0% found this document useful (0 votes)
38 views5 pages

FT1000 Dishwasher Spec Sheet F40657 (10-18)

The document details the specifications and features of the Hobart FT1000 Electric Flight-Type Dishwashing Machine, including its water usage, digital controls, and various operational features. It also outlines the machine's compliance with EPA standards and includes options and accessories available for purchase. Additionally, the document provides dimensional information and installation notes for the machine.

Uploaded by

Luizz Aguiñaga
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
38 views5 pages

FT1000 Dishwasher Spec Sheet F40657 (10-18)

The document details the specifications and features of the Hobart FT1000 Electric Flight-Type Dishwashing Machine, including its water usage, digital controls, and various operational features. It also outlines the machine's compliance with EPA standards and includes options and accessories available for purchase. Additionally, the document provides dimensional information and installation notes for the machine.

Uploaded by

Luizz Aguiñaga
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

DISHWASHERS

COMMERCIAL
Project_____________________________________________________________________
AIA #_________________________________ SIS #_________________________________
Item #_______________________________ Quantity_________ C.S.I. Section 114000

FT1000 ELECTRIC STANDARD FEATURES

FT SERIES – FT1000
++ Left to Right or Right to Left direction
Flight-Type Dishwashing Machine
++ Pumped rinse system (pressure gauge not required)
++ Water usage 58 gph
++ Digital controls with machine diagnostics
++ Low temperature alert
++ Hinged insulated cabinet-style doors
++ 31" access on prewash, power wash and power rinse
­chambers; 20" access on dual rinse and ASR chambers
++ Start and stop switches at both ends
++ Doors open indicator
++ Drains open indicator
++ Door interlocks
++ 31⁄2 H.P. prewash, 4 H.P. power wash and power rinse pump
motors, all TEFC
++ Capless auto clean wash arms
++ Easy to remove stainless steel scrap pans and baskets

ELECTRIC
LA Research Report M660004 ++ 30" wide conveyor belt
Complies with EPA Reduction of Lead in Drinking ++ Dual rinse
Water Act 2014 ++ Automatic soil removal system (ASR)
Meets requirements of ASSE Standard No. 1004 ++ Auto clean
++ Auto delime
SPECIFIER STATEMENT ++ Ventless technology
The specified machine shall be a Hobart Ventless ++ Energy recovery
flight type dish machine, 58 gallons of final rinse ++ Front and rear panels
consumption per hour, with dual rinse, hinged & ++ Variable speed conveyor
insulated doors, 30" wide conveyor belt, ­sliding
++ Electric booster heater
wash arms without caps, & microprocessor con-
trols with ventless technology, auto clean, auto ++ Configurable drain to load or unload
delime, energy recovery and automatic soil ++ Blower dryer
removal system (ASR), blower dryer, water soft- ++ Advansys water treatment system
ener.
OPTIONS & ACCESSORIES (Available at extra cost)
❑❑ Insulated split, vertical slide-up doors
❑❑ Multiple conveyor choices
❑❑ Factory mounted circuit breakers
❑❑ Correctional packages
❑❑ Flanged feet
❑❑ Water hammer arrestor/PRV (installed by others)
❑❑ Drain water tempering kit (installed by others)

Approved by______________________________________ Date___________ Approved by______________________________________ Date___________

Printed in U.S.A. HOBART • 701 S Ridge Avenue, Troy, OH 45374 • 1-888-4HOBART • www.hobartcorp.com F40657 (10/18) Page 1 of 5
FT1000 ELECTRIC
Flight-Type Dishwashing Machine
(Left to Right)

P2 60"
P1 52"
P3 4 3/4"

P2
P3 P1
HEAT
18 3/4" PUMP
27 3/4" 23 3/4"

37 1/2"
55 11/16"

