manual nss
manual nss
▲ Do not use NSS weighing scale in hazardous area! Do not use it within
areas classified as hazardous division 1/2 or zone 0/1/2/21/22
because of combustible or explosive atmospheres.
DANGER!
Disposal
In conformance with the European Directive 2002/96/EC on Waste Electrical and Electronic
Equipment (WEEE), this device may not be disposed of in domestic waste. This also applies to
countries outside the EU as per their specific regulations.
Please dispose of this product in accordance with local regulations at the collecting point
specified for electrical and electronic equipment.
If you have any questions, please contact the responsible authority or the distributor from
which you purchased this indicator.
Should this scale be passed on to other parties (for private or professional use), the content of
this regulation must also be related.
The scale has a rechargeable internal battery. The battery contains heavy metals. Please
observe the local regulations on the disposal of environmentally hazardous materials.
All Rights Reserved, any copying, reproducing, republishing, posting, distributing by any means is prohibited without permission of
our company
1
Index
Technical Specifications 3
Model Identification 3
Packing List 3
Load Cell 4
Keyboard 4
Application 4
Weighing 4
Checkweigh 4
Multi-range & Multi-interval 5
Parameters Configuration 5
UF-1 Internal Counting (A/D) 5
UF-2 Checkweigh Setting 5
UF-3 Auto Switch Off 5
UF-4 Standby Mode (LED version) | Backlight Set (LCD version) 5
UF-5 Hold (LED version) | Response Speed (LCD version) 6
UF-6 Hold (LED version) | Auto Zero Track (LCD version) 6
UF-7 Response Speed (LED version) | Gravity (LCD version) 6
UF-8 Auto Zero Track (LED version) | RS232 (LCD version, no function) 6
UF-9 Gravity (LED version) 7
User Calibration 7
ECF-1 Calibration of Zero and weight 7
ECF-2 Calibration of Zero 7
ECF-3 Calibration of weight 7
Warranty 7
2
1. Technical Specifications
Model NSS
Enclosure Type SUS304
Product Dimension 330 x 290 x 110mm
Shipping Weight 4.8kg
Accuracy Class III
Display Resolution 1/6,000
Capacity 3 | 6 | 15 | 30kg
Division 0.5g | 1.0g | 2.0g | 5.0g
Units Kg, g , lb, etc.
Display LED or LCD
Power 100-240V – 12V1Ah AC/DC adaptor
Battery 6V4Ah
Protection IP67
Operating Temperature -10 ~40
Storage Temperature -25 ~55
Relative humidity 85%Rh non-condensing
2. Model Identification
Model: NSS -E UK 0 0
Corresponding: A B C D E
3. Packing List
After the scale received, please open the box carefully and check the following items included:
- Scale x1
- Power adaptor x1
- Manual x1
3
4. Load Cell
PCB Load Cell
+
++E………….………Excitation +
+S………….………Signal +
SHIELD…….…….Shield
-S ………….………Signal –
-E………….………Excitation –
5. Keyboard
On - Switch on the scale
Zero - Zero the scale, when the weight less than +2%F.S.
Tare - Tare function, to deduct the weight of a container
Move the digit to right during program set
Off - Keep pressing the key for 3 seconds to switch off the scale
In the below contents, use key [ON] [OFF] [FN] [UNIT] represent as above buttons.
6. Applications
6.1 Weighing
Switch on the scale and wait self-checking finish, if the scale display 0, now it’s ready for weighing; if the
scale doesn’t display 0, press [ON] key to zero the scale.
Put the commodity on the pan of the scale, it will show the weight.
6.2 Checkweigh
The user can configure the over and under limit of the weight placed on the pan, refer to UF-2 parameters
setting, if the weight under the limit, it will turn on the Hi LED light (for LCD version, the backlight change to be
in yellow-green color), if the weight over the limit, it will turn on the Lo LED light (for LCD version, the backlight
change to be in magenta color), and if the weight within the range, it will turn on the OK LED light (for LCD
version, the color change to be in green).
4
6.3 Multi-range & Multi-interval
The standard version with only one range and division, but the scale can be set as multi-range or
multi-interval, refer to LF-2 parameters setting.
If it set to be multi-range or multi-interval, it will work as below:
Multi-interval: 0 – 50%F.S. with the interval as it selected (A), 50%-100%F.S. with the next interval (B),
when the weight decrease, it will change from B to A when the range change from above 50%F.S. to less
50%F.S.
Multi-range: 0 – 50%F.S. with the interval as it selected (A), 50%-100%F.S. with the next interval (B), if the
weight decrease from above 50%F.S., it will use interval B until the scale is empty.
7. Parameters Configuration
To access the configuration of the parameters, the scale must be in zero condition, and press the [FN] key
to enter and press it again to select the setting from UF-1 to UF-9 (LCD version till UF-8), press [UNIT] key
to quit.
8 User Calibration
When the scale in normal weighing mode, the user can press [FN] to enter and select ECF setting from
ECF-1 to ECF-3
The warranty period is one year starting with delivery of the scale and it covers all manufacturing and
materials defects, during this period, we will be in charge of the repairing of the scale and parts
replacement free (battery not covered). The warranty does not include the damages caused by overload or
wrong use, also it does not cover the transportation cost.