0% found this document useful (0 votes)
39 views28 pages

HPE FlexFabric 5945 Switch Series-A00047323enw

The HPE FlexFabric 5945 Switch Series is a high-density, ultra-low-latency switch family designed for large enterprise data centers and telecom customers, supporting up to 100 Gb per port. It features advanced capabilities such as NEBS certification, high-performance switching, and extensive support for virtualized environments. Key functionalities include enhanced manageability, security features, and resilient network architecture, making it suitable for various deployment scenarios.

Uploaded by

Juan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
39 views28 pages

HPE FlexFabric 5945 Switch Series-A00047323enw

The HPE FlexFabric 5945 Switch Series is a high-density, ultra-low-latency switch family designed for large enterprise data centers and telecom customers, supporting up to 100 Gb per port. It features advanced capabilities such as NEBS certification, high-performance switching, and extensive support for virtualized environments. Key functionalities include enhanced manageability, security features, and resilient network architecture, making it suitable for various deployment scenarios.

Uploaded by

Juan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 28

QuickSpecs HPE FlexFabric 5945 Switch Series

Overview

HPE FlexFabric 5945 Switch Series


HPE FlexFabric 5945 Switch Series is a family of high-density, ultra-low-latency, and ToR switches that is part of the HPE
FlexFabric solution (from the HPE Cloud-First Reference Architecture).

Ideally suited for deployment at the aggregation or server access layer of large enterprise data centers and telecom customers.
The HPE FlexFabric 5945 Switch Series is also powerful enough for deployment at the core layer of medium-sized enterprises.

With the increase in virtualized applications and server-to-server traffic, customers require spine and ToR switches that can meet
their throughput requirements. With the HPE FlexFabric 5945, data centers can now support up to 100 Gb per port, allowing high-
performance server connectivity and the capabilities to handle virtual environments. This is available in the low-latency HPE
FlexFabric 5945 Switch Series..

HPE FlexFabric 5945 48SFP28 8QSFP28 Switch (JQ074A)

HPE FlexFabric 5945 4-slot Switch (JQ076A)

Page 1
QuickSpecs HPE FlexFabric 5945 Switch Series

Overview

HPE FlexFabric 5945 2-slot Switch (JQ075A)

HPE FlexFabric 5945 32QSFP28 Switch (JQ077A)

Models
HPE FlexFabric 5945 48SFP28 8QSFP28 Switch JQ074A
HPE FlexFabric 5945 4-slot Switch JQ076A
HPE FlexFabric 5945 2-slot Switch JQ075A
HPE FlexFabric 5945 32QSFP28 Switch JQ077A

Key Features
• Cut-through with ultra low latency and wirespeed
• These switches are NEBS certified making them the ideal fit for telecom customers (applicable for JQ074A and JQ077A)
• New 32G/16G FC support for storage networking and ROCE V1/V2 for RDMA High-Performance computing
• VXLAN, EVPN, MPLS, VTEP, and OVSDB support for virtualized environments
• High-density 100GbE/40GbE/25GbE/10GbE spine/top-of-rack (ToR) connectivity
• PTP 1588V2 IEEE 802.1AS support for Boundary Clock, Transparent Clock, End to End/Peer to Peer Transparent Clock.
• IPv6 support with full L2 and L3 features
• Includes Distributed Resilient Network Interconnect (DRNI) that offers high availability and resiliency by combining
multiple physical switches into one virtual distributed-relay (DR) system.
• HPE IMC Orchestrator and Analyzer to simplify network management and operations
• Greater flexibility with two/four slot options for varying use cases such as MACsec encryption, high-performance DC leaf,
storage networking with FC and NVMe storage

Page 2
QuickSpecs HPE FlexFabric 5945 Switch Series

Standard Features

Quality of Service (QoS) Powerful QoS Features


• Flexible queue scheduling
Including Strict Priority (SP), WRR, WFQ, SP+WRR, SP+WDRR, SP+WFQ, configurable buffer, time range, queue shaping,
and CAR with 8 kbps granularity.
• Packet filtering and remarking
Packet filtering based on packet header fields from Layer 2 through Layer 4, including source MAC, destination MAC,
source IP (IPv4/IPv6), destination IP (IPv4/IPv6), port number, protocol type, and VLAN.

Data center Optimized


• Flexible high port density
HPE FlexFabric 5945 Switch Series enables scaling of the server edge, with 100GbE, 40GbE. 25GbE, and 10GbE spine
and leaf deployment. The HPE FlexFabric 5945 Switch Series solution includes a 48-port of 25 Gb with 8-port of , 32-port
of 100 Gb and 2 modular models of respectively 1RU / 2-slot and 2RU / 4-slot
• High-performance switching
Cut-through and nonblocking architecture delivers low latency (~ 1 microsecond for 100GbE) for very demanding
enterprise applications; the switch delivers high-performance switching capacity and wirespeed packet forwarding
• Higher scalability
HPE Intelligent Resilient Fabric (IRF) technology simplifies the architecture of server access networks; up to 10 HPE
FlexFabric 5945 switches can be combined to deliver unmatched scalability of virtualized access layer switches and flatter
2-tier networks using HPE IRF, which reduces cost and complexity
• Advanced modular operating system
Comware v7 software’s modular design and multiple processes bring native high stability, independent process
monitoring, and restart; the OS also allows individual software modules to be upgraded for higher availability and supports
enhanced serviceability functions such as hitless software upgrades with HPE IRF based in-service software upