The document provides operational instructions for an ultra low temperature freezer, detailing its features, precautions, and maintenance guidelines. It emphasizes the importance of following safety protocols, proper installation, and usage to ensure optimal performance and longevity of the unit. Additionally, it outlines the warranty and after-sale service commitments for consumers.

Uploaded by

Carl Lee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
39 views16 pages

BDF-86V936 User manual

The document provides operational instructions for an ultra low temperature freezer, detailing its features, precautions, and maintenance guidelines. It emphasizes the importance of following safety protocols, proper installation, and usage to ensure optimal performance and longevity of the unit. Additionally, it outlines the warranty and after-sale service commitments for consumers.

Uploaded by

Carl Lee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

Ultra low Temperature Freezer Series

Operation Instruction

·Please read the operation instruction before installing and using this product

andkeep it safe for reference.

·Please observe the operating instructions and precautions of the directions.

·If fault occurs, do not repair by yourself or send it to a maintenance

department which is unauthorized by our company.

·Please contact the local maintenance department authorized by our company.

0
I Main performance and characteristics of the product
 Thermal insulating door and secondary seal door are adopted for use convenience. The loss

of refrigeration capacity is reduced and the energy consumption is saved.

 Air-cooled condenser is adopted which is provided with good heat dissipation and fast

refrigerating speed.

 Stainless steel inner and tube-in-sheet evaporator are adopted. Things can be put in or taken

out easily. The refrigeration effect is good and the freezer can be cleaned easily.

 Import microcomputer temperature controller is adopted for accurate temperature control.

The temperature inside the freezer is displayed digitally. With elegant appearance, the

freezer can be used conveniently. Users can regulate and check the inside temperature and

the working state without opening the door.

 The microcomputer control is more accurate and safer.

 The system is equipped with a safety protection device for ensuring the safe and reliable

operation of the system.

 The refrigerating system all adopts imported parts which provide good reliability and long

service life to the system

II Precautions
The sign of “ ” means the place is dangerous to human bodies, or the use pattern is

harmful to products, or alarm users should pay special attention to this.

:It is strictly prohibited to unpack the outer packing case for transportation.

The ultralow temperature freezer should be used under the environmental temperature of

10℃~32℃. It is suggested to use it under the environment with air conditioning.


1
:The slant angle of the body of the ultralow temperature freezer should not be larger

than 45°in transportation to avoid faults of the compressor or the system.

:After unpacked, the freezer should be placed on flat and firm ground near to the power

socket.

:Do not put it near the heat source and avoid the sunshin

:The ultralow temperature freezer should be stored in a dry and drafty

room without corrosive gas surrounding.

:If the ultralow temperature freezer has to be stopped for a long period, it should be

cleaned inside and outside and then covered properly with a plastic housing.

:The power supply is 187V~242V/60Hz. If the voltage is instable, please equip a

power regulator which is above 3000VA and please use it alone.

:It is necessary to provide individual one-phase three-hole socket and proper fuse for the

ultralow temperature freezer.

:The ultralow temperature freezer must be provided with reliable independent ground

wire. The ground wire cannot be connected with gas pipe, stem heating pipe and water pipe and

the zero line of single-phase source should not be taken over as well.

:If the power connect wire has to be lengthened, the sectional area of the conductor is

larger than or equals to 1.5mm. The conductor can be single-stranded or multi-stranded. It is

strictly prohibited to use multipurpose socket for connection.

:The ultralow temperature freezer cannot lean against the wall. The space of at least

30cm should be left at the machine room for normal running of the system.

:No water is allowed to be splashed on the outside body of the ultralow temperature

freezer. When scouring the ground, it is strictly prohibited to splash water into the control panel
2
and the compressor room. It is also prohibited to use the product in the rain or under the

environment with the relative humidity of larger than 85%. Otherwise, faults such as electric

leakage etc. may be caused.

:With continuous operation system, the ultralow temperature freezer should be restarted

after five minutes in case of power failure or machine halt to prevent the compressor or the

system from being damaged.

:The key of the ultralow temperature freezer should be kept out of the reach of children

to avoid accidents.

:Inflammable, explosive and volatile dangerous articles and acid and alkali etc. with

strong corrosiveness are never allowed to be put in the ultralow temperature freezer.

:The ultralow temperature freezer cannot be used under inflammable and explosive gas

environment. Be sure not to spray combustibles such as paint, coating etc. to avoid fires.

:The door should be closed tight. Otherwise, the normal operation and usage of the

system may be affected.

:The service environment pollution grade of the ultralow temperature freezer is grade 2.

III Range of application


The ultralow temperature freezer is provided to departments of medicine, health, medical

treatment, food, chemical industry, scientific research etc. for low-temperature freezing, storage,

test and subzero treatment.

IV Preparation for use


·After unpacking, remove all outer packing material.

3
·Checking standard accessories and data: check and compare the inside accessories and
data with the packing list【please see related pages of the directions】.
·Please place the ultralow temperature freezer at proper location【please refer to relevant
terms in Precautions】.

·It would be best to clean the freezer before use【please refer to relevant terms in
Maintenance】.