E1 63 3/8"
E4
E2
E5
E3
E6
9 15/16"
SEE DETAIL “A-A”
P3 160 1/16"
E3 E2 E1 11 13/16"
NOTE: STRAINER PANS REQUIRE 35"
TO BE REMOVED. EXTRA CLEARANCE E6 E5 E4
SHOULD BE PROVIDED.
Top View Left to Right

OVER FRAME "A"


3 15/16" 8' 7/16" 10 7/8"
35 7/16" 25 9/16"
LOAD "B" 45 5/16"
10 3/8"
5 3/4" 23 3/4"
35 7/16"
35 9/16" 35 7/16" SEE NOTE (b)
HEAT
25 9/16" PUMP BLOWER
DRYER

ASR PRE- POWER POWER DUAL FNL 89 3/8"


LOAD WASH WASH RINSE RNS RNS UNLOAD
END END 81 7/8"

62 3/4"

36 1/2" DIRECTION OF OPERATION 37 5/8"

6"

FLOOR LINE 76 7/8"


Front View Left to Right
Note: Control box electrical connections – see page 5.

SEE NOTE (b) CEILING LINE


MODEL NO. “A” “B” “C” NOTE: REFER TO LATEST
FT1023 (7.5'-8'-7.5') 23' 3-1/2" 7' 8-1/2" 7' 6-1/2" EDITION OF NATIONAL
ELECTRICAL CODE AND 40 3/8" NOTE: 12" MINIMUM REQUIRED
FT1024 (8.5'-8'-7.5') 24' 3-1/4" 8' 8-1/4" 7' 6-1/2" LOCAL BUILDING CODES CLEARANCE TO CEILING
FOR PROPER CLEARANCE
FT1025 (9.5'-8'-7.5') 25' 3-3/32" 9' 8-3/32" 7' 6-1/2"
FT1025 (7.5'-8'-9') 24' 11-1/4" 7' 8-1/2" 9' 2-1/4"
FT1026 (8.5'-8'-9') 25' 11" 8' 8-1/4" 9' 2-1/4" 22" HIGH X 29-13/16"
NOTE: STRAINER PANS WIDE OPENING WILL
FT1027 (9.5'-8'-9') 26' 10-27/32" 9' 8-3/32" 9' 2-1/4" REQUIRE 35" TO HANDLE 18" X 26"
BE REMOVED. EXTRA BUN PANS
FT1027 (7.5'-8'-11') 26' 10-7/8" 7' 8-1/2" 11' 1-7/8"
CLEARANCE SHOULD
FT1028 (8.5'-8'-11') 27' 10-5/8" 8' 8-1/4" 11' 1-7/8" BE PROVIDED.
FT1029 (9.5'-8'-11') 28' 10-15/32" 9' 8-3/32" 11' 1-7/8"
35"
FT1030 (7.5'-8'-15') 30' 6-3/16" 7' 8-1/2" 14' 9-3/16"
FT1031 (8.5'-8'-15') 31' 5-15/16" 8' 8-1/4" 14' 9-3/16"
FT1032 (9.5'-8'-15') 32' 5-25/32" 9' 8-3/32" 14' 9-3/16" NOTE:
44 13/16" CLEARANCE FROM WALL
FT1032 (7.5'-8'-17') 32' 5-3/4" 7' 8-1/2" 16' 8-3/4" FLOOR LINE SEE NOTE (a) 18" MINIMUM REQUIRED
FT1033 (8.5'-8'-17') 33' 5-1/2" 8' 8-1/4" 16' 8-3/4" MODEL:
FT1000 ADVANSYS
FT1034 (9.5'-8'-17') 34' 5-11/32" 9' 8-3/32" 16' 8-3/4" ELECTRIC Back/Unload End
L-R OPERATION
00-949509
Note: Overall length of machine is Dimension “A” + 14-13/16" REV D

Page 2 of 5 CAD and/or Revit Files Available FT1000 ELECTRIC


FT1000 ELECTRIC
Flight-Type Dishwashing Machine
(Right to Left)

