0% found this document useful (0 votes)
12 views

Test Report

This technical report from TÜV SÜD details the compliance of various washing machine models from Wuxi Little Swan Electric Co., Ltd. with the RoHS Directive 2011/65/EU and its amendments. All tested samples, including components made of plastic and metal, passed the required standards. The report emphasizes that the results pertain only to the specific samples tested and do not reflect the quality of other products in regular production.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
12 views

Test Report

This technical report from TÜV SÜD details the compliance of various washing machine models from Wuxi Little Swan Electric Co., Ltd. with the RoHS Directive 2011/65/EU and its amendments. All tested samples, including components made of plastic and metal, passed the required standards. The report emphasizes that the results pertain only to the specific samples tested and do not reflect the quality of other products in regular production.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 175

Report No. 48.400.19.7469.

00-22/01
Dated 2021-05-26

Technical Report

Client: Wuxi Little Swan Electric Co., Ltd.


No. 18, Changjiang South Road, Wuxi, Jiangsu, P. R. China

Contact person: Deng Ran


Test object: The submitted samples were received and described by client as:
Product name: Washing machine
Product Model: MFK120-U1401B/C14E-EU(A33),
MFK100-U1501B/C14E-EU(A33), MFK90-S1401B/C14E-EU(A32),
MFK80-U1401B/C14E-EU(A32), MFK70-S1401B/C14E-EU(A31),
MFK80-S1401B/C14E-EU(A31)

Additional Model : MFN90-S1203/C31E-EU(NE),


MFK60-JS1223B/C19EPV-EU(NB), MFK70-S1423B/C19EPV-EU(NB),
MFK80-S1423BI/C19EPV-EU(NB), MFK60-JS1223B/C19EP-EU(NB),
MFK80-S1423B/C19EP-EU(NB), MFK80-U1423BI/C19EPV-EU(NB),
MFK90-S1423B/C19EP-EU(NB), MFK80-U1423B/C19EPV-EU(NB),
MFK70-S1423/C19E-EU(NE), MFK80-DU1423B/C19EP-EU(NE),
MFK80-S1401BI/C14E-EU(NB), MFK90-S1401BI/C14E-EU(NB),
MFK90-S1403B/C14E-EU(NB), MFK80-DU1423B/C19EP-EU(NE),
MFE60-JU1210/C31-EU(ND), MFE60-JU1212/C31E-EU(ND),
MFE70-U1210/C31-EU(ND), MFE70-U1212/C31E-EU(ND),
MFK70-S1423/C19E-EU(NE), MFK80-DU1423B/C19EP-EU(NE),
MFN70-U1223/C31E-EU(NE), MFN60-JU1223/C31E-EU(NE),
MFN60-U1023/C31E-EU(NE),MFN80-S1423/C31E-EU(NE),
MFK70-S1223B/C19EP-EU(NB), MFK80-DU1403B/C14E-EUFB(NE),
MFK80-S1401BI/C14E-EU(NB), MFE70-U1206/C31-EU(A2)-MD,
MFE70-U1208/C31E-EU(A2), MFK80-DU1401B/C14E-EU(NE),
MFK100-DU1501B/C25E-EU(ND), MFK70-S1401B/C14E-EU(NB),
MFK80-S1401B/C14E-EU(NB), MFK80-U1401B/C14E-EU(NB),
MFK90-S1401B/C14E-EU(NB), MFK100-U1501B/C14E-EU(NB),
MFK80-DU1401B/C14E-EU(NE), MFK100-DU1501B/C25E-EU(ND)

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 1 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Tested sample Refer to next page(s).


description:

Test specification: 2011/65/EU (RoHS) Directive and 2015/863/EU (RoHS amendment) Directive
Test with reference to EN 62321-1:2013, EN 62321-2:2014, EN 62321-3-1:2014,
EN 62321-4:2014, EN 62321-5:2014, EN 62321-6:2015, EN 62321-7-1:2015, EN
62321-7-2:2017 and EN 62321-8:2017.
Test result: Refer to the data listed in following pages

Conclusion: With regard to the data of tested components, the requirements of Directive
2011/65/EU (RoHS) and 2015/863/EU are complied.

Remarks: 1. The tested samples were identified and appointed by client.


2. The result relates only to the items tested.
3. The tested materials covered by the report were declared by the manufacturer
to be used on the additional model.

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 2 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

1. Order

1.1 Date of Purchase Order,


2021-05-26

1.2 Customer’s Reference


Nil

1.3 Receipt Date of Test Sample


2019-01-24

1.4 Date of Testing


2019-01-24 – 2019-03-04

1.5 Location of Testing


TÜV SÜD Certification and Testing (China) Co., Ltd.

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 3 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

2. Description of the tested specimen

Sample No. Result Description (Material, colour) Photograph/Location

01 Pass Coating, white

02 Pass Fabric, dark green, plastic

03 Pass Tape, translucency, plastic

04 Pass Lable, silvery

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 4 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

05 Pass Shell, silvery, metal

06 Pass Foot pad, grey, plastic

07 Pass Bolt, silvery, metal

08 Pass Nut, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 5 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

09 Pass Panel, grey, plastic

10 Pass Component, white, plastic

11 Pass Clamp, white, plastic

12 Pass Lable, white, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 6 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

13 Pass Cover, white, plastic

14 Pass Bracket, silvery, metal

15 Pass Cover, white,plastic

16 Pass Sponge, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 7 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

17 Pass Clamp, white, plastic

18 Pass Frame, white, plastic

19 Pass Sponge, black, plastic

20 Pass Glue, beige

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 8 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

21 Pass Clip, silvery, metal

22 Pass Coating, white

23 Pass Board, bown, wood

24 Pass Cover, transparent grey, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 9 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

25 Pass Plating, silvery

26 Pass Frame, white, plastic

27 Pass Component, green, plastic

28 Pass Frame, grey, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 10 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

29 Pass Cover, transparence, glass

30 Pass Bracket, silvery, metal

31 Pass Bracket, white, plastic

32 Pass Screw, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 11 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

33 Pass Cushion, grey, plastic

34 Pass Tube, grey, plastic

35 Pass Enclosure, white, plastic

36 Pass Enclosure, blue, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 12 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

37 Pass Enclosure, grey, plastic

38 Pass Enclosure, white, plastic

39 Pass Beam, silvery, metal

40 Pass Enclosure, natural color, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 13 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

41 Pass Washer, black, plastic

42 Pass Inner frame, silvery, metal

43 Pass Inner Spring, silvery, metal

44 Pass Cushion, black, rubber

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 14 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

45 Pass Sleeve, silvery, metal

46 Pass Bearing enclosure, silvery, metal

47 Pass Bearing shield cover, black, plastic

48 Pass Inner frame of bearing, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 15 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

49 Pass Inner Pellet, silvery, metal

50 Pass Hoop, silvery, metal

51 Pass Spring, silvery, metal

52 Pass Clamp, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 16 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

53 Pass Bolt, silvery, metal

54 Pass Tub, silvery, metal

55 Pass Screw, silvery, metal

56 Pass Bracket, silvery, aluminium alloy

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 17 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

57 Pass Spindle, silvery, metal

58 Pass Enclosure, grey, plastic

59 Pass Wheel, silvery, aluminium alloy

60 Pass Belt, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 18 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

61 Pass Hose, grey, plastic

62 Pass Clamp, white, plastic

63 Pass Clamp, silvery, metal

64 Pass Sponge, white, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 19 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

65 Pass Sponge, black, plastic

66 Pass Hose , grey, plastic

67 Pass Hose, grey, plastic

68 Pass Sleeve, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 20 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

69 Pass Enclosure, natural color, plastic

70 Pass Washer, black, plastic

71 Pass Tube, white, plastic

72 Pass Net, white, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 21 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

73 Pass Enclosure, grey, plastic

74 Pass Enclosure, white, plastic

75 Pass Shell, white, plastic

76 Pass Pin, yellow-green, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 22 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

77 Pass Pin, nattier blue,plastic

78 Pass Spring, black, metal

79 Pass Bar, black, plastic

80 Pass Bar, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 23 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

81 Pass Sleeve, white, plastic

82 Pass Sponge, beige, plastic

83 Pass Cushion, white, plastic

84 Pass Cushion, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 24 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

85 Pass Bar, white, plastic

86 Pass Cushion, black, plastic

87 Pass Bolt, silvery, metal

88 Pass Gasket, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 25 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

89 Pass Hose, black, plastic

90 Pass Hose, white, plastic

91 Pass Sponge, black, plastic

92 Pass Hose, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 26 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

93 Pass Tube, white, plastic

94 Pass Tube, black, plastic

95 Pass Tube, white, plastic

96 Pass Hose, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 27 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

97 Pass Fabric, white, plastic

98 Pass Sponge, black, plastic

99 Pass Heating tube, silvery, metal

100 Pass Cushion, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 28 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

101 Pass Bracket, silvery, metal

102 Pass Bolt, silvery, metal

103 Pass Bracket, silvery, metal

104 Pass Contact piece, silvery, copper alloy

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 29 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

105 Pass Ceramic, blue

106 Pass Contact piece, silvery, copper alloy

107 Pass Bar, silvery, metal

108 Pass Connector, white, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 30 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

109 Pass Contact piece, silvery, copper alloy

110 Pass Screw, silvery, metal

111 Pass Clamp, silvery, metal

112 Pass Label, white

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 31 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

113 Pass Connector, beige, plastic

114 Pass Wire jacket, yellow, plastic

115 Pass Relay shell, black, plastic

116 Pass Wire, silvery, copper alloy

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 32 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

117 Pass Potting compound, black

118 Pass Sponge, black, plastic

119 Pass Silicon steel sheet, silvery, metal

120 Pass Tape, blue, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 33 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

121 Pass Wire, golden, copper alloy

122 Pass Inner shell, black, plastic

123 Pass Enclosure, white, plastic

124 Pass Washer, black, bubber

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 34 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

125 Pass Magnet ring, black

126 Pass Rotor, translucence, plastic

127 Pass Wire, golden, copper alloy

128 Pass Capacitor, red

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 35 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

129 Pass Spring, silvery, metal

130 Pass Shell, white, plastic

131 Pass Contact piece, silvery, copper alloy

132 Pass Shell, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 36 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

133 Pass Component, white, plastic

134 Pass Spring, silvery, metal

135 Pass Shell, beige, plastic

136 Pass Frame, white, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 37 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

137 Pass Frame, silvery, metal

138 Pass Frame, beige, plastic

139 Pass Wire, golden, copper alloy

140 Pass Pin, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 38 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

141 Pass Component, red, plastic

142 Pass Block, silvery, metal

143 Pass Component, black, plastic

144 Pass Pin, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 39 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

145 Pass Spring, silvery, metal

146 Pass Contact piece, golden, copper alloy

147 Pass Contact piece, silvery, copper alloy

148 Pass Contact piece, silvery, copper alloy

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 40 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

149 Pass Tube, natural color, plastic

150 Pass Bracket, silvery, metal

151 Pass Filter, blue, plastic

152 Pass Component, white, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 41 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

153 Pass Washer, black, plastic

154 Pass Frame, black, plastic

155 Pass Sleeve, white, plastic

156 Pass Wire, golden, copper alloy

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 42 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

157 Pass Contact piece, silvery, copper alloy

158 Pass Bar, silvery, metal

159 Pass Cushion, transparence, rubber

160 Pass Spring, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 43 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

161 Pass Frame, silvery, metal

162 Pass Cushion, black, rubber

163 Pass Component, white, plastic

164 Pass Frame, natura colour, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 44 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

165 Pass EMI filter shell, white, plastic

166 Pass Label, blue

167 Pass Bracket, silvery, metal

168 Pass Contact piece, silvery, copper alloy

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 45 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

