84fdvsdfv54
84fdvsdfv54
About This The Ilumipod 48 IP Optic RGBW Quick Reference Guide (QRG) contains
Guide the product’s connection and mounting information, as well as the menu
options and DMX values.
Refer to this product’s User Manual for detailed information and
instructions. You can download the User Manual from the ILUMINARC®
website: www.iluminarc.com.
Disclaimer Read ALL the disclaimers and Safety Notes in this document, as well as
those in the product’s User Manual before installing, operating, or
maintaining this product.
Safety Notes • DO NOT open this product unless instructed. It contains no user
serviceable parts.
• DO NOT look at the light source when this product is on.
• DO NOT touch the product when it is operating because it may be hot.
• DO NOT leave any flammable material within 50 cm from this product
while operating or connected to the power outlet to minimize the risk of
fire.
• DO NOT mount this product overhead without using a safety cable.
• DO NOT submerge this product below 1 m for more than 30 minutes
(IP67). Regular outdoor operation is fine.
• DO NOT operate this product if you see damage on the housing, lenses,
or cables. Have an authorized technician replace the damaged parts.
• DO NOT connect this product to a dimmer or rheostat.
• ONLY connect this product to a grounded and protected circuit.
2
Ilumipod 48 IP Optic RGBW QRG
3
Ilumipod 48 IP Optic RGBW QRG
AC Power This product has an auto-ranging power supply that works with an input
voltage range of 100~240 VAC, 50/60 Hz.
Power Wiring You can connect the bare-ended IP67 rated power cable from the product to
an IP67 rated power connector or use an IP67 rated junction box. If using an
IP67 rated junction box, make sure to use IP67 rated conduit.
Power Cable Connection Wire (US) Wire (Europe) IP67 Pin
Table AC Live Black Brown 1
AC Neutral White Blue 2
AC Ground Green/Yellow Green/Yellow 3
AC Power
Junction
Box Wiring
4
Ilumipod 48 IP Optic RGBW QRG
DMX You can connect the bare-ended IP67 rated signal cable from this product to
Connection two IP67 rated signal connectors (DMX in and DMX Out) or use an IP67
rated junction box. If using an IP67 rated junction box, make sure to use
IP67 rated conduit.
To provide a signal for this product, you can connect the bare-ended IP67
rated signal cable from the product to two IP67 rated signal connectors
Signal Wiring
(DMX in and DMX out) or use an IP67 rated junction box. If using an IP67
rated junction box, make sure to use IP67 rates.
The signal cable must match or exceed the electrical characteristics of
the Belden® 9841 cable for EIA RS-485 applications. You can also use
CAT 5, CAT 5e, or CAT 6.
5
Ilumipod 48 IP Optic RGBW QRG
Installation Before installing this product, read the Safety Notes at the beginning of the
Ilumipod 48 IP Optic RGBW User Manual and follow the installation
procedures.
This product comes with ONE (1) adjustable bracket to mount it on any
firm, non-flammable surface, whether horizontally or vertically, on the floor
or hanging from a truss.
Mounting Diagram
Overhead Mounting
Floor Mounting
6
Ilumipod 48 IP Optic RGBW QRG
Start Address To ensure full access to all channels in each DMX mode, the highest
recommended DMX addresses are as follows:
Mode Address Mode Address Mode Address
STAG 502 AR1.D 509 HSV 510
ARC1 510 AR2.S 508 AR2D 507
7
Ilumipod 48 IP Optic RGBW QRG
Menu Options
st
1 Level Programming Levels Description
R (red)
G (green) Combines red, green, blue, and white to form a
000~255
STAT b (blue) custom color
w (white)
ST (strobe) 00~20 Strobe frequency (0~20 Hz)
AT.1~10 Selects any of the 10 auto programs
AUTO
PR.1~10 Selects any of the 10 custom (editable) programs
dMX Operates with a DMX controller
RUN
SLAV Operates with a master fixture
dMX d.001~512 Sets the DMX starting address
STAG 11 channels (RGBW, D, S, CM, A, AS, DS, ID)
ARC.1 3 channels (RGB)
AR1.D 4 channels (RGB, D)
PERS ARC.2 4 channels (RGBW)
AR2.d 5 channels (RGBW, D)
AR2.S 6 channels (RGBW, D, S)
HSV 3 channels (hue, saturation, value)
Id Id.01~66 Assigns an ID address to the fixture
R (red)
G (green) Combines red, green, blue, and white to form a
000~255
b (blue) custom color
PR. SC.