60" P2
52" P1
44 9/16" P3

P2
P1
HEAT
23 3/4" PUMP 18 3/4"
37 1/2"
P3
55 11/16"
63 3/8"
E1
E4
E2
E5
E3
E6
9 15/16"
SEE DETAIL “A-A” 160 1/16" P3
11 13/16" E1 E2 E3
E4 E5 E6

Top View Right to Left

7 7/8" OVER FRAME "A" 3 15/16"


UNLOAD "C" 8' 7/16" LOAD "B"
25 9/16" 35 7/16" 35 7/16" 35 7/16" 25 9/16"
43 5/16" 10 3/8" 3"
23 3/4" 5 3/4"
SEE NOTE (b)
HEAT
BLOWER/ PUMP
DRYER

89 3/8" FNL DUAL POWER POWER PRE- ASR


UNLOAD RNS RNS RINSE WASH WASH LOAD
END END
81 7/8"
62 3/4"
36 1/4"
DIRECTION OF OPERATION 36 1/2"

6"

FLOOR LINE
Front View Right to Left
Note: Control box electrical connections – see page 5.

MODEL NO. “A” “B” “C” SEE NOTE (b) CEILING LINE
NOTE: REFER TO LATEST
FT1023 (7.5'-8'-7.5') 23' 3-1/2" 7' 8-1/2" 7' 6-1/2" EDITION OF NATIONAL
ELECTRICAL CODE AND 40 3/8" NOTE: 12" MINIMUM REQUIRED
FT1024 (8.5'-8'-7.5') 24' 3-1/4" 8' 8-1/4" 7' 6-1/2" CLEARANCE TO CEILING
LOCAL BUILDING CODES
FT1025 (9.5'-8'-7.5') 25' 3-3/32" 9' 8-3/32" 7' 6-1/2" FOR PROPER CLEARANCE
FT1025 (7.5'-8'-9') 24' 11-1/4" 7' 8-1/2" 9' 2-1/4"
FT1026 (8.5'-8'-9') 25' 11" 8' 8-1/4" 9' 2-1/4" 22" HIGH X 29-13/16"
NOTE: STRAINER PANS WIDE OPENING WILL
FT1027 (9.5'-8'-9') 26' 10-27/32" 9' 8-3/32" 9' 2-1/4" REQUIRE 35" TO HANDLE 18" X 26"
FT1027 (7.5'-8'-11') 26' 10-7/8" 7' 8-1/2" 11' 1-7/8" BE REMOVED. EXTRA BUN PANS
CLEARANCE SHOULD
FT1028 (8.5'-8'-11') 27' 10-5/8" 8' 8-1/4" 11' 1-7/8" BE PROVIDED.
FT1029 (9.5'-8'-11') 28' 10-15/32" 9' 8-3/32" 11' 1-7/8"
35"
FT1030 (7.5'-8'-15') 30' 6-3/16" 7' 8-1/2" 14' 9-3/16"
FT1031 (8.5'-8'-15') 31' 5-15/16" 8' 8-1/4" 14' 9-3/16"
FT1032 (9.5'-8'-15') 32' 5-25/32" 9' 8-3/32" 14' 9-3/16" NOTE:
44 13/16"
FT1032 (7.5'-8'-17') 32' 5-3/4" 7' 8-1/2" 16' 8-3/4" FLOOR LINE SEE NOTE (a) CLEARANCE FROM WALL
18" MINIMUM REQUIRED
FT1033 (8.5'-8'-17') 33' 5-1/2" 8' 8-1/4" 16' 8-3/4" MODEL:
FT1000 ADVANSYS
FT1034 (9.5'-8'-17') 34' 5-11/32" 9' 8-3/32" 16' 8-3/4" ELECTRIC Back/Unload End
R-L OPERATION
00-949508
Note: Overall length of machine is Dimension “A” + 14-13/16" REV B

