The document outlines the electrical plans and specifications for a project, including details on existing conditions, electrical symbols, and load calculations. It emphasizes compliance with the National Electrical Code (NEC 2020) and includes notes for installation and verification by the electrical contractor. Key components include circuit breakers, wiring specifications, and the requirement for tamper-proof receptacles and arc fault circuits.

Uploaded by

erlingarielgs
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
28 views1 page

E100-Electrical Plans - 20250114164310734

The document outlines the electrical plans and specifications for a project, including details on existing conditions, electrical symbols, and load calculations. It emphasizes compliance with the National Electrical Code (NEC 2020) and includes notes for installation and verification by the electrical contractor. Key components include circuit breakers, wiring specifications, and the requirement for tamper-proof receptacles and arc fault circuits.

Uploaded by

erlingarielgs
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

JOHN D.

YOUNGMAN
EXISTING NOT IN SCOPE ELECTRICAL SYMBOL SCHEDULE PER PLANS
120/240 V 1Ø 3W NEMA 3R
ARCHITECT AR 9601
3-3/0 CU THAN OR 150 AMP 10K A/C ENCLOSED 421 East SR 434, Suite 1015,
EQUAL IN 2" CONDUICT CIRCUIT BREAKER OR EQUAL Longwood, Florida 32750
2 1-4 CU THAN OR EQUAL WALL SWITCH
IN 2" CONDUICT
PANEL A

EXISTING STAIR NOT IN SCOPE


120/240 V 1Ø 3W
POWER Co. DOUBLE SWITCH

GFI
PANEL 100 AMP M.B. FLU IT MOUNT 2
METER
A
DISP.
EXISTING BEDROOM
3 THREE WAY SWITCH
#12 & #14 CU TO LIGHTS & OUTLETS

GFI
#10 CU TO WATER HEATER
D
#8 CU TO RANGE DIMMER
RUB 1 #4 CU COPYRIGHT ©

GFI
TO 2-5/8x8 GROUND FINISHED FLOOR JOHN YOUNGMAN, ARCHITECT.
ROD/AND OR COLD RECESSED LIGHT FIXTURE THIS OR ANY OTHER DOCUMENT SHALL NOT
SCOPE OF WORK: WATER PIPE
EXTERIOR PORCH BE COPIED, ALTERED, REPRODUCED WITH OUT
PREWIRE THE WRITTEN CONSENT
ENCLOSURE

GFI
FAN/LIGHT UNDERGROUND OF JOHN YOUNGMAN, ARCHITECT.
WALL MOUNTED LIGHT FIXTURE
SERVICE CABLE 3-3/0 CU THWN OR EQUAL IN 2" CONDUICT
BY F.P.C. 1-4 CU THWN OR EQUAL IN 2" CONDUICT
MINI SPLIT
SELECTED BY
OTHERS ELECTRICAL RISER DIAGRAM

NOT IN SCOPE 150 AMP-UNDER GROUND N.T.S.


WP

GFI
UNIT 1A CEILING FAN
GFI NOTE:
ALL ELECTRICAL MATERIALS AND INSTALLATIONS
776 SQ FT

2
SHALL COMPLY WITH APPLICABLE PROVISIONS OF
THE NATIONAL ELECTRICAL CODE NEC2020 EDITION
EXISTING LIVING ROOM

ELECTRICAL NOTES: SMOKE DETECTOR


SCO2 BEYOND 2 DIMENSIONS, INC
EXISTING THE DWGS. ARE DIAGRAMMATIC &. INDICATE THE GENERAL THE ELECTRICAL WORK. ANY DISCREPANCIES ON THE CALLED TO THE
DESIGNER's ATTENTION PRIOR OF WORK. DO NOT SCALE ELECTRICAL DRAWINGS. ALL WORK SHALL BE DONE IN ACCORDANCE PLANNING, DESIGN, DRAFTING,
BEDROOM SMOKE-CARBON MONO DETECTOR PROJECT COORDINATION

