The JC multicore square ceiling diffuser is designed for versatile air diffusion in heating, cooling, and ventilation systems, offering 1 to 4 way airflow patterns. It is made from extruded aluminum or galvanized steel, with options for various finishes and dimensions. Performance data includes airflow rates, noise levels, and throw distances, with adjustments needed based on application height.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13 views2 pages

jc

The JC multicore square ceiling diffuser is designed for versatile air diffusion in heating, cooling, and ventilation systems, offering 1 to 4 way airflow patterns. It is made from extruded aluminum or galvanized steel, with options for various finishes and dimensions. Performance data includes airflow rates, noise levels, and throw distances, with adjustments needed based on application height.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

SQUARE CEILING DIFFUSER

TYPE JC

INTRODUCTION
The JC multicore square ceiling
diffuser is a versatile form of air terminal
offering 1 to 4 way horizontal air
diffusion patterns. The diffuser is
suitable for supply, return and exhaust
air in cooling, heating and ventilation FEATURES
systems. It is widely used because it • Directional core is removable providing
ensures maximum airflow at minimum access to accessories, connecting duct,
noise level, and suitable for virtually and are interchangeable in the field for
any type of ceiling. same size diffusers.

MATERIAL • Standard flat frame square JC diffuser is


• Extruded aluminium (JC-A) designed to replace standard tile ceiling
• Galvanized steel (JC-S) panel or cover ceiling opening.

FINISH • Other frames are available on request.


Natural anodized for aluminium (For further details please contact ACE
construction or white powder coated office.)
as standard. Other finishes are
available as options.

DIMENSION

All dimensions are in mm.

1
PERFORMANCE DATA

SQUARE CEILING DIFFUSER - TYPE JC


NECK SIZE SELECTION NECK AIR VELOCITY (m/s)
(mm) PARAMETER 1 1.5 2 2.5 3 3.5
Pt Total Pressure (Pa) 2.5 5 8 14 20 27
Airflow Rate (l/s) 24 36 48 58 70 80
150 x 150 Throw (m) Min-Max 0.4 - 1.2 0.6 - 2.0 1.2 - 3.2 1.4 - 3.8 1.9 - 4.0 2.0 - 4.5
NR Level 19 22 25 28
Airflow Rate (l/s) 54 80 106 132 156 182
225 x 225 Throw (m) Min-Max 0.4 - 2.0 1.1 - 3.2 1.4 - 4.0 1.7 - 4.4 2.1 - 4.8 2.6 - 5.2
NR Level 20 23 26 30
Airflow Rate (l/s) 98 144 188 234 278 324
300 x 300 Throw (m) Min-Max 0.8 - 3.0 1.2 - 4.0 1.6 - 4.6 2.2 - 5.0 2.9 - 5.6 3.2 - 6.2
NR Level 21 25 29 34
Airflow Rate (l/s) 160 226 296 366 436 508
375 x 375 Throw (m) Min-Max 1.0 - 3.6 1.6 - 4.4 2.2 - 5.2 3.0 - 5.8 3.5 - 6.5 4.2 - 7.2
NR Level 22 27 33 37
Airflow Rate (l/s) 236 320 426 526 628 730
450 x 450
Throw (m) Min-Max 1.4 - 4.2 2.0 - 5.0 2.8 - 5.8 3.4 - 6.5 4.0 - 7.0 4.5 - 7.8
Or Tile Size
NR Level 19 24 30 35 39
Airflow Rate (l/s) 318 438 582 720 856 994
525 x 525 Throw (m) Min-Max 1.6 - 4.6 2.2 - 5.3 3.2 - 6.0 4.0 - 7.2 4.2 - 7.8 4.6 - 8.2
NR Level 26 33 37 41
Airflow Rate (l/s) 416 580 760 940 1120 1300
600 x 600 Throw (m) Min-Max 1.8 - 4.8 2.8 - 5.9 3.8 - 6.8 4.3 - 7.4 4.6 - 8.2 5.0 - 9.0
NR Level 22 28 35 38 43

Performance data is tested basing on A. D. C. standard.

EXTRACT PERFORMANCE DATA


Without Pt Total Pressure (Pa) 3 6 10 17 24 32
OB Damper NR Level +3 +3 +3 +3 +4 +5
With OB Pt Total Pressure (Pa) 3 6 11 19 27 35
Damper NR Level +3 +4 +4 +5 +8 +8

THROWS - Maximum and minimum throws NOISE LEVELS - Noise data is


are based on jet terminal velocities (Vt) expressed in terms of NR level with a
of 0.25 and 0.75m/s respectively and room absorption factor of 8dB. Where
correspond to average room air velocities dampers are fitted to the diffuser some
(Vr) of 0.1 and 0.25m/s with a temperature allowance should be make for open
differential of 11˚C and room height of or partially throttled blades.
2.7m. Where the application height differs
from this, throw selections should be
adjusted accordingly; that is increasing the
throw by 1m for every 1m increase in height.