0% found this document useful (0 votes)
9 views8 pages

Datasheet PTM Ex

The PTM/Ex is a programmable pressure transmitter certified for ATEX and IECEx, offering measuring ranges from 0 to 1000 bar with high accuracy and flexibility. It features piezoresistive technology, adjustable settings via PC software, and various certifications for safety and reliability. The device is suitable for both static and dynamic pressure measurements and has a robust design for harsh environments.

Uploaded by

irv.gut.2
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
9 views8 pages

Datasheet PTM Ex

The PTM/Ex is a programmable pressure transmitter certified for ATEX and IECEx, offering measuring ranges from 0 to 1000 bar with high accuracy and flexibility. It features piezoresistive technology, adjustable settings via PC software, and various certifications for safety and reliability. The device is suitable for both static and dynamic pressure measurements and has a robust design for harsh environments.

Uploaded by

irv.gut.2
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Pressure Transmitter - ATEX / IECEx certified

PTM/Ex - Programmable Pressure Transmitter

CUSTOMER BENEFITS
• Certificates: ATEX, IECEx, EAC, GOST, ABS, DNV, Lloyds
• Any measuring ranges between 0 ... 100 mbar and 0 ... 1000 bar available
• Static accuracies available to 0.1 %FS
• High flexibility due to scalable pressure range
• Hysteresis and repeatability better than 0.025 %
• Piezoresistive technology suitable for static and dynamic pressure measurements
• Adjustment of zero and span setting via PC software in the field
• Barometric pressure ranges available

Release: 10.80.0544.B - 2022.01


www.stssensors.com 1
Technical Specifications
PRESSURE MEASURING RANGE (BAR)
Pressure range 0 ... 0.1 to 0 ... 0.5 0 ... > 0.5 to 0 ... 2 0 ... > 2 to 0 ... 25
Overpressure (Proof) 3 bar 3 bar / 3 x FS 3 x FS
Burst pressure > 200 bar > 200 bar > 200 bar
Accuracy, (3), ± % FS ≤ 0.25 ≤ 0.1 ≤ 0.1
Thermal error, (4)
(± % FS/°C)
Zero point: 0 ... 70°C ≤ 0.06 ≤ 0.03 ≤ 0.015
Zero point: -25 ... 85°C ≤ 0.08 ≤ 0.04 ≤ 0.02
Span: 0 ... 70°C ≤ 0.015 ≤ 0.015 ≤ 0.015
Span: -25 ... 85°C ≤ 0.02 ≤ 0.02 ≤ 0.02
Total Error, (5), (6), (7)
(± % FS ; typ. / max.)
-10 ... 50°C ≤ 0.15 / 0.3
≤ 0.15 / 0.3 ≤ 0.15 / 0.3
(≤ 200 mbar: 0.3 / 0.6)
-25 ... 85°C ≤ 0.65 / 0.7
≤ 0.65 / 0.7 ≤ 0.55 / 0.7
(≤ 200 mbar: 0.65 / 0.8)
Response time, (typ.) 16 ms 16 ms 16 ms
Long term stability
< 1 mbar / < 2 mbar < 1 mbar / < 2 mbar < 0.1% FS / < 0.2% FS
(typ./max. per year)
Pressure range 0 ... > 25 to 0 ... 600, (2) 0 ... > 600 to 0 ... 1000 0.8 ... 1.2, (1)
Overpressure (Proof) 3 x FS
≤ 850 / ≤ 1500 bar 3 x FS
(≤ 850 / ≤ 1500 bar)
Burst pressure > 850 / > 1500 bar > 850 / > 1500 bar > 200 bar
Accuracy, (3), ± % FS ≤ 0.1 ≤ 0.25 ≤ 0.25
Thermal error, (4)
(± % FS/°C)
Zero point: 0 ... 70°C ≤ 0.015 ≤ 0.015 ≤ 0.06
Zero point: -25 ... 85°C ≤ 0.02 ≤ 0.02 ≤ 0.08
Span: 0 ... 70°C ≤ 0.015 ≤ 0.015 ≤ 0.015
Span: -25 ... 85°C ≤ 0.02 ≤ 0.02 ≤ 0.02
Total Error, (5), (6), (7)
(± % FS ; typ. / max.)
-10 ... 50°C ≤ 0.15 / 0.3 n.a. ≤ 0.15 / 0.3
-25 ... 85°C ≤ 0.55 / 0.7 n.a. ≤ 0.65 / 0.7
Response time, (typ.) 16 ms 16 ms 16 ms
Long term stability
< 0.1% FS / < 0.2% FS < 0.1% FS / < 0.2% FS < 1 mbar / < 2 mbar
(typ./max. per year)

