RJ-10G-DW-E: Features

The RJ-10G-DW-E is a ruggedized fiber optic transceiver that operates at a data rate of 10.3125Gbps, designed for harsh environments with a wide temperature range of -40°C to +85°C. It features a duplex transceiver module with EML DWDM transmitter and APD wideband receiver, compliant with IEC-60825-1 Class 1 laser safety standards. The module includes digital diagnostics and is available with conformal coating options for enhanced durability.

Uploaded by

alatsis.n
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views11 pages

RJ-10G-DW-E: Features

The RJ-10G-DW-E is a ruggedized fiber optic transceiver that operates at a data rate of 10.3125Gbps, designed for harsh environments with a wide temperature range of -40°C to +85°C. It features a duplex transceiver module with EML DWDM transmitter and APD wideband receiver, compliant with IEC-60825-1 Class 1 laser safety standards. The module includes digital diagnostics and is available with conformal coating options for enhanced durability.

Uploaded by

alatsis.n
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

RJ-10G-DW-E

10.3125Gbps
Rugged RJ Size Fiber Optic Transceiver
Features:

• Duplex transceiver module.


• Compliant operation at 10.3125Gbps.
• EML DWDM transmitter and APD wideband receiver.
• Compliant to IEC-60825-1, Class 1 laser eye safe.
• Solder-down 1x12 electrical interface.
• +3.3V and +2.5V power supply.
• SFF-8472 compliant control and diagnostics monitor interface.
• –40°C to +85°C case temperature operating range.
• –55°C to +105°C storage temperature range.
• Conformal coating options for harsh environment use.
• Option for RoHS 6(6) compliant and lead free per Directive
2002/95/EC.

The RJ-10G-DW-E is a unique


ruggedized fiber optic
transceiver designed to
provide peak performance in
hazardous enfironments.

Absolute Maximum Ratings


Parameter Symbol Min. Max. Unit Notes
3.3V Supply Voltage VCC_3V3 –0.3 4.0 V
2.5V Supply Voltage VCC_2V5 –0.5 3.0 V
Storage Temperature Tsto –55 105 °C
Case Operating Temperature TOP –40 85 °C
Relative Humidity RH - 85 % Based on conformal coating, (1)
Hot Bar Soldering Temperature - - 260 °C 10 seconds, leads only, (2)
Hand Lead Soldering Temperature - - 260 °C 10 seconds, leads only, (2)
Conformal Coating - 0.8 1.2 mil (3)
Notes:
1) RJ transceivers may be water washed. The process must be followed by an 80° bake for one hour to ensure the drying of any water inside the
shell.
2) The components should not undergo Reflow Soldering under any circumstances.
3) See ruggedization notes on page 10.

General Specifications
Parameter Symbol Min. Typ. Max. Unit Notes
Data Rate, Ethernet BREE 6 - 10.3125 Gbps 64b/66b
3.3V Supply Voltage VCC_3V3 3.14 3.3 3.47 V
2.5V Supply Voltage VCC_2V5 2.375 2.5 2.625 V

749 Miner Road, Highland Heights, OH 44143


PRELIMINARY Page 1 of 11 © 2023 | COTSWORKS, INC. 440.446.8800 | [email protected]
RJ-10G-DW-E
10.3125Gbps
Rugged RJ Size Fiber Optic Transceiver

Electrical Specifications (TOP = –40 to 85°C, VCC_3V3 = 3.14 to 3.47 Volts, VCC_2V5 = 2.375 to 2.625 Volts)
Parameter Symbol Min. Typ. Max. Unit Notes
Total Module Power Dissipation PDISS - - 2.5 W
Total Module Power Dissipation (TX Disable) PDISS_TXD - - 2.0 W
3.3V Supply Current ICC3V3 - - 500 mA
2.5V Supply Current ICC2V5 - - 380 mA
Transmitter
Differential Input Impedance RIN 80 100 120 Ω
Differential Data Input Swing VDTX 150 - 1250 mV
TX Disable Input Voltage VD 2.0 - VCC+0.3 V
TX Enable Input Voltage VEN –0.3 - 0.8 V
TX Fault Output Low VTFL –0.3 - 0.4 V
TX Disable Assert Time toff - - 100 ms
TX Enable Assert Time ton - - 2 ms
Initialization Time for Cooled Module tstartup - - 90 s
Receiver
Differential Output Impedance ROUT 80 100 120 Ω
Differential Data Output Swing VDRX 500 - - mV
Data Output Rise Time tr - - 90 ps (1)
Data Output Fall Time tf - - 90 ps (1)
Data Dependent Output Jitter DDJ - - 0.42 UI (2)
Total Contributed Jitter RX∆TJ - - 0.75 UI (3)
LOS De-Assert Voltage LOSD 0 - 0.4 V (4)
LOS Assert Voltage LOSA VCC_3V3 – 0.5 - VCC_3V3 + 0.3 V (4)
Loss of Signal Assert Time ta - 12 100 µs
Loss of Signal De-Assert Time td - 12 100 µs
Serial Bus
Data, Clock Input Low Voltage VIL –0.3 - 0.3*VCC V
Data, Clock Input High Voltage VIH 0.7*VCC - VCC+0.3 V
Data, Clock Output Low Voltage VOL - - 0.4 V
Data, Clock Output High Voltage VOH VCC–0.4 - - V
Notes:
1) K28.5.
2) 231–1.
3) 20% to 80%.
4) LOS is LVTTL. Logic 0 indicates normal operation; logic 1 indicates no signal is detected.

