Column Base Design - 2
Column Base Design - 2
LOADING
Total ultimate load from superstructure = 309.65 KN Col: 225 x 225
Total Service load = 221.18 KN h = 225 mm
Soil bearing capacity = 150 KN/m 2 b = 225 mm
Assume footing weight is 10% of total service load
Area of base required = (243.30 ÷ 150) = 1.62 m2 Base :
Prov. = 1.00 m x 1.00 m = 1.00 m2 L = 1.00 m
Perimeter = 2 x 225 + 225 = 900 mm B = 1.00 m
Net pressure = (309.65 ÷ 1.00 ) - (0.3 x 24 x 1.4) = 299.57 KN/m 2 h= 300 mm
d = 244
DESIGN
Shear strees,vc = 309.7 x 10 3 = 1.41 N/mm 2 <0.8 √fcu
900 x 244
Punching shear : h= 300 Ø= 12 d = 244
critical perimeter = 900 + 12 x 244 = 3828 mm
2
Area within crit. perimeter = ( 225 + 3 x 244 ) = 9.16E+05 mm
Punching shear force,V = 299.57 x ( 1.00 - 0.92 ) = 25.21 KN
3 2 2
Punching shear stress,v c = 25.21 x 10 = 0.03 N/mm < 0.34 N/mm
3828 x 244
1.00 m
225
1.00 m 225
Bending Reinforcement
fcu = 20 N/mm² fy = 400 N/mm²
h = 300 mm b = 1000
d = 244 mm Ø = 12 mm
Spans 0.98
Reinf. Limit As min = 0.13 % As max = 4 % 229.60
Moment M = 22.49 KN.m 189.10
k = M / (bd² fcu) = 0.019 k < 0.156
'Requires only tension reinforcement' z = 229.6 mm
As = M / (0.95fyz) = 258 mm²
< 390 390 As < As min 390 As = 390 mm² T12 @ 200 Btm
12000 2386.76 (BW) 565 mm²