printRequestInitForReportForm
printRequestInitForReportForm
Chassis ID Path
28/Diagnostics/FH, D13A400/MID 128 Engine control unit, fault codes
Model Identity
FH 130221450
PID45 Inlet air heater status 3 Voltage above normal or shorted high
4 Voltage below normal or shorted to lower
voltage
5 Current below normal or open circuit
PID81 Particulate trap differential 0 Data valid but above normal operational range
pressure
0 Data valid but above normal operational range
2 Data erratic, intermittent, or incorrect
3 Voltage above normal or shorted high
5 Current below normal or open circuit
12 Faulty device or component
PID94 Fuel Delivery Pressure 1 Data valid but below operational range
3 Voltage above normal or shorted high
5 Current below normal or open circuit
7 Mechanical system not responding properly
1 / 13
IMPACT 3.0 Monday, 1 August 2016
PID98 Engine oil level 1 Data valid but below operational range
4 Voltage below normal or shorted to lower
voltage
5 Current below normal or open circuit
PID100 Engine oil pressure 1 Data valid but below operational range
3 Voltage above normal or shorted high
5 Current below normal or open circuit
PID 102 Boost pressure 0 Data valid but above normal operational range
2 Data erratic, intermittent, or incorrect
3 Voltage above normal or shorted high
5 Current below normal or open circuit
8 Abnormal frequency, pulse width, or period
9 Abnormal update rate
12 Faulty device or component
14 Special instructions
PID105 Turbocharger #1 Speed 0 Data valid but above normal operational range
2 Data erratic, intermittent, or incorrect
4 Voltage below normal or shorted to lower
voltage
5 Current below normal or open circuit
10 Abnormally large variations
PID107 Air filter pressure drop 0 Data valid but above normal operational range
3 Voltage above normal or shorted high
4 Voltage below normal or shorted to lower
voltage
5 Current below normal or open circuit
PID110 Engine coolant temperature 0 Data valid but above normal operational range
2 Data erratic, intermittent, or incorrect
4 Voltage below normal or shorted to lower
voltage
5 Current below normal or open circuit
7 Mechanical system not responding properly
10 Abnormally large variations
14 Special instructions
COPYRIGHT © Copyright Volvo Parts Corporation
The information contained herein is current at the time of its original distribution, but is subject to change. The reader is advised that printed copies are uncontrolled.
2 / 13
IMPACT 3.0 Monday, 1 August 2016
PID153 Crankcase pressure 0 Data valid but above normal operational range
2 Data erratic, intermittent, or incorrect
3 Voltage above normal or shorted high
5 Current below normal or open circuit
PID163 Transmission range attained 0 Data valid but above normal operational range
1 Data valid but below operational range
PID175 Engine oil temperature 0 Data valid but above normal operational range
2 Data erratic, intermittent, or incorrect
4 Voltage below normal or shorted to lower
voltage
5 Current below normal or open circuit
PID177 Gearbox oil temperature 0 Data valid but above normal operational range
PID190 Engine speed 0 Data valid but above normal operational range
3 / 13
IMPACT 3.0 Monday, 1 August 2016
PID404 Turbocharger Compressor 0 Data valid but above normal operational range
Outlet Temperature
PID411 Recirculated Engine Exh. Gas 3 Voltage above normal or shorted high
Differential Pressure
5 Current below normal or open circuit
7 Mechanical system not responding properly
8 Abnormal frequency, pulse width, or period
9 Abnormal update rate
12 Faulty device or component
14 Special instructions
PID412 EGR temperature 0 Data valid but above normal operational range
4 Voltage below normal or shorted to lower
voltage
5 Current below normal or open circuit
10 Abnormally large variations
SID18 Water in fuel drainage valve 3 Voltage above normal or shorted high
4 Voltage below normal or shorted to lower
voltage
5 Current below normal or open circuit
4 / 13
IMPACT 3.0 Monday, 1 August 2016
SID39 Engine Starter Motor Relay 0 Data valid but above normal operational range
3 Voltage above normal or shorted high
5 Current below normal or open circuit
7 Mechanical system not responding properly
10 Abnormally large variations
14 Special instructions
SID70 Air inlet heater driver #1,2,3, 3 Voltage above normal or shorted high
4 Voltage below normal or shorted to lower
voltage
5 Current below normal or open circuit
SID71 Air inlet heater driver #2 3 Voltage above normal or shorted high
4 Voltage below normal or shorted to lower
voltage
5 Current below normal or open circuit
SID78 Fuel supply pump actuator 3 Voltage above normal or shorted high
4 Voltage below normal or shorted to lower
voltage
5 Current below normal or open circuit
5 / 13
IMPACT 3.0 Monday, 1 August 2016
PPID6 Key off input sensor 3 Voltage above normal or shorted high.
