NitriteMonitor
NitriteMonitor
Results of the analysis are displayed on the LCD display and the data is available
externally as a 4-20mA signal for use by a dosing management system such as an
Aquanet AQ652, AQ655 or for inclusion into a ships engine room management system.
Data is also available in raw digital format for those companies wishing to write their
own protocol handler for OEM software applications.
Calibration:
The calibration potentiometer is available through the front panel and following a cooling
water sample drop test the potentiometer can be used to adjust the LCD to agree with
the test results.
The LCD continuously displays the level of Nitrite and the sensor temperature.
Power Source:
The user provides an external 12-15 V dc power cube
SPECIFICATIONS
Cables (The unit has 3 wire connections) Alarms Instrument status via LCD
Red +12– 15Vdc
Green 0 Vdc
Yellow 4-20mA output
Enclosure
Rating IP 65
Connections Double Ferrule 6mm Stainless compression Dimensions 130 x 56 x 50 mm
Simple monitor with manual dosing and output signal optionally connected to ships computer management system