2
WITH THE LATEST EDITION OF THE NATIONAL ELEC. CODE &. ALL CODES. REGULATIONS &. RESTRICTIONS HAVING JURISDICTIONS.
CONTRACTOR SHALL VERIFY WITH POWER COMPANY THE LOCATION OF SERVICE AND SHALL LOCATE METER AND PANEL AS SCO2
REQUIRED. CONTRACTOR SHALL VERIFY ALL CONDUCTORS AND BREAKERS W/ EQUIP. MFG. SPECIFICATIONS. ELECTRICAL SYSTEM 421 East SR 434, Ste. 1015, Longwood, Florida 32750
PH. 407-781-6611
2 SHALL BE GROUNDED. PROVIDE PROPER SIZE &. TYPE OF PROTECTION DEVICES TO MATCH EQUIPMENT BEING SERVED. LOAD DATA
SINK DISPOSAL UNDER SINK [email protected]
BY OTHERS. VERIFY ALL EQUIP. & PANEL SIZES PRIOR TO ORDERING. ALL MATERIALS SHALL BE NEW AND BEAR U.L. LABELS. WHERE
APPLICABLE. ALL WORK SHALL BE DONE BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER.
CIRCUITS SHOWN ON PLANS ARE TO DETERMINE LOAD DATA AND PANEL SIZES. THE CONTRACTOR SHALL PROVIDE CIRCUITS AND
REQUIRED ROUTING OF CONDUITS TO SUIT JOB CONDITIONS AND BALANCE LOADS. FIXTURES AS SELECTED BY OWNER. THE
ELECTRICAL CONTRACTOR SHALL COORDINATE THE EXACT LOCATION OF ALL H.V.A.C. EQUIPMENT AND THEIR GIVEN LOAD WITH EXTERIOR FLOOD LIGHTS
THE MECHANICAL CONTRACTOR BEFORE ROUGHING-IN FOR PROPER POWER AND WIRING CONTROL LAYOUT & INSTALLATION.
CONTRACTOR SHALL VERIFY EXACT LOCATIONS OF FIXTURES AND OUTLETS AT JOB SITE BEFORE ROUGHING. SMOKE DETECTORS

1910 HARDING ST. ORLANDO FL.


SHALL BE HARD WIRED AND SHALL BE PROVIDED W/VISIBLE "POWER ON INDICATOR" AND A TEST BUTTON WITH BATTERY BACKUP
SYSTEM. MULTIPLE DETECTORS MUST BE INTERCONNECTED. ALL ELECTRICAL SWITCHES SHALL BE 48" A.F.F. AND ALL WALL DOOR BELL
RECEPTACLES
SHALL BE 12" A.F.F. UNLES NOTED OTHER WISE ON ELECTRICAL PLANS. ELECTRICAL CONTRACTOR TO COORDINATE ALL LOW
EXISTING VOLTAGE WITH OTHER TRADES AND GENERAL CONTRACTOR. DOOR CHIMES
ELEC. PANEL

EXTERIOR ALTERATION AT
ELECTRICAL PANEL
2 ELECTRICAL RISER
MINI SPLIT SELECTED BY OTHERS E100 SCALE: 12" = 1'-0"
DISCONNECT SWITCH
REF. SHEET:
TD

1 FIRST FLOOR ELECTRICAL PLAN TELEPHONE/ DATA OUTLET


E100 SCALE: 1/4" = 1'-0"

ELECTRICAL PLANS
TV
REF. SHEET: A103 NOTE:
NOTE: ELECTRICAL PANEL SEE GENERAL NOTES AND SCHEDULES FOR DATA OUTLET/ CABLE OUTLET
SEE GENERAL NOTES AND SCHEDULES FOR ADDITIONAL RISER AND ADDITIONAL RISER AND ELECTRICAL INFORMATION.
2 LOAD CALCULATIONS:
1/8/25 ELECTRICAL INFORMATION. DESIGN AND CONSTRUCTION TO CONFORM TO
DESIGN AND CONSTRUCTION TO CONFORM TO FBC ELECTRICAL (NEC 2020) (747 SQ FT) CURRENT ELECTRICAL CODE
150A, MAIN CIRCUIT BREAKER, DUPLEX CONVENIENCE OUTLET
NOTE: 120/240V, 1 PHASE, 3W, 22,000AIC NOTE:
PROVIDE TAMPER PROOF RECEPTACLES AND PROVIDE TAMPER PROOF RECEPTACLES AND
ARC FAULT CIRCUITS PER NEC 210.12(B) AND 406.11 ARC FAULT CIRCUITS PER NEC 210.12(B) AND 406.11