(1) Typical barometric pressure range, max. offset: 900 mbar, min. span: 400 mbar
(2) Overpressure (proof) and burst pressure 1500 bar (stainless steel) optional
(3) Zero based accuracy according to EN-61298, incl. hysteresis and repeatability at ambient temperature
(4) Standard compensation
(5) Total error including accuracy and temperature influences at maximum signal span (16 mA)
(6) With option „Active compensation“ only (≥ 100 mbar, ≤ 100 bar)
(7) Does not apply to titanium solution ≤ 1 bar

www.stssensors.com 2
TEMPERATURE RANGE
Operating temperature -25 ... 85°C
Process temperature
Standard: -25 ... 100°C
Optional (with cooling fins): -25 ... 150°C
Storage temperature -25 ... 85°C

ELECTRICAL SPECIFICATIONS
Output signal 4 ... 20 mA
Resolution 0.025 %FS
Output adjustable
4 mA -5 %FS ... 105 %FS
20 mA -5 %FS ... 105 %FS
Span 25 %FS ... 110 %FS
Low pass filter 0.1 / 1 / 10 / 30 Hz
(standard: 30 Hz)
Power supply 9 ... 30 VDC
Supply influence < 0.1 %FS
Circuit diagram
P +Vin

Pout
I A
EP

Load resistance [Ohm]


R L<
UB[V] - 9V
0.02A
1000

500
RL
0
0 10 20 30 [V]
UB

Load influence < 0.1 %FS


Reverse polarity protection Yes

CERTIFICATES / APPROVALS
Certificates, (1)
ATEX SEV 08 ATEX 0142
IECEx IECEX SEV 19.0024X
ABS 09-HG436727/1-PDA
DNV TAA00002FN
Gas, (2) Zone 0 II 1G Ex ia IIC T3 ... T6 Ga
Gas, (3) Zone 1+2 II 2G Ex ia IIB T3 ... T6 Gb
Dust II 1D Ex ia IIIC T200 125°C Da
Maximum values of the
30 V / 140 mA / 0.9 W
intrinsically safe circuit
Temperature class, (4) T6 T4 T3
Ambient temperature (Ta) -25 ... 55 °C -25 ... 85 °C -25 ... 85 °C
Process temperature -25 ... 55 °C -25 ... 100 °C -25 ... 150 °C
(1) For detailed Ex specifications see certificate and operating and safety instructions
(2) Max. permitted cable length: ≤ 150 m
(3) Max. permitted cable length: ≤ 450 m
(4) Without any information about temperature class the transmitter will be delivered for T4

www.stssensors.com 3
QUALIFICATIONS
Description Level
EN 60068-2-6 Vibration 4G (4 ... 100 Hz)
EN 60068-2-27 Shock 100 G (impulse duration 6 ms)
EN 61326-2-3 EMC
EN 61000-6-2 EMC
EN 61000-6-3 EMC

PHYSICAL SPECIFICATIONS
Standard: Silicone Oil
Oil filling
Optional: AS100 / Anderol Food / PAO 4
Standard: Stainless steel (316L / 1.4435)
Transducer
Optional: Titanium (Gr. 2) or Hastelloy C-276
Standard: Stainless steel (316L / 1.4435)
Housing
Optional: Titanium (Gr. 2) or Hastelloy C-276
Weight typ. 200 gram, depending on the configuration

Accessories
CABLE SOCKET CONNECTOR
Article number Description
HART001 Cable socket connector DIN43650 (EN 175301-803A)
HART002 Cable socket connector Binder 723, 5 pins
HART012 Cable socket connector MIL C26482, 10-6
HART018 Cable socket connector M12x1, 5 pins

INTERFACE / SOFTWARE
Article number Description
102442 PTM/Ex - Interface
101224 PC Software

MANUALS
Article number Description
DEB003 Configuration software 10.00.0079
DEB005 User manual sensor 10.00.0089
DMM023 Operating and safety instructions 10.88.0271

www.stssensors.com 4
Ordering information
Type x xxxx xxxx xx xxx
PTM/Ex 47
Pressure type
Gauge 1
Absolute 2
Sealed gauge 3
Pressure measuring range
Any measuring ranges between 0 … 100 mbar and
XX
0 … 1000 bar available
Barometric pressure ranges available XX

