0% found this document useful (0 votes)
27 views

AVA Series 200 - English

The Series 200 technical datasheet outlines two actuator series: Basic and Smart, featuring a torque output of 200Nm suitable for large valves and a multi-voltage range for flexibility. The Smart series includes advanced functionalities like a larger OLED screen, SmartMenu for parameter adjustments, and self-diagnostic tools. Both series are designed for safe area applications and are available with various wiring and housing options, along with a QR code for easy access to support documents.

Uploaded by

epemba1978
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
27 views

AVA Series 200 - English

The Series 200 technical datasheet outlines two actuator series: Basic and Smart, featuring a torque output of 200Nm suitable for large valves and a multi-voltage range for flexibility. The Smart series includes advanced functionalities like a larger OLED screen, SmartMenu for parameter adjustments, and self-diagnostic tools. Both series are designed for safe area applications and are available with various wiring and housing options, along with a QR code for easy access to support documents.

Uploaded by

epemba1978
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

TECHNICAL DATASHEET

SERIES 200

BASIC SERIES
• 200Nm torque output makes the Series 200 perfect for large size ball valves
and butterfly valves.
• Introduces ‘Wiring Box’ and removes pre wired cable.
• Multi Voltage 24VAC/DC or 95-265VAC voltage range, reducing stock
required to be held to cover possible on site voltages.
• Declutchable manual override selector button located in top cover.
• Available with internal super capacitor fitted for Failsafe functionality.
• 2 x M20 Conduit Entry

Version 001: 3/10/22 subject to change without notice

Technical Specifications

Rated Torque Nm (in.lbs): 240Nm Break (2124) / Run 200Nm (1170) Enclosure: PC+ PET Plastic Housing ** IP67/Nema 4X

ISO 5211: F07/10 x 22mm Output Drive LED Status Light: Yes, RGB Open, Close, Alarm.

Voltage Range: 24VAC/DC, 95-265VAC Run Time no load: 25 seconds

Connecting Cable: 2 x M20 Conduit Wiring Box Weight: 6Kg - only available in plastic currently

Working Angle Range: 0-270 degrees. Set via internal cams. Temperature Range: -20 > +80C ***

Duty Cycle: 75% rated Shock Resistance: <300m/S2

Sound Power Level: Max50dB(A) Vibration Rating: 10 to 55Hz, 1.5mm double amplitude

Position Indicator: Mechanical Dome Window. As above Installation : Vertical/Horizontal - not underslung

Withstand Voltage: 500VAC for 1 minute Maintenance: Maintenance Free - do not remove cover

Insulation Resistance: 100MΩ/ 500VDC Approvals: TUV CE & EMC Certified, REACH, RoHS***

Explosion Proof: No, not to be used in a hazardous location. Can only be used in safe area applications.

* Series 200 doesn't have pre wired cable. Customer to supply and fit own cable as required. However, we can supply prewired, speak to your sales representative.

** PC+PET plastic cover as standard. Aluminium cover to be made available in the future.

*** Note that we can extend the lower temperature range through special lubricant and grease and upgraded heater system. Speak to your sales representative.

*** AVA has began the process to have all of our electric actuators approved for UL and CSA

Main Ordering Codes for Basic Series: *indicates standard options for stock product Example : B2045-PHB-22

Series > Function > Voltage + Housing > Heater > Wiring + Output Drive>

B Basic 200 On Off 5 95-265VAC P PC+PET* H Included* A 3 wire SPST 22 22mm*

204 Failsafe 6 24VAC/DC 0 Without B 3 wire SPDT*

New feature, we are adding a QR label to all of our products that will enable users of our
product to have quicker and more direct access to support documents via our new purpose
built QR website. Simply scan the QR code using your Smart phone camera and you will be
taken directly to the specific actuator you have on site and will have access to Technical
Datasheets, Firmware guides and product support videos.

English version. Available in Spanish

Join the orange and grey revolution


TECHNICAL DATASHEET
SERIES 200

SMART SERIES
• Larger OLED screen to display more information than ever before.

• New SmartMenu provides onboard Firmware and enables user to change certain
parameters in the actuator including speed, angle, accuracy.

• Self diagnostic tool, actuator will check its vital components to ensure eve-
rything is in good working order. Motor RPM, ambient temperature, humidity.

• Local Control as standard allows the user to operate the actuator open > close via the
touch buttons.

• Increased functionality including Modulating, Failsafe Modulating, Modulating , Modbus


RS485/RTU.

Version 001: 3/10/22 subject to change without notice

Technical Specifications:

Rated Torque Nm (in.lbs): 240Nm Break (2124) / Run 200Nm (1170) Alarm Relay: Yes, option for fault alarm output

ISO 5211: F07/10 x 22mm Output Drive LED Status Light: Yes, RGB Open, Close, Alarm.

Voltage Range: 24VAC/DC, 95-265VAC, Run Time no load: 25 seconds

Connecting Cable: 2 x M20 Conduit Wiring Box 3 Position Function: Yes, setup via SmartMenu firmware

Working Angle Range: 0-270 degrees. Set via digital encoder. Working angle can be digitally set via SmartMenu firmware.

Duty Cycle: 75% rated - 100% rated for Modulating Brushless Motor: Yes, DC brushless motor

Sound Power Level: Max50dB(A) Modulating Control: Pre set at factory where applicable.

Position Indicator: Mechanical connected to digital encoder sensor for accurate position sensing.

Local Control: Yes via SmartMenu using touch buttons Reverse Acting: Yes, set via SmartMenu

Speed Control: PWM or PULSE speed control via SmartMenu Fail to 3rd Position: Yes, set via SmartMenu

Explosion Proof: No, not to be used in a hazardous location. Can only be used in safe area applications.