169 Pass Potting compound, black, plastic

170 Pass Wire, golden, copper alloy

171 Pass Enclosure, white, plastic

172 Pass Capacitor, blue, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 46 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

173 Pass Pin, silvery, metal

174 Pass Solder, silvery, alloy

175 Pass Resistor, blue

176 Pass Capacitor shell, grey, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 47 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

177 Pass Resin, white

178 Pass Film, silvery, plastic

179 Pass Enclosure, grey, plastic

180 Pass Lid, dark grey, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 48 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

181 Pass Enclosure, light blue,plastic

182 Pass Glue, white

183 Pass Silicon steel sheet, silvery, metal

184 Pass Label, silvery

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 49 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

185 Pass Contact piece, silvery, copper alloy

186 Pass Wire jacket, black, plastic

187 Pass Heat shrinkable tube, black, plastic

188 Pass Wire, silvery, copper alloy

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 50 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

189 Pass Frame, white, plastic

190 Pass Spindle, silvery, metal

191 Pass Frame, white, plastic

192 Pass Magnet, black

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 51 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

193 Pass Sleeve, golden, copper alloy

194 Pass Component, black, plastic

195 Pass Cushion, black, plastic

196 Pass Washer, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 52 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

197 Pass Lid, black, plastic

198 Pass Frame, white, plastic

199 Pass Washer, black, plastic

200 Pass Washer, white, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 53 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

201 Pass Gasket, white, plastic

202 Pass Gasket, white, plastic

203 Pass Washer, black, plastic

204 Pass Washer, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 54 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

205 Pass Screw, silvery, metal

206 Pass Fan, white, plastic

Motor shell, silvery grey, aluminium


207 Pass
alloy

208 Pass Gasket, grey, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 55 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

209 Pass Cushion, black, plastic

210 Pass Rivet, silvery, metal

211 Pass Silicon steel sheet, silvery, metal

212 Pass Contact piece, silvery, copper alloy

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 56 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

213 Pass Frame, beige, plastic

214 Pass Label, silvery

215 Pass Wire, golden, copper alloy

216 Pass Insulation sheet, grey, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 57 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

217 Pass Belt pulley, black, metal

218 Pass Spindle, silvery, metal

219 Pass Bearing enclosure, silvery, metal

220 Pass Bearing shield, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 58 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

221 Pass Inner frame of bearing, silvery, metal

222 Pass Pellet, silvery, metal

223 Pass Rotor frame, white, plastic

224 Pass Silicon steel sheet, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 59 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

225 Pass Gasket, black, metal

226 Pass Bolt, silvery, metal

227 Pass Gasket, silvery, metal

228 Pass Ring, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 60 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

229 Pass Cable tie, light green, plastic

230 Pass Shell, white, plastic

Cooling fin, silvery grey, aluminium


231 Pass
alloy

232 Pass Hose, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 61 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

233 Pass Contact piece, silvery, copper alloy

234 Pass Wire jacket, blue, plastic

235 Pass Wire jacket, brown, plastic

236 Pass Wire jacket, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 62 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

237 Pass Wire, silvery, copper alloy

238 Pass Contactor, beige, plastic

239 Pass Wire jacket, white, plastic

240 Pass Wire jacket, yellow, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 63 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

241 Pass Wire jacket, blue, plastic

242 Pass Wire jacket, red, plastic

243 Pass Wire, silvery, copper alloy

244 Pass Jacket, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 64 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

245 Pass Potting, black, plastic

246 Pass Lid, brown, plastic

247 Pass Shell, silvery, metal

248 Pass Tape, transparence, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 65 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

249 Pass Pin, silvery, metal

250 Pass Foil, silvery, metal

251 Pass Film, yellow, plastic

252 Pass Frame, white, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 66 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

253 Pass Tape, red, plastic

254 Pass Tape, white, plastic

255 Pass Tape, black, plastic

256 Pass Wire jacket, brown, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 67 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

257 Pass Wire jacket , red, plastic

258 Pass Wire jacket , yellow, plastic

259 Pass Wire jacket , white, plastic

260 Pass Wire jacket , orange, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 68 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

261 Pass Wire jacket , black, plastic

262 Pass Wire jacket , dark blue, plastic

263 Pass Wire jacket , pink, plastic

264 Pass Wire jacket , blue, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 69 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

265 Pass Wire, silvery, copper alloy

266 Pass Magnet frame, black

267 Pass Wire, golden, copper alloy

268 Pass Contact piece, silvery, copper alloy

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 70 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

269 Pass Connector, white, plastic

270 Pass Connector, beige, plastic

271 Pass Connector, blue, plastic

272 Pass Cushiong,grey, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 71 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

273 Pass Clasp, white, plastic.

274 Pass Connector, black, plastic

275 Pass Clamp, black, plastic

276 Pass Clamp, orange, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 72 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

277 Pass Connector, beige, plastic

278 Pass Contact piece, silvery, copper alloy

279 Pass Label, white

280 Pass Sponge, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 73 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

281 Pass Screw, black, plastic

282 Pass Cable tie, white, plastic

283 Pass Screw, silvery, metal

284 Pass Clamp, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 74 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

285 Pass Gasket, silvery, metal

286 Pass Bolt, silvery, metal

287 Pass Screw, silvery, metal

288 Pass Screw, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 75 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

289 Pass Nut, silvery, metal

290 Pass Screw, black, metal

291 Pass Clamp, silvery, metal

292 Pass Gasket, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 76 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

293 Pass Wire jacket, white, plastic

294 Pass Cable tie, white, plastic

295 Pass Shell, white, plastic

296 Pass Frame, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 77 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

297 Pass Panel, transparency, plastic

Cap, black,
298 Pass
plastic

299 Pass Key pad, white, rubber

300 Pass Pad, translucency white, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 78 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

301 Pass Key switch, white, plastic

302 Pass Rotary switch, transparency, plastic

303 Pass Rotary switch, white, plastic

304 Pass Ratary switch, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 79 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

305 Pass Key switch, white, plastic

306 Pass Coating, silveryy

307 Pass Panel, black, plastic

308 Pass Screw, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 80 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

309 Pass Screw, silvery, metal

310 Pass Label, green, plastic

311 Pass Label, white, plastic

312 Pass Label, white, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 81 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

313 Pass Glue, beige, plastic

314 Pass Socket, beige, plastic

315 Pass Socket pin, silvery, metal

316 Pass Socket, beige, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 82 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

317 Pass Socket pin, silvery, metal

318 Pass Socket, beige, plastic

319 Pass Socket pin, silvery, metal

320 Pass Relay shell, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 83 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

321 Pass Slice, golden, copper alloy

322 Pass Subassembly, silvery, metal

323 Pass Subassembly, silvery, metal

324 Pass Wire, golden, copper alloy

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 84 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

325 Pass Frame, black, plastic

326 Pass Stitch, silvery, metal

327 Pass Slice, golden, copper alloy

328 Pass Frame, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 85 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

329 Pass Contactor, silvery, metal

330 Pass Frame, black, plastic

331 Pass Relay shell, white, plastic

332 Pass Pouring sealant, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 86 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

333 Pass Subassembly, silvery, metal

334 Pass Wire, golden, copper alloy

335 Pass Silce, silvery, metal

336 Pass Slice, golden, copper alloy

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 87 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

337 Pass Slice, silvery, metal

338 Pass Slice, golden, copper alloy

339 Pass Stitch, silvery, metal

340 Pass Capacitor shell, yellow, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 88 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

341 Pass Stitch, silvery, metal

342 Pass Pouring sealant, yellow, rubber

343 Pass Subassembly, silvery, plastic

344 Pass Inductor skin, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 89 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

345 Pass Magnet, black

346 Pass Stitch, silvery, metal

347 Pass Wire, golden, copper alloy

348 Pass Capacitor, green, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 90 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

349 Pass Capacitor skin, black, plastic

350 Pass Capacitor, yellow, plastic

351 Pass Stitch, silvery, metal

352 Pass Capacitor skin, green, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 91 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

353 Pass Capacitor shell, silvery, metal

354 Pass Pad, black, rubber

355 Pass Filler, yellow, plastic

356 Pass Capacitor skin, purple, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 92 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

357 Pass Stitch, silvery, metal

358 Pass Audion, black, plastic

359 Pass Stitch, silvery, metal

360 Pass Diode, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 93 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

361 Pass Stitch, silvery, metal

362 Pass Resister, light green, plastic

363 Pass Stitch, silvery, metal

364 Pass PCB, green, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 94 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

365 Pass Solder, silvery, metal

366 Pass Silicon controlled, black, plastic

367 Pass IC, black, plastic

368 Pass IC, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 95 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

369 Pass IC, black, plastic

370 Pass IC, black, plastic

371 Pass IC, black, plastic

372 Pass Audion, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 96 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

373 Pass Diode, Black, plastic

374 Pass Chip resister, black, plastic

375 Pass Chip capacitor, plastic

376 Pass Crystal oscillator, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 97 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

377 Pass Wire, silvery, copper alloy

378 Pass Wire jacket, pink, plastic

379 Pass Socket, White, plastic

380 Pass Resister, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 98 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

381 Pass Key switch, grey, plastic

382 Pass Key switch shell, black, plastic

383 Pass Pad, black, rubber

384 Pass Pad, yellow, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 99 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

385 Pass Pad, black, plastic

386 Pass Gasket, silvery,metal

387 Pass Slice, silvery,metal

388 Pass Key switch shell, black, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 100 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

389 Pass Key switch shell, blue, plastic

390 Pass Pad, transluceny, rubber

391 Pass Slice, silvery,metal

392 Pass LED, transparence, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 101 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

393 Pass Stitch,silvery, metal

394 Pass PCB, green, plastic

395 Pass Solder, silvery, metal

396 Pass Clasp, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 102 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

397 Pass Rotary switch,black, plastic

398 Pass Slice, silvery, metal

399 Pass Shell, silvery, metal

400 Pass Shell, silvery, metal

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 103 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

401 Pass Gaster, golden, copper alloy

402 Pass Gasket, black, plastic

403 Pass Shell, green, plastic

404 Pass Contact piece, silvery, copper alloy

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 104 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

405 Pass Solder, silvery, metal

406 Pass Chip capacitor, plastic

407 Pass PCB, green, plastic

408 Pass Wire jacket, red, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 105 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

409 Pass Wire jacket, purple, plastic

410 Pass Coating, black, plastic

411 Pass Shell, white, plastic

Pouring, sealant, translucency ,


412 Pass
plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 106 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

413 Pass Plug, black, plastic

414 Pass Pin, silvery, metal

415 Pass LED, transparence, plastic

416 Pass PCB, green, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 107 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

417 Pass Shell, black, plastic

418 Pass Pin, silvery, metal

419 Pass Ring, golden, copper alloy

420 Pass Component, white

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 108 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

421 Pass PCB, green, plastic

422 Pass Solder, silvery, alloy

423 Pass IC, black

424 Pass Resistor, black

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 109 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

425 Pass Capacitor, yellow

426 Pass Diode, black

427 Pass Cable, grey, plastic

428 Pass Sleeve, grey, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 110 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

429 Pass Cable, yellow green, plastic

430 Pass Cable, blue, plastic

431 Pass Cable, brown, plastic

432 Pass Socket, white, plastic

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 111 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

433 Pass Socket, black, plastic

434 Pass Plug, grey, plastic

435 Pass Component, black, plastic

436 Pass Pin, silvery, copper alloy

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 112 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Sample No. Result Description (Material, colour) Photograph/Location

437 Pass Contact piece, silvery, copper alloy

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 113 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

3. Test Results

3.1 ED-XRF Spectrometer test for total Cadmium, Chromium, Mercury, Lead and Bromine according to
EN 62321-3-1:2014

Criteria of XRF test results

Pass:

Because of the nature of the testing procedure (caused by the uncertainty of the used, XRF method), a definite
pass is given only if the XRF test score is less than 60% of the respective RoHS limit.

