OSRAM LM 80
OSRAM LM 80
com
Light is OSRAM
DURIS ® E 2835
White (CCT 2200 K – 6500 K)
TABLE OF CONTENTS
1 - General Information ................................................................................................................................. 3
1.1 Description of LED Light Sources ................................................................................................... 3
1.2 Standards Used: ............................................................................................................................. 3
1.3 Testing Equipment .......................................................................................................................... 3
1.4 Drive Level ...................................................................................................................................... 3
1.5 Ambient Conditions for Maintenance Test ...................................................................................... 4
1.6 Photometric Measurement Method and Uncertainty....................................................................... 4
1.7 Statement of Traceability ................................................................................................................ 4
1.8 Sample Set ...................................................................................................................................... 5
1 - General Information
ANSI/IES LM-80-15: IES Approved Method for Measuring Lumen Maintenance of LED Light Sources.
CIE 127:2007: Measurement of LEDs (This standard was not accredited by IAS)
ENERGY STAR® Requirements for the Use of LM-80 Data (This standard was not accredited by IAS)
Integrating sphere and spectroradiometer is used to measure luminous flux and chromaticity coordinate u’v’. 2π measurement was
used and sample was drived by DC power supply. The forward current was regulated to within ±0.5% of the nominal value. The test
system was calibrated by halogen reference lamp. The ambient temperature during test was set to 25°C ± 2°C, RH <65%. The
temperature measurement point was located in the sphere and the temperature was detected by a temperature probe.
The uncertainty of the light output measurements is U=1.59% (K=2), at the 95% confidence level. The uncertainty of the correlated
color temperature measurements is U=21K (K=2), at the 95% confidence level.
The uncertainty of the temperature is U=0.8671°C (K=2), at the 95% confidence level.
Number of Units: 30
Number of Units: 30
Number of Units: 30
Data Set: 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs 7000hrs 8000hrs 9000hrs 10000hrs
1 100.16% 99.97% 99.78% 99.51% 99.09% 98.68% 98.29% 97.96% 97.78% 97.56%
2 100.03% 99.83% 99.61% 99.29% 98.82% 98.33% 97.90% 97.51% 97.23% 96.97%
3 99.91% 99.64% 99.39% 99.02% 98.42% 97.84% 97.40% 96.98% 96.65% 96.34%
Data Set: 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs 7000hrs 8000hrs 9000hrs 10000hrs
1 0.0003 0.0005 0.0008 0.0011 0.0014 0.0017 0.0018 0.0021 0.0022 0.0024
2 0.0004 0.0007 0.001 0.0013 0.0015 0.0018 0.0020 0.0023 0.0024 0.0026
3 0.0006 0.0009 0.0012 0.0016 0.0019 0.0021 0.0022 0.0023 0.0025 0.0027
110% 0.0040
105% 0.0035
95% 0.0025
90% 0.0020
85% 0.0015
80% 0.0010
75% 0.0005
70% 0.0000
0 3000 6000 9000 12000 15000
Time (hours)
3 - Test Data
3.1 Data Set 1, 55°C, 150mA (Lumen Maintenance)
4 - DUT Photo
4.1 Mechanical Dimensions
TMPLED
***********END OF REPORT***********
Appendix A:
Energy Star® LM-80 Application
DUT Identification
DUT manufacturer’s name OSRAM Opto Semiconductors (Malaysia) Sdn. Bhd.
DUT Characteristics
Total input power (W) 0.46
Distribution of part or all of the contents of this Document to any 3rd party in any form without the
prior permission of OSRAM Opto Semiconductors GmbH is prohibited except in accordance with
applicable mandatory law.
IES TM-21-11 Projection 180304W5
Appendix B:
Lumen Maintenance Projection (IES TM-21-11)
For Information Only!
1. General Information
Description of LED light source tested DURIS® E 2835 GW JTLPS1.EM
2. Projection Data
I II III
3. Graphic chart
110
100
Lumen Maintenance (%)
90
80
55 °C / 150 mA
70 85 °C / 150 mA
105 °C / 150 mA
TM-21 for 55°C
60 TM-21 for 85°C
TM-21 for 105°C
L70 EoL
50
1,000 10,000 100,000
Time (h)
Distribution of part or all of the contents of this Document to any 3rd party in any form without the
prior permission of OSRAM Opto Semiconductors GmbH is prohibited except in accordance with
applicable mandatory law.
Additional Models Covered By Testing 180304W5
Appendix C:
Additional Models Covered By Testing
The 28 September 2017 ENERGY STAR® Requirements for the Use of LM-80 Data defines
conditons for which a LM‐80 report is applied to cover models that have not been directly tested.
The test results in this report applies to the following list of models:
Distribution of part or all of the contents of this Document to any 3rd party in any form without the
prior permission of OSRAM Opto Semiconductors GmbH is prohibited except in accordance with
applicable mandatory law.
IES LM-80-15 Test Report
Disclaimer
Please carefully read the below terms and conditions before using the Information.
If you do not agree with any of these terms and conditions, do not use the Informatio n.
The Information contained in this document does not constitute an independent warranty. The committed
behavior is described in the Product data sheet.
Further explanations:
Data: The Data used in this Document consider the reliability test results under the mentioned driving
conditions only. For Product information on the maximum operating conditions please refer to the Product
data sheet or contact your local sales partner.
Conditions: The conditions for the generation of the data are as follows:
1. The Data and curves shown in this Document are based on experiments carried out under laboratory
conditions on a random sample size of LED with readouts at discrete readout times (where applicable).
Thus, the Data above represent a limited number of production lots only and may differ between different
assembly lots over time (including chip or package changes). Thus, the behavior of the LED in the final
application may differ from the Data. The behavior of the LED at conditions or readout times deviating from
those stated above may not be deduced from the Data.
2. For long term operation additional failure modes of the chip or package can occur which are not shown in
this Document.
3. Possible differences in the thermal management of OSRAM OS and customer’s setup may lead to a
different aging behavior.
4. The lifetime projection data presented in this Document has been evaluated in accordance with the
lifetime extrapolation method described and defined in IES TM-21-11. The lifetime projection is based on the
Data shown in this Document. The Data had been collected and assembled according to IES LM-80-15.
Distribution of part or all of the contents of this Document to any 3rd party in any form without the
prior permission of OSRAM Opto Semiconductors GmbH is prohibited except in accordance with
applicable mandatory law.
END OF DOCUMENT