FT1000 ELECTRIC CAD and/or Revit Files Available Page 3 of 5


FT1000 ELECTRIC
Flight-Type Dishwashing Machine

LEGEND WARNING: Plumbing and electrical connections


Electrical Connections should be made by qualified personnel who will
Electric connection for 1TB with or without circuit observe all the ­applicable plumbing, sanitary,
E1
breakers. 79-1/8" AFF. safety codes and National Electrical Code.
Electric connection for 2TB without circuit breakers.
E2 General Notes:
79-1/8" AFF.
Electric connection for 3TB without circuit breakers. (a) The control box is attached to the center section and is
E3
79-1/8" AFF. rotated 90 degrees for shipping.
Electric connection for 4TB without circuit breakers. AFF = Above Finished Floor
E4
79-1/8" AFF. All dimensions taken from the floor line may increase 3-1/4"
Electric connection for 5TB without circuit breakers. with leg adjustment.
E5
79-1/8" AFF. For convenience when cleaning, customer should install
Electric connection for 2TB with circuit breakers. water tap near machine with 30 ft. of heavy duty hose with
E6
79-1/8" AFF. squeeze valve.
Plumbing Connections This drawing is supplied as a reference for connection
Common hot water connection (automatic fill) 110°F information only. It will not be utilized for manufacturing of
P1 water minimum, 1" FPT, 5-1/2" AFF. See notes (b) unit.
and (d). Electrical Warning:
Common cold water connection, 55°F minimum, Service wire temperature rating: 90°C minimum.
P2
1" FPT, 5-1/2" AFF. See notes (c) and (d).
Drain connection: May be drained to either end Plumbing Notes:
P3 of unit. Default location is drain to unload unless Required water hardness to be 3 grains or less per gallon for
otherwise indicated. 2" FPT. 7" AFF. best results.
Recommended building flowing hot water pressure to the
dishwasher is 40-45 PSI.
Recommended building flowing cold water to the dishwasher
SERVICE CONNECTIONS WITH CIRCUIT BREAKERS is 30-35 PSI. If cold water is less than 55°F, contact sales
(2) SERVICE CONNECTIONS AS SHOWN BELOW engineering.
Motors, Controls, Power Rinse & Booster Heat (TB1) Water hammer arrestor (meeting ASSE-1010 standard or
E1 equivalent) to be supplied (by others) in hot and cold supply
(1) Service Connection as Shown Below
lines at service connection.
Minimum Maximum
Rated
Voltage Supply Circuit Protective Ventilation Notes:
Amps
Ampacity Device
Heat pump and enclosure ships on separate skid to yield
208/60/3 149 200 200 81-7/8" door clearance.
240/60/3 142 200 200 Room ventilation is required to handle machine’s latent &
480/60/3 76 100 100 sensible heat.
B/D Blowers, Wash Tank Auxiliary Heat, (b) No facility ventilation within 24" of heat pump enclosure.
E6 Dual Rinse Heat & Heat Pump Compressor (2TB)
(1) Service Connection as Shown Below Advansys Notes:
Minimum Maximum Refer to Advansys technical report at www.hobartcorp.com
Rated
Voltage Supply Circuit Protective for guidance with local regulatory compliance.
Amps
Ampacity Device
Water Quality Required:
208/60/3 109.9 150 150
240/60/3 106.3 150 150 Total water hardness < 3 grains per gallon.

480/60/3 52.6 70 70 Total suspended solids (TSS) < 10 microns.

Heat Gain to Space (BTU/Hr.)