EdIT w (white)
01~10 01~30
Sb (strobe) 00~20 Strobe frequency (0~20 Hz)
T (time) Step duration
000~255
F (fade) Fade duration
NORM Disables HyperColor™ mode
Pow (upload)
HIGH Enables HyperColor™ mode
UPLd (upload) Uploads custom programs to another fixture
<Password>
REST (reset) Resets the fixture to factory settings
Id (ID addressing) ON/OFF Turns ID addressing on or off
SET
OFF Max output when RGBW faders are at 255
RGbw
RGbw (RGB to white) Pre-set output when RGBW faders are at 255
(color calibration)
UC (Universal Color) Output matches that of older fixtures
dIM OFF Makes dimmer curve linear
(dimmer speed) dIM1~4 Changes the dimmer curve (fast slow)
R (red)
wT.01~11 G (green) Modifies the white temperature used in the
CAL1 000~255
(White temperature) b (blue) macros channel (TOUR, channel 6)
w (white)
R (red)
RGbw Modifies the white color used when SET >
CAL2 G (green) 000~255
(RGB to white) COLOR > RGbw is active
b (blue)
KEY ON/OFF Turns the password on or off
8
Ilumipod 48 IP Optic RGBW QRG
DMX Values
STAG
Channel Function Value Setting
1 Dimmer 000 255 0~100%
2 Red 000 255 0~100%
3 Green 000 255 0~100%
4 Blue 000 255 0~100%
5 White 000 255 0~100%
000 005 No Function
006 020 HyperColor™ Mode (only in Normal power mode)
021 030 No Function
031 050 R: 100% G: 0~100% B: 0%
051 070 R: 100~0% G: 100% B: 0%
071 080 R: 0% G: 100% B: 0~100%
081 090 R: 100% G: 0% B: 100~0%
091 110 R: 0% G: 100~0% B: 100%
111 130 R: 0~100% G: 0% B: 100%
131 150 R: 100% G: 0% B: 100~0%
151 170 R: 100% G: 0~100% B: 0~100%
Color Macro + White 171 190 R: 100~0% G: 100~0% B: 100%
6
Balance 191 200 R: 100% G: 100% B: 100% W: 100%
201 205 White 1: 3200 K
206 210 White 2: 3400 K
211 215 White 3: 4200 K
216 220 White 4: 4900 K
221 225 White 5: 5600 K
226 230 White 6: 5900 K
231 235 White 7: 6500 K
236 240 White 8: 7200 K
241 245 White 9: 8000 K
246 250 White 10: 8500 K
251 255 White 11: 10000 K
000 010 No Function
7 Strobe
011 255 0~20 Hz
000 020 No Function
021 030 Auto 1
031 040 Auto 2
041 050 Auto 3
Auto + Custom 051 060 Auto 4
8
Programs 061 070 Auto 5
071 080 Auto 6
081 090 Auto 7
091 100 Auto 8
101 110 Auto 9
9
Ilumipod 48 IP Optic RGBW QRG
STAG (cont.)
Channel Function Value Setting
111 120 Auto 10
121 130 Custom 1
131 140 Custom 2
141 150 Custom 3
151 160 Custom 4
Auto + Custom
8 161 170 Custom 5
Programs
171 180 Custom 6
181 190 Custom 7
191 200 Custom 8
201 210 Custom 9
211 255 Custom 10
9 Auto Speed 000 255 0~100% (Only when Auto 01~10 active)
000 009 Linear dimming curve
010 069 Nonlinear dimming curve 1 (fastest)
10 Dimmer Speed 070 129 Nonlinear dimming curve 2
130 189 Nonlinear dimming curve 3
190 255 Nonlinear dimming curve 4 (slowest)
000 009 All IDs 212 ID 23 235 ID 46
010 019 ID 1 213 ID 24 236 ID 47
020 029 ID 2 214 ID 25 237 ID 48
030 039 ID 3 215 ID 26 238 ID 49
040 049 ID 4 216 ID 27 239 ID 50
050 059 ID 5 217 ID 28 240 ID 51
060 069 ID 6 218 ID 29 241 ID 52
070 079 ID 7 219 ID 30 242 ID 53
080 089 ID 8 220 ID 31 243 ID 54
090 099 ID 9 221 ID 32 244 ID 55
100 109 ID 10 222 ID 33 245 ID 56
11 ID Addressing 110 119 ID 11 223 ID 34 246 ID 57
120 129 ID 12 224 ID 35 247 ID 58
130 139 ID 13 225 ID 36 248 ID 59
140 149 ID 14 226 ID 37 249 ID 60
150 159 ID 15 227 ID 38 250 ID 61
160 169 ID 16 228 ID 39 251 ID 62
170 179 ID 17 229 ID 40 252 ID 63
180 189 ID 18 230 ID 41 253 ID 64
190 199 ID 19 231 ID 42 254 ID 65
200 209 ID 20 232 ID 43 255 ID 66
210 ID 21 233 ID 44
211 ID 22 234 ID 45
10
Ilumipod 48 IP Optic RGBW QRG
ARC 1
Channel Function Value Percent/Setting
1 Red 000 255 0~100%
2 Green 000 255 0~100%
3 Blue 000 255 0~100%
ARC 1 + D
Channel Function Value Percent/Setting
1 Dimmer 000 255 0~100%
2 Red 000 255 0~100%
3 Green 000 255 0~100%
4 Blue 000 255 0~100%
ARC 2
Channel Function Value Percent/Setting
1 Red 000 255 0~100%
2 Green 000 255 0~100%
3 Blue 000 255 0~100%
4 White 000 255 0~100%
ARC 2 + D
Channel Function Value Percent/Setting
1 Dimmer 000 255 0~100%
2 Red 000 255 0~100%
3 Green 000 255 0~100%
4 Blue 000 255 0~100%
5 White 000 255 0~100%
ARC 2 + S
Channel Function Value Percent/Setting
1 Dimmer 000 255 0~100%
2 Red 000 255 0~100%
3 Green 000 255 0~100%
4 Blue 000 255 0~100%
5 White 000 255 0~100%
000 004 No Function
6 Strobe
005 255 0~20 Hz
11
Ilumipod 48 IP Optic RGBW QRG
12