm. 1 mm = 0.0394 inch)

Ip
40
0.5
16.5
33 R3 3

20.3
d22
33

16 5

26
4
3-P=2.54

4-d=1.0 1

3.5+/-1 4.5
4-0.25x0.5
7

Required Connection Circuit


Terminal Pin
HTFS 1...+5V
2...0V
4 Vref(IN/OUT) Vref(IN/OUT) 3...Output
4...Vref(IN/OUT)
3 Output Output
47nF 4.7nF
2 0V 0V
1 +5V 47nF +5V

Operation Principle

+Vc

Vout

Vref.(IN/OUT)

Ip 0V

Mechanical characteristics Remarks


• General tolerance ± 0.2 mm • VOUT is positive when IP flows in the direction of the arrow.
• Fixation 4 pins x Ø 1.0 • Temperature of the primary conductor should not exceed
• Recommended PCB hole Ø 1.2 mm 120°C.
• Fastening & connection of secondary 4 pins 0.5 x 0.25
• Recommended PCB hole Ø 0.7 mm

Page 3/3

120202/6 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com