0% found this document useful (0 votes)
8 views7 pages

NO-Contact LiquidLevelSensor

The document describes the XKC-Y26-XXX non-contact liquid level sensor, which utilizes advanced signal processing technology to detect liquid levels in non-metal containers without direct contact. It features high sensitivity, stability, and a wide application range, capable of detecting various liquids, including corrosive substances, in high-pressure environments. The sensor is easy to install and includes a one-year warranty with specific terms for service and limitations.

Uploaded by

mariusforlive
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
8 views7 pages

NO-Contact LiquidLevelSensor

The document describes the XKC-Y26-XXX non-contact liquid level sensor, which utilizes advanced signal processing technology to detect liquid levels in non-metal containers without direct contact. It features high sensitivity, stability, and a wide application range, capable of detecting various liquids, including corrosive substances, in high-pressure environments. The sensor is easy to install and includes a one-year warranty with specific terms for service and limitations.

Uploaded by

mariusforlive
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

NO-Contact Liquid Level Sensor

Descriptions
The intelligent non-contact liquid level sensor (hereinafter
referred to as the liquid level sensor) adopts advanced
signal processing technology and high-speed signal
processing chip, which breaks through the influence of
container wall thickness and realizes a true non-contact
type of liquid level height in a closed container Detection.
The liquid level sensor (probe) is installed on the upper
and lower sides of the outer wall of the container to be
measured (the high and low levels of the liquid level).
The non-metallic container does not need to be opened,
and the installation is simple and does not affect produc-
tion. It can detect the liquid level of various liquid toxic
substances, strong acids, strong alkalis and various liq-
uids in high-pressure airtight containers. The liquid level
sensor has no special requirements for the material of
the liquid medium and the container, and can be widely
used. XKC-Y26-XXX series products are specially devel-
oped for non-metallic pipeline liquid level detection

Product Features
1. XKC-Y26-XXX non-contact liquid level sensor is suitable for all kinds of non-metal containers. The
product detects the liquid through the detection signal through the non-metal container and the outer
wall of the pipeline, without direct contact with the liquid. It is corroded by strong acids and alkalis
and other corrosive liquids, and is not affected by scale or other debris, and it can be completed to
detect whether there is liquid inside the container or pipeline.
2. Product design intelligent liquid level reference adjustment and liquid level memory function, liquid
level status display mode, can realize multi-point series connection control mode. It can support high
and low level output, NPN, PNP signal output control (please refer to the manufacturer’s instructions
when selecting the model).
3. The detection liquid level is accurate and stable, and cold, hot and boiling liquids can be detected.
4. Pure electronic circuit structure, non-mechanical working mode, stable performance and long last-
ing service life.
5. High stability, high sensitivity, strong anti-interference ability, free from external electromagnetic
interference, special treatment for power frequency interference and common mode interference, to
be compatible with all 5~24V power adapters on the market.
6. Wide range of application, strong sensing ability, can penetrate and detect the liquid level in vari-
ous non-metallic containers and pipes, such as plastic, glass, ceramics and other containers. The
thickness of the sensing pipe wall can reach 20mm; it can be applied to various curved surfaces. ,
Arc, cylindrical and other irregular containers or pipeline liquid level detection.
7. Wide voltage range (5~24V), suitable for connecting various circuits and product applications

Product Applications
The intelligent non-contact liquid level sensor uses the inductive capacitance of water to detect
the presence of liquid. When there is no liquid close to the sensor, the sensor has a certain static
capacitance to the ground due to the presence of distributed capacitance on the sensor. When the
liquid level is slow When the sensor is slowly raised, the parasitic
capacitance of the liquid will be coupled to the static capacitance of the sensor, making the ca-
pacitance value of the sensor larger. The changed capacitance signal is then input to the control
IC for signal conversion, and the changed capacitance is converted into a circuit signal When the
amount of change exceeds a certain threshold, it is judged that the
liquid level has reached the sensing point.

Product parameter

Project name Parameters


Product model
Supply voltage(Vin)
Output mode
electric current
The output voltage(high pulse)
The output voltage(low pulse)
The output current
Response time
Working temperature
Outer diameter of pipe D(mm)Sense container wall or tube
wall thickness L(mm)
Outer diameter of pipe D(mm) Sense container wall or
tube wall thickness L(mm)
D≥100 20 ± 2
100>D≥80 15 ± 2
Sensor sensitivity
80>D≥60 12 ± 1.5
60>D≥40 7 ± 1.0
40>D≥30 5 ± 1.0
30>D≥20 3 ± 1.0
20>D≥10 1.5 ± 0.5
Applicable pipe diameter range ≥10mm
Liquid level accuracy ±1.5mm
Humidity 5%~100%
Material PC V0 Fireproof material
Waterproof performance IP67
Safety standard certification CE
Environmental protection certifi- ROHS-2.0
cation

Product parameter

NPN output interface—————Model: XKC-Y26-NPN (DC 5-12V)


NPN output interface—————Model: XKC-Y26-NPN (DC24V)
Clearance requirements
Requirements for the clearance between the contact surface of the sensor (or probe) and the outer
wall of the container The contact surface of the sensor (or probe) and the outer wall of the contain-
er should be tightly pasted with AB or other solid-resistant glue. If there are special requirements,
the gap should be less than 0.5mm, preferably no gap, otherwise it may affect the measurement
accuracy .