Inconclusive:

If the XRF test score is between 60% and 150% of the respective RoHS limit, further chemical test on the
sample is required.

Fail:

A definite FAIL is given if the XRF test score is above 150% of the respective RoHS limit

*Explanation for RoHS limit

Regarding Chromium and Bromine, the XRF test score shows the total Chromium and the total Bromine, but the
RoHS limit of 1000 mg/kg, according to the directive 2011/65/EU, is only for Hexavalent Chromium and
Brominated Flame Retardants. Therefore, if the XRF test result for the total Chromium and the total Bromine is
more than 600 mg/kg and 300 mg/kg respectively, further analytical tests are necessary to find out the exact
amount of Hexavalent Chromium and Brominated Flame Retardants

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 114 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

01 <30 <30 <30 79 <30 Pass

02 <30 <30 <30 <30 <30 Pass

03 <30 <30 <30 <30 <30 Pass

04 <30 <30 <30 <30 <30 Pass

05 <30 42 <30 535 -- Pass

06 <30 <30 <30 <30 360 Inconclusive

07 <30 <30 <30 413 -- Pass

08 <30 32 <30 472 -- Pass

09 <30 <30 <30 <30 <30 Pass

10 <30 <30 <30 <30 <30 Pass

11 <30 <30 <30 <30 <30 Pass

12 <30 <30 <30 <30 <30 Pass

13 <30 <30 <30 <30 <30 Pass

14 <30 <30 <30 <30 -- Pass

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 115 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

15 <30 <30 <30 <30 <30 Pass

16 <30 <30 <30 <30 <30 Pass

17 <30 <30 <30 <30 <30 Pass

18 <30 <30 <30 <30 <30 Pass

19 <30 <30 <30 <30 <30 Pass

20 <30 <30 <30 <30 <30 Pass

21 <30 <30 <30 <30 -- Pass

22 <30 <30 <30 <30 <30 Pass

23 <30 <30 <30 <30 <30 Pass

24 <30 <30 <30 <30 <30 Pass

25 <30 <30 <30 7796 -- Inconclusive

26 <30 <30 <30 <30 <30 Pass

27 <30 <30 <30 <30 <30 Pass

28 <30 <30 <30 <30 <30 Pass

29 <30 <30 <30 <30 <30 Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 116 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

30 <30 187 <30 2314 -- Inconclusive

31 <30 <30 <30 <30 <30 Pass

32 <30 59 <30 1794 -- Inconclusive

33 <30 <30 <30 <30 <30 Pass

34 <30 <30 <30 <30 <30 Pass

35 <30 <30 <30 <30 <30 Pass

36 <30 <30 <30 <30 <30 Pass

37 <30 <30 <30 <30 <30 Pass

38 <30 <30 <30 <30 <30 Pass

39 <30 95 <30 1726 -- Inconclusive

40 <30 <30 <30 <30 <30 Pass

41 <30 <30 <30 <30 <30 Pass

42 <30 39 <30 257 -- Pass

43 <30 57 <30 98572 -- Inconclusive

44 <30 <30 <30 <30 <30 Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 117 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

45 <30 <30 <30 7579 -- Inconclusive

46 <30 <30 <30 19231 -- Inconclusive

47 <30 <30 <30 <30 <30 Pass

48 <30 116 <30 472 -- Pass

49 <30 88 <30 10235 -- Inconclusive

50 <30 150 <30 <30 -- Pass

51 <30 <30 <30 <30 -- Pass

52 <30 140 <30 67 -- Pass

53 <30 <30 <30 289 -- Pass

54 <30 48 <30 97345 -- Inconclusive

55 <30 <30 <30 76610 -- Inconclusive

56 <30 316 <30 268 -- Pass

57 <30 131 <30 9646 -- Inconclusive

58 <30 <30 <30 <30 <30 Pass

59 <30 230 <30 <30 -- Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 118 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

60 <30 <30 <30 <30 <30 Pass

61 <30 <30 <30 <30 <30 Pass

62 <30 <30 <30 <30 <30 Pass

63 <30 46 <30 912 -- Inconclusive

64 <30 <30 <30 <30 <30 Pass

65 <30 <30 <30 <30 <30 Pass

66 <30 <30 <30 <30 <30 Pass

67 <30 <30 <30 <30 <30 Pass

68 <30 <30 <30 <30 -- Pass

69 <30 <30 <30 <30 <30 Pass

70 <30 <30 <30 <30 <30 Pass

71 <30 <30 <30 <30 <30 Pass

72 <30 <30 <30 <30 <30 Pass

73 <30 <30 <30 <30 <30 Pass

74 <30 <30 <30 <30 <30 Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 119 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

75 <30 <30 <30 50 <30 Pass

76 <30 <30 <30 <30 <30 Pass

77 <30 <30 <30 <30 <30 Pass

78 <30 46 <30 1778 -- Inconclusive

79 <30 <30 <30 <30 <30 Pass

80 <30 <30 <30 <30 -- Pass

81 <30 <30 <30 <30 <30 Pass

82 <30 <30 <30 <30 <30 Pass

83 <30 <30 <30 <30 <30 Pass

84 <30 <30 <30 <30 <30 Pass

85 <30 <30 <30 <30 <30 Pass

86 <30 <30 <30 <30 <30 Pass

87 <30 78 <30 1217 -- Inconclusive

88 <30 45 <30 642 -- Inconclusive

89 <30 <30 <30 30 <30 Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 120 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

90 36 <30 <30 <30 26641 Inconclusive

91 <30 <30 <30 <30 <30 Pass

92 <30 <30 <30 <30 <30 Pass

93 <30 <30 <30 <30 <30 Pass

94 <30 <30 <30 <30 <30 Pass

95 <30 <30 <30 <30 <30 Pass

96 <30 <30 <30 <30 <30 Pass

97 <30 <30 <30 <30 <30 Pass

98 <30 <30 <30 <30 <30 Pass

99 <30 <30 <30 19217 -- Inconclusive

100 <30 <30 <30 <30 <30 Pass

101 <30 54 <30 614 -- Inconclusive

102 <30 <30 <30 12735 -- Inconclusive

103 <30 <30 <30 7813 -- Inconclusive

104 <30 <30 <30 <30 -- Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 121 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

105 <30 <30 <30 32 32953 Inconclusive

106 <30 <30 <30 <30 -- Pass

107 <30 <30 <30 73426 -- Inconclusive

108 <30 <30 <30 <30 34205 Inconclusive

109 <30 <30 <30 <30 -- Pass

110 <30 <30 <30 13527 -- Inconclusive

111 <30 143 <30 726 -- Inconclusive

112 <30 <30 <30 <30 <30 Pass

113 <30 <30 <30 <30 49403 Inconclusive

114 <30 <30 <30 <30 <30 Pass

115 <30 <30 <30 <30 39652 Inconclusive

116 <30 <30 <30 <30 -- Pass

117 <30 <30 <30 <30 <30 Pass

118 <30 <30 <30 <30 <30 Pass

119 <30 71 <30 1738 -- Inconclusive


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 122 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

120 <30 <30 <30 <30 <30 Pass

121 <30 <30 <30 <30 -- Pass

122 <30 <30 <30 <30 <30 Pass

123 <30 <30 <30 <30 <30 Pass

124 <30 <30 <30 <30 <30 Pass

125 <30 <30 <30 <30 -- Pass

126 <30 <30 <30 <30 <30 Pass

127 <30 <30 <30 <30 -- Pass

128 <30 <30 <30 <30 <30 Pass

129 <30 76 <30 17101 -- Inconclusive

130 <30 <30 <30 <30 <30 Pass

131 <30 <30 <30 <30 -- Pass

132 <30 <30 <30 <30 <30 Pass

133 <30 <30 <30 <30 <30 Pass

134 <30 <30 <30 175 -- Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 123 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

135 <30 <30 <30 <30 61224 Inconclusive

136 <30 <30 <30 <30 <30 Pass

137 <30 37 <30 5650 -- Inconclusive

138 <30 <30 <30 <30 59588 Inconclusive

139 <30 <30 <30 <30 -- Pass

140 <30 <30 <30 <30 -- Pass

141 <30 <30 <30 <30 <30 Pass

142 <30 70 <30 12973 -- Inconclusive

143 <30 <30 <30 <30 <30 Pass

144 <30 <30 <30 <30 -- Pass

145 <30 <30 <30 8428 -- Inconclusive

146 <30 <30 <30 <30 -- Pass

147 <30 <30 <30 <30 -- Pass

148 <30 <30 <30 <30 -- Pass

149 <30 <30 <30 <30 <30 Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 124 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

150 <30 <30 <30 438 -- Pass

151 <30 <30 <30 <30 <30 Pass

152 <30 <30 <30 <30 <30 Pass

153 <30 <30 <30 <30 <30 Pass

154 <30 <30 <30 <30 129 Pass

155 <30 <30 <30 <30 35905 Inconclusive

156 <30 <30 <30 <30 -- Pass

157 <30 <30 <30 <30 -- Pass

158 <30 53 <30 17928 -- Inconclusive

159 <30 <30 <30 61 <30 Pass

160 <30 43 <30 34772 -- Inconclusive

161 <30 <30 <30 468 -- Pass

162 <30 <30 <30 <30 <30 Pass

163 <30 <30 <30 <30 <30 Pass

164 <30 <30 <30 <30 <30 Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 125 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

165 <30 <30 <30 <30 <30 Pass

166 <30 <30 <30 <30 <30 Pass

167 <30 <30 <30 64 -- Pass

168 <30 <30 <30 <30 -- Pass

169 <30 <30 <30 32 <30 Pass

170 <30 <30 <30 <30 -- Pass

171 <30 <30 <30 <30 <30 Pass

172 <30 <30 <30 <30 <30 Pass

173 <30 <30 <30 <30 -- Pass

174 <30 <30 <30 <30 -- Pass

175 <30 <30 <30 <30 <30 Pass

176 <30 <30 <30 40 37835 Inconclusive

177 <30 <30 <30 <30 34557 Inconclusive

178 <30 <30 <30 <30 <30 Pass

179 <30 <30 <30 <30 <30 Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 126 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

180 <30 <30 <30 <30 2049 Inconclusive

181 <30 <30 <30 <30 <30 Pass

182 <30 <30 <30 39 <30 Pass

183 <30 84 <30 2746 -- Inconclusive

184 <30 <30 <30 <30 <30 Pass

185 <30 <30 <30 <30 -- Pass

186 <30 <30 <30 <30 <30 Pass

187 <30 <30 <30 <30 <30 Pass

188 <30 <30 <30 <30 -- Pass

189 <30 <30 <30 <30 <30 Pass

190 <30 34 <30 29236 -- Inconclusive

191 <30 <30 <30 <30 <30 Pass

192 <30 <30 <30 237 -- Pass

193 <30 29896** <30 <30 -- Inconclusive

194 <30 57 <30 <30 <30 Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 127 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

195 <30 49 <30 <30 <30 Pass

196 <30 37 <30 <30 <30 Pass

197 <30 <30 <30 <30 <30 Pass

198 <30 <30 <30 <30 <30 Pass

199 <30 31 <30 <30 <30 Pass

200 <30 31 <30 <30 <30 Pass

201 <30 <30 <30 <30 <30 Pass

202 <30 <30 <30 <30 <30 Pass

203 <30 31 <30 <30 <30 Pass

204 <30 63 <30 <30 <30 Pass

205 <30 88 <30 154 -- Pass

206 <30 <30 <30 <30 <30 Pass

207 <30 230 <30 <30 -- Pass

208 <30 47 <30 <30 <30 Pass

209 <30 <30 <30 <30 <30 Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 128 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

