FOOTING REAL

The document provides a detailed punching shear check and design for a rectangular column based on ACI 318-19 standards. It includes calculations for shear forces, moments, and shear capacities, concluding that the maximum design shear stress is 0.11 MPa with a punching shear ratio of 0.1. The concrete shear stress capacity is determined to be 1.14 MPa.

Uploaded by

the conqueror
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
15 views

FOOTING REAL

The document provides a detailed punching shear check and design for a rectangular column based on ACI 318-19 standards. It includes calculations for shear forces, moments, and shear capacities, concluding that the maximum design shear stress is 0.11 MPa with a punching shear ratio of 0.1. The concrete shear stress capacity is determined to be 1.14 MPa.

Uploaded by

the conqueror
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Design Data 24/03/2025

ACI 318-19 Punching Shear Check & Design

General Information
Story = Base Global X-Coordinate = 7.8 m
Point Label = 136 Global Y-Coordinate = 0.79 m
Column Shape = Rectangular Reinforcement Enabled = No
Column Location = Corner Prestressed Slab = No

Support Punching Check

Controlling Combination = UDSlbS6 Moment M u3 = 0.0157 kN-m


Avg. Eff. Slab Thickness = 167 mm Shear Force = 2.2761 kN
Eff. Punching Perimeter = 567.2 mm Unbalanced Moment M u2 = -0.0704 kN-m
Cover = 33 mm Unbalanced Moment M u3 = 0.0096 kN-m
Conc. Comp. Strength = 21 MPa βc =1
Reinforcement Ratio =0 βp =0
Section Inertia I 22 = 6137.6 cm⁴ λs =0
Section Inertia I 33 = 245761.9 cm⁴ Sigma cp (22) = 0 MPa
Section Inertia I 23 = 0 cm⁴ Sigma cp (33) = 0 MPa
Gamma v2 = 0.4 Sigma cp = 0 MPa
Gamma v3 = 0.616 Shear carried by tendons, V p = 0 kN
Moment M u2 = -0.176 kN-m

Punching Shear Capacity (unreinforced)


Equation Units: [N,mm]

αs = 20 ACI 318 - 19, 22.6.5.3

λ =1 ACI 318 - 19, 22.6.1.6, 19.2.4

λs =1 ACI 318 - 19, 22.5.5.1.3

f ' c = min ( f ' c , 0.689 ) ACI 318 - 19, 22.6.3.1

= min ( 0.381, 0.689 )

= 5.519E-05 MPa

v c1 = 4 · λ s · λ · f ' c ACI 318 - 19, 22.6.5.2 ( a )

= 4 · 1 · 1 · 0.381

= 1.52 MPa

ETABS v22.5.0 Page 935 of 936


Design Data 24/03/2025

v c2 = ( 2 + β4 ) · λ · λ · f '
c
s c ACI 318 - 19, 22.6.5.2 ( b )

= ( 2 + 41 ) · 1 · 1 · 0.381
= 2.28 MPa

v c3 = ( 2 + α b· d ) · λ · λ · f '
s

0
s c ACI 318 - 19, 22.6.5.2 ( c )

= ( 2 + 20567.2
· 167
) · 1 · 1 · 0.381
= 3 MPa

vc = min ( v c1, v c2, v c3 ) ϕ ACI 318 - 19, 22.6.5.2

= min ( 1.522, 2.283, 3.002 ) 0.75

= 1.14 MPa

Design Summary
Max Design Shear Stress = 0.11 MPa
Conc. Shear Stress Capacity = 1.14 MPa
Punching Shear Ratio = 0.1

ETABS v22.5.0 Page 936 of 936