749 Miner Road, Highland Heights, OH 44143


PRELIMINARY Page 2 of 11 © 2023 | COTSWORKS, INC. 440.446.8800 | [email protected]
RJ-10G-DW-E
10.3125Gbps
Rugged RJ Size Fiber Optic Transceiver

Pin Configuration
PIN # Symbol Description Notes
1 TX- Transmitter Data Input, Negative CML

2 TX+ Transmitter Data Input, Positive CML

3 GND Ground 0V

4 VCC_2V5 2.5V Supply 2.5V

5 TX_DIS Transmitter Disable LVTTL

6 SCL I2C Clock I2C

7 SDA I2C Data I2C

8 LOS Receiver Loss of Signal LVTTL

9 VCC_3V3 3.3V Supply 3.3V

10 GND Ground 0V

11 RX+ Receiver Data Output, Positive CML

12 RX- Receiver Data Output, Negative CML

Digital Diagnostics Information:


The COTSWORKS RJ module utilizes signal pins for a 2-wire bus required to access digital diagnostics compliant to SFF-8472 multi-
source agreement. The transceiver pinout (including those pins required for 2-wire communication to access the digital diagnostics)
appears on the previous table.

For more information on Digital Diagnostics, visit www.cotsworks.com/support.

749 Miner Road, Highland Heights, OH 44143


PRELIMINARY Page 3 of 11 © 2023 | COTSWORKS, INC. 440.446.8800 | [email protected]
RJ-10G-DW-E
10.3125Gbps
Rugged RJ Size Fiber Optic Transceiver

Optical Characteristics (TOP = –40 to 85°C, VCC_3V3 = 3.14 to 3.47 Volts, VCC_2V5 = 2.375 to 2.625 Volts)
Parameter Symbol Min. Typ. Max. Unit Notes
Transmitter
Average Output Optical Power (SMF) POUT 0 - +2 dBm (1)
Optical Modulation Amplitude (SMF) OMA 1.70 - - dBm (1)
Optical Center Wavelength λ - λ - nm (3)
Spectral Width (RMS) (–20dB) σ - - 0.11 nm (4)
Extinction ratio ER 8.2 - - dB
Based on center
Side Mode Suppression Ratio SMSR 35 - - dB
wavelength
TX Mask Compliance - {X1, X2, X3, Y1, Y2, Y3} = {0.25, 0.40, 0.45, 0.25, 0.28, 0.75}

Receiver
Receiver Sensitivity RXSENS - - –22.8 dBm (2)
Receiver Sensitivity (OMA) RXSENS_OMA - - –21.11 dBm (2)
Receiver Saturation RXSAT –4.0 - - dBm
Optical Wavelength λC 1270 - 1577 nm
Loss of Signal De-Assert LOSD - - –26 dBm
Loss of Signal Assert LOSA –36 - - dBm
Loss of Signal Hysteresis LOSH 0.5 - 5 dB
Notes:
1) Measured at the end of a 2m SMF jumper.
2) Measured at a 10.3125Gbps with a BER=10–12.
3) See ITU Channel Ordering Options table on sheet 11.
4) Defined as ± the parameter value.