210 <30 60 <30 <30 -- Pass

211 <30 44 <30 3167 -- Inconclusive

212 <30 <30 <30 <30 -- Pass

213 <30 <30 <30 <30 57111 Inconclusive

214 <30 <30 <30 <30 <30 Pass

215 <30 <30 <30 <30 -- Pass

216 <30 <30 <30 <30 <30 Pass

217 <30 272 <30 825 -- Inconclusive

218 <30 125 <30 3275 -- Inconclusive

219 <30 65 <30 13274 -- Inconclusive

220 <30 <30 <30 <30 -- Pass

221 <30 278 <30 585 -- Pass

222 <30 <30 <30 12597 -- Inconclusive

223 <30 <30 <30 <30 <30 Pass

224 <30 46 <30 264 -- Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 129 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

225 <30 140 <30 1328 -- Inconclusive

226 <30 160 <30 990 -- Inconclusive

227 <30 321 <30 147 -- Pass

228 <30 <30 <30 240 -- Pass

229 <30 <30 <30 <30 1186 Inconclusive

230 <30 <30 <30 59 712 Inconclusive

231 <30 140 <30 <30 -- Pass

232 <30 <30 <30 <30 <30 Pass

233 <30 <30 <30 <30 -- Pass

234 <30 <30 <30 <30 <30 Pass

235 <30 <30 <30 <30 <30 Pass

236 <30 <30 <30 <30 <30 Pass

237 <30 <30 <30 <30 -- Pass

238 <30 <30 <30 <30 55043 Inconclusive

239 <30 <30 <30 <30 <30 Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 130 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

240 <30 <30 <30 <30 <30 Pass

241 <30 <30 <30 <30 <30 Pass

242 <30 <30 <30 <30 <30 Pass

243 <30 <30 <30 <30 -- Pass

244 <30 <30 <30 40 <30 Pass

245 <30 <30 <30 <30 <30 Pass

246 <30 <30 <30 <30 <30 Pass

247 <30 <30 <30 <30 -- Pass

248 <30 <30 <30 35 <30 Pass

249 <30 <30 <30 <30 -- Pass

250 <30 <30 <30 <30 -- Pass

251 <30 <30 <30 42 <30 Pass

252 <30 <30 <30 <30 <30 Pass

253 <30 <30 <30 <30 130 Pass

254 <30 <30 <30 <30 <30 Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 131 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

255 <30 <30 <30 <30 <30 Pass

256 <30 <30 <30 34 <30 Pass

257 <30 <30 <30 <30 <30 Pass

258 <30 <30 <30 <30 <30 Pass

259 <30 <30 <30 <30 <30 Pass

260 <30 <30 <30 <30 <30 Pass

261 <30 <30 <30 <30 <30 Pass

262 <30 <30 <30 <30 <30 Pass

263 <30 <30 <30 <30 <30 Pass

264 <30 <30 <30 <30 <30 Pass

265 <30 <30 <30 <30 -- Pass

266 <30 <30 <30 <30 <30 Pass

267 <30 <30 <30 <30 -- Pass

268 <30 <30 <30 <30 -- Pass

269 <30 <30 <30 <30 52129 Inconclusive


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 132 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

270 <30 <30 <30 <30 56239 Inconclusive

271 <30 <30 <30 <30 55503 Inconclusive

272 <30 <30 <30 <30 <30 Pass

273 <30 <30 <30 <30 <30 Pass

274 <30 <30 <30 <30 51923 Inconclusive

275 <30 <30 <30 <30 55167 Inconclusive

276 <30 <30 <30 <30 54892 Inconclusive

277 <30 <30 <30 <30 49866 Inconclusive

278 <30 <30 <30 <30 -- Pass

279 <30 <30 <30 <30 <30 Pass

280 <30 <30 <30 69 <30 Pass

281 <30 <30 <30 <30 168 Pass

282 <30 <30 <30 <30 <30 Pass

283 <30 46 <30 837 -- Inconclusive

284 <30 72 <30 513 -- Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 133 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

285 <30 43 <30 277 -- Pass

286 <30 87 <30 452 -- Pass

287 <30 76 <30 1002 -- Inconclusive

288 <30 <30 <30 18352 -- Inconclusive

289 <30 <30 <30 1146 -- Inconclusive

290 <30 <30 <30 614 -- Inconclusive

291 <30 170 <30 764 -- Inconclusive

292 <30 <30 <30 1764 -- Inconclusive

293 <30 <30 <30 48 <30 Pass

294 <30 <30 <30 <30 <30 Pass

295 <30 <30 <30 <30 <30 Pass

296 <30 <30 <30 <30 5348 Inconclusive

297 <30 <30 <30 <30 <30 Pass

298 <30 <30 <30 <30 <30 Pass

299 <30 <30 <30 <30 <30 Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 134 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

300 <30 <30 <30 <30 <30 Pass

301 <30 <30 <30 <30 <30 Pass

302 <30 <30 <30 <30 <30 Pass

303 <30 <30 <30 <30 <30 Pass

304 <30 <30 <30 <30 <30 Pass

305 <30 <30 <30 <30 <30 Pass

306 <30 <30 <30 <30 <30 Pass

307 <30 <30 <30 <30 <30 Pass

308 <30 92 <30 335 -- Pass

309 <30 <30 <30 <30 -- Pass

310 <30 <30 <30 <30 <30 Pass

311 <30 <30 <30 <30 <30 Pass

312 <30 <30 <30 <30 <30 Pass

313 <30 <30 <30 <30 38269 Inconclusive

314 <30 <30 <30 <30 48956 Inconclusive


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 135 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

315 <30 <30 <30 <30 -- Pass

316 <30 <30 <30 <30 42317 Inconclusive

317 <30 <30 <30 <30 -- Pass

318 <30 <30 <30 <30 51849 Inconclusive

319 <30 <30 <30 <30 -- Pass

320 <30 <30 <30 <30 44780 Inconclusive

321 <30 <30 <30 <30 -- Pass

322 <30 <30 <30 513 -- Pass

323 <30 <30 <30 3968 -- Inconclusive

324 <30 <30 <30 <30 -- Pass

325 <30 <30 <30 <30 40472 Inconclusive

326 <30 <30 <30 <30 -- Pass

327 <30 <30 <30 <30 -- Pass

328 <30 <30 <30 41 42856 Inconclusive

329 <30 <30 <30 <30 -- Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 136 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

330 <30 <30 <30 49 56592 Inconclusive

331 <30 <30 <30 <30 36371 Inconclusive

332 <30 <30 <30 <30 <30 Pass

333 <30 43 <30 2792 -- Inconclusive

334 <30 <30 <30 <30 -- Pass

335 <30 59 <30 1635 -- Inconclusive

336 <30 <30 <30 <30 -- Pass

337 <30 64 <30 1934 -- Inconclusive

338 <30 <30 <30 <30 -- Pass

339 <30 <30 <30 <30 -- Pass

340 <30 <30 <30 <30 31325 Inconclusive

341 <30 <30 <30 <30 -- Pass

342 <30 <30 <30 <30 957 Inconclusive

343 <30 <30 <30 <30 <30 Pass

344 <30 <30 <30 <30 <30 Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 137 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

345 <30 <30 <30 <30 -- Pass

346 <30 <30 <30 <30 -- Pass

347 <30 <30 <30 <30 -- Pass

348 <30 <30 <30 <30 <30 Pass

349 <30 <30 <30 <30 <30 Pass

350 <30 100 <30 <30 <30 Pass

351 <30 <30 <30 <30 -- Pass

352 <30 <30 <30 <30 <30 Pass

353 <30 <30 <30 <30 -- Pass

354 <30 <30 <30 <30 <30 Pass

355 <30 <30 <30 <30 <30 Pass

356 <30 <30 <30 <30 <30 Pass

357 <30 <30 <30 <30 -- Pass

358 <30 <30 <30 <30 8946 Inconclusive

359 <30 <30 <30 <30 -- Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 138 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

360 <30 <30 <30 <30 6646 Inconclusive

361 <30 <30 <30 <30 -- Pass

362 <30 <30 <30 2035 <30 Inconclusive

363 <30 <30 <30 <30 -- Pass

364 <30 <30 <30 37 35456 Inconclusive

365 <30 <30 <30 <30 -- Pass

366 <30 <30 <30 <30 18923 Inconclusive

367 <30 <30 <30 <30 17237 Inconclusive

368 <30 <30 <30 <30 8235 Inconclusive

369 <30 <30 <30 <30 15247 Inconclusive

370 <30 <30 <30 <30 19673 Inconclusive

371 <30 <30 <30 <30 17249 Inconclusive

372 <30 <30 <30 <30 15523 Inconclusive

373 <30 <30 <30 <30 38269 Inconclusive

374 <30 332 <30 <30 15779 Inconclusive


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 139 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

375 <30 <30 <30 <30 12386 Inconclusive

376 <30 <30 <30 <30 -- Pass

377 <30 <30 <30 <30 -- Pass

378 <30 <30 <30 <30 <30 Pass

379 <30 <30 <30 <30 <30 Pass

380 <30 236 <30 <30 7803 Inconclusive

381 <30 <30 <30 <30 48574 Inconclusive

382 <30 <30 <30 <30 <30 Pass

383 <30 <30 <30 <30 <30 Pass

384 <30 <30 <30 <30 <30 Pass

385 <30 <30 <30 <30 651 Inconclusive

386 <30 <30 <30 5137 -- Inconclusive

387 <30 <30 <30 <30 -- Pass

388 <30 <30 <30 <30 <30 Pass

389 <30 <30 <30 <30 <30 Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 140 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

390 <30 <30 <30 <30 <30 Pass

391 <30 <30 <30 <30 -- Pass

392 <30 <30 <30 <30 <30 Pass

393 <30 <30 <30 <30 -- Pass

394 <30 <30 <30 <30 28835 Inconclusive

395 <30 <30 <30 <30 -- Pass

396 <30 <30 <30 <30 -- Pass

397 <30 <30 <30 <30 <30 Pass

398 <30 <30 <30 <30 -- Pass

399 <30 <30 <30 <30 -- Pass

400 <30 98 <30 <30 -- Pass

401 <30 <30 <30 <30 -- Pass

402 <30 <30 <30 <30 <30 Pass

403 <30 <30 <30 <30 36454 Inconclusive

404 <30 <30 <30 <30 -- Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 141 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

405 <30 <30 <30 <30 -- Pass

406 <30 <30 <30 <30 8925 Inconclusive

407 <30 <30 <30 <30 27349 Inconclusive

408 <30 <30 <30 <30 <30 Pass

409 <30 <30 <30 <30 <30 Pass

410 <30 <30 <30 <30 <30 Pass

411 <30 <30 <30 <30 <30 Pass

412 <30 <30 <30 <30 <30 Pass

413 <30 <30 <30 <30 5191 Inconclusive

414 <30 <30 <30 <30 -- Pass

415 <30 <30 <30 <30 <30 Pass

416 <30 <30 <30 <30 42318 Inconclusive

417 <30 <30 <30 <30 <30 Pass

418 <30 <30 <30 <30 -- Pass

419 <30 <30 <30 <30 -- Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 142 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

420 57 57793*** <30 <30 <30 Pass

421 <30 <30 <30 <30 25316 Inconclusive

422 <30 <30 <30 <30 -- Pass

423 <30 <30 <30 <30 9732 Inconclusive

424 <30 208 <30 <30 16357 Inconclusive

425 <30 <30 <30 <30 13105 Inconclusive

426 <30 <30 <30 <30 12648 Inconclusive

427 <30 <30 <30 <30 <30 Pass

428 <30 <30 <30 <30 <30 Pass

429 <30 <30 <30 <30 <30 Pass

430 <30 <30 <30 <30 <30 Pass

431 <30 <30 <30 <30 <30 Pass

432 <30 <30 <30 <30 43255 Inconclusive

433 <30 <30 <30 <30 45134 Inconclusive

434 <30 <30 <30 <30 <30 Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 143 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

TOTAL TOTAL TOTAL TOTAL TOTAL OVERALL


CADMIUM LEAD MERCURY CHROMIUM BROMINE RESULT
[mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg]

ROHS LIMIT 100 1000 1000 1000 1000

Pass result < 60 < 600 < 600 < 600 < 300

Inconclusive
60 – 150 600 – 1500 600 – 1500 > 600 > 300
result

Fail result > 150 > 1500 > 1500 - -

435 <30 <30 <30 <30 32457 Inconclusive

436 <30 9814** <30 <30 -- Inconclusive

437 <30 <30 <30 <30 -- Pass

Remark:
1. “<” denotes “less than”.
2. “mg/kg” denotes ”milligram per kilogram”.
3. With regard to the stoichiometry of Br in PBBs and PBDEs, the lower limit for Br is set at 300 mg/kg.
4. “--” means the substance for this sample are not tested.
5. “ ** ” means the result is exempted according to 2011/65/EU ANNEX item 6: Lead as an alloying element in
steel containing up to 0.35 % lead by weight, aluminum containing up to 0.4 % lead by weight and as a *
alloy containing up to 4 % lead by weight.
6. “ *** ” means the result is exempted according to 2011/65/EU ANNEX item 7(c)-I: Electrical and electronic
components containing lead in a glass or ceramic other than dielectric ceramic in capacitors.