5 Current below normal or open circuit
PPID8 Piston Cooling Oil Pressure 0 Data valid but above normal operational range
1 Data valid but below operational range
3 Voltage above normal or shorted high
4 Voltage below normal or shorted to lower
voltage
5 Current below normal or open circuit
PPID35 EGR mass flow 0 Data valid but above normal operational range
1 Data valid but below operational range
7 Mechanical system not responding properly
14 Special instructions
PPID41 Selected gear 0 Data valid but above normal operational range
PPID55 ECU temperature 0 Data valid but above normal operational range
4 Short-circuit-, signal cable
5 Current below normal or open circuit
PPID75 Range inhibitor solenoid valve 3 Voltage above normal or shorted high
4 Voltage below normal or shorted to lower
COPYRIGHT © Copyright Volvo Parts Corporation
The information contained herein is current at the time of its original distribution, but is subject to change. The reader is advised that printed copies are uncontrolled.
6 / 13
IMPACT 3.0 Monday, 1 August 2016
voltage
5 Current below normal or open circuit
PPID89 VGT SRA Temperature 0 Data valid but above normal operational range
PPID122 VCB compression brake 1 Data valid but below operational range
status
3 Voltage above normal or shorted high
4 Voltage below normal or shorted to lower
voltage
5 Current below normal or open circuit
PPID274 Aftertreatment reagent tank 0 Data valid but above normal operational range
temperature
1 Data valid but below operational range
7 / 13
IMPACT 3.0 Monday, 1 August 2016
PPID275 Aftertreatment reagent filter 0 Data valid but above normal operational range
temperature
1 Data valid but below operational range
2 Data erratic, intermittent, or incorrect
4 Voltage below normal or shorted to lower
voltage
5 Current below normal or open circuit
PPID278 Aftertreatment reagent level 1 Data valid but below operational range
3 Voltage above normal or shorted high
5 Current below normal or open circuit
13 Calibration value out of range
14 Special instructions
PPID326 Soot Level 0 Data valid but above normal operational range
11 Unidentifiable error
PPID333 Engine fan thermal switch 3 Voltage above normal or shorted high
4 Voltage below normal or shorted to lower
voltage
5 Current below normal or open circuit
PPID337 Ash level in the Diesel 0 Data valid but above normal operational range
COPYRIGHT © Copyright Volvo Parts Corporation
The information contained herein is current at the time of its original distribution, but is subject to change. The reader is advised that printed copies are uncontrolled.
8 / 13
IMPACT 3.0 Monday, 1 August 2016
Particulate Filter
PSID25 Aftertreatment System 0 Data valid but above normal operational range
Conditioning
7 Mechanical system not responding properly
14 Special instructions (Periodic Heat Mode not
complete)
PSID40 Insufficient reagent quality 1 Data valid but below operational range
14 Special instructions
9 / 13
IMPACT 3.0 Monday, 1 August 2016
PSID45 High NOx - Root Cause 0 Data valid but above normal operational range
Unknown
14 Special instructions
PSID47 Particulate Trap Regeneration 0 Data valid but above normal operational range
1 Data valid but below operational range
12 Faulty device or component
PSID72 Thermostat bypass valve 0 Data valid but above normal operational range
1 Data valid but below operational range
3 Voltage above normal or shorted high
4 Voltage below normal or shorted to lower
voltage
7 Mechanical system not responding properly
PSID77 ACM control unit EEPROM 3 Voltage above normal or shorted high (ECU
internal supply high)
4 Voltage below normal or shorted to lower
voltage (ECU internal supply low)
12 Faulty device or component
10 / 13
IMPACT 3.0 Monday, 1 August 2016
PSID87 Aftertreatment reagent pump 0 Data valid but above normal operational range
motor speed
1 Data valid but below operational range
10 Abnormally large variations (No signal from
pump)
PSID90 Aftertreatment reagent Dosing 1 Data valid but below operational range
system
11 Unidentifiable error
14 Special instructions
PSID91 Aftertreatment reagent 0 Data valid but above normal operational range
consumption
1 Data valid but below operational range
PSID96 Rail pressure system 0 Data valid but above normal operational range
1 Data valid but below operational range
4 Voltage below normal or shorted to lower
voltage
7 Mechanical system not responding properly
12 Faulty device or component
PSID97 Pressure Release Valve 0 Data valid but above normal operational range
7 Mechanical system not responding properly
11 Unidentifiable error
14 Special instructions
PSID98 Charge pressure system 0 Data valid but above normal operational range
1 Data valid but below operational range
11 / 13
IMPACT 3.0 Monday, 1 August 2016
voltage
5 Current below normal or open circuit
PSID115 Empty reagent tank 1 Data valid but below operational range
PSID201 Data link, MID144 9 Abnormal update rate (No contact with VECU
(MID144))
PSID202 Data link, MID140 9 Abnormal update rate (No contact with ECU
(MID140))
PSID204 Data Link, MID136 9 Abnormal update rate (No contact with ECU
(MID136))
PSID205 Data Link, MID130 9 Abnormal update rate (No contact with TECU
(MID130)
PSID206 Data link, MID222 9 Abnormal update rate (No contact with TECU
(MID222)
PSID211 Data Link, MID219 9 Abnormal update rate (No contact with TECU
(MID219)
PSID214 Data link, MID249 9 Abnormal update rate (No contact with TECU
(MID249)
12 / 13
IMPACT 3.0 Monday, 1 August 2016
1, MID 233
11 Unidentifiable error
13 / 13