1 LIGHTING OUTLET 4 400 230 1.77 15 2P 50 2 - 2.00 MM² THHN WIRE 20 MM² ø PVC PIPE.
2 CONVENIENCE OUTLET 4 720 230 3.13 20 2P 50 2 - 3.5 MM² THHN WIRE 20 MM² ø PVC PIPE.
TOTAL COMPUTED LOAD 1120 230 4.9 20 2P 50 2 - 5.5.0 MM² & 1 - 3.5MM² THHN WIRE 25 MM² ø PVC PIPE.
1
a a
PROTECTION COMPUTATIONS:
ITFL = total ampere load x 80% (demand factor)
ITFL = 4.9 x 80%
ITFL = 3.92 A
SIZE OF MAIN WIRE & CONDUIT:
USE: 2- 5.5 mm² THHN & 1- 3.5 mm² THHN (GRND) in 25 mm dia. PVC pipe, 20AT/50AF, 2pole
2. ALL WIRING SHALL BE INSTALLED IN STANDARD CONDUIT PIPES RUN EMBEDDED LIGHTNING OUTLET
INSIDE THE CONCRETE AND HALLOW STRUCTURES, SLABS, COLUMNS AND/ OR
RUN CONCEALED BETWEEN DOUBLE WALL WOODED PARTITIONS AND INSIDE THE
CEILING SPACES. WATT HOUR-METER
3. UNLESS OTHERWISE INDICATED ON THE PLANS, THE MINIMUM SIZE OF WIRE AND
CONVENIENCE OUTLET
CONDUIT TO BE USED SHALL BE 2.00mm², AND 20 mm Ø PVC RESPECTIVELY.
4. ALL LIGHTNING AND CONVENIENCE OUTLET CIRCUIT HOMERUNS SHALL BE MPB BREAKER
WIRED WITH NOT LESS THAN 3.5mm² IN SIZE. ALL 15 AND 20 AMPERE CIRCUIT MAIN PANEL BOARD - MPB
HOMERUNS TO PANELBOARD MORE THAN 30 METERS IN LENGTH SHALL BE
WIRED WITH NOT LESS 5.5mm² IN SIZE, UNLESS OTHERWISE INDICATED ON THE
PLANS.
GROUND
5. ALL NON- CURRENT CARRYING METAL PARTS OF THE EQUIPMENT IN THE
SYSTEM SHALL BE PROPERLY GROUNDED IN ACCORDANCE WITH THE
1 CIRCUIT HOMERUN
PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE.
6. ALL MATERIALS SHALL BE NEW AND OF THE APPROVED TYPE FOR THE LOCATION
AND PURPOSE.
ELECTRICAL SYMBOLS USE 2 - 5.5 mm² THHN Wire in 25mm dia. PVC pipe
CKT 1 CKT 2
8. ALL WALL OUTLETS SHALL BE INSTALLED AT THE FOLLOWING HEIGHTS ABOVE 15 A 20 A
10. ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT AND IMMEDIATE
SUPERVISION OF DULY LICENSED ELECTRICAL ENGINEER OR REGISTERED
SINGLE LINE DIAGRAM
MASTER ELECTRICIAN.
PREPARED BY: PROJECT NAME: CONCURRED BY: SHEET CONTENTS: SHEET NO.
PLACE ISSUED: TUGUEGARAO CITY LOCATION: PUROK 3, BRGY. NANGALISAN, SOLANA, CAGAYAN OWNER