23
23
E-mail : [email protected]
General Notes
NOTE:
This drawing is the copyright of
ARCADE ENGINEERING BUREAU
and must not be retained, copied or
used without the above consultants
authority.
GENERAL NOTES FOR STRUCTURAL STEEL AND MISCELLANEOUS STEEL WORKS CONNECTIONS GRADE-C CONFORMING TO IS: 1363. GUSSET/END PLATES SHALL BE OF FOLLOWING MINIMUM THICKNESS
UNLESS STATED OTHERWISE, ALL SHOP CONNECTIONS SHALL BE BY d.) ALL HIGH STRENGTH STRUCTURAL BOLTS SHALL BE OF PROPERTY
GENERAL 'v\£LDING AND FIELD CONNECllON GENERALLY SHALL BE BOLTED USING CLASS 8.8 GRADE-A CONFORMING TO IS:1367 & SHALL BE SUPPLIED UNLESS SPECIFIED OTHERWISE :
HIGH STRENGTH FRICTION GRIP (HSFG) BOLTS OF 8.8 GRADE. FOR CONFORMING TO IS: 3757 i) FOR BEAMS OF DEPTH LESS THAN 450 : - 8 MM.
a.) ALL DIMENSIONS ARE IN MILLIMETRES EXCEPT FLOOR ELEVATIONS SECONDARY TO MAIN BEAMS H. T BOLTS SHALL BE USED.(8.8 GRADE)
e.) ALL NUTS SHALL BE OF HEAVY DUTY HEXAGONAL TYPE AND SHALL BE ii) FOR BEAMS OF DEPTH 450 TO 600 : - 10 MM.
iv) COLUMN SPLICE TO BE DESIGNED FOR FULL CAPACITY PLUS 5% ADDITION b.) ALL CONNECTIONS SHALL BE DEVELOPED IN LINE WITH GOOD COMPATIBLE WITH THE BOLTS. MS NUTS SHALL BE OF CARBON STEEL
ENGINEERING PRACTICE AND SHALL BE SUBJECT TO THE APPROVAL PRODUCT GRADE-C OF IS:1363 AND OF PROPERTY CLASS 5 OF IS:1367 iii) TRUSS/BRACINGS, WITH MEMBER THICKNESS 8 MM. & LESS - 8MM.
CAPACITY OF LOWER SECTIONS. OF THE ENGINEER.
f.) ALL NUTS & WASHERS FOR HIGH SllRENGTH BOLTS (H.S.F.G.) SHALL iv) TRUSS/BRACINGS, WITH MEMBER THICKNESS MORE THAN 10MM.-12MM.
c.) THE SIZE OF FILLET 'v\£LD SHALL BE 5 MM. MINIMUM UNLESS CONFORM TO IS: 6623 & IS: 6649 RESPECTIVELY.
PLANT GRID WHICH ARE IN METRE UNLESS STATED OTHERWISE.
b.) ALL ELEVATIONS ARE WITH RESPECT TO MAIN PO'v\£R HOUSE BUILDING
NOTED OTHERWISE.
THE FIELD CONNECTION OF PURLINS SHALL BE WITH H.T BOLTS. THE MEMBERS CONNECTED. A WASHER OF ADEQUATE THICKNESS MAY BE
UNLESS OTHERWISE STATED IN THE DESIGN DRAWINGS, THE CONNECTION
SHALL BE DESIGNED FOR THE FOLLOWING LOADS: Designed by :
GROUND FLOOR LEVEL' AS EL.(±)O.OO M. WHICH CORRESPONDS TO FOR SAG ANGLE & WALL BEAMS SHALL BE DONE WITH M.S BOLTS PROVIDED TO EXCLUDE llHE llHREADS FROM THE BEARING llHlCKNESS IF
RL.+45.50 M ABOVE M.$.L. THE DIAMETER OF BOLT SHALL BE 20MM (MINIMUM) FOR HIGH STRENGTH A LARGER GRIP BOLT HAS TO BE USED FOR THIS PURPOSE. i) MOMENT CONNECTIONS DESIGNATED AS MC TO BE DESIGNED FOR
c.) ALL DRAWINGS SHALL BE READ IN CONJUNCTION WITH THE TERMS, FRICTION GRIP AND 16 MM. (MINIMUM) FOR MS BOLTS. ALL ERECllON BOLT HOLES SHALL BE SUITABLY PLUGGED. THE FULL CAP ACITY OF THE MEMBER. Arc. Designer
Ismael Mohammed Qader
CONDITIONS AND SPECIFICATIONS OF THE CONTRACT. ID NO. : 12758 Hawler
d.) THE FABRICAllON & ERECllON OF STRUCTURAL STEEL SHALL BE f.) ALL BOLT CONNECTIONS SHALL HAVE MINIMUM TWO BOLTS. 0.) FOR ERECllON AND TEMPORARY ASSEMBLY M.S BLACK BOLTS TO BE USED, ii) SHEAR CONNECTIONS WILL BE DESIGNED FOR 60% OF SECllON STRENGTH
IN ACCORDANCE WITH IS: 800 - CODE OF PRACllCE FOR GENERAL WHICH SHALL BE REMOVED AFTER FINAL WELDING. OPENING OF HOLES llHUS FOR ROLLED SECllONS AND 80% OF SECllON STRENGTH FOR BUILT UP
CONSTRUCTION IN STEEL AND AS SPECIFIED IN THE CONTRACT g.) LENGTH OF FILLET 'v\£LDS SHALL NOT BE LESS THAN FOUR TIMES OF LEFT SHALL BE PLUG 'v\£LDED. SECTION OR ROLLED SECTION WITH COVER PLATES. IN ANY CASE, THE sign :
TECHNICAL SPECIFICATIONS. DESIGNED VALUE SHALL NOT BE LESS THAN THE ACTUAL SHEAR.