STATUS
LOAD INFO. CK CB WIRE VA
42"H DUPLEX OUTLET @ 42" ABOVE FINISH FLOOR
SEE FLOOR PLAN FOR ELECTRICAL EQUIPMENT AND LOCATION
NOTE:
REFRIGERATOR 2 20/1 12 1200 ELECTRICAL CONTRACTOR TO VERIFY
ALL LOAD AND CONDITIONS PRIOR TO
RANGE (ELECTRIC) 15:17 50/2 6 8,800 ORDER OR ERECTING ELECTRICAL 60"H DUPLEX OUTLET @ 60" ABOVE FINISH FLOOR

PROJECT ISSUED FOR:


DISHWASHER (GFI) 4 20/1 12 1,000 SUBPERMIT

DISPOSAL (GFI) 6 20/1 12 600


GRINDER (GFI) 8 20/1 12 1,000 GFI DUPLEX OUTLET W/ GROUND FAULT INTERRUPTER

SHEET TITLE
DRYER (GFI) 16:18 30/2 10 5,000

PROJECT:
WASHER (GFI) 10 20/1 12 1,500
WP
SMOKE DT. 11 20/1 12 * DUPLEX OUTLET WEATHER PROOF

BATH DEDICATED CIRCUIT (GFI) 13 20/1 12 * No. Description Date


2 COMMENTS 1/8/25
ELECTRIC WATER HEATER 19:21 30/2 10 5,000
220 VOLT OUTLET
SMALL APPLIANCES (2) 12,14 20/1 12 3,000

747 SQ FT LIGHTING/ RECEPT. 1,3,5,7 20/1 12 2,241


OUTLET TELEPHONE/ DATA
@ 3 WATTS

AHU - 1 23:25 50/2 6 5,000


CU-1 20:22 30/2 10 3,000
NOTE:
PROVIDE TAMPER PROOF RECEPTACLES AND
TOTAL CONNECTED VA 37,341 ARC FAULT CIRCUITS PER NEC 210.12(B) AND 406.11

VA LESS A/C LOAD DEM. 29,341 PROJECT. NUMBER On File


1ST 10,000 100% 10,000 SCALE
AS SHOWN
REMAINDER PER NEC-220-82 (B) 40% 19,341
DATE:
HEAT PUMP COMPRESSOR 100% 3,000 1/13/2025 12:34:19 PM

HEAT PUMP SUPPLEMENTAL DRAWN BY:


Author
ELEC HEAT 65% 3,250
CHECKED BY:
TOTAL LOAD VA 25,591
Checker
SHEET
VOLT 240 AMPS 107

NOTES:
E100
ALL 120 VOLT, SINGLE PHASE 15 AND 20 AMP BRANCHE CIRCUITS
THIS DOCUMENT HAS BEEN ELECTRONICALLY
SUPPLYING OUTLETS OR DEVICES INSTALLED IN DWELLING UNIT
SIGNED AND SEALED BY
KITCHENS, FAMILY ROOMS, DINING, LIVING, ROOMS, PARLORS, JOHN D. YOUNGMAN, ARCHITECT AR9601
OFFICES, LIBRARIES, DENS, BEDROOMS, SUNROOMS CLOSETS, ON DATE/ TIME STAMP SHOWN USING
HALLWAYS, LAUNDRY, AREAS, OR SIMILAR ROOMS OR AREAS SHALL A DIGITAL SIGNATURE.
BE PROTECTED BY AN ARCH-FAULT CIRCUIT INTERRUPTER PER NEC
210-12 REQUIREMENTS PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED
AND THE SIGNATURE MUST BE VERIFIED.