Installation method

Install into a flat cistern as shown in the figure below


Install to the non-metal water pipe type as shown below

The height of the sensed liquid level is related to the sensitivity of the sensor. The higher the sensi-
tivity, the lower the sensed liquid level
Note: The liquid level is sensed in the upper and lower edges of the sensor, which is normal.
The induction sheet can be tightly attached to the pipe with strong glue, or it can be tightened with
the pipe with a nylon cable tie. There should be no metal parts in the part where the probe is in-
stalled, so as not to affect the detection. Pipes made of non-metallic materials with a smooth sur-
face, uniform thickness, tight material, and good insulation performance; such as glass pipes, plastic
pipes, PC/PVC/PPR pipes, non-absorbent ceramic pipes, acrylic pipes, rubber pipes, etc. or their
composites Pipes made of materials
Sensitivity adjustment
If the non-contact liquid level sensor cannot detect or the detected liquid level deviates from the Y26
sensor, The sensitivity knob can be adjusted with a small screwdriver. Setting method:
1. Turn counterclockwise to increase sensitivity.
2. Turn clockwise to lower the sensitivity
Product size

Y26 wiring diagram of various models


NPN output drives small electric relays (coil current ≤ 100mA) Product Applications:
1.When the black line is suspended, it is normally open output:
When liquid is sensed, the transistor is turned on and closed, and the relay is energized and
closed;When no liquid is sensed, the transistor will be cut off and the relay will not be closed when
the power is turned off.
2.When the black wire is grounded (connected to the negative pole of the power supply 0V), it is
normally closed output:When liquid is sensed, the transistor will be cut off and the relay will not
be closed when the power is turned off;When no liquid is sensed, the transistor is turned on and
closed, and the relay is energized and closed.

Other matters needing attention


(1) The viscosity of the measured liquid medium
When the dynamic viscosity is less than 10mPaS, it is measured normally. 10mPaS<dynamic
viscosity<30mPaS may affect the detection. When the dynamic viscosity is greater than 30mPaS, it
cannot be measured because a large amount of liquid adheres to the container wall.
(2) Note: As the temperature increases, the viscosity decreases, and most high-viscosity liquids are
more affected by temperature. Therefore, pay attention to the influence of liquid temperature when
measuring viscous liquids.
(3) Pay attention to keeping the level gauge clean, try to prevent corrosion and avoid violent colli-
sions and blows from
other objects.
(4) During outdoor installation, avoid direct sunlight and rainwater directly flowing to the main body
of the level gauge, and keep away from high heat sources and pay attention to ventilation. If the
ambient temperature exceeds the rated temperature, corresponding cooling protection measures
should be taken.
(5) When the ambient temperature is lower than the normal operating temperature range of the
level gauge, an instrument protection box or other protective rain cap devices can be used for anti-
freeze protection, and pay attention to keeping the level gauge dry. The sensor should be regularly
maintained and inspected. (The detection time interval is determined by the use unit according to
the specific situation).

Troubleshooting
Product warranty terms and instructions
(A) .Warranty service
1. Warranty period maintenance: from the date of purchase, the product host has a one-year free
warranty. The company has the right to decide to repair or replace the faulty part. If it is replaced, the
replacement part may be a new device or a repair product of the same category, function, and qual-
ity. The replaced faulty part belongs to the company; the product Resale and repair do not affect the
warranty period. Products that have been repaired or replaced continue to enjoy the
original remaining warranty period service. If the warranty period is less than three months after the
repair, the repaired or replaced part shall be shipped from the date of delivery Warranty for three
months; all products of the company are guaranteed for repair.
2. Loss upon arrival (DOA) replacement: From the day of purchase, you can enjoy a free replace-
ment service within 7 other hardware failures identified by our company’s engineers remotely or
locally.
(B). Applicable limitations of warranty
For the following situations, the company does not assume warranty responsibility:
1. The product is out of warranty; the surface of the product is fragile and damaged; the appearance
of the product is seriously damaged, installation/use in abnormal environment, unauthorized disas-
sembly and repair/modification, external power supply damage and other abnormal damage;
2. Damage caused by incorrect installation and use of the product by the user not following the re-
quirements of the manual;
3. Damage caused by natural disasters and human negligence (fire, lightning, flooding, impact, etc.).
(C) .Accessories and consumables are not covered by the warranty.
(D) .Non-free warranty service Within two years of product purchase, for non-warranty product (in-
cluding components) failures and damages, you can choose paid maintenance services (free labor
costs), and we will charge the transportation cost of repairing parts and accessories according to the
actual situation.