Latent Sensible
92,181 39,506

Page 4 of 5 FT1000 ELECTRIC


FT1000 ELECTRIC
Flight-Type Dishwashing Machine

SERVICE CONNECTIONS WITH CIRCUIT BREAKERS SPECIFICATIONS


(1) SINGLE POINT CONNECTION AS SHOWN BELOW Capacities
Motors, Controls, B/D Blowers, Wash Tank ­ Conveyor Speed (feet per minute). . . . . . . . . . . . . . . . 4.0 - 8.5
Auxiliary Heat, Dual Rinse Heat, Heat Pump Dishes per Hour. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14,316
E1
Compressor, ­Power Rinse & Booster Heat (TB1)
ASR Tank (U.S. gallons) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.2
(1) Single Point Connection as Shown Below
Pre-Wash Tank (U.S. gallons) . . . . . . . . . . . . . . . . . . . . . . . . . 40
Minimum Maximum
Rated Wash Tank (U.S. gallons) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Voltage Supply Circuit Protective
Amps Rinse Tank (U.S. gallons). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Ampacity Device
Dual Rinse Tank (U.S. gallons) . . . . . . . . . . . . . . . . . . . . . . . 7.2
480/60/3 127 175 175
Motor Horsepower
SERVICE CONNECTIONS W/O CIRCUIT BREAKERS Auto Soil Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1⁄4
(5) SERVICE CONNECTIONS AS SHOWN BELOW ASR Wash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1⁄3
Motors & Controls (1TB) Pre-Wash Tank. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31⁄2
E1 Wash Tank. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
(1) Service Connection as Shown Below
Minimum Maximum Rinse Tank. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Rated Dual Rinse Tank. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1⁄6
Voltage Supply Circuit Protective
Amps
Ampacity Device Final Rinse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1⁄2
208/60/3 41.4 60 60 Conveyor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1⁄3
480/60/3 25.4 35 35 Blower Dryer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Heat Pump Compressor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Electric Tank Heat, Power Rinse (2TB)
E2
(1) 26 KW Connection as Shown Below Water Consumption
Minimum Maximum U.S. Gallons per Hour (maximum use). . . . . . . . . . . . . . . . . . 58
Rated
Voltage Supply Circuit Protective U.S. Gallons per Minute . . . . . . . . . . . . . . . . . . . . . . . . . . 0.97
Amps
Ampacity Device
Heating
208/60/3 77.8 100 100 Tank Heat, Electric (kW regulated). . . Total tank heat - 52 kW
240/60/3 74.2 100 100 (Wash, Rinse, Dual Rinse)
480/60/3 37.0 50 50 Electric Booster (kW) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Heat Pump Compressor & Shipping Weight (approximate) . . . Varies by individual model
E3 Wash Tank Auxiliary Heat (3TB) (Consult your Hobart representative)
(1) 13 kW Connection as Shown Below Crated Dimensions. . . . . . . . . . . . . Varies by individual model
Minimum Maximum (Consult your Hobart representative)
Rated
Voltage Supply Circuit Protective
Amps
Ampacity Device
208/60/3 64.2 80 80 FT1000 Advansys Water Treatment System
240/60/3 62.4 80 80 Model Description
480/60/3 30.0 40 40 WS-80 Water Softener
Electric Tank Heat, Dual Rinse (4TB) PF-10-EHT Hi-Temp Filter Housing
E4
(1) 13 kW Connection as Shown Below
SD-510HT Sediment Filter Cartridge
Minimum Maximum
Rated
Voltage Supply Circuit Protective
Amps
Ampacity Device
208/60/3 45.7 60 60
CONTROL BOX ELECTRICAL CONNECTIONS
240/60/3 43.9 60 60
480/60/3 22.6 30 30
Electric Booster (5TB)
E5 E6 E5 E4 E3 E2 E1
(1) 9 kW Connection as Shown Below * *
Minimum Maximum * Note for installing electrician: Repunch holes E1 and E6 as
Rated
Voltage Supply Circuit Protective ­required to coincide with conduit requirements for machines
Amps with circuit breakers.
Ampacity Device
208/60/3 27.0 35 35 Detail “A-A”
240/60/3 25.8 35 35 (not to scale)
480/60/3 12.9 20 20
As continued product improvement is a policy of Hobart, specifications are subject to change without notice.

F40657 (10/18) Page 5 of 5 HOBART • 701 S Ridge Avenue, Troy, OH 45374 • 1-888-4HOBART • www.hobartcorp.com Printed in U.S.A.