Address A0h Data Fields


A0h Address (dec) # Bytes Name Description Value (hex)
Base ID Fields
00 1 Identifier Type of transceiver 02
01 1 Ext. Identifier Extended identifier of type of transceiver 04
02 1 Connector Code for connector type 07
03 00
04 00
05 00
06 00
8 Transceiver Code for electronic or optical compatibility
07 90
08 10
09 01
10 40
Code for high speed serial encoding
11 1 Encoding 06
algorithm
12 1 BR, Nominal Nominal signaling rate, units of 100 MBd 67
13 1 Rate Identifier Type of rate select functionality 00

749 Miner Road, Highland Heights, OH 44143


PRELIMINARY Page 4 of 11 © 2023 | COTSWORKS, INC. 440.446.8800 | [email protected]
RJ-10G-DW-E
10.3125Gbps
Rugged RJ Size Fiber Optic Transceiver

Link length supported for single mode fiber,


14 1 Length (SMF, km) 50
units of km
Link length supported for single mode fiber,
15 1 Length (SMF) FF
units of 100 m
Link length supported for 50 um OM2 fiber,
16 1 Length (50um) 00
units of 10 m
Link length supported for 62.5 um OM1
17 1 Length (62.5um) 00
fiber, units of 10 m
Link length supported for 50um OM4 fiber,
Length (OM4 or units of 10m.
18 1 00
copper cable) Alternatively copper or direct attach cable,
units of m
Link length supported for 50 um OM3 fiber,
19 1 Length (OM3) 00
units of 10 m
20 43
21 4F
22 54
23 53
24 57
25 4F
26 52
27 4B
16 Vendor Name SFP vendor name (ASCII)
28 53
29 20
30 20
31 20
32 20
33 20
34 20
35 20
36 1 Transceiver Code for electronic or optical compatibility 00
37 00
38 3 Vendor OUI SFP vendor IEEE company ID 00
39 00
40 52
41 4A
42 31
43 30
44 44
45 57
46 45
47 Part number provided by SFP vendor XX
16 Vendor PN
48 (ASCII) XX
49 XX
50 XX
51 XX
52 41
53 XX
54 XX
55 XX
56 30
57 Revision level for part number provided by 30
4 Vendor rev
58 vendor (ASCII) 30
59 30

749 Miner Road, Highland Heights, OH 44143


PRELIMINARY Page 5 of 11 © 2023 | COTSWORKS, INC. 440.446.8800 | [email protected]
RJ-10G-DW-E
10.3125Gbps
Rugged RJ Size Fiber Optic Transceiver

Left Shift of
60 1 Wavelength Laser wavelength (DEC 15) 0F
Designation

Right Shift of
Laser Wavelength
61 1 Wavelength XX
Varies by ITU Channel Option
Designation
62 1 Unallocated 00
Check code for Base ID Fields (addresses
63 1 CC_BASE XX
0 to 62)
Extended ID Fields
64 Indicates which optional transceiver signals 14
2 Options
65 are implemented 14
66 1 BR, max Upper bit rate margin, units of % 00
67 1 BR, min Lower bit rate margin, units of % 28
68 XX
69 XX
70 XX
71 XX
72 XX
73 XX
74 XX
75 XX
16 Vendor SN Serial number provided by vendor (ASCII)
76 XX
77 XX
78 XX
79 XX
80 XX
81 XX
82 XX
83 XX
84 XX
85 XX
86 XX
87 XX
8 Date code Vendor's manufacturing date code
88 XX
89 XX
90 20
91 20
Indicates which type of diagnostic
Diagnostic
92 1 monitoring is implemented (if any) in the 68
Monitoring Type
transceiver
Indicates which optional enhanced features
93 1 Enhanced Options F0
are implemented (if any) in the transceiver
SFF-8472 Indicates which revision of SFF-8472 the
94 1 08
Compliance transceiver complies with
Check code for the Extended ID Fields
95 1 CC_EXT XX
(addresses 64 to 94)

749 Miner Road, Highland Heights, OH 44143


PRELIMINARY Page 6 of 11 © 2023 | COTSWORKS, INC. 440.446.8800 | [email protected]
RJ-10G-DW-E
10.3125Gbps
Rugged RJ Size Fiber Optic Transceiver

Application Schematics
HOST BOARD APPLICATION SCHEMATIC

Notes:
• Recommend host routes separate supply voltages and filtering for RJ-module transmitter and receiver as shown in the schematic above:
o FB1/FB2 ferrite bead for power supply noise suppresion; Murata BLM18KG601SN1, 0603, 600Ω @ 100MHz, 1300mA.
o C1/C4/C5/C8 bulk capacitance; Murata GRM21BR61C106KE15L, 0805, 10µF, 16V.
o C2/C3/C6/C7 de-coupling capacitors; Murata GRM155R71C104KA88D, 0402, 0.1µF, 16V.
• R1/R2 2-wire bus pull-up resistors required on host for implementing optional digital diagnostics; 4.7kΩ to 10kΩ.
• Screw or solder posts are not internally connected to signal ground. Recommend screw or solder posts be connected to chassis ground if available,
otherwise they should be tied to local signal ground.
• For host with LVPECL electrical interface contact COTSWORKS’ applications engineering.

