0% found this document useful (0 votes)
5 views

01

The document outlines general structural and construction notes for a project, including definitions, material specifications, and construction requirements. It specifies standards for concrete, steel, and welding, as well as guidelines for footings, rebar details, and curing processes. The contractor is required to adhere to these specifications and submit relevant documentation for approval prior to construction activities.

Uploaded by

engineeravbp
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
5 views

01

The document outlines general structural and construction notes for a project, including definitions, material specifications, and construction requirements. It specifies standards for concrete, steel, and welding, as well as guidelines for footings, rebar details, and curing processes. The contractor is required to adhere to these specifications and submit relevant documentation for approval prior to construction activities.

Uploaded by

engineeravbp
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1 2 3 4 5 6 7 8 9 10 11 12

GENERAL STRUCTURAL & CONSTRUCTION NOTES NOTE:


A 1. DEFINITIONS: A
PEDESTAL
1. FOR THE INTERPRETATION OF THESE DRAWINGS, THE INDICATED DIMEN-
A. CORPORATION - SHALL MEAN THE EDC FACILITY OPERATIONS AND
SIONS SHALL GOVERN AND DISTANCES OR SIZES SHALL NOT BESCALED 16. STIRRUP AND TIE HOOK DETAILS: MAINTENANCE GROUP PROJECT REPRESENTATIVE(S).
FOR CONSTRUCTION PURPOSES. INTERFACE OF NEW
PROVIDE TO OLD CONCRETE
2. IN CASE OF DISCREPANCIES AS TO LAYOUT DIMENSIONS, ELEVATIONS, CONCRETE EPOXY
ETC. BETWEEN STRUCTURAL PLANS AND PIPING DRAWINGS, THE º
135

VARIES
CONTRACTOR SHALL NOTIFY THE CORPORATION.
6d

25
3. MATERIALS SPECIFICATION: b
O
R
75
A. UNLESS OTHERWISE INDICATED IN THE PLANS OR NOTED IN m
m
THE SPECIFICATION, THE MINIMUM 28 DAYS CYLINDER COM- DRILL HOLE
B PRESSIVE STRENGTH OF CONCRETE SHALL BE f'c = 21 MPa (3.0 ksi) 13. ON FOOTINGS: B
CLASS "C" MIX SHALL BE USED FOR LEAN CONCRETE. D
A. FOOTINGS ARE DESIGNED FOR AN "ASSUMED" ALLOWABLE SOIL BEARING
B. ALL REINFORCING BARS SHALL BE DEFORMED, IN ACCORDANCE CAPACITY OF 100 kPa (OR AS SPECIFIED IN THE SCHEDULE OF SUPPORTS.)
TO ASTM A615M. BARS 16 MMØ AND BELOW SHALL BE OF CONTRACTOR SHALL REPORT TO THE CORPORATION THE ACTUAL
STRUCTURAL GRADE WITH A MINIMUM YIELD STRESS OF Fy = 275MPa SOIL CONDITIONS UNCOVERED AND CONFIRM ACTUAL SOIL
(40 ksi). BARS 20 MMØ & ABOVE SHALL BE OF INTERMEDIATE GRADE BEARING CAPACITY OF SOIL BEFORE DEPOSITING CONCRETE.
WITH A MINIMUM YIELD STRENGTH OF Fy = 414 MPa (60 ksi).
B. FOOTINGS SHALL REST AT LEAST 1000MM BELOW NATURAL STIRRUP HOOKS
C. STRUCTURAL STEEL SECTIONS AND PLATES SHALL CONFORM GRADE LINE UNLESS OTHERWISE INDICATED.
TO ASTM A36. STRUCTURAL STEEL PIPES SHALL CONFORM ( TIE BEND SIMILAR )
TO ASTM A53, TYPE E OR S, GRADE B, STANDARD WEIGHT. C. FOOTINGS ON FILL SHALL BE CONSTRUCTED AS DIRECTED
FOR EARTHWORKS FILL IN THE TECHNICAL SPECIFICATIONS.
D. WELDING ELECTRODES SHALL CONFORM TO AWS D1.1 AS FOLLOWS:
C AWS A5.5 E70-XX AND E70-XX FOR CARBON STEEL CONNECTION 14. MINIMUM EMBEDMENT LENGTH AND LAPPED SPLICES OF REBARS: C
E70-XX SHALL BE USED FOR ROOT PASS STIRRUP AND TIE HOOK DIMENSIONS (mm)
E70-XX FOR SUCCEEDING PASS UNTIL CAPPING GRADES 40 ksi
AWS A5.4 E309-XX FOR STAINLESS AND CARBON STEEL CONNECTION
AWS A5.4 E308L-XX FOR STAINLESS AND STAINLESS CONNECTION BAR SIZE D 135° HOOK
Ld