Process connection
G 1/2 M, bore 14 mm (Fig. 1) 17
G 1/4 F (Fig. 2) 00
G 1/4 M (Fig. 3) 11
G 1/4 M, manometer EN 837 (Fig. 4) 12
G 1/2 M (Fig. 5) 13
G 1/2 M, manometer EN 837 (Fig. 6) 16
1/4 NPT M (Fig. 7) 10
1/2 NPT M (Fig. 8) 19
G 1/2 M, frontal diaphragm (Fig. 9), (1) 14
G 1/2 M, frontal diaphragm Hastelloy C-276 (Fig. 9), (1) 37
G 1/2 M, with flush diaphragm membrane (Fig. 10), (1) 15
G 1/4, with flush diaphragm (Fig. 11), (1) 21
Other pressure connections on request 99
Electrical connection
DIN 43650 (EN 175301-803A), demountable, IP 65,
01
(Fig. 12), (2), (3)
Binder 723, 5 pins, IP 67 (Fig. 13), (2) 03
MIL C26482, 10-6, 316L, IP 67 (Fig. 14), (2) 80
M12x1, 4 pins, (Fig. 15), (2) 07
PUR cable, blue, IP 67, (Fig. 16), (4), (6) 17
FEP cable, blue, IP 67, (Fig. 16), (4) 22
PUR cable, blue, IP 68, (Fig. 17), (4), (6) 36
Other electrical connections on request 99
Output signal
4 ... 20 mA 05
4 ... 20 mA with overvoltage protection 08
Accuracy
≤ ± 0.25 % FS (< 500 mbar / > 600 bar) 1
≤ ± 0.1% FS (≥ 500 mbar ... 600 bar) 2

www.stssensors.com 5
Temperature range
T6 (Ta: -25 ... 55 °C) 0 ... 70 °C compensated
0
(without cooling fins)
T4 (Ta: -25 ... 85 °C) -25 ... 85 °C compensated
1
(without cooling fins)
T3 (Ta: -25 ... 85 °C) -25 ... 85 °C compensated
2
(with cooling fins)
Options
Throttle, (7) A
Special oil filling: Anderol Food (for food applications) G
Special oil filling: PAO4 (silicone free) Q
Pressure connection elastomerfree N
Pressure connection welded V
Active compensated (≥ 100 mbar ≤ 100 bar) E
Titanium, (9) K
Seals: FKM (standard) U
Seals: EPDM S
Seals: Kalrez, (5) T
Seals: NBR, (8) H
(1) Process connection available ≤ 600 bar
(2) Cable socket connector not included
(3) IP67 if the cable socket connector HART001 is installed correctly
(4) Please specify the required cable length and medium
(5) Profile seal not included
(6) For operating temperature > 50°C, PE or FEP cable must be used
(7) Only with pressure connection Fig. 3, Fig. 5, Fig. 6, Fig. 7 and Fig. 8
(8) Suitable for drinking water
(9) Titanium available for Pn ≤ 400 bar (burst pressure max. 550 bar), not all versions are available in titanium

www.stssensors.com 6
Process connections
PN ≥ 100 mbar ... 25 bar (1)
Fig. 1 - G 1/2 M, bore 14 mm Fig. 2 - G 1/4 F Fig. 3 - G 1/4 M Fig. 4 - G 1/4 M, Manometer EN837

Fig. 5 - G 1/2 M Fig. 6 - G 1/2 M, Manometer EN837 Fig. 7 - 1/4 NPT M Fig. 8 - 1/2 NPT M

PN > 25 bar ... 1000 bar (1) (2)


Fig. 2 - G 1/4 F Fig. 3 - G 1/4 M Fig. 4 - G 1/4 M, Manometer EN837

Fig. 5 - G 1/2 M Fig. 6 - G 1/2 M, Manometer EN837 Fig. 7 - 1/4 NPT M Fig. 8 - 1/2 NPT M

PN ≥ 100 mbar ... 600 bar PN ≥ 100 mbar ... 1000 bar (3) PN ≥ 10 bar ... 600 bar
Fig. 9 - G 1/2 M, frontal diaphragm Fig. 10 - G 1/2 M, flush diaphragm Fig. 11 - G 1/4 M, flush diaphragm

(1) Dimensions for welded or elastomerfree versions may be different


(2) Not all process connections available for pressure ranges > 600 bar
(3) Dimensions for pressure ranges > 600 bar differ

www.stssensors.com 7
Dimensions
Version for medium temperature up to 100°C Version for medium temperature >100°C up to max. 150°C

L = 94 mm for connector DIN 43650 (EN 175301-803A) L = 121 mm for connector DIN 43650 (EN 175301-803A)

Electrical connections
Fig. 12 - DIN43650 (EN 175301-803A) Fig. 13 - Binder 723, 5 pins
View to cable View to cable
socket connector socket connector

Pin 2-wire
Pin 2-wire 1 Pout
1 +Vin 2
2 Pout 3 +Vin
3 4
E EP 5 EP

Fig. 14 - MIL C26482, 10-6, 316L Fig. 15 - M12 x 1, 4 pins (Lumberg RSF4)
Connector for Connector for View to cable View to cable
gauge version absolute/sealed socket connector socket connector
gauge version

Pin 2-wire
A +Vin
B Pin 2-wire
C Pout 1 EP
D 2
E EP 3 Pout
F 4 +Vin

Fig. 16 - Cable connection IP67 Fig. 17 - Cable connection IP68

Colour 2-wire
white +Vin
yellow Pout
grey EP

Specifications may change without notice


© 2022 - STS Sensor Technik Sirnach AG, Rütihofstrasse 8, CH - 8370 Sirnach, Switzerland, www.stssensors.com