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 144 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

3.2 Wet chemical test

Main instruments used for wet chemical test

Testing Target Instrument Method

Lead & Cadmium ICP-OES EN 62321-5:2014

Mercury ICP-OES EN 62321-4:2014


EN 62321-7-1:2015
Hexavalent Chromium UV-Vis
EN 62321-7-2:2017
PBBs & PBDEs GC/MS EN62321-6:2015

DEHP, BBP, DBP & DIBP GC/MS EN 62321-8:2017

Criteria of chemical test results

Pass:

A definite Pass is given If the chemical test result meets the requirements of RoHS.

Fail:

A definite Fail is given If the chemical test result exceeds the full respective RoHS limit.

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 145 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Test Cadmium Lead Mercury Chromium# PBBs PBDEs OVERALL


(VI) (Sum) (Sum)
Sample [mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg] RESULT
§
Limit 100 1000 1000 1000 1000

25 -- -- -- Negative -- -- Pass

30 -- -- -- Negative -- -- Pass

32 -- -- -- Negative -- -- Pass

39 -- -- -- Negative -- -- Pass

43 -- -- -- Negative -- -- Pass

45 -- -- -- Negative -- -- Pass

46 -- -- -- Negative -- -- Pass

49 -- -- -- Negative -- -- Pass

54 -- -- -- Negative -- -- Pass

55 -- -- -- Negative -- -- Pass

57 -- -- -- Negative -- -- Pass

63 -- -- -- Negative -- -- Pass

78 -- -- -- Negative -- -- Pass

87 -- -- -- Negative -- -- Pass

88 -- -- -- Negative -- -- Pass

99 -- -- -- Negative -- -- Pass

101 -- -- -- Negative -- -- Pass

102 -- -- -- Negative -- -- Pass


Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 146 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Test Cadmium Lead Mercury Chromium# PBBs PBDEs OVERALL


(VI) (Sum) (Sum)
Sample [mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg] RESULT
§
Limit 100 1000 1000 1000 1000

103 -- -- -- Negative -- -- Pass

107 -- -- -- Negative -- -- Pass

110 -- -- -- Negative -- -- Pass

111 -- -- -- Negative -- -- Pass

119 -- -- -- Negative -- -- Pass

129 -- -- -- Negative -- -- Pass

137 -- -- -- Negative -- -- Pass

142 -- -- -- Negative -- -- Pass

145 -- -- -- Negative -- -- Pass

158 -- -- -- Negative -- -- Pass

160 -- -- -- Negative -- -- Pass

183 -- -- -- Negative -- -- Pass

190 -- -- -- Negative -- -- Pass

211 -- -- -- Negative -- -- Pass

217 -- -- -- Negative -- -- Pass

218 -- -- -- Negative -- -- Pass

219 -- -- -- Negative -- -- Pass

222 -- -- -- Negative -- -- Pass

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 147 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Test Cadmium Lead Mercury Chromium# PBBs PBDEs OVERALL


(VI) (Sum) (Sum)
Sample [mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg] RESULT
§
Limit 100 1000 1000 1000 1000

225 -- -- -- Negative -- -- Pass

226 -- -- -- Negative -- -- Pass

283 -- -- -- Negative -- -- Pass

287 -- -- -- Negative -- -- Pass

288 -- -- -- Negative -- -- Pass

289 -- -- -- Negative -- -- Pass

290 -- -- -- Negative -- -- Pass

291 -- -- -- Negative -- -- Pass

292 -- -- -- Negative -- -- Pass

323 -- -- -- Negative -- -- Pass

333 -- -- -- Negative -- -- Pass

335 -- -- -- Negative -- -- Pass

337 -- -- -- Negative -- -- Pass

362 -- -- -- Negative -- -- Pass

386 -- -- -- Negative -- -- Pass

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 148 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Remark:
1. “ --” means the substance for this sample are not tested.
2. “mg/kg” denotes “milligram per kilogram”
3. “§“ The Chromium (VI) content in surface layer have been confirmed with reference to EN 62321-7-1:2015
Result Chromium (VI) concentration Qualitative result
The sample is negative for Cr(VI).
Negative <0.1µg/cm2 The Cr(VI) concentration is below the limit of quantification. The
coating is considered a non-Cr(VI) based coating.
The result is considered to be inconclusive. Unavoidable coating
variations may influence the determination. Recommendation: if
Inconclusive ≥0.1µg/cm2 and ≤0.13 µg/cm2 additional samples are available, perform a total of 3 trials to
increase sampling surface area. Use the averaged result of the 3
trails for the final determination.
The sample is positive for Cr(VI). Concentration is above the limit
Positive >0.13 µg/cm2 of quantification and the statistical margin of error. The sample
coating is considered to contain Cr(VI).

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 149 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Test Cadmium Lead Mercury Chromium PBBs PBDEs OVERALL


(VI) (Sum) (Sum)
Sample [mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg] RESULT

Limit 100 1000 1000 1000 1000 1000

06 -- -- -- -- <50 <50 Pass

90 -- -- -- -- <50 <50 Pass

105 -- -- -- -- <50 <50 Pass

108 -- -- -- -- <50 <50 Pass

113 -- -- -- -- <50 <50 Pass

115 -- -- -- -- <50 <50 Pass

135 -- -- -- -- <50 <50 Pass

138 -- -- -- -- <50 <50 Pass

155 -- -- -- -- <50 <50 Pass

176 -- -- -- -- <50 <50 Pass

177 -- -- -- -- <50 <50 Pass

180 -- -- -- -- <50 <50 Pass

193 -- 301404 -- -- -- -- Pass

213 -- -- -- -- <50 <50 Pass

229 -- -- -- -- <50 <50 Pass

230 -- -- -- -- <50 <50 Pass

238 -- -- -- -- <50 <50 Pass

269 -- -- -- -- <50 <50 Pass

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 150 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Test Cadmium Lead Mercury Chromium PBBs PBDEs OVERALL


(VI) (Sum) (Sum)
Sample [mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg] RESULT

Limit 100 1000 1000 1000 1000 1000

270 -- -- -- -- <50 <50 Pass

271 -- -- -- -- <50 <50 Pass

274 -- -- -- -- <50 <50 Pass

275 -- -- -- -- <50 <50 Pass

276 -- -- -- -- <50 <50 Pass

277 -- -- -- -- <50 <50 Pass

296 -- -- -- -- <50 <50 Pass

313 -- -- -- -- <50 <50 Pass

314 -- -- -- -- <50 <50 Pass

316 -- -- -- -- <50 <50 Pass

318 -- -- -- -- <50 <50 Pass

320 -- -- -- -- <50 <50 Pass

325 -- -- -- -- <50 <50 Pass

328 -- -- -- -- <50 <50 Pass

330 -- -- -- -- <50 <50 Pass

331 -- -- -- -- <50 <50 Pass

340 -- -- -- -- <50 <50 Pass

342 -- -- -- -- <50 <50 Pass

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 151 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Test Cadmium Lead Mercury Chromium PBBs PBDEs OVERALL


(VI) (Sum) (Sum)
Sample [mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg] RESULT

Limit 100 1000 1000 1000 1000 1000

358 -- -- -- -- <50 <50 Pass

360 -- -- -- -- <50 <50 Pass

362 -- -- -- <5 -- -- Pass

364 -- -- -- -- <50 <50 Pass

366 -- -- -- -- <50 <50 Pass

367 -- -- -- -- <50 <50 Pass

368 -- -- -- -- <50 <50 Pass

369 -- -- -- -- <50 <50 Pass

370 -- -- -- -- <50 <50 Pass

371 -- -- -- -- <50 <50 Pass

372 -- -- -- -- <50 <50 Pass

373 -- -- -- -- <50 <50 Pass

374 -- -- -- -- <50 <50 Pass

375 -- -- -- -- <50 <50 Pass

380 -- -- -- -- <50 <50 Pass

381 -- -- -- -- <50 <50 Pass

385 -- -- -- -- <50 <50 Pass

394 -- -- -- -- <50 <50 Pass

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 152 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Test Cadmium Lead Mercury Chromium PBBs PBDEs OVERALL


(VI) (Sum) (Sum)
Sample [mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg] [mg/kg] RESULT

Limit 100 1000 1000 1000 1000 1000

403 -- -- -- -- <50 <50 Pass

406 -- -- -- -- <50 <50 Pass

407 -- -- -- -- <50 <50 Pass

413 -- -- -- -- <50 <50 Pass

416 -- -- -- -- <50 <50 Pass

421 -- -- -- -- <50 <50 Pass

423 -- -- -- -- <50 <50 Pass

424 -- -- -- -- <50 <50 Pass

425 -- -- -- -- <50 <50 Pass

426 -- -- -- -- <50 <50 Pass

432 -- -- -- -- <50 <50 Pass

433 -- -- -- -- <50 <50 Pass

435 -- -- -- -- <50 <50 Pass

436 -- 658 -- -- -- -- Pass

Remark:
1. “<” denotes “less than”. (Detected limit of Cd :2mg/kg;Pb, Hg, and Cr(VI):5mg/kg; PBBs and PBDEs:
5mg/kg)
2. “mg/kg” denotes “milligram per kilogram”.
3. “ --” means the substance for this sample are not tested.
4. “ ** ” means the result is exempted according to 2011/65/EU ANNEX item 6(a,b,c): Lead as an alloying
element in steel containing up to 0.35 % lead by weight, aluminum containing up to 0.4 % lead by weight
and as a * alloy containing up to 4 % lead by weight.
Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 153 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Test DEHP DBP BBP DIBP


RESULT
Sample [mg/kg] [mg/kg] [mg/kg] [mg/kg]

Limit 1000 1000 1000 1000

01 <200 <200 <200 <200 Pass


02 <200 <200 <200 <200 Pass
03 <200 <200 <200 <200 Pass
04 <200 <200 <200 <200 Pass
06 <200 <200 <200 <200 Pass
09 <200 <200 <200 <200 Pass
10 <200 <200 <200 <200 Pass
11 <200 <200 <200 <200 Pass
12 <200 <200 <200 <200 Pass
13 <200 <200 <200 <200 Pass
15 <200 <200 <200 <200 Pass
16 <200 <200 <200 <200 Pass
17 <200 <200 <200 <200 Pass
18 <200 <200 <200 <200 Pass
19 <200 <200 <200 <200 Pass
20 <200 <200 <200 <200 Pass
22 <200 <200 <200 <200 Pass
23 <200 <200 <200 <200 Pass
24 <200 <200 <200 <200 Pass
26 <200 <200 <200 <200 Pass
27 <200 <200 <200 <200 Pass
28 <200 <200 <200 <200 Pass
29 <200 <200 <200 <200 Pass

