D5A-T RC 1500: General
D5A-T RC 1500: General
D5A-T RC 1500
21376860 01
General
Number of cylinders 4
Displacement, total 4,76 liters [290,7 cu. in]
Firing order 1-3-4-2
Bore 108 mm [4,25 in]
Stroke mm 130 mm [5,12 in]
Compression ratio 17,6:1
Overload
Performance 25% load 50% load 75% load 100% load 110% load
ISO Standard Power 77 kW [105 hp] 19,3 38,5 57,8 77 84,7
Torque 490 Nm [362 lbf ft] 118 239 363 490 542
Mean piston speed 6,5 m/s [21,3 ft/sec]
Effective mean pressure 1,29 Mpa [187 psi] 0,3 0,6 1,0 1,3 1,4
Max combustion pressure Mpa [psi] 7,1 8,1 9,4 10,7 11,2
Lubrication system
Lubricating oil consumption at ISO Standard Power liter/h [US Gal/h] 0,05
Lubricating oil system capacity including std. filters liters [US Gal] 13
Lubricating oil system capacity including classified (twin) filters liters [US Gal] 16
Fuel system
Specific fuel consumption g/kWh [lb/hph] 255 219 217 222 225
Total fuel flow liter/h [US Gal/h] 375
Maximum return flow liter/h [US Gal/h]
Feed pump pressure kPa [in H2 O] 500
Feed pump max suction head m 1
Max allowable back pressure in fuel return line kPa [H2 O] 50
2
Document No Issue Index
D5A-T RC 1500
21376860 01
Intake system
Air consumption, (at 27oC) m3/min [cu.ft/min] 3,7 4,02 4,5 5,1 5,4
Max permissible air intake restriction kPa [in H2 O] 2,5
Exhaust system
Heat rejection to exhaust kW [BTU/min] 13,9 22,7 35 49 54,5
Exhaust gas temperature after turbine oC [oF] 210 300 385 455 480
Max allowable back pressure in exhaust line kPa [H2 O] 3
Exhaust gas flow at Exhaust gas temperature after turbine m3/min [cu.ft/min] 6,6 8,6 11,2 14,1 15,2
Power Standards
The engine performance corresponds to ISO 3046, BS 5514, DIN 6271 and in general SAE J 1349. The technical data applies to an engine operation on a fuel with
calorific value of 42,7 MJ/ kg (18360 BTU/ lb) and a density of 0,84 kg/ liters (7,01 lb/ US gal, 8,42 lb/Imp gal), also where this involves a deviation from the standards.
Engine speed governor in accordance with ISO 3046/IV, class A1 and ISO 8528-5 G2 (G3 with electronic speed governor).
Rating Guidlines
ISO Standard Power for continuous operation with 10% overload capability for 1 hour of 12.