0% found this document useful (0 votes)
7 views

Str Trace file-Layout1

The document outlines the structural details and specifications for a proposed apartment block, including various beam types and their dimensions. It includes general notes on construction practices, materials, and standards to be followed, such as concrete grades and steel specifications. Additionally, it emphasizes the importance of reading the drawings in conjunction with architectural plans and adhering to engineering approvals.

Uploaded by

atuhe Davis
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
7 views

Str Trace file-Layout1

The document outlines the structural details and specifications for a proposed apartment block, including various beam types and their dimensions. It includes general notes on construction practices, materials, and standards to be followed, such as concrete grades and steel specifications. Additionally, it emphasizes the importance of reading the drawings in conjunction with architectural plans and adhering to engineering approvals.

Uploaded by

atuhe Davis
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1 3 4 5 6 9 11 12

2600 2400 1500 1300 1403 4200 2500 2900


BEAM 101(450X200)
A A

BEAM 132(450X200)
8T10-15-200B2/T2
28T10-16-200B1/T1
1200

BEAM 102(500X200)

BEAM 102(500X200)
B BEAM 110(500X200)
B
1700

BEAM 110(450X200)
D
BEAM 111(450X200)
D BEAM 102(450X200)
D

BEAM 121(450X200)
12T10-15-200B2/T2

8T10-15-200B2/T2
28T10-16-200B1/T1
64T10-16-200B1/T1
BEAM 119(450X200)

BEAM 120(450X200)
2500

BEAM 112(450X200)
E
40T12-13-2Prb.B1/T1
Length Varies.

F F
BEAM 103(450X200)
1400

G G

BEAM 129(450X200)

BEAM 128(450X200)
BEAM 104(450X200)
1918

BEAM 113(450X200)
3801
BEAM 118(500X200)

BEAM 117(450X200)

BEAM 116(450X200)

12T10-15-200B2/T2
64T10-16-200B1/T1
1883

BEAM 114(450X200)
K K
BEAM 105(450X200)

BEAM 115(450X200)
12T10-15-200B2/T2
3800

64T10-16-200B1/T1

M M
BEAM 106(450X200)
1400

N N
BEAM 107(450X200)
BEAM 122(450X200)
BEAM 124(450X200)
2500

O BEAM 107(450X200)
O
1700

Q BEAM 109(450X200)
Q
1199

R BEAM 108(450X200)
R

1 3 4 5 6 9 11 12

GENERAL NOTES
PROJECT: PROPOSED APARTMENT BLOCK DRAWING TITLE:
REINFORCEMENT STEEL STRUCTURAL STEEL
Trace file GENERAL NOTES CONCRETE
3. All fillet welds shall be 6mm minimum continuous on all sides
1. All Engineer's drawings shall be read in conjunction with the 1. Foundations shall be constructed on firm natural ground. 1. All reinforcing steel to be High yield bars(>500N/mm²) to be 1. All steel work is to be designed in accordance with BS EN by welders approved to BS 4872 Part 1
Architect's drawings.Any discrepancies should be reported Blinding shall not be placed without Engineer's approval. ribbed cold formed bars to BS4461 and are marked 1993 DESIGN OF STEEL structures.All Structural steel shall 4. All steel to steel connection bolts are to be of grade 8.8. All
2. Concrete shall be of grade C25, medium slump (75) & "H" on these drawings. be hot rolled sections of grade S275 conforming to the steel to concrete bolts are to be of grade 4.8
CLIENT:
ISSUE STATUS: STRUCTURAL ENGINEER:
2. These drawings shall be read in conjunction with Standard &
Particular Specifications. 3.
·
maximum aggregate size 20mm.
Minimum Concrete cover to all steel shall be:
Foundations=50mm,Beams,slabs& Columns=25mm
2. Overlapping lengths shall be as below;
H25 = 1250mm H20 = 1000mm
2.
requirements of BS EN 1993.
Hot rolled steel sections ,plates, flats shall be to grade
S275J0 to BS EN 10025. Hollow sections shall be to 1.
STRUCTURAL TIMBER

Timber shall be of Strength Grade C18 Minimum conforming


01
3. All dimensions are in mm unless otherwise stated. All H16 = 800mm H12 = 600mm S355J0H to BS EN 10210.Steel connections are designed to BS 5268.
dimensions to be confirmed on site H10 = 500mm according to BS 5950:1 2. All timber to be pressure impregnated to Engineers Approval
3. Timber to be varnished or painted with fire retarding paint.