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 154 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Test DEHP DBP BBP DIBP


RESULT
Sample [mg/kg] [mg/kg] [mg/kg] [mg/kg]

Limit 1000 1000 1000 1000

31 <200 <200 <200 <200 Pass


33 <200 <200 <200 <200 Pass
34 <200 <200 <200 <200 Pass
35 <200 <200 <200 <200 Pass
36 <200 <200 <200 <200 Pass
37 <200 <200 <200 <200 Pass
38 <200 <200 <200 <200 Pass
40 <200 <200 <200 <200 Pass
41 <200 <200 <200 <200 Pass
44 <200 <200 <200 <200 Pass
47 <200 <200 <200 <200 Pass
58 <200 <200 <200 <200 Pass
60 <200 <200 <200 <200 Pass
61 <200 <200 <200 <200 Pass
62 <200 <200 <200 <200 Pass
64 <200 <200 <200 <200 Pass
65 <200 <200 <200 <200 Pass
66 <200 <200 <200 <200 Pass
67 <200 <200 <200 <200 Pass
69 <200 <200 <200 <200 Pass
70 <200 <200 <200 <200 Pass
71 <200 <200 <200 <200 Pass
72 <200 <200 <200 <200 Pass

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 155 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Test DEHP DBP BBP DIBP


RESULT
Sample [mg/kg] [mg/kg] [mg/kg] [mg/kg]

Limit 1000 1000 1000 1000

73 <200 <200 <200 <200 Pass


74 <200 <200 <200 <200 Pass
75 <200 <200 <200 <200 Pass
76 <200 <200 <200 <200 Pass
77 <200 <200 <200 <200 Pass
79 <200 <200 <200 <200 Pass
81 <200 <200 <200 <200 Pass
82 <200 <200 <200 <200 Pass
83 <200 <200 <200 <200 Pass
84 <200 <200 <200 <200 Pass
85 <200 <200 <200 <200 Pass
86 <200 <200 <200 <200 Pass
89 <200 <200 <200 <200 Pass
90 <200 <200 <200 <200 Pass
91 <200 <200 <200 <200 Pass
92 <200 <200 <200 <200 Pass
93 <200 <200 <200 <200 Pass
94 <200 <200 <200 <200 Pass
95 <200 <200 <200 <200 Pass
96 <200 <200 <200 <200 Pass
97 <200 <200 <200 <200 Pass
98 <200 <200 <200 <200 Pass
100 <200 <200 <200 <200 Pass

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 156 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Test DEHP DBP BBP DIBP


RESULT
Sample [mg/kg] [mg/kg] [mg/kg] [mg/kg]

Limit 1000 1000 1000 1000

105 <200 <200 <200 <200 Pass


108 <200 <200 <200 <200 Pass
112 <200 <200 <200 <200 Pass
113 <200 <200 <200 <200 Pass
114 <200 <200 <200 <200 Pass
115 <200 <200 <200 <200 Pass
117 <200 <200 <200 <200 Pass
118 <200 <200 <200 <200 Pass
120 <200 <200 <200 <200 Pass
122 <200 <200 <200 <200 Pass
123 <200 <200 <200 <200 Pass
124 <200 <200 <200 <200 Pass
126 <200 <200 <200 <200 Pass
128 <200 <200 <200 <200 Pass
130 <200 <200 <200 <200 Pass
132 <200 <200 <200 <200 Pass
133 <200 <200 <200 <200 Pass
135 <200 <200 <200 <200 Pass
136 <200 <200 <200 <200 Pass
138 <200 <200 <200 <200 Pass
141 <200 <200 <200 <200 Pass
143 <200 <200 <200 <200 Pass
149 <200 <200 <200 <200 Pass

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 157 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Test DEHP DBP BBP DIBP


RESULT
Sample [mg/kg] [mg/kg] [mg/kg] [mg/kg]

Limit 1000 1000 1000 1000

151 <200 <200 <200 <200 Pass


152 <200 <200 <200 <200 Pass
153 <200 <200 <200 <200 Pass
154 <200 <200 <200 <200 Pass
155 <200 <200 <200 <200 Pass
159 <200 <200 <200 <200 Pass
162 <200 <200 <200 <200 Pass
163 <200 <200 <200 <200 Pass
164 <200 <200 <200 <200 Pass
165 <200 <200 <200 <200 Pass
166 <200 <200 <200 <200 Pass
169 <200 <200 <200 <200 Pass
171 <200 <200 <200 <200 Pass
172 <200 <200 <200 <200 Pass
175 <200 <200 <200 <200 Pass
176 <200 <200 <200 <200 Pass
177 <200 <200 <200 <200 Pass
178 <200 <200 <200 <200 Pass
179 <200 <200 <200 <200 Pass
180 <200 <200 <200 <200 Pass
181 <200 <200 <200 <200 Pass
182 <200 <200 <200 <200 Pass
184 <200 <200 <200 <200 Pass

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 158 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Test DEHP DBP BBP DIBP


RESULT
Sample [mg/kg] [mg/kg] [mg/kg] [mg/kg]

Limit 1000 1000 1000 1000

186 <200 <200 <200 <200 Pass


187 <200 <200 <200 <200 Pass
189 <200 <200 <200 <200 Pass
191 <200 <200 <200 <200 Pass
194 <200 <200 <200 <200 Pass
195 <200 <200 <200 <200 Pass
196 <200 <200 <200 <200 Pass
197 <200 <200 <200 <200 Pass
198 <200 <200 <200 <200 Pass
199 <200 <200 <200 <200 Pass
200 <200 <200 <200 <200 Pass
201 <200 <200 <200 <200 Pass
202 <200 <200 <200 <200 Pass
203 <200 <200 <200 <200 Pass
204 <200 <200 <200 <200 Pass
206 <200 <200 <200 <200 Pass
208 <200 <200 <200 <200 Pass
209 <200 <200 <200 <200 Pass
213 <200 <200 <200 <200 Pass
214 <200 <200 <200 <200 Pass
216 <200 <200 <200 <200 Pass
223 <200 <200 <200 <200 Pass
229 <200 <200 <200 <200 Pass

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 159 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Test DEHP DBP BBP DIBP


RESULT
Sample [mg/kg] [mg/kg] [mg/kg] [mg/kg]

Limit 1000 1000 1000 1000

230 <200 <200 <200 <200 Pass


232 <200 <200 <200 <200 Pass
234 <200 <200 <200 <200 Pass
235 <200 <200 <200 <200 Pass
236 <200 <200 <200 <200 Pass
238 <200 <200 <200 <200 Pass
239 <200 <200 <200 <200 Pass
240 <200 <200 <200 <200 Pass
241 <200 <200 <200 <200 Pass
242 <200 <200 <200 <200 Pass
244 <200 <200 <200 <200 Pass
245 <200 <200 <200 <200 Pass
246 <200 <200 <200 <200 Pass
248 <200 <200 <200 <200 Pass
251 <200 <200 <200 <200 Pass
252 <200 <200 <200 <200 Pass
253 <200 <200 <200 <200 Pass
254 <200 <200 <200 <200 Pass
255 <200 <200 <200 <200 Pass
256 <200 <200 <200 <200 Pass
257 <200 <200 <200 <200 Pass
258 <200 <200 <200 <200 Pass
259 <200 <200 <200 <200 Pass

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 160 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Test DEHP DBP BBP DIBP


RESULT
Sample [mg/kg] [mg/kg] [mg/kg] [mg/kg]

Limit 1000 1000 1000 1000

260 <200 <200 <200 <200 Pass


261 <200 <200 <200 <200 Pass
262 <200 <200 <200 <200 Pass
263 <200 <200 <200 <200 Pass
264 <200 <200 <200 <200 Pass
266 <200 <200 <200 <200 Pass
269 <200 <200 <200 <200 Pass
270 <200 <200 <200 <200 Pass
271 <200 <200 <200 <200 Pass
272 <200 <200 <200 <200 Pass
273 <200 <200 <200 <200 Pass
274 <200 <200 <200 <200 Pass
275 <200 <200 <200 <200 Pass
276 <200 <200 <200 <200 Pass
277 <200 <200 <200 <200 Pass
279 <200 <200 <200 <200 Pass
280 <200 <200 <200 <200 Pass
281 <200 <200 <200 <200 Pass
282 <200 <200 <200 <200 Pass
293 <200 <200 <200 <200 Pass
294 <200 <200 <200 <200 Pass
295 <200 <200 <200 <200 Pass
296 <200 <200 <200 <200 Pass

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 161 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Test DEHP DBP BBP DIBP


RESULT
Sample [mg/kg] [mg/kg] [mg/kg] [mg/kg]

Limit 1000 1000 1000 1000

297 <200 <200 <200 <200 Pass


298 <200 <200 <200 <200 Pass
299 <200 <200 <200 <200 Pass
300 <200 <200 <200 <200 Pass
301 <200 <200 <200 <200 Pass
302 <200 <200 <200 <200 Pass
303 <200 <200 <200 <200 Pass
304 <200 <200 <200 <200 Pass
305 <200 <200 <200 <200 Pass
306 <200 <200 <200 <200 Pass
307 <200 <200 <200 <200 Pass
310 <200 <200 <200 <200 Pass
311 <200 <200 <200 <200 Pass
312 <200 <200 <200 <200 Pass
313 <200 <200 <200 <200 Pass
314 <200 <200 <200 <200 Pass
316 <200 <200 <200 <200 Pass
318 <200 <200 <200 <200 Pass
320 <200 <200 <200 <200 Pass
325 <200 <200 <200 <200 Pass
328 <200 <200 <200 <200 Pass
330 <200 <200 <200 <200 Pass
331 <200 <200 <200 <200 Pass

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 162 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Test DEHP DBP BBP DIBP


RESULT
Sample [mg/kg] [mg/kg] [mg/kg] [mg/kg]

Limit 1000 1000 1000 1000

332 <200 <200 <200 <200 Pass


340 <200 <200 <200 <200 Pass
342 <200 <200 <200 <200 Pass
343 <200 <200 <200 <200 Pass
344 <200 <200 <200 <200 Pass
348 <200 <200 <200 <200 Pass
349 <200 <200 <200 <200 Pass
350 <200 <200 <200 <200 Pass
352 <200 <200 <200 <200 Pass
354 <200 <200 <200 <200 Pass
355 <200 <200 <200 <200 Pass
356 <200 <200 <200 <200 Pass
358 <200 <200 <200 <200 Pass
360 <200 <200 <200 <200 Pass
362 <200 <200 <200 <200 Pass
364 <200 <200 <200 <200 Pass
366 <200 <200 <200 <200 Pass
367 <200 <200 <200 <200 Pass
368 <200 <200 <200 <200 Pass
369 <200 <200 <200 <200 Pass
370 <200 <200 <200 <200 Pass
371 <200 <200 <200 <200 Pass
372 <200 <200 <200 <200 Pass

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 163 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Test DEHP DBP BBP DIBP


RESULT
Sample [mg/kg] [mg/kg] [mg/kg] [mg/kg]

