0% found this document useful (0 votes)
2 views

ee loads

The document outlines the design process for a two-storey reinforced-concrete residential structure using STAAD.Pro and STAAD Advanced Concrete Designer. Key objectives include calculating wind pressure, designing roof trusses, deriving load values, and incorporating seismic parameters. It provides detailed specifications for structural elements, load calculations, and compliance with NSCP and UBC standards.

Uploaded by

johncarlolaud285
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2 views

ee loads

The document outlines the design process for a two-storey reinforced-concrete residential structure using STAAD.Pro and STAAD Advanced Concrete Designer. Key objectives include calculating wind pressure, designing roof trusses, deriving load values, and incorporating seismic parameters. It provides detailed specifications for structural elements, load calculations, and compliance with NSCP and UBC standards.

Uploaded by

johncarlolaud285
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 46

DESIGN OF

TWO-STOREY REINFORCED-CONCRETE RESIDENTIAL STRUCTURE


STAAD.Pro & STAAD Advanced Concrete Designer

Main objectives
1) Calculate Wind Pressure for Components and Cladding per NSCP
2) Design the Roof Truss and Purlins per NSCP 2015/AISC 360-10 by
3) Derive dead load and live load values per NSCP 2015
4) Discuss NSCP 2015/UBC 97 Seismic parameters input to STAAD
5) Design the concrete elements in STAAD Advanced Concrete Desig
(beams, slabs, columns and footings)
E RESIDENTIAL STRUCTURE USING
ed Concrete Designer RCDC

nts and Cladding per NSCP 2015/ASCE 7-10


NSCP 2015/AISC 360-10 by LRFD Method
per NSCP 2015
rameters input to STAAD
D Advanced Concrete Designer RCDC
Purlin spacing 0.8 m
truss spacing 2.5 m

STORIES (LEVELS)

Levels Storey Height (m)

Footing to GF 1.8
GF to 2F 3
2F - Roof Beam 3
Roof Beam - Apex 2
9.8
Roof mean Height for wind load calculation
7.00 m
Roof Slope = 22.62deg
nd load calculation
cvcvcccccc
Seismic Source Type A
CAGAYAN DE ORO

v
Na=1
Nv=1
Bulacan = 250
kph
STORIES (LEVELS)
Levels Storey Height (m)
Footing to GF 1.5
GF to 2nd 3.6
2nd-9th Floor 3.3
Roof Beam - Apex 0
32.5

PROPERTIES
Beams Columns Slabs fc' fy
RB750X650 RC850X850 S200 20.68 Mpa 275 Mpa
RB700X650 RC890X890 S150 (3000psi) (Gr40)

LOADS
Dead Load
1) Selfweight
Concrete unit weight = 23.5 kN/m3

2) Member Load
150mm CHB 3.11 kN/m per meter height =8.397 kn/m
100mm CHB 2.98 kN/m per meter height =8.046 kn/m

2nd-9th Floor Load Floors


150mm slab 3.53 kN/m2
roof framing - kN/m2
corrugated roofing sheet - kN/m2
Floor finish 1.10 kN/m2
Ceiling 0.10 kN/m2
MEP 0.10 kN/m2
Interior Partition 1.00 kN/m2
Water proofing - kN/m2
5.83

Roof Floors
100mm slab 4.70 kN/m2
roof framing - kN/m2
corrugated roofing sheet - kN/m2
Floor finish - kN/m2
Ceiling - kN/m2
MEP - kN/m2
Interior Partition - kN/m2
Water proofing 0.26 kN/m2
4.96

Live Load
1.9 kN/m2 3.8 kN/m2

Seismic Parameters
UBC 97 / NSCP 2015
Zone = 4
Seismic Source Type = A
Importance Factor ( I ) = 1 ESSENTIAL FACILITY
R = 8.5 - Special Moment Frame
Structure is located 40km from seismic source
Ct = 0.0731
2.63 0.24 0.24 3.11
2.5 0.24 0.24 2.98
Low‐Rise Buildings : Component and Cladding
Simplified Procedure
ASCE 7-
10
Pnet = λ Kzt Pnet9
1 1
PURLINS (EFFECTIVE AREA = 2.08 m2)
250kph
Zone
1 2 3
1.09 1.09 1.09 kn/m2
-1.85 -3.04 -4.57 kn/m2
PURLIN SPACING = 0.8M

0.545 0.545 0.545 kn/m


-0.925 -1.52 -2.285 kn/m
TRUSS (EFFECTIVE AREA = 18m2)
250kph
Zone
1 2 3
0.85 0.85 0.85 kn/m2
-1.72 -2.44 -3.83 kn/m2
TRUSS SPACING = 2.5M

1.91 1.91 2.13 kn/m 10% least horizontal dimension


-3.87 -5.49 -9.575 kn/m 0.4h
4% least horizontal dimension
0.9
0.6
3
0.24
0.9 governs
TRUSS 1.613 KN 2.25 8 18 0.08961111 KN/M2

PURLINS 0.752 KN 0.5 2.25 1.125 0.66844444 KN/M2

0.75805556 KN/M2
UBC 1997

PARAMETERS T = Ct (hn)0.75 sec UBC Eq. (30-8)


Z 0.4 = 0.341 sec
I 1 < 0.70 sec therefore Ft = 0;
Rwx 8.5
Rwz 8.5
Na 1
Nv 1 V= CvIW KN UBC Eq. (30-4)
S 4 RT
Ct 0.0731 = 386.90 KN
hn 7.8
W 1753.2
Cv 0.64
Ca 0.44

Total design base shear need not exceed:


V = 2.5Ca IW KN UBC Eq. (30-5)
R
= 226.88 KN DESIGN BASE SHEAR IS TOO LARGE!
USE THIS VALUE!

Design base shear shall not be less than:


V = 0.11CaIW KN UBC Eq. (30-6)
= 84.85 KN OK!

V = 0.8ZNvIW KN UBC Eq. (30-7)


R
= 66.00 KN OK!

If Ft≠ 0:
Ft = 0.07TV UBC Eq. (30-14)
= 9.24 KN
< 0.25V = 96.73

ENGR JOHN PAUL DELA ROSA (CE)


LICENSE # 98600_PRC MANILA
0.00420168
1.2 DL + 1.00 E + 0.5 LL

1 1.400 D
1 1.200 D + 1.600 Lp
1 1.420 D + 0.500 Lp + 1.250 E1
1 1.420 D + 0.500 Lp + 1.250 E2
1 1.420 D + 0.500 Lp - 1.250 E1
1 1.420 D + 0.500 Lp - 1.250 E2
1 1.420 D + 1.250 E1
1 1.420 D + 1.250 E2
1 1.420 D - 1.250 E1
1 1.420 D - 1.250 E2
1 0.680 D + 1.250 E1
1 0.680 D + 1.250 E2
1 0.680 D - 1.250 E1
1 0.680 D - 1.250 E2
E = ρ Eh + Ev
1.25

= 1.25 Eh

Ev = 0.5 Ca I DL
0.5 0.44 1 DL
= DL

= 0.22 DL