Supplied parts
Specifications
INPUT VOLTAGE (VDC) 12 VDC
CURRENT
STANDBY AVG1 46 mA
MAX AVG2 60 mA
PEAK3 250 mA
Optional Features
Optical Tamper enabled by default – Once activated, when the mounting plate is removed, the optical tamper
will
open the circuit between Tamper#1 and Tamper#2 reader control lines. Tamper#1 and Tamper#2 control lines are
interchangeable. Either of these lines can be connected with the reader ground line to reduce the number of cable
cores required in the reader cable. Tamper#1 and Tamper#2 are rated 0-12VDC at 100mA.
Configuration Cards – The reader can be modified to meet the specific requirements of an installation.
Configuration options include; audio visual, and CSN outputs. See the HID Reader Manager™ solution on
www.hidglobal.com for further details.
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this
summary. Company, product names and data used in sample output are fictitious. Specifications are subject to
change without notice. © 2018 HID Global Corporation/ASSA ABLOY AB. All rights reserved. This document may
not be reproduced, disseminated or republished in any form without the prior written permission of HID Global
Corporation. HID GLOBAL, HID, the HID Brick logo, the Chain Design, HID Reader Manager, HID Mobile Access,
and iCLASS SE are trademarks or registered trademarks of HID Global, ASSA ABLOY AB, or its affiliate(s) in the
US and other countries and may not be used without permission. All other trademarks, service marks, and product
or service names are trademarks or registered trademarks of their respective owners.
Installation
ATTENTION
Observe precautions for handling ELECTROSTATIC SENSITIVE DEVICES
Mounting directly to the wall/mullion mount
PIGTAIL DESCRIPTION
Red +VDC
Drain Unused
Violet *Tamper #1
Violet/White *Tamper #2
Tamper Output. When activated or when the reader is unpowered, the circuit between Tamper#1 and Tamper#2
reader control lines will open.
Note: Wiring the reader incorrectly may permanently damage the reader.
Test the reader with a card. The buzzer should beep and the LED should flash.