Limit 1000 1000 1000 1000

373 <200 <200 <200 <200 Pass


374 <200 <200 <200 <200 Pass
375 <200 <200 <200 <200 Pass
378 <200 <200 <200 <200 Pass
379 <200 <200 <200 <200 Pass
380 <200 <200 <200 <200 Pass
381 <200 <200 <200 <200 Pass
382 <200 <200 <200 <200 Pass
383 <200 <200 <200 <200 Pass
384 <200 <200 <200 <200 Pass
385 <200 <200 <200 <200 Pass
388 <200 <200 <200 <200 Pass
389 <200 <200 <200 <200 Pass
390 <200 <200 <200 <200 Pass
392 <200 <200 <200 <200 Pass
394 <200 <200 <200 <200 Pass
397 <200 <200 <200 <200 Pass
402 <200 <200 <200 <200 Pass
403 <200 <200 <200 <200 Pass
406 <200 <200 <200 <200 Pass
407 <200 <200 <200 <200 Pass
408 <200 <200 <200 <200 Pass
409 <200 <200 <200 <200 Pass

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 164 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Test DEHP DBP BBP DIBP


RESULT
Sample [mg/kg] [mg/kg] [mg/kg] [mg/kg]

Limit 1000 1000 1000 1000

410 <200 <200 <200 <200 Pass


411 <200 <200 <200 <200 Pass
412 <200 <200 <200 <200 Pass
413 <200 <200 <200 <200 Pass
415 <200 <200 <200 <200 Pass
416 <200 <200 <200 <200 Pass
417 <200 <200 <200 <200 Pass
420 <200 <200 <200 <200 Pass
421 <200 <200 <200 <200 Pass
423 <200 <200 <200 <200 Pass
424 <200 <200 <200 <200 Pass
425 <200 <200 <200 <200 Pass
426 <200 <200 <200 <200 Pass
427 <200 <200 <200 <200 Pass
428 <200 <200 <200 <200 Pass
429 <200 <200 <200 <200 Pass
430 <200 <200 <200 <200 Pass
431 <200 <200 <200 <200 Pass
432 <200 <200 <200 <200 Pass
433 <200 <200 <200 <200 Pass
434 <200 <200 <200 <200 Pass
435 <200 <200 <200 <200 Pass

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 165 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Remark:
1. “<” denotes “less than”. (Detected limit: 200mg/kg)
2. “mg/kg” denotes “milligram per kilogram”.
3. DEHP = Di-(2-ethyl-hexyl)phthalate, DBP = Di-butyl phthalate
BBP = Butyl-benzyl phthalate, DIBP = Di-iso-butyl phthalate

TÜV SÜD Certification and Testing (China) Co., Ltd.

Prepared by: Checked by:

Mr. Yiwei CHEN Mr. Feng ZHANG

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 166 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

APPENDIX I: Product Model

Product: Washing machine Test model: MFK120-U1401B/C14E-EU(A33),


MFK100-U1501B/C14E-EU(A33), MFK90-S1401B/C14E-EU(A32),
MFK80-U1401B/C14E-EU(A32), MFK70-S1401B/C14E-EU(A31),
MFK80-S1401B/C14E-EU(A31)

Additional Model : MFN90-S1203/C31E-EU(NE), MFK60-JS1223B/C19EPV-EU(NB),


MFK70-S1423B/C19EPV-EU(NB), MFK80-S1423BI/C19EPV-EU(NB), MFK60-JS1223B/C19EP-EU(NB),
MFK80-S1423B/C19EP-EU(NB), MFK80-U1423BI/C19EPV-EU(NB), MFK90-S1423B/C19EP-EU(NB),
MFK80-U1423B/C19EPV-EU(NB), MFK70-S1423/C19E-EU(NE), MFK80-DU1423B/C19EP-EU(NE),
MFK80-S1401BI/C14E-EU(NB), MFK90-S1401BI/C14E-EU(NB), MFK90-S1403B/C14E-EU(NB),
MFK80-DU1423B/C19EP-EU(NE), MFE60-JU1210/C31-EU(ND), MFE60-JU1212/C31E-EU(ND),
MFE70-U1210/C31-EU(ND), MFE70-U1212/C31E-EU(ND), MFK70-S1423/C19E-EU(NE),
MFK80-DU1423B/C19EP-EU(NE), MFN70-U1223/C31E-EU(NE), MFN60-JU1223/C31E-EU(NE),
MFN60-U1023/C31E-EU(NE), MFN80-S1423/C31E-EU(NE), MFK70-S1223B/C19EP-EU(NB),
MFK80-DU1403B/C14E-EUFB(NE), MFK80-S1401BI/C14E-EU(NB), MFE70-U1206/C31-EU(A2)-MD,
MFE70-U1208/C31E-EU(A2), MFK80-DU1401B/C14E-EU(NE), MFK100-DU1501B/C25E-EU(ND),
MFK70-S1401B/C14E-EU(NB), MFK80-S1401B/C14E-EU(NB), MFK80-U1401B/C14E-EU(NB),
MFK90-S1401B/C14E-EU(NB), MFK100-U1501B/C14E-EU(NB), MFK80-DU1401B/C14E-EU(NE),
MFK100-DU1501B/C25E-EU(ND)

Remark:
1. The report covers material testing on specified samples.
2. The tested materials covered by the report were declared by the manufacturer to be used on the additional
model.

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 167 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

APPENDIX II: Official Exemption Items

Below items are quoted based on Directives of 2011/65/EU and its valid Amending Directives.

Exemption Scope and dates of applicability

Mercury in single capped (compact) fluorescent lamps not


1
exceeding (per burner)
Expires on 31 December 2011; 3,5mg
maybe used per burner after 31 December
1(a) For general lighting purpose< 30 W:5mg
2011 until 31 December 2012; 2.5mg shall
be used per burner after 31 December 2012
Expires on 31 December 2011; 3,5mg
maybe used per burner after 31 December
1(b) For general lighting purposes ≥ 30 W and < 50 W:5mg
2011 until 31 December 2012; 2.5mg shall
be used per burner after 31 December 2012

1(c) For general lighting purposes ≥ 50 W and < 150 W:5mg

1(d) For general lighting purpose ≥ 30 W and ≥ 150 W:15mg

No limitation of use until 31 December 2011;


For general lighting purpose with circular or square structural
1(e) 7 mg may be used per burner after 31
shape san tube diameter <17mm
December 2011

1(f) For special purposes:5mg

Mercury in double capped linear fluorescent lamps for general


2(a)
lighting purposes not exceeding (per lamp)

Tri-band phosphor with normal lifetime and a tube diameter < 9 Expires on 31 December 2011; 4mg may be
2(a)(1)
mm (e.g. T2): 5mg used per lamp after 31 December 2011

Tri-band phosphor with normal lifetime and a tube diameter ≥ 9 Expires on 31 December 2011; 3mg may be
2(a)(2)
mm and ≤ 17mm (e.g. T5): 5mg used per lamp after 31 December 2011

Tri-band phosphor with normal lifetime and a tube diameter >17 Expires on 31 December 2011; 3,5 mg may
2(a)(3)
mm and ≤ 28mm (e.g. T8): 5mg be used per lamp after 31 December 2011

Tri-band phosphor with normal lifetime and a tube diameter Expires on 31 December 2011; 3,5 mg may
2(a)(4)
>28mm (e.g. T12): 5mg be used per lamp after 31 December 2011

Expires on 13 December 2011;5mg may be


2(a)(5) Tri-band phosphor with long lifetime(≥25 000h):8mg
used per lamp after 31 December 2011

Mercury in other fluorescent lamps not exceeding


2(b)
(per lamp):

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 168 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Exemption Scope and dates of applicability

Linear halophosphate lamps with tube >28 mm(e.g.T10 and T12):


2(b)(1) Expires on 13 April 2012
10mg

2(b)(2) Non-linear halophosphate lamps (all diameters):15mg Expires on 13 April 2016

No limitation of use until 31 December 2011;


Non-linear tri-band phosphor lamps with tube diameter >17mm
2(b)(3) 15 mg may be used per lamp after 31
(e.g. T9)
December 2011
No limitation of use until 31 December 2011;
Lamps for other general lighting and special purposes (e.g.
2(b)(4) 15 mg may be used per lamp after 31
induction lamps)
December 2011
Mercury in cold cathode fluorescent lamps and external electrode
3 fluorescent lamps (CCFL and EEFL) for special purposes not
exceeding (per lamp)
No limitation of use until 31 December 2011;
3(a) Short length(≤500mm) 3,5 mg may be used per lamp after 31
December 2011
No limitation of use until 31 December 2011;
3(b) Medium length (> 500mm and ≤ 1 500mm) 5 mg may be used per lamp after 31
December 2011
No limitation of use until 31 December 2011;
3(c) Long length (> 1 500mm) 13 mg may be used per lamp after 31
December 2011
No limitation of use until 31 December 2011;
4(a) Mercury in other low pressure discharge lamps (per lamp) 15 mg may be used per lamp after 31
December 2011
Mercury in High Pressure Sodium (vapour) lamps for general
4(b) lighting purposes not exceeding (per burner) in lamps with
improved colour rendering index Ra >60;
No limitation of use until 31 December 2011;
4(b)-I P≤155 W 30mg may be used per burner after 31
December 2011
No limitation of use until 31 December 2011;
4(b)-II 155 W < P ≤ 405 W 40mg may be used per burner after 31
December 2011
No limitation of use until 31 December 2011;
4(b)-III P > 405 W 40mg may be used per burner after 31
December 2011
Mercury in other High Pressure Sodium (vapour) lamps for
4(c)
general lighting purposes not exceeding (per burner)
No limitation of use until 31 December 2011;
30mg may be used per burner after 31
4(c)-I P≤155 W
December 2011

No limitation of use until 31 December 2011;


4(c)-II 155 W < P ≤ 405 W 40mg may be used per burner after 31
December 2011

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 169 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Exemption Scope and dates of applicability

No limitation of use until 31 December 2011;


4(c)-III P > 405 W 40mg may be used per burner after 31
December 2011

4(d) Mercury in High Pressure Mercury (vapour) lamps (HPMV) Expires on 13 April 2015

4(e) Mercury in metal halide lamps (MH)

Mercury in other discharge lamps for special purposes not


4(f)
specifically mentioned in this Annex
Mercury in hand crafted luminous discharge tubes used for signs,
decorative or architectural and specialist lighting and light-
artwork, where the mercury content shall be limited as follows:
(a) 20 mg per electrode pair + 0,3 mg per tube length in cm,
4(g) but not more than 80 mg, for outdoor applications and Expires on 1 December 2018
indoor applications exposed to temperatures below 20 °C;
(b) 15 mg per electrode pair + 0,24 mg per tube length in cm,
but not more than 80 mg, for all other indoor applications.

5(a) Lead in glass of cathode ray tubes

5(b) Lead in glass of fluorescent tubes not exceeding 0,2 % by weight

Expires on:
— 21 July 2021 for categories 8 and 9 other
than in vitro diagnostic medical devices and
industrial
Lead as an alloying element in steel for machining purposes and monitoring and control instruments;
6(a)
in galvanised steel containing up to 0,35 % lead by weight — 21 July 2023 for category 8 in vitro
diagnostic medical devices;
— 21 July 2024 for category 9 industrial
monitoring and control instruments, and for
category 11.
Lead as an alloying element in steel for machining purposes
containing up to 0,35 % lead by weight and in batch hot dip Expires on 21 July 2021 for categories 1-7
6(a)-I
galvanised steel components containing up to 0,2 % lead by and 10.’
weight
Expires on:
— 21 July 2021 for categories 8 and 9 other
than in vitro diagnostic medical devices and
industrial monitoring and control
Lead as an alloying element in aluminium containing up to 0,4 %
6(b) instruments,
lead by weight
— 21 July 2023 for category 8 in vitro
diagnostic medical devices,
— 21 July 2024 for category 9 industrial
monitoring and control instruments, and for

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 170 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Exemption Scope and dates of applicability

category 11.

