master-mppt-solar-charge-controller-user-manual-v2-2
master-mppt-solar-charge-controller-user-manual-v2-2
Gel(GEL) 14.2 * N 13.8 * N 4. Example:If battery system is 48V,then N=4;If the cell's
voltage C=14.6V, then Constant voltage= 14.6*4=58.4V.
User (USER) C*N F*N
Table 1 (The MPPT controller can not wake up lithium ion battery.)
Strip Indicator Instruction
User can identify the controller current working status according to the flash rule of the light. (Red - ALARM,
2
4.Serial connection (string) of PV modules
The Table 4 is the quantity(N) of PV modules in series, for reference only.
Voc * N = PVinput < DC150V
System Voc<23V Voc<31V Voc<34V Voc<38V Voc<46V Voc<62V
Voltage Max. Best Max. Best Max. Best Max. Best Max. Best Max. Best
12V 6 2~3 4 2 4 2 3 1 3 1 2 1
24V 6 3 4 2 4 2 3 2 3 2 2 1
36V 6 4 4 3 4 3 3 2~3 3 2 2 1
48V 6 5 4 4 4 4 3 3 3 3 2 2
Figure 3
Make sure that the controller is installed and connected as above
Opening process:
Step 1: open the circuit breaker on the battery side(breaker), make sure that the controller is connected
with the battery (the LCD of the controller will display the content), and set the battery type.
Step 2: if you need to use the DC load output, then set the output control mode first, and then open the
DC output circuit breaker(breaker).
4
Step 3: open the circuit breaker on the input side of the solar panel PV(breaker), if the PV input voltage
is in the charge range of the controller, then the controller will enter the charging state.
Closing process: turn off the circuit breaker in turn:
Warning:
➢ If the system needs to connect the inverter, please connect the inverter directly
to the battery, and do not connect with the load end of the controller.
➢ When the controller is in the normal charge state, do not disconnect the battery
connection, otherwise the DC load may be damaged.Therefore, the damage to
the controller will not be within the warranty.
( Figure 5 )
8.Operation
5
8.1 Function key
Buttons Instruction
UP Page up and numerical increase
DOWN Page down and numerical reduction
ENTER Enter in
ESC Exit and save data
Table 6
8.2 Menu introduction(Table 7)
6
Addr Controller device address number setting
Lead-acid battery type(GEL,SEL,FLD,USER).
Type:USER 12V:Auto
Quantity of batteries in series.
Bulk Volt :
Cell’s constant charging voltage setting.
Float Volt :
Cell’s float charging voltage setting.
MaxChgCurr :
Max.Charging Current setting.
Over Volt :
Cell’s over-voltage protection voltage setting.
(Recovery) :
Cell’s over-voltage recovery voltage setting.
Under Volt :
Cell’s under-voltage protection voltage setting.
(Recovery) :
Bat Set Cell’s under-voltage recovery voltage setting.
Type:Li-ion Lithium ion battery type.
Full Volt : Full charging voltage setting.
NormalVolt : Nominal voltage setting.
MaxChgCurr : Max.Charging Current setting.
Over Volt : Over-voltage protection voltage setting.
(Recovery) : Over-voltage recovery voltage setting.
Under Volt : Under-voltage protection voltage setting.
(Recovery) : Under-voltage recovery voltage setting.
12/24/36/48V100A Controller type
Li BAT CHG SYS System voltage
Load : DC load output control mode after user set
Information
TOTAL : Total energy from this machine
Firmware : Firmware Ver.
Bat : Battery Type display
Table 8
7
10.Parameters(Table 9)
M48L80 M48L100 M48H80 M96H50
Start the charge voltage point Battery volt. + 3V Battery volt. + 10V Battery volt. + 20V
Low input voltage protection point Battery volt. + 2V Battery volt. + 5V Battery volt. + 10V
Battery types (Default Gel battery) Sealed(SEL), Gel(GEL), Flooded(FLD), User-defined(USE), Li-ion(Lit)
Charge method 3-Stage: CC(Constant current fast charging),CV(constant voltage charging),CF(float charging)