Environment
Ambient temperature
Activity °C (°F)
Operation -10 – 40 (14 – 104)
Operation (de-rated) maximum 50 (122)
Storage -40 – 60 (-40 – 140)
Altitude
Maximum altitude for de-rated operation is 1000 m (3281 ft).
De-rating above 1000 m (3281 ft) is 1% per 100 m (32.8 ft).
Maximum altitude with UL approval is 2000 m (6562 ft)
Maximum altitude without UL approval is 4000 m (13123 ft)
Humidity
The relative humidity must not exeed 95% (non condensing)
Input voltage
Model Number Supply Voltage Phases Frequency (Hz) Maximum phase
imbalance
SRC311-X-X-XXXXX-XX 200 – 240 V +10/-15% 1 50, 60 3%
3
380 – 480 V +10/-15% 3
Depending upon the model and power rating, the drives are designed for direct
connection to the following supplies
For input supplies which have supply imbalance greater than 3% an input line reactor is
recommended. Alternatively, the drives can be operated as a single phase supply drive
with 50% de-rating.
Voltage (V) Ratings kW (HP) Maximum supply voltage Vrms Maximum supply short-circuit
(AC) current Arms (AC)
230 0.37 – 18.5 (0.5 – 25.0) 240 5
22.0 – 90.0 (30.0 – 120.0) 10
400/460 0.75 – 37.0 (1.0 – 50.0) 500/600 5
45.0 – 132.0 (60.0 – 175.0) 10
160.0 (210.0) 18
IP55
Table 4: 200 – 240 V (+ / -10%) 3–phase input, 3–phase output
Cable length
The maximum cable length is 100 m (328 ft). Screened cables must be used.
The PWM output switching from any inverter using a long motor cable can cause an
increase in the voltage at the motor terminals, depending on the cable length and
inductance. The rise time and peak voltage can affect the service life of the motor. Flygt
recommend using an output choke for motor cable lengths of 50 m or more to ensure
good motor service life.
For UL-compliant installation, use Copper wir4 with a minimum insulation temperature
rating of 75°C (167°F). When using fuses type must be Class CC or Class J
Dimensions
Frame size 2 – 3
D A
B
I
J
E
H F
G
Drive A B C D E F G H I
Size
Lengt mm in mm in mm in mm in mm in mm in mm in mm in mm in
h
2 257. 10.1 220. 8.67 200. 7.87 28.5 1.12 238. 9.37 188. 7.40 176. 6.93 4.2 0.17 8.5 0.33
0 2 0 0 0 0 0
3 310. 12.2 276. 10.8 251. 9.90 33.4 1.31 256. 10.0 210. 8.29 197. 7.78 4.2 0.17 8.5 0.33
0 0 5 9 5 0 8 5 5
Frame size 4 – 7
H
I
A C B
D
F G E
Drive A B C D E F G H I
Size
Lengt mm in mm in mm in mm in mm in mm in mm in mm in mm in
h
4 440. 17.3 418. 16.4 423. 16.6 8.0 0.31 230. 9.06 173. 6.81 110. 4.33 4.25 0.16 7.5 0.29
0 2 0 6 0 5 5 0 0 0 7 5
5 540. 21.2 515. 20.2 520. 20.4 8.0 0.31 270. 10.6 235. 9.25 175. 6.89 4.25 0.16 7.5 0.29
0 6 0 8 0 7 5 0 3 0 0 7 5
6 865. 34.0 830. 32.6 840. 33.0 10.0 0.39 340. 13.3 290. 11.4 200. 7.87 5.50 0.21 11.0 0.43
0 6 0 8 0 7 4 0 9 0 2 0 7 3
7 1280 50.3 1245 49.0 1255 49.4 10.0 0.39 370. 14.5 330. 12.9 200. 7.87 5.50 0.21 11.0 0.43
.0 9 .0 2 .0 1 4 0 7 0 9 0 7 3
Torque values
Screw Frame size Torque Nm (lbs-in.)
Control terminal All 0.8 (7)
Power terminal 2–3 1 (8.85)
4 1.2 – 1.5 (10.6 – 13.2)
5 2.5 – 4.5 (22.5 – 39.8)
6–7 8 (70.8)
Mounting clearance
X Minimum 200 mm (7.87 in)
X
Y Minimum 10 mm (0.349 in)
Y Y
NOTICE:
The operating ambient temperature of the drive must be maintained.
Control terminal
+24 V
RL1-C
DI 1
RL1-NO
DI 2
RL1-NC
DI 3
+10 V
RL2-A
AI 1
RL2-B
AI 2
0V
AO1
STO - 0V
STO + AO2
Communication
The unit is equipped with an RJ45 connector. The connection is used to set up a network
via a wired connection. The connector contains two independent RS485 connections and
both can be used simultaneously.
Do not connect directly into an Ethernet port. The voltage destroys the Ethernet device.
1 2 3 4 5 6 7 8
1. Not used
2. Not used
3. 0V
4. Optibus/Remote Keypad/PC connection -
5. Optibus/Remote Keypad/PC connection +
6. 24 V Remote Keypad power supply
7. RS485- Modbus RTU/BACnet
8. RS485+ Modbus RTU/BACnet
Options
External Keypads and Optistick
• OLED External Keypad
• Optidrive P2/E2 Optistick
Pluggable modules
• Extended I/O
• Extended relay
• TTL Encoder Module
• Ethernet IP Module
• Profibus Module
• Devicenet Module
Xylem Water Solutions AB Visit our Web site for the latest version of this document and
more information
Gesällvägen 33
174 87 Sundbyberg The original instruction is in English. All non-English
instructions are translations of the original instruction.
Sweden
Tel. +46-8-475 60 00 © 2011 Xylem Inc
Fax +46-8-475 69 00
http://tpi.xyleminc.com
882877_1.0_en.US_2011-12_TS_SRC311