The HEINE EN100® is a power source designed for medical instruments with 3.5V bulbs, requiring installation by trained medical staff. It includes safety information, assembly instructions, and technical specifications, along with a 5-year warranty covering defects under proper use. The device should be cleaned with 70% Isopropyl alcohol and disposed of as an electronic device according to local regulations.

Uploaded by

Digna Guzmán
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
7 views

en100

The HEINE EN100® is a power source designed for medical instruments with 3.5V bulbs, requiring installation by trained medical staff. It includes safety information, assembly instructions, and technical specifications, along with a 5-year warranty covering defects under proper use. The device should be cleaned with 70% Isopropyl alcohol and disposed of as an electronic device according to local regulations.

Uploaded by

Digna Guzmán
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

HEINE EN100 ®

HEINE Optotechnik GmbH & Co. KG


Kientalstr. 7 · 82211 Herrsching · Germany
Tel. +49 (0) 81 52 / 38 - 0
Fax +49 (0) 81 52 / 38 - 2 02
E-Mail: [email protected] · www.heine.com
med 4201 2014-05-09
ENGLISH
Instructions
HEINE EN100®
Read these instructions carefully before installing the HEINE EN100®
and keep them in a safe place for future reference.

In accordance with local


Applied Part BF regulations this product
should be disposed of as an
electronic device separately.
AC powered

Fuse *ETL CLASSIFIED


Conforms to ANSI/UL Std. 60601-1
4004478 Cert. to CAN/CSA Std. C22. 2.
NO.601.1

Contents
HEINE EN100®
Mounting plate
3 x fixing plugs U6
3 screws 4 x 35
Instrument locks with instruction leaflets S-277.04.06

Safety Information
Range of uses: The HEINE EN100® is designed exclusively for use as
a power source for medical instruments with 3.5V bulbs. The HEINE EN100® should
only be operated by trained medical staff.
General Safety: This unit needs no maintenance. Do not open the housing.
Repairs should only be carried out by qualified specialists. If the unit is damaged,
disconnect the mains cord immediately.
Safety in use: Ensure that the mains voltage specified on the instrument label
conforms to the local mains voltage. Do not use in the presence of an explosion
hazard or in a strong magnetic field.

Assembly and disassembly


Use only the mounting plate which is supplied with the EN100 for wall-mounting.
Please refer to the enclosed assembly instructions.
1. Hold the mounting plate horizontally in place where the unit should be
mounted and mark the holes to be drilled in the wall.
2. Drill a hole with a 6 mm drill at least 35 mm deep and insert the fixing plugs U6.
3. Screw the mounting-plate in with a suitable screwdriver.
4. Disconnect the mains cord from the unit and press into the 3 mounting pins
and down until it is firmly in place.
5. Check that all three mounting-pins have engaged.
To disassemble, disconnect the mains cord and push the unit up to remove it
from the mounting plate.

Connecting instruments
The HEINE EN100® cord handles are fitted with HEINE automatic connectors for
use with all similarly – equipped HEINE instruments.
– Hold the handle in one hand and insert the instrument connector into the
guides in the handle head.
– Press the instrument into the head until it clicks audibly into place.
– To remove the instrument, rotate the upper conical ring with thumb and index
finger to the right and, with the other hand, pull out the instrument.
– Instruments can be locked to prevent unauthorised removal by fitting the
instrument locks according to the instruction leaflet S-277.04.06.

Installation
– Connect the unit to the mains with the mains cord.
– Switch on, the green light operates.
– The handles switch on automatically when removed from the unit.
– The control ring on the handle can be rotated to select the desired brightness.
– Both handles can be simultaneously used independent of each other.

Cleaning
Disconnect the mains cord!
Clean and disinfect using 70% Isopropyl alcohol.

Technical specification
Voltage Fuse
Input: 100 V~, 50 /60 Hz 2 x 400 mA slow
(see nameplate) 120 V~, 50 /60 Hz* 2 x 400 mA slow
127 V~, 50 /60 Hz 2 x 400 mA slow
230 V~, 50 /60 Hz 2 x 200 mA slow
240 V~, 50 /60 Hz* 2 x 200 mA slow
Current consumption: 40 VA
Output voltage: 3.5 V
Output current: max. 800 mA
Protection class: I
Operation: Continuous with intermittent loading
Application part: Type BF
Dimensions: 285 x 205 x 85 mm
Weight: 1700 g
Ambient temperature: +10 °C to + 40 °C
Rel. Humidity: 10 to 75 %
Air pressure: 700 to 1060hPa
Protection class: IP X0
General Conditions of Warranty
Instead of the statutory warranty time period of 2 years, HEINE will grant a guarantee of 5 years
from the date of the consignment of the goods ex works, concerning its equipment (excluding dis-
posables, e.g. bulbs, single-use articles, and rechargeable batteries). Date of consignment means
that HEINE hands the goods over to the transport carrier, freight forwarder or any other person
designated by the Customer for the transport of the goods without loading the collecting vehicle.
The guarantee covers irreproachable workmanship, on condition of the proper use of the equip-
ment and the observation of the operating instructions. During the warranty- and guarantee
time period, errors and deficiencies arising on the equipment will be rectified free of charge,
in so far as such are evidenced by defective materials, processing and/or constructional errors.
Should buyer complain of a material deficiency during the warranty time period, then the onus
of proof is always to be on the orderer, that the product was defective already upon receipt of
the goods. The statutory warranty and the guarantee do not apply to loss or damage caused by
wear and tear, negligent use, the non-employment of original HEINE components and/or spares
(in particular bulbs, as these have been especially developed for HEINE instruments in accordance
with the following criterions: colour temperature, useful service life, safety, optical quality and
performance. The statutory warranty and the guarantee do not apply to interventions by persons
not authorised by HEINE or when the operating instructions are not observed by the customer.
Any modification of a HEINE product with parts or additional parts which do not conform to the
original HEINE specification will invalidate the warranty for the correct function of the product and
further invalidate any warranty claims which result from such a change or modification. Further
claims, in particular claims for replacement of loss or damage, which are experienced otherwise
than directly on the HEINE product itself, are hereby excluded.