Design of PIS Sample 1
Design of PIS Sample 1
System
(Sample Computation)
Parameter Value
Area to be irrigated, A 50 meter x 100 meter
Soil infiltration rate 10 mm/hr
Allowable moisture depletion, MAD 50%
Soil Field Capacity (FC) 28%
Permanent Wilting Point (PWP) 14%
Crop coefficient, Kc 0.95
PET (hot, dry) 7.6 mm/day
Root-zone depth, drz 600 mm
Wind velocity 4 km/hr
Irrigation Efficiency, Ea 75%
Layout.
100 meters
P
Pump
50 meters
Area = 5,000 m2
1. Net depth of water application
𝑑𝑛𝑒𝑡 = 𝐹𝐶 − 𝑃𝑊𝑃 × 𝑑𝑟𝑧 × 𝑀𝐴𝐷
(28 − 14)
𝑑𝑛𝑒𝑡 = × 0.6𝑚 × 0.5
100
𝒅𝒏𝒆𝒕 = 𝟎. 𝟎𝟒𝟐 𝒎 = 𝟒𝟐 𝒎𝒎
2. Irrigation frequency
𝑑𝑛𝑒𝑡 𝐸𝑇𝑎 = 0.95 𝑥 7.6 𝑚𝑚/𝑑𝑎𝑦
𝐼𝑓 =
𝑝𝑒𝑎𝑘𝐸𝑇𝑎 𝐸𝑇𝑎 = 7.22 𝑚𝑚/𝑑𝑎𝑦
42 𝑚𝑚
𝐼𝑓 = 𝑚𝑚
7.22
𝑑𝑎𝑦
𝑑𝑛𝑒𝑡 = 𝑝𝑒𝑎𝑘𝐸𝑇𝑎 × 𝐼𝑓
𝑚𝑚
𝑑𝑛𝑒𝑡 = 7.22 × 6 𝑑𝑎𝑦𝑠
𝑑𝑎𝑦
𝒅𝒏𝒆𝒕 = 𝟒𝟑. 𝟑𝟐 𝒎𝒎
3. Gross depth
𝑑𝑛𝑒𝑡
𝑑𝑔𝑟𝑜𝑠𝑠 =
𝐸𝑎
43.32
𝑑𝑔𝑟𝑜𝑠𝑠 =
0.75
𝒅𝒈𝒓𝒐𝒔𝒔 = 𝟓𝟕. 𝟕𝟔 𝒎𝒎
4. Preliminary system capacity
10 × 𝐴 × 𝑑𝑔𝑟𝑜𝑠𝑠
𝑄𝑝𝑟𝑒𝑙𝑖𝑚 =
𝐼𝑓 × 𝑁𝑠ℎ𝑖𝑓𝑡 × 𝑇
10 × 5000 × 57.76
𝑄𝑝𝑟𝑒𝑙𝑖𝑚 =
6 𝑑𝑎𝑦𝑠 × 1 × 18
𝟑
𝒎
𝑸𝒑𝒓𝒆𝒍𝒊𝒎 = 𝟐. 𝟔𝟕
𝒉𝒓
5. Choose Sprinkler (from Catalogue)
5.8
Maximum sprinkler spacing as related to wind velocity, square
pattern
Average Wind Speed Spacing as Percent of Wetted
(km/hr) Diameter (D)
Up to 5 55%
6-11 50%
13-19 45%
SOURCE: FAO – Irrigation Manual Volume III – Module 8, 2001
lateral
x x x x x x x x x x x x x x x
6.25
6.25 m
x x x x x x x x x x x x x x x
6.25 m
8. System Capacity, Q
Q = Nlateral x Nsprinkler x q
Q = 7 x 15 x 0.210 m3/hr
Q = 22.05 m3/hr = 6.125 lps
9. Determine Pipe Diameter, Dm
Q = AV
Q = (πD2/4) V
D = (4Q/ πV)1/2 ; allowable V = 2 m/s = 7200 m/hr
Ha = Hd + 0.26hl + SeLl/2 ;
assume slope = relatively flat
Ho = Ha + 0.74hl + SeLl/2 ;
assume slope = relatively flat
TDH = Hn + Hm + Hj + Hs
Assume Hj = 1 m; Hs = 3 m
TDH = 35.86 + 0.81 + 1 + 3
TDH = 40.67 m
15. Power Requirement
𝑄 𝑥 𝑇𝐷𝐻
𝑃=
360 𝑥 𝐸𝑝
22.05 𝑥 40.67
𝑃= Assume Pump efficiency = 60%
360 𝑥 0.60
P = 4.15 kW = 5.6 Hp
Layout.
100 meters
P
50 meters
mainline
lateral
x x x x x x x x x x x x x x x
6.25
6.25 m
x x x x x x x x x x x x x x x
6.25 m
Alternative Layout.
100 meters
P
mainline
50 meters
lateral
x x x x x x x x x x x x x x x
6.25
6.25 m
x x x x x x x x x x x x x x x
6.25 m
Alternative Layout.
100 meters
P
50 meters
Maximum Available GPM (Maximum Safe GPM)
Pipe Size Steel Pipe Copper Pipe PVC Pipe PE (poly) Tube PEX (CTS) Tube
Source: http://www.irrigationtutorials.com/sprinkler03.htm