p.) FOR COLUMNS FOUNDATION BOLTS, AT LEAST DOUBLE NUTS SHALL BE
B. MATERIAL D PAINTING PROVIDED. iii) CONNECTIONS FOR BEAMS IN COLUMN LINE TO BE DESIGNED FOR
Soran Mohammed Rasul
a.) ALL MATERIALS SHALL BE NEW, CLEAN, RUST FREE AND STRAIGHTENED . FOR INDOOR & OUTDOOR STEEL STRUCTURES THE MINIMUM AXIAL LOAD OF 7.5 MT.(TENSION/COMPRESSION) UNLESS Str. Designer
IF NECESSARY BEFORE BEING WORKED. (ALL STRUCTURAL STEEL AND HANDRAILS SHALL BE PAINTED AS FOLLOWS) q.) OVER HEAD 'v\£LDING SHALL NOT BE RESORTED TO UNLESS SPECIFICALLY HIGHER LOAD IS SPECIFIED IN ADDITION TO REQUIRED SHEAR/ MOMENT ID NO. : 12615 Hawler
b.) ALL 'v\£LDING ELECTRODES SHALL BE OF LOW HYDROGEN TYPE g.) WASHERS FOR MILD STEEL BOLTS SHALL BE OF MILD STEEL CONFORMING LOAD. IN ANY CASE, THE DESIGNED AXIAL LOAD SHALL NOT BE
a) ALL STEEL STRUCTURES SHALL BE RECEIVE TWO PRIMER COATS TO IS:5369 / IS:5372 OR IS:5374 OR IS:2016 AS THE CASE MAY BE. LESS THAN THAN THE ACTUAL TENSION/ COMPRESSION.
CONFORMING TO IS:816. sign :
& TWO PROVIDED IN DRAWING.. h) JOINTS TO BE SITE 'v\£LDED SHALL HAVE NO PAINT APPLIED WITHIN 100 mm
FINISH COATS OF PAINTING. FRIST COAT OF PRIMER SHALL BE GIVEN IN SHOP OF WELDING ZONE .SlMILARLY WHERE FRICTION GRIP FASTENERS ARE TO BE
c.) ALL MILD STEEL BOLTS SHALL BE OF PROPERTY CLASS 4.6 AFTER FABRICATION. SECOND COAT OF PRIMER SHALL BE APPLIED AFTER r.) PROPER PRE-HEATING TEMPERATURE SHALL BE MAINTAINED AS PER SPEC. USED NO PAINTING SHALL BE PROVlDED.ON COMPLETION OF JOINTS llHE
ERECTION AND FINAL ALIGNMENT OF llHE ERECTED SllRUCTURES. TWO S.) THE 'v\£LDING SEQUENCE/ PROCESS SHALL BE SO ADOPTED THAT NO llHE SURFACES SHALL RECEIVE llHE PAINT AS SPECIFIED.
Shayda Omer Ali
Elec. Designer
iV) CONNECTION FOR ALL TRUSS MEMBERS TO BE DESIGNED FOR FULL FINISH COAT SHALL ALSO BE APPLIED AFTER ERECTION. i) SURFACES INACCESSIBLE AFTER ASSEMBLY SHALL RECEIVE TWO COATS OF ID NO. : 08883 Hawler
ALL ANCHOR BOLTS SHALL BE MILD STEEL OF GRADE 4.6 PRIMER PRIOR TO ASSEMBLY.SURFACES INACCESSIBLE AFTER ERECTION
TENSILE STRENGTH OF THE: MEMBER. b) STEEL SURFACE SHALL BE CLEANED OF DUST & GREASE AND HEAVIER INCLUDING TOP SURFACES OF FLOOR BEAMS SUPPORTING GRATINGS OR
CONFORMING TO IS: 5624 OR CHEQUERED PLATE SHALL RECEIVE ONE ADDITIONAL COAT OF FINISH PAINT sign :
LAYERS OF RUST SHALL BE REMOVED BY CHIPPING PRIOR TO ACTUAL OVER AND ABOVE NUMBER OF COATS SPECIFIED BEFORE ERECTION. PORTION OF
vi) CONNECTION FOR BRACING MEMBERS TO BE DESIGNED FOR FULL
SURFACE PREPARATlON.llHE SURFACE SHALL BE CLEANED AS PER IS 1477 ACCUMULATlON OF SECONDARY 'v\£LDING STRESSES TAKES PLACE STEEL MEMBER EMBEDDED/ TO BE ENCASED IN CONCRETE SHALL NOT BE
TENSILE STRENGTH OF THE MEMBER. (PART-I). THE MEMBERS. PAINTED.
