0% found this document useful (0 votes)
17 views

TC1-D9511

The document provides technical data for TC1 contactors, detailing specifications such as maximum rated operational voltage, current ratings, power ratings, and mechanical life. It emphasizes the importance of adhering to safety regulations and proper installation practices. Additionally, it lists various models and their corresponding electrical characteristics, including coil consumption and dimensions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views

TC1-D9511

The document provides technical data for TC1 contactors, detailing specifications such as maximum rated operational voltage, current ratings, power ratings, and mechanical life. It emphasizes the importance of adhering to safety regulations and proper installation practices. Additionally, it lists various models and their corresponding electrical characteristics, including coil consumption and dimensions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Technical Data: TC1 Contactors

! Important Safety Notice


It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET
wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and
Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment
being installed such as the Machinery Directive and current health and safety legislation must also be adhered to.
All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation.
All connections should be checked periodically to ensure correct tightness.

DO NOT USE POWER TOOLS ON THESE PRODUCTS

Code AC TC1-D09 TC1-D12 TC1-D18 TC1-D22 TC1-D25

DC TP1-D09 TP1-D12 TP1-D18 TP1-D22 TP1-D25

10 10 10 10 10
01 01 01 01 01
004 004 004 - 004
008 008 - - 008

Maximum Rated Operational Voltage 690V 690V 690V 690V 690V


Maximum rated current for motor control 9A 12A 18A 22A 25A
(3 phase 440V, 50-60Hz, for AC3 Duty)

Maximum standard power rating Kw / hp Kw / hp Kw / hp Kw / hp Kw / hp


for motor control as AC3 Duty 0≤55̊C, 415V
4 / 5.5 5.5 / 7.5 9 / 12.5 11 / 15 11 / 15
EN 60947-4-1
230V HP 2 3 5 - 7.5
3 phase AC3 460/480V HP 5 7.5 10 - 15
575/600V HP 7.5 10 15 - 20
Mounting position (w.r.t normal vertical mounting ± 30 ̊ ± 30 ̊ ± 30 ̊ ± 30 ̊ ± 30 ̊
plane)*

Maximum thermal current Ith (0 ≤ 40̊C) 25A 25A 32A 32A 40A
Maximum Operating Rate AC 3600 3600 3600 3600 3600
(operations / hr) DC 3600 3600 3600 3600 3600
50 Hz 60 / 7 VA 60 / 7 VA 60 / 7 VA 90 / 7.5 VA 90 / 7.5 VA

Average Coil Consumption


60 Hz 60 / 7.5 VA 60 / 7.5 VA 60 / 7.5 VA 60 / 7.5 VA 90 / 8.5 VA
(inrush / sealed) 50/60
70 / 8 VA 70 / 8 VA 70 / 8 VA 70 / 8 VA 100 / 8.5 VA
Hz

DC 9 / 9W 9 / 9W 9 / 9W 9 / 9W 11 / 11W
AC 2 to 3W 2 to 3W 2 to 3W 2 to 3W 2.5 to 3.5W
Heat dissipation at
DC 9W 9W 9W 9W 11W
50 or 60
TC1
Hz 20 20 20 20 16
Mechanical Life 50 / 60
(in millions of operations) Hz 15 15 15 15 12
TP1 30 30 30 30 25
Power contact terminal capacity mm² 4 4 6 6 10

Recommended Tightening Torque 1.2Nm 1.2Nm 1.2Nm 1.2Nm 1.2Nm

Over-all dimensions in mm AC

Projection
Page 1 (TCA2-D/TC1-D)
of 1 80mm 80mm 85mm 85mm 93mm

Over-all dimensions in mm DC

Projection (TCA3-D/TP1-D) 115mm 115mm 120mm 120mm 130mm

Weight (TC1-D/TP1-D) kg 0.32 / 0.58 0.32 / 0.60 0.35 / 0.85 0.35 / 0.85 0.505 / 0.88

Page 1 of 2 EDS1287-001
Technical Data: TC1 Contactors

Code AC TC1-D32 TC1-D40 TC1-D50 TC1-D65 TC1-D80


TC1-D95
DC TP1-D32 TP1-D40 TP1-D50 TP1-D65 TP1-D80

10 - - - - -
01 11 11 11 11 11
- 004 - 004 004 -
- 008 - 008 008 -

Maximum Rated Operational Voltage 690V 690V 690V 690V 690V 690V
Maximum rated current for motor control 32A 40A 50A 65A 80A 95A
(3 phase 440V, 50-60Hz, for AC3 Duty)

Kw / hp Kw / hp Kw / hp Kw / hp Kw / hp Kw / hp
Maximum standard power rating
for motor control as AC3 Duty 0≤55̊C, 415V
15 / 20 22 / 30 25 / 35 37 / 50 45 / 60 45 / 60
EN 60947-4-1
230V HP 10 10 15 20 25 25
3 phase AC3 460/480V HP 20 30 40 50 60 60
575/600V HP 25 30 40 50 60 60
Mounting position (w.r.t normal vertical mounting ± 30 ̊ ± 30 ̊ ± 30 ̊ ± 30 ̊ ± 30 ̊ ± 30 ̊
plane)*

Maximum thermal current Ith (0 ≤ 40̊C) 50A 60A 80A 80A 125A 125A
Maximum Operating Rate AC 3600 3600 3600 3600 3600
(operations / hr) DC 3600 3600 3600 3600 -
50 Hz 90 / 7.5 VA 200 / 20 VA 200 / 20 VA 200 / 20 VA 200 / 20 VA 200 / 20 VA

Average Coil Consumption


60 Hz 90 / 8.5 VA 200 / 22 200 / 22 200 / 22 200 / 22 200 / 22
(inrush / sealed) 50/60
100 / 8.5 VA 245 / 26 VA 245 / 26 VA 245 / 26 VA 245 / 26 VA 245 / 26 VA
Hz

DC 11 / 11W 22 / 22W 22 / 22W 22 / 22W - -


AC 2.5 to 3.5W 6 to 10W 6 to 10W 6 to 10W 6 to 10W 6 to 10W
Heat dissipation at
DC 11W 22W 22W 22W 22W -
50 or 60
TC1
Hz 16 16 16 16 10 10
Mechanical Life 50 / 60
(in millions of operations) Hz 12 6 6 6 4 4
TP1 25 20 20 20 20 -
Power contact terminal capacity mm² 10 25 25 25 50 50

Recommended Tightening Torque 1.2Nm 1.2Nm 1.2Nm 1.2Nm 1.2Nm 1.2Nm

Over-all dimensions in mm AC

Page
Projection 1 (TCA2-D/TC1-D)
of 1 98mm 114mm 114mm 114mm 125mm 125mm

Over-all dimensions in mm DC

Projection (TCA3-D/TP1-D) 135mm 171mm 171mm 171mm 181mm

Weight (TC1-D/TP1-D) kg 0.525 / 0.88 1.15/2.1 1.15/2.12 1.15/2.16 1.15/2.22 1.5 (TC1-D)

AC Coils DC Coils
Contactor Part Number Contactor Amperage Voltage
Part Number Voltage
Amperage
TX4D2*D TP1 9-18A
TX1D2*7 9 - 18A
24, 110, 230, 415 TX4D4*D TP1 25-32A 12V, 24V
TX1D4*7 25 - 32A VDC **
VAC * LX4D40*D TP1 40-65A
TX1D6*7 40 - 95A
LX4D80*D TP1 80A
* B7 = 24VAC, F7 = 110VAC, P7 = 230VAC, N7 = 415VAC
** JD = 12VDC, BD = 24VDC
Other voltages available on request
Other voltages available on request