Lead as an alloying element in aluminium containing up to 0,4 %


Expires on 21 July 2021 for categories 1-7
6(b)-I lead by weight, provided it stems from
and 10.
lead-bearing aluminium scrap recycling
Lead as an alloying element in aluminium for machining purposes Expires on 18 May 2021 for categories 1-7
6(b)-II
with a lead content up to 0,4 % by weight and 10.’
Expires on:
— 21 July 2021 for categories 1-7 and 10,
— 21 July 2021 for categories 8 and 9 other
than in vitro diag-nostic medical devices and
industrial monitoring and control
6(c) Copper alloy containing up to 4 % lead by weight instruments,
— 21 July 2023 for category 8 in vitro
diagnostic medical de-vices,
— 21 July 2024 for category 9 industrial
monitoring and control instruments, and for
category 11.’
Applies to categories 1-7 and 10 (except
applications covered by point 24 of this
Annex) and expires on 21 July 2021.
For categories 8 and 9 other than in vitro
diagnostic medical de-vices and industrial
Lead in high melting temperature type
monitoring and control instruments expires
7(a) solders (i.e. lead-based alloys containing
on 21 July 2021.
85 % by weight or more lead)
For category 8 in vitro diagnostic medical
devices expires on 21 July 2023.
For category 9 industrial monitoring and
control instruments, and for category 11
expires on 21 July 2024.’
Lead in solders for servers, storage and storage array systems,
7(b) network infrastructure equipment for switching, signalling,
transmission, and network management for telecommunications
Applies to categories 1-7 and 10 (except
applications covered under point 34) and
expires on 21 July 2021.
For categories 8 and 9 other than in vitro
Electrical and electronic components containing lead in a glass or diagnostic medical devices and industrial
ceramic other than dielectric ceramic in capacitors, e.g. monitoring and control instruments expires
7(c)-I
piezoelectronic devices, or in a glass or ceramic matrix on 21 July 2021.
compound For category 8 in vitro diagnostic medical
devices expires on 21 July 2023.
For category 9 industrial monitoring and
control instruments, and for category 11
expires on 21 July 2024.
Lead in dielectric ceramic in capacitors for a rated voltage of 125
7(c)-II
V AC or 250 V DC or higher

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 171 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Exemption Scope and dates of applicability

Expires on 1 January 2013 and after that


Lead in dielectric ceramic in capacitors for a rated voltage of less date may be used in spare parts for EEE
7(c)-III
than 125 V AC or 250 V DC placed on the market before 1 January 2013

Lead in PZT based dielectric ceramic materials for capacitors


7(c)-IV
being part of integrated circuits or discrete semiconductors’
Expires on 1 January 2012 and after that
Cadmium and its compounds in one shot pellet type thermal cut-
8(a) date may be used in spare parts for EEE
offs
placed on the market before 1 January 2012

8(b) Cadmium and its compounds in electrical contacts

Hexavalent chromium as an anticorrosion agent of the carbon


9 steel cooling system in absorption refrigerators up to 0,75 % by
weight in the cooling solution
Lead in bearing shells and bushes for refrigerant-containing
9(b) compressors for heating, ventilation, air conditioning and
refrigeration (HVACR) applications
May be used in spare parts for EEE placed
11(a) Lead used in C-press compliant pin connector systems
on the market before 24 September 2010
Expires on 1 January 2013 and after that
11(b) Lead used in other than C-press compliant pin connector systems date may be used in spare parts for EEE
placed on the market before 1 January 2013
Lead as a coating material for the thermal conduction module C- May be used in spare parts for EEE placed
12
ring on the market before 24 September 2010

13(a) Lead in white glasses used for optical applications

Cadmium and lead in filter glasses and glasses used for


13(b)
reflectance standards
Lead in solders consisting of more than two elements for the
Expires on 1 January 2011 and after that
connection between the pins and the package of microprocessors
14 date may be used in spare parts for EEE
with a lead content of more than 80 % and less than 85 % by
placed on the market before 1 January 2011
weight
Lead in solders to complete a viable electrical connection
15 between semiconductor die and carrier within integrated circuit
flip chip packages

16 Lead in linear incandescent lamps with silicate coated tubes Expires on 1 September 2013

Lead halide as radiant agent in high intensity discharge (HID)


17
lamps used for professional reprography applications

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 172 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Exemption Scope and dates of applicability

Lead as activator in the fluorescent powder (1 % lead by weight


or less) of discharge lamps when used as speciality lamps for
18(a) diazoprinting reprography, lithography, insect traps, Expires on 1 January 2011
photochemical and curing processes containing phosphors such
as SMS ((Sr,Ba)2MgSi2O7:Pb)
Categories 1-7 and 10, Expires on 21 July
2021
Categories 8 and 9 other than in vitro
diagnostic medical devices and industrial
Lead as activator in the fluorescent powder (1 % lead by weight monitoring and control instruments, Expires
18(b) or less) of discharge lamps when used as sun tanning lamps on 21 July 2021
containing phosphors such as BSP(BaSi 2O5 :Pb) Category 8 in vitro diagnostic medical
devices, Expires on 21 July 2023
Category 9 industrial monitoring and control
instruments, and for category 11, Expires on
21 July 2024
Lead as activator in the fluorescent powder (1 % lead by weight Categories 5 and 8, excluding applications
18(b)-I or less) of discharge lamps containing phosphors such as BSP covered by entry 34 of Annex IV, Expires on
(BaSi2O5:Pb) when used in medical phototherapy equipment 21 July 2021
Lead with PbBiSn-Hg and PbInSn-Hg in specific compositions as
19 main amalgam and with PbSn-Hg as auxiliary amalgam in very Expires on 1 June 2011
compact energy saving lamps (ESL)
Lead oxide in glass used for bonding front and rear substrates of
20 Expires on 1 June 2011
flat fluorescent lamps used for Liquid Crystal Displays (LCDs)

Lead and cadmium in printing inks for the application of enamels


21
on glasses, such as borosilicate and soda lime glasses

Lead in finishes of fine pitch components other than connectors May be used in spare parts for EEE placed
23
with a pitch of 0,65 mm and less on the market before 24 September 2010
Expires on:
— 21 July 2021 for categories 1-7 and 10,
— 21 July 2021 for categories 8 and 9 other
than in vitro diagnostic medical devices and
industrial moni-toring and control
Lead in solders for the soldering to machined through hole
24 instruments,
discoidal and planar array ceramic multilayer capacitors
— 21 July 2023 for category 8 in vitro
diagnostic med-ical devices,
— 21 July 2024 for category 9 industrial
monitoring and control instruments, and for
category 11.’
Lead oxide in surface conduction electron emitter displays (SED)
25
used in structural elements, notably in the seal frit and frit ring

26 Lead oxide in the glass envelope of black light blue lamps Expires on 1 June 2011

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 173 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Exemption Scope and dates of applicability

Lead alloys as solder for transducers used in high-powered


Expired on 24 September 2010
27 (designated to operate for several hours at acoustic power levels
of 125 dB SPL and above) loudspeakers
Lead bound in crystal glass as defined in Annex I (Categories 1,
29
2, 3 and 4) of Council Directive 69/493/EEC ( 1 )
Cadmium alloys as electrical/mechanical solder joints to electrical
conductors located directly on the voice coil in transducers used
30
in high-powered loudspeakers with sound pressure levels of 100
dB (A) and more
Lead in soldering materials in mercury free flat fluorescent lamps
31 (which e.g. are used for liquid crystal displays, design or industrial
lighting)
Lead oxide in seal frit used for making window assemblies for
32
Argon and Krypton laser tubes

Lead in solders for the soldering of thin copper wires of 100 um


33
diameter and less in power transformers
Applies to all categories; expires on:
— 21 July 2021 for categories 1-7 and 10,
— 21 July 2021 for categories 8 and 9 other
than in vitro diag-nostic medical devices and
industrial monitoring and control
34 Lead in cermet-based trimmer potentiometer elements instruments,
— 21 July 2023 for category 8 in vitro
diagnostic medical de-vices,
— 21 July 2024 for category 9 industrial
monitoring and control instruments, and for
category 11.’
Mercury used as a cathode sputtering inhibitor in DC plasma
36 Expired on 1 July 2010
displays with a content up to 30 mg per display

Lead in the plating layer of high voltage diodes on the basis of a


37
zinc borate glass body

Cadmium and cadmium oxide in thick film pastes used on


38
aluminium bonded beryllium oxide
Cadmium selenide in downshifting cadmium-based
Expires for all categories on [two years after
semiconductor nanocrystal quantum dots for use in
39(a) the publication of the Delegated Directive in
display lighting applications (< 0,2 μg Cd per mm2
the Official Journal]
of display screen area)
Cadmium in photoresistors for analogue optocouplers applied in
40 Expires on 31 December 2013
professional audio equipment
Lead in solders and termination finishes of electrical and
electronic components and finishes of printed circuit boards used
41 Expires on 1 December 2018
in ignition modules and other electrical and electronic engine
control systems, which for technical reasons must be mounted
Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 174 of 175
Report No. 48.400.19.7469.00-22/01
Dated 2021-05-26

Exemption Scope and dates of applicability

directly on or in the crankcase or cylinder of hand-held


combustion engines (classes SH:1, SH:2, SH:3 of Directive
97/68/EC of the European Parliament and of the Council.

Lead in bearings and bushes of diesel or gaseous fuel powered


internal combustion engines applied in non-road professional use
equipment:

with engine total displacement ≥ 15 litres; or


Category 11, excluding applications covered
with engine total displacement < 15 litres and the engine is
42 by entry 6(c) of Annex III, Expires on 21 July
designed to operate in applications where the time between
2024
signal to start and full load is required to be less than 10 seconds;
or regular maintenance is typically performed in a harsh and dirty
outdoor environment, such as mining, construction, and
agriculture applications.

Bis(2-ethylhexyl) phthalate in rubber components in engine


systems,
designed for use in equipment that is not intended solely for
consumer
use and provided that no plasticised material comes into contact
with
human mucous membranes or into prolonged contact with human
skin
and the concentration value of bis(2-ethylhexyl) phthalate does
not exceed:
(a) 30 % by weight of the rubber for
(i) gasket coatings; Applies to category 11 and expires on
43 (ii) solid-rubber gaskets; or 21 July 2024.
(iii) rubber components included in assemblies of at least three
components using electrical, mechanical or hydraulic energy to
do work, and attached to the engine.
(b) 10 % by weight of the rubber for rubber-containing
components not
referred to in point (a).
For the purposes of this entry, “prolonged contact with human
skin” means
continuous contact of more than 10 minutes duration or
intermittent
contact over a period of 30 minutes, per day.

Lead in solder of sensors, actuators, and engine control units of


combustion engines within the scope of Regulation (EU)
2016/1628 of the European Parliament and of the Council (*1), Applies to category 11 and expires on 21
44 installed in equipment used at fixed positions while in operation July 2024.
which is designed for professionals, but also used by non-
professional users

--END OF REPORT--

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of
the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing
and certification regulation, chapter A-3.4.

Disclaimer Measurement Uncertainty:


Unless otherwise agreed upon, Pass or Fail verdicts are given base on the measured values without any considerations of measurement uncertainties.
Please note, every test method has a measurement uncertainty which has been evaluated by the laboratory according to ISO/IEC 17025 requirements.
By taking measurement uncertainties into account it might happen that measured values can neither be assessed as Pass nor as Fail.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Chemical Lab
10 Huaxia Road(M), Dongting, Wuxi No.1999 Duhui Road
Jiangsu, 214100, P. R. China Shanghai City

Tel.: +86-510-88203737 Tel.: +86-21-60376368


Fax: +86-510-88203636
www.tuv-sud.cn
[email protected] Page 175 of 175

You might also like