Ranj Neamat Azeez
Mec. Designer
ID NO. : 09526 Hawler
vii) SIZE OF FILLET WELD FOR FLANGE TO 'v\£B CONNECTION FOR BUILT UP c) PRIMER COAT SHALL BE CONSIST OF TWO COATS OF REDOXIDE ZINC-CHROMATE I.) ALL STRUCTURAL AND MISCELLANEOUS STEEL WORK SHALL BE OF
PRIMER EACH HAVING MINIMUM DFT OF 25 MICRONS. AS PER IS: 1477(PARTS 1& MILD STEEL CONFORMING TO FOLLOWING INDIAN STANDARDS:
SECTION SHALL BE AS FOLLOWS : ALL PAINTS SHALL BE OF APPROVED BRAND AND SHADE AS PER OWNER'S sign :
REQUIREMENT. i) STRUCTURAL SHAPES
0) FULL SHEAR CAPACITY OR ACTUAL SHEAR, WHICHEVER IS MORE d) FINAL COAT SHALL CONSIST OF TWO FINAL COATS OF SYNTHETIC ENAMEL ii) PLATE UPTO 20 MM. THICKNESS
PAINT HAVING MINIMUM OFT OF 50 MICRONS OF APPROVED BRAND AS iii) PLATE ABOVE 20 MM. THICKNESS
FOR BOX SECTION. PER OWNER'S REQUIRMENT. Client Name
IS: 2062 (GRADE A)
b) 80% OF FULL SHEAR CAPACITY OR ACTUAL SHEAR OR 0.5 OF 'v\£B e) TOTAL OFT WITH PRIMER SHALL NOT BE LESS 110 MICRONS.
THICKNESS, WHICHEVER IS MORE. FOR I SECllON, WELD SHALL BE IS: 2062 (GRADE A)
DOUBLE FILLET. f) ALL OTHER STEEL MEMBERS LIKE DOORS, ROLLING SHUTTERS, PIPE SUPPORTS MUHAMMED JAWDAT HAIDAR
viii) THE CONNECllON BETWlEEN TOP FLANGE AND 'v\£B OF CRANE GIRDER ETC. SHALL BE PAINTED AS PER DETAILS. IS: 2062 (GRADE B)
SHALL BE FULL PENETRATION BUTT 'v\£LD AND FOR BOTTOM FLANGE g) INTERMEDIATE/TOP/FINISHINGING COAT PAINTS SHALL BE FORM llHE SAME Plot No. E 115-1 TEMARI GAWRA
MANUFACTURE & THE PAINTS SHALL HAVE CAPATlBILITY WITH ONE ANOTHER (KILLED & NORMALISED)
CONNECllON, FILLET WELD MAY BE PROVIDED. APPLICATlON SHALL BE AS PER MANUFACTURES RECOMMEND A1l0NS.
iv) PLATE FOR CRANE GIRDER Plot Area 800 M²
ix) CONNECllON OF BASE PLATE AND GUSSET MEMBERS WITH COLUMNS SHALL THE NOMINAL SIZE OF THE 'v\£LD OR 40 MM. WHICHEVER IS MORE.
BE DONE CONSIDERING THAT TOTAL LOAD GETS llRANSFERED THROUGH 'v\£LD.
h.) FILLET 'v\£LD TERMINATING AT ENDS MUST HAVE RETURN AROUND
IS: 2062 (GRADE C)
Total Built Area 750 M²
n.) IN ALL CASES, THE UNTHREADED PORTION OF THE BOLT SHALL BEAR ON
CORNERS NOT LESS THAN TWICE THE NOMINAL SIZE OF THE WELD. v) STRUCTURAL PIPES
vi) STRUCTURAL HOLLOW SECTIONS
I.) BUTT 'v\£LDS SHALL BE FULL PENETRA1l0N BUTT 'v\£LD. C Project Name
j.) THE DIAMETER OF BOLT HOLES SHALL NOT BE MORE THAN 2 MM.
IS: 806 (YST 25)
OF THE DIAMETER OF BOLT UNLESS STATED OTHERWISE. IS: 4923
THE ERECllON CLEARENCE FOR END OF MEMBERS SHALL NOT BE MORE (SQUARE & RECTANGULAR)
THAN 5 ,MM. AT EACH END UNLESS STATED OTHERWISE. PIPES OF HANDRAIL FACTORY PROJECT
L.)
IS:1161
Foundation Plan
Sheet No. :
ST-02
Date : Scale :