V Structure diagram

VI Start and test machine


·Plug in the socket and switch on the power switch (located at the right side of the
temperature controller on the front part of the body). Then the power supply indicator light is

4
on. In order to ensure the normal running of the cryogenic freezer, be sure to use the three-hole
socket which is above 16A.
·The system will automatically start the compressor, and the refrigeration indicator light is

on. The system goes into refrigerating cycle state.

·After the power has been supplied for a period of time, the temperature inside the freezer

decreases obviously, which indicates the refrigerating system is working normally.

·Before storing articles, please keep the freezer running in empty state. When the freezer is

running stably (it is best to keep it running in empty state for 5 hours above) and the inside is

cooled completely, the cold store articles can be put in.

VII Model and main technical parameters

Model BDF-86V950

Type Vertical type

Total effective volume (L) 950

Storage temperature -40℃~-86℃

Rated voltage (v) 220~

Frequency (Hz) 60

Rated power(W) 1600

Power consumption (kW.h/24h) 14.5

Electric-shock protection class Class I Type B

Type of alarm Sound-light alarm

Climate type N

5
Refrigerating fluid Fluoride-free mix

Net weight of machine (kg)/ Gross weight


310/340
(kg)

Machine dimensions width×depth×height


1240×1000×2000
(mm)

Notes: technical parameters in this table are measured at the standard state. Please be

subject to the nameplate of the goods freezer without prior notice in case of variation.

VIII Functions and basic operation of controller

1. Display window: display the current temperature in the cabinet when it


works normally.
2. Display switch button: when it works normally, hold this button for 1s
to display every probe temperature and current voltage; press it again to return
to normal state. In the parameter setting menu, press it to exit the setting menu.
3. Buzzer
4. MUTE button: press this button to stop the alarm. (Only stops the sound of
the alarm. If the fault is not removed, the buzzer will a larm again)
5. Condenser alarm indicator: When there’s too much dust on the
6
condenser filter, the indicator will be lighted. Then please clean the
filter.
6. Abnormal voltage alarm indicator: When the input voltage exceeds
220V±10%, the indicator will be lighted.
7. Ambient temperature alarm indicator: When the ambient temperature
exceeds 32℃ , the indicator will be lit; when the ambient temperature exceeds
35℃ , the indicator will be lit and the buzzer sounds.
8. High-temperature alarm setting indicator: When setting the
high-temperature alarm, the indicator will be lighted.
9. Low-temperature alarm setting indicator: When setting the
low-temperature alarm, the indicator will be lighted.
10. Enter button: when setting parameters, this button works as Co nfirm
and Save.
11. Value - button (∨ ): when setting parameters, press this button to
decrease the value.
12. Value + button ( ∧ ): when setting parameters, press this button to
increase the value.
13. Mode button: when setting parameters, press this button to switch the
mode.
14. Probe calibrating and setting indicator: When calibrating the
temperature of probe, the indicator will be lighted.
15. In-cabinet temperature setting indicator: when setting the temperature
in the cabinet, the indicator will be lighted.
16. II Compressor working indicator: when the II compressor is working,
the indicator will be lighted.
17. I compressor working indicator: when the I compressor is working, the
indicator will be lighted.
18. Power failure alarm indicator: When the power supply is cut off, the
indicator will be lighted.
19. Low-temperature alarm indicator: When the temperature in the cabinet
is lower than the set value for a certain period, the indicator will be lighted.
20. High-temperature alarm indicator: When the temperature in the cabinet
is higher than the set value for a certain period, the indicator will be lighted.
21. Battery volume alarm indicator: When the battery volume is too low,
the indicator will be lighted.
22. Sensor indicator: When the probe is in short circuit or open circui t, the
indicator will be lighted.
23. Open door alarm indicator: When the door opens for a certain period,
the indicator will be lighted.

IX Schematic circuit diagram


7
ECS=thermostat FM=condensing CM=compressor

SR=starting relay DS=door switch SE=sensor

X Storage essentials
·Before storing articles, please keep the freezer running in empty state. When the freezer is

running stably (it is best to keep it running in empty state for 9 hours above) and the inside is
8
cooled completely, the cold store articles can be put in.

·Articles or other products put in the freezer in one time shouldn’t be too much. Proper

clearance should be left to help the circulation of the inside cold air.

The refrigerating system of the ultralow temperature freezer is a device used for

maintaining low temperature rather than a quick freezing device. If you want to store high

capacity (high water-bearing material), precool them in other quick-freezing plant and then

store them in the freezer to avoid long-time running without stop of the refrigerating system.

·When the initial storage capacity is large, a method of gradually lowering the temperature

set should be adopted. The temperature is lowered by 10℃ in every step and then maintained

for 1-2 hours until the storage temperature is reached.

·When storing plastic bag products, please note that do not get them close to metal edges

to avoid scratch of plastic bag.

XI Maintenance
·Body cleaning: please use non-corrosive neutral cleaning agent to clean the inside and

outside surfaces of the ultralow temperature freezer and then use dry cloth to wipe it up.