Ldh
(DEFORMED) (mm) (mm)
E. ANCHOR BOLTS, BOLTS FOR STRUCTURAL CONNECTIONS,
10 mmØ 40 75
NUTS AND WASHERS SHALL CONFORM TO THE FOLLOWING:
ANCHOR BOLTS - ASTM 325 12 mmØ 48 75

BOLTS FOR STRUCTURAL CONNECTION - ASTM 325 16 mmØ 64 96


NUTS AND WASHERS - ASTM A563
UNLESS OTHERWISE SPECIFIED. THESE ITEMS SHALL BE GALVANIZED
NOTE:
ACCORDING TO ASTM A153 CLASS C. 135° COLUMN TIE HOOK MAY NOT BE
12db
BENT LESS THAN DIAMETER OF COLUMN
D VERTICAL BAR ENCLOSED IN HOOK. D
F. EXPANSION BOLTS & CHEMICAL ANCHORS SHALL BE HILTI-BRAND OR APPROVED
EQUAL. TYPICAL EMBEDMENT DETAIL TYPICAL SPLICE DETAIL 17. ALL WELDED CONNECTIONS SHALL BE WELDED ALL AROUND
OR SEAL WELDED.
4. ALL CONCRETE WORKS SHALL BE DONE IN ACCORDANCE WITH THE fc' = 20.7MPa (3ksi)
REQUIREMENTS OF THE LATEST EDITION OF ACI 318 FOR STRUCTURAL BAR SIZE
(DEFORMED) EMBEDMENT 12db LAP, Ld 18. UNLESS OTHERWISE SPECIFIED, THE MINIMUM SIZE OF FILLET
CONCRETE, AND ALL STRUCTURAL STEEL WORKS IN ACCORDANCE Ldh (mm) (mm) (mm) WELD FOR WELDED PARTS SHOULD BE AS FOLLOWS:
WITH THE AISC SPECIFICATION AS LONG AS THEY ARE
10 mmØ 200 120 435
NOT IN CONFLICT WITH THE LOCAL BUILDING CODE REQUIREMENT.
12 mmØ 200 150 520

5. DEFINITIONS: 16 mmØ 250 200 695 PLATE THICKNESS MIN. FILLET WELD SIZE
(mm) (mm)
ACI - AMERICAN CONCRETE INSTITUTE 20 mmØ 300 240 870
t<6 3
AISC - AMERICAN INSTITUTE OF STEEL CONSTRUCTION 25 mmØ 400 300 1350
ASTM - AMERICAN SOCIETY FOR TESTING AND MATERIALS 6 < t < 12 5
28 mmØ 450 340 1512
E AWS - AMERICAN WELDING SOCIETY 12 < t < 19 6
E
15. REBARS STANDARD HOOK DETAILS: 19 < t < 38 8
6. CONCRETE SHALL BE DEPOSITED IN ITS FINAL POSITION WITHOUT 38 < t < 57 10
SEGREGATION, RE-HANDLING OR FLOWING. USE OF CHUTES SHALL DETAILING HOOK DETAILING
NOT EXCEED SIX(6) METERS IN AGGREGATE LENGTH. DIMENSION A OR G DIMENSION
19. UNLESS OTHERWISE SPECIFIED, THE MINIMUM EDGE DISTANCE
FROM CENTER OF STANDARD BOLT HOLE TO EDGE OF
7. NO DEPOSITING OF CONCRETE SHALL BE ALLOWED WITHOUT THE USE
CONNECTED PART SHALL BE AS FOLLOWS:
OF MECHANICAL VIBRATORS UNLESS AUTHORIZED IN WRITING BY THE