749 Miner Road, Highland Heights, OH 44143


PRELIMINARY Page 7 of 11 © 2023 | COTSWORKS, INC. 440.446.8800 | [email protected]
RJ-10G-DW-E
10.3125Gbps
Rugged RJ Size Fiber Optic Transceiver

PCB Design Guidelines

Dimensions in inches [mm]


Unless otherwise noted, tolerance of +/- .005”

749 Miner Road, Highland Heights, OH 44143


PRELIMINARY Page 8 of 11 © 2023 | COTSWORKS, INC. 440.446.8800 | [email protected]
RJ-10G-DW-E
10.3125Gbps
Rugged RJ Size Fiber Optic Transceiver

Panel Cutout

Dimensions in inches [mm]

Standard Mechanical Dimensions

Side View, dimensions in inches [mm]


Front View, dimensions in inches [mm]

749 Miner Road, Highland Heights, OH 44143


PRELIMINARY Page 9 of 11 © 2023 | COTSWORKS, INC. 440.446.8800 | [email protected]
RJ-10G-DW-E
10.3125Gbps
Rugged RJ Size Fiber Optic Transceiver

Mounting Hardware Guidelines

Notes:
1) An example illustrating a possible hardware combination to secure RJ-10G-DW-E to host PCB.
2) For further mounting hardware options and support contact COTSWORKS.
3) When installing the RJ module:
a. Install the washers and partially tighten the screws.
b. Solder the leads.
c. Tighten the screws to 12 in-oz.

Ruggedization Notes
• Parylene Type C coating can be used for conformal coating with a 1.0 mil ± 0.2 mil thickness through a deposition
process.
• Parylene Type C has a 5600 VPM rating, withstands high temperatures, and is extremely resistant to oil, dirt, and object
impact.
• Contact COTSWORKS for all MSDS and case composition information.

Reference Information
1) IEC-60825-1 Safety of laser products.
2) IEC-60950-1 Information technology equipment – Safety.
3) SFF-8472 Management Interface for SFP+.
4) ITU-T G.694.1.

Regulatory Compliance
• COTSWORKS transceivers are Class 1 Laser Products and comply with US FDA regulations.
• These products are designed to comply with Class 1 eye safety requirements of EN (IEC) 60825 and the electrical
safety requirements of EN (IEC) 60950.

Warnings:
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free
environment is highly recommended.

Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or
indirect radiation.

749 Miner Road, Highland Heights, OH 44143


PRELIMINARY Page 10 of 11 © 2023 | COTSWORKS, INC. 440.446.8800 | [email protected]
RJ-10G-DW-E
10.3125Gbps
Rugged RJ Size Fiber Optic Transceiver

Ordering Information
RJ-10G-DW-E -xx -xx -x -x -x -x -x
RJ Form Factor ITU Channel Connector Ruggedized Operating EMI RoHS
Mounting
Wavelength Type Coating Temp Range Shield Level
10Gbps MAX
Data Rate
I:
Long Reach (SMF) ITU Channel LC: N: N: 5: Imperial
from ITU Channel Standard LC Non-coated No Shield Level 5 Screw
A:
DWDM 100Ghz Ordering Options –40° to 85°C
Spacing Table LX: R: E: 6: U:
ARINC 801 Parylene Shield Level 6 Metric
Extended Link Screw
Budget (APD RX)

Example part Number: RJ-10G-DW-E-45-LC-R-A-N-5-I


[Rugged Jack Surface Mount, 10.3125Gbps DWDM Long Reach Transceiver, Extended Link Budget, Digital Diagnostics, ITU Channel 45
Transmitting Wavelength, Standard LC Receptacle, Parylene Conformal Coated, –40° to 85°C Operating Temperature Range, No EMI Shield,
RoHS Level 5(6), Imperial Screw Thread]

ITU Channel Ordering Options


ITU Channel Center Wavelength (nm)
34 1550.12

35 1549.32

36 1548.51

37 1547.72

38 1546.92

39 1546.12

40 1545.32

41 1544.53

42 1543.73

43 1542.94

44 1542.14

45 1541.35

46 1540.56

47 1539.77

48 1538.98

49 1538.19
Contact COTSWORKS for additional wavelength options.

COTSWORKS and the COTSWORKS logo are registered trademarks of COTSWORKS, INC.
COTSWORKS reserves the right to change, alter, or revise this document without notice unless otherwise agreed to.

749 Miner Road, Highland Heights, OH 44143


PRELIMINARY Page 11 of 11 © 2023 | COTSWORKS, INC. 440.446.8800 | [email protected]