** See previous page for details on options available on pre wired cable lengths, temperature rating, cover and upcoming approvals.

Main Ordering Codes for Smart Series: *indicates standard options for stock product Example : S20010-6PHE-22

Series + Function > Voltage + Housing + Heater + Wiring > Output Drive>

S200 Smart 10 On Off 5 95-265VAC P PC+PET* H Included* E 3 wire SPDT* 22 22mm*

14 Failsafe 6 24VAC/DC 0 Without P 4-20mA

25 Modulating U 0-10V Alarm Relay>

26 Modulating Failsafe V 2-10V A Alarm

31 Modbus On Off W RS485 Modbus

34 Modbus Failsafe
Failsafe via internal super capacitor if you have selected
35 Modbus Modulating Failsafe version. Capacitor is charged whilst power ap-
plied. When power is removed capacitor will close/open
actuator.

Technical Support: +44(0)1386 556847 [email protected]


TECHNICAL DATASHEET
SERIES 200

POWER & WIRING


All you need to know for sizing the correct power supply for the actuators you are
installing including the power requirements when the actuator is running and what
we would call Peak or maximum power requirements.

Version 001: 3/10/22 subject to change without notice

Power Ratings for most common series: Note that internal heater power is 2W.

Code Voltage Power Time Fuse Peak Code Voltage Power Time Fuse Peak

B2005-PHB-11 95-265VAC 120W 25s 10A 7.5A S20025-6PHP/U-11 24VAC/DC 120W 25s 10A 7.5A

B2006-PHB-11 24VAC/DC 120W 25s 10A 7.5A S20026-5PHP/U-11 95-265VAC 150W 25s 10A 7.5A

B2045-PHB-11 95-265VAC 150W 25s 10A 7.5A S20026-6PHP/U-11 24VAC/DC 150W 25s 10A 7.5A

B2046-PHB-11 24VAC/DC 150W 25s 10A 7.5A S20031-5PHW-11 95-265VAC 120W 25s 10A 7.5A

S20010-5PHE-11 95-265VAC 120W 25s 10A 7.5A S20031-6PHW-11 24VAC/DC 120W 25s 10A 7.5A

S20010-6PHE-11 24VAC/DC 120W 25s 10A 7.5A S20034-5PHW-11 95-265VAC 150W 25s 10A 7.5A

S20014-5PHE-11 95-265VAC 150W 25s 10A 7.5A S20034-6PHW-11 24VAC/DC 150W 25s 10A 7.5A

S20014-6PHE-11 24VAC/DC 150W 25s 10A 7.5A S20035-5PHW-11 95-265VAC 120W 25s 10A 7.5A

S20025-5PHP/U-11 95-265VAC 120W 25s 10A 7.5A S20035-6PHW-11 24VAC/DC 120W 25s 10A 7.5A

Standard On Off, Failsafe and Hi-Speed Open/Close Wir- Standard Modulating including Failsafe and Hi-Speed
ing: Additional wiring options available online. Wiring: Additional wiring options available online.

1.BLUE BLUE
Neutral /- Neutral /-
Power
Live Close /+ 2.RED Power Live /+ RED
FUSE
Switch
FUSE
Live Open /+ 3.BLACK
*Do not apply power to
Ground 3.EARTH Control & Feedback. This
will cause major damage
to actuator.

Not used 4.ORANGE


Alarm if selected 4.BLACK
Control &
Ground, Y/G 5.EARTH Feedback
5.GREEN Feedback

Not used 6.PURPLE


V In 6.PURPLE Modulating 50-110Nm Series have
10 core terminal
connection within the wiring box.
Feedback Open 7. GRAY This allows for the user to wire
V Out 7.ORANGE
‘either’ Volts or mA’s for the input
control.

Black and Green terminals are only


Feedback Close 8. BROWN
mA In
used if the ALARM relay is ordered
and connected.
8. GRAY

Feedback Common 9.WHITE


mA Out 9. BROWN
Remove wiring box via 4 x screws. This will expose the wiring
terminal. Simply match the colours and codes you see against
the above. Then re fit the wiring box and ensure seal is in place. 10 WHITE

Important, we are changing our wiring box in Q4 2022 to a separate the power and feed-
back as shown to the left hand side compared to the current style as shown in the image
of the actuator above. This will help prevent users accidentally applying power to the
feedback terminals. See IOMs document for more information.

Our complete range covers 10-400Nm


TECHNICAL DATASHEET
SERIES 200

MATERIALS & DIMENSIONS


Below are the materials of construction, including any options available for this spe-
cific series. Dimensional drawing can also be found below detailing key dimension details
including ISO 5211 mounting details.

Version 001: 3/10/22 subject to change without notice

Manual Override Key is steel

Cover and base is PC+PET


Output drive is carbon steel
plated finish.
Screen has UV rated cover. Labels
are PVC. Touch buttons on Smart
series are rubber
ISO 5211 plate is coated
steel
Manual override shaft is plated
steel, seal is NBR rubber.

Screws are SS304


Transparent AS plastic dome
indicator.

Plastic Declutchable manual over-


ride push button.
Cable entry is Nylon

* Note that the Basic and Smart series are the same physical size.

We are able to supply our actuators with a prewired cable with IP67/68
weatherproof rated plug and play connector. We can supply both male and female
connectors with a pre determined cable length required. We are able to terminate
the cable for your PLC as required, loose for you to terminate or with a panel mount
connector for example. Options include screw terminal and welded (soldered) con-
nection.

To access our website for additional support documents, con-


tact information and latest news, simply scan the QR code. You
can find our list of official distributors at our website.

Technical Support: +44(0)1386 556847 [email protected]