A OR G
CORPORATION AND ONLY FOR UNUSUAL CONDITIONS WHERE VIBRATION
J
db

db

12db
IS EXTREMELY DIFFICULT TO ACCOMPLISH.
MINIMUM EDGE DISTANCE
D NOMINAL BOLT
8. CURING OF CONCRETE SHALL BE CONTINUOUS FOR A MINIMUM PERIOD 4dB OR 65 (MIN) DIAMETER SHEARED EDGES AT ROLLED EDGES OF
PLATES, SHAPES OR
(mm)
OF FOURTEEN (14) DAYS IMMEDIATELY AFTER POURING. OR BARS (mm)

180° 90° 12 mmØ 22 20


F 9. MINIMUM CONCRETE PROTECTION FOR REINFORCEMENTS SHALL BE D = BAR DIAMETER 16 mmØ 30 22 F
75 MM CLEAR FOR CONCRETE DEPOSITED AGAINST GROUND AND 65 MM = 6db FOR 10MMØ 20 mmØ 32 25
FOR CONCRETE DEPOSITED AGAINST A FORMWORK. THROUGH 25MMØ
22 mmØ 38 28
= 8db FOR 28MMØ
AND 32MMØ 25 mmØ 45 32
10. THE CONTRACTOR SHALL SUBMIT THE SCHEDULE OF POURING AND
28 mmØ 50 38
LOCATIONS OF CONSTRUCTION JOINTS TO THE COMPANY AT LEAST DIMENSION OF STD.
24 HOURS PRIOR TO POURING FOR APPROVAL. DIMENSION OF STANDARD 90° HOOKS, 32 mmØ 60 40
BAR SIZE 180° HOOKS, ALL GRADES (mm)
ALL GRADES (mm) OVER 32 mmØ 1 3/4 x DIAMETER 1 3/4 x DIAMETER
(DEFORMED)
11. THE CONTRACTOR SHALL FURNISH AND MAINTAIN ADEQUATE FORMS A OR G J D A OR G D

AND SHORINGS UNTIL THE CONCRETE MEMBERS HAVE ATTAINED THEIR 10 mmØ 125 80 60 155 60
20. ALL EXPOSED STRUCTURAL STEEL WORKS SHALL BE PROVIDED
WORKING CONDITION AND STRENGTH. 12 mmØ 150 100 80 205 80
WITH SURFACE PROTECTION AGAINST CORROSION.
16 mmØ 175 130 100 255 95
12. ON REINFORCED CONCRETE PEDESTALS: 20 mmØ 200 155 115 305 115
A. ALL REINFORCED CONCRETE PEDESTALS SHALL BE PROVIDED 22 mmØ 250 180 135 360 135
G WITH ADDITIONAL SET OF TIES AS NOTED ON DRAWING NO. G
25 mmØ 280 205 155 410 155
44.0-A2-S-103.
28 mmØ 380 285 230 485 230

B. IN CONSTRUCTING CONCRETE PEDESTALS TO EXISTING STRUC- 32 mmØ 430 325 260 560 260

TURES, DRILL HOLES 3MM GREATER THAN THE REBAR DIAMETER


AND BOND NEW TO OLD CONCRETE.

AVBP / ___ 03/11/25

H
LEYTE GEOTHERMAL PRODUCTION FIELD -
H
FACILITIES OPERATIONS & MAINTENANCE (FOM) TEL. NO.(632) 7755-2332
TECHNICAL SERVICES - ENGINEERING DESIGN FAX NO.(632) 7755-2332 GENERAL STRUCTURAL & CONSTRUCTION NOTES AVBP /SMC SMC
6/F ROCKWELL BUSINESS CENTER TOWER 3, P.O. BOX 1604
e n e r g y ORTIGAS AVENUE, 1604, PASIG CITY,
DEVELOPMENT CORPORATION METRO MANILA, PHILIPPINES. TONGONAN WELL BRANCHLINE CONVERSION 2 1 2 03/11/25 ISSUED FOR COMMENTS AVBP SMC
8

1 2 3 4 5 6 7 8 9 10 11 12 A2