Notes: it is strictly prohibited to use water to directly wash the inside and outside

surfaces of the freezer so as not to affect the insulating property of electrical equipment. Boiling

water, cleaner, acid, alkali, gasoline, alcohol, benzene, corrosive cleaning agent and scrub-bush

are forbidden in cleaning.

·Clean dusts on the condenser frequently by banister brush or vacuum cleaner to maintain

good condensing effect.

·Regularly wipe a little talcum powder on the door seal to extend the service life of the

sealing strip.
9
·If the ultralow temperature freezer has been running for a long time, frost may be easily

accumulated on the door seal, the opening part of the freezer and the side wall inside the freezer.

If the frost layer is too thick, the sealing property and the refrigerating property may be affected.

Therefore, please defrost regularly and wipe it clean with dry cloth.

·Please use non-corrosive neutral cleaning agent to clean the inside and outside surfaces of

the freezer and then use dry cloth to wipe it up.

·Machine halt: when stop using the freezer, unplug the power plug, clean it according to the

above method, cover it with a plastic bag after natural drying and put it on a ventilated and

clean place.

XII Non-fault phenomenon


·Sound of running water can be heard in the ultralow temperature freezer: this is the sound

of refrigerating fluid running in the pipeline.

·Compressor is hot: when the compressor is running, the surface temperature can reach to

70℃~90℃.

·You may feel a little hot on the two sides of the body (close to the door body) when the

freezer is running. That is because the leakproof tube equipped in the freezer.

·There is condensation on the door seal: in rainy and moist season or under the

environment with higher relative humidity, there may be condensation on the outer surface of

the freezer and the door seal. Then rub dry.

XIII General fault analysis and removal


1. The ultralow temperature freezer does not work and there is no display on the

10
controller

·If the power plug wire is properly connected and the main power supply is plugged in

·If the power switch is turned on

·If the power socket is in good condition

·If the fuse has been burned out

·If the controller is broken or line is damaged: it is necessary to contact the nearby

maintenance department for overhaul

2. The compressor is running without stop, but the temperature inside the freezer

does not decrease

·The door is opened too often for too long: try to reduce the door-opening time

·The storage capacity is too much: take some out or distribute evenly to keep the air inside

the freezer flow

·The condenser is dirty and the heat dissipation is not good: clean the condenser (operate

according to relevant terms in Maintenance)

·Refrigerant leeks or pipeline is blocked: it is necessary to contact the nearby maintenance

department for overhaul

·The condensate fan in the machine room is broken: it is necessary to contact the nearby

maintenance department for overhaul

3.Large noise

·If the outer packing has been all removed

·If the freezer is placed smoothly

·If the back part of the freezer body contacts with the wall: please operate according to

relevant items in Precautions.


11
·The compressor is in abnormal operation only with drone: if the power voltage is within

the defined limits, and please operate according to relevant terms in Precautions.

·The fan in the machine room makes a lot of noise: the fan is broken or contacts with

something. It is necessary to contact nearby maintenance department for overhaul

Notes: if the ultralow temperature freezer still cannot work normally after being inspected

and handled according to the above methods, please contact the maintenance department of our

company in time.

XIV After-sale service and commitment


In order to provide satisfactory after-sale service to consumers using our company’s

products and maintain the legal rights of the consumers, our company will strictly follow the

“Law of PRC on Protection of Consumers’ Rights and Interests” and relevant provisions in

“Regulations on Repair, Change and Return Responsibilities of Partial Goods” formulated

by the State Bureau of Technical Supervision and the Bureau of Finance and provide you with

following services basing on the warranty card and the invoice:

The whole machine is guaranteed for twelve months since the purchase date (subject to the

invoice).

The whole machine can enjoy life service. And we will charge for repairing in case of one

of the following conditions:

·Products with expired guarantee period and products without warranty card and invoice

·Damages due to user’s improper transportation and storage or damages caused by the fact

that the user does not operate according to the requirements in the instruction book

12
·Damages caused by the supply voltage exceeding the prescribed limit(187V~242V)or

products repaired by a maintenance station which is not authorized by our company

·Inconformity or alteration of the product warranty card and the purchase invoice

·Damages caused by irresistibility

·Price-cut parts of products which are sold by retailers at a cut price

Packing Accessories

Model Instruction Book Lock Keys

BDF-86V950 1 1 2

To distributor:
The warranty card should be full filled by distributor, only effective with seal and filed by
sales department.

Product name:
Product model:
Final user (or unit) name: Guarantee period:
Final user (or unit) address: Phone No.:
Purchase date:
Distributing unit name: (effective with seal)
Phone No.: Address:

After filling it, please cut it off along the dash line.

13
To final user (unit):
This warranty card is an important certificate for final user (unit) to enjoy warranty
service and please keep it well.

Product name:
Product model:
Final user (or unit) name: Guarantee period:
Final user (or unit) address: Phone No.:
Purchase date:
Distributing unit name: (effective with seal)
Phone No.: Address:

Certificate of Quality

Inspector:

14
Biobase Biodustry(Shandong) CO.,LTD

Address: No. 51 South Gongye Road, Jinan, Shandong, China

Tel: 0086-531-81219801/03; Fax: 0086-531-81219804

Website: http://www.biobase.cc

Made in China

15

You might also like