DECU 5
DECU 5
1. PROVISIONING
The provisions for this task are given in paragraph A. and in the tasks of paragraph B.
Standard tools
Printed on Jul 09/2024 from C 298 N7 460 9 IETP, dated Aug 30/2023.
Not applicable
Special tools
Not applicable
Systematic spares
Not applicable
Spares
Not applicable
Consumables
Not applicable
B. Additional pre-requisites
2. TASKS/REFERENCE DOCUMENTS
3. PROCEDURE
A. Preliminary procedures
Effectivity: ALL
Special procedure
Page 201
The information in this manual is subject to the warning
given on the information page. 73-22-04-280-804-A01 Aug. 30/2023
SAFRAN HELICOPTER ENGINES
– Apply the task hardware installation with polybox unit and its tool software launch special
procedure (Refer to Task 73-22-04-280-801).
NOTE: You can read and save in real time the normal message transmitted by the
DECU on the serial link. In case of interruption during the procedure, refer to
paragraph 5.
(1) Set the harness box switches according to the table on the Task 73-22-04-280-801
Paragraph 3.E
(2) Click on the "Inter-EECU message - ARINC 429" button.
NOTE: The maintenance software displays the "Inter-EECU message - ARINC 429"
Printed on Jul 09/2024 from C 298 N7 460 9 IETP, dated Aug 30/2023.
NOTE: If you start the application without unticking “Other EECU”, the reception
of parameters will be considered “Bad” and the application will be
blocked without any chance of exiting the maintenance software.
Start the task manager to exit the maintenance software if the application is blocked
(a) Press on “Ctrl/Alt/del”
(b) Select “Task manager”.
(c) Select “TL0178P101” and click on “End task”.
(d) Restart the procedure.
(4) Click on the “Start” button shown as a green light icon, to start the process.
(a) Perform the following procedure if the parameters are not received, (Receipt: Bad” is
displayed in red ).
Effectivity: ALL
Special procedure
Page 202
The information in this manual is subject to the warning
given on the information page. 73-22-04-280-804-A01 Aug. 30/2023
SAFRAN HELICOPTER ENGINES
NOTE: The value of each parameter is displayed in the white fields. The label
number, the unit and the designation of each parameter are indicated to the
left of each white field.
(6) Saving of data sent by the DECU
(a) Click on the " Save " button. This action initiates the save and the action button
becomes " Stop Save "
(b) Click on the " Stop save " button to stop the save. This action allows a sequence to be
saved.
database reference, the DECU serial number, the date and the time of
the save.
The file extension will be noted " int ".
(7) Opening a saved file
(a) Click on the " Stop " button if parameters are currently being received.
(b) Click on the " Open " button represented by a folder.
NOTE: The maintenance software displays a " File to be opened " window
and selects by default the directory in which the files are saved.
The operator can select another directory and/or select a file in the
selected list.
(c) Having selected a file, click " Open " to display on the screen the data stored in the
file.
NOTE: The first screen may be displayed in red as the file is positioned at
the top and no value is available.
(d) When the " File " tab becomes available, the following actions are possible:
– To stop the process, click on the " Stop " button represented by a red light icon.
– The " Start ", " Open " and " Exit " action buttons become active again.
(9) Quit the " Inter-ECU message - ARINC 429 " module.
– Click on the " Exit " button. The maintenance software returns to the main menu.
(10) Quit the maintenance software.
Effectivity: ALL
Special procedure
Page 203
The information in this manual is subject to the warning
given on the information page. 73-22-04-280-804-A01 Aug. 30/2023
SAFRAN HELICOPTER ENGINES
C. Final steps
E. Additional procedures
Not applicable
Effectivity: ALL
Special procedure
Page 204
The information in this manual is subject to the warning
given on the information page. 73-22-04-280-804-A01 Aug. 30/2023