FOOTING REAL
FOOTING REAL
General Information
Story = Base Global X-Coordinate = 7.8 m
Point Label = 136 Global Y-Coordinate = 0.79 m
Column Shape = Rectangular Reinforcement Enabled = No
Column Location = Corner Prestressed Slab = No
= 5.519E-05 MPa
= 4 · 1 · 1 · 0.381
= 1.52 MPa
v c2 = ( 2 + β4 ) · λ · λ · f '
c
s c ACI 318 - 19, 22.6.5.2 ( b )
= ( 2 + 41 ) · 1 · 1 · 0.381
= 2.28 MPa
v c3 = ( 2 + α b· d ) · λ · λ · f '
s
0
s c ACI 318 - 19, 22.6.5.2 ( c )
= ( 2 + 20567.2
· 167
) · 1 · 1 · 0.381
= 3 MPa
= 1.14 MPa
Design Summary
Max Design Shear Stress = 0.11 MPa
Conc. Shear Stress Capacity = 1.14 MPa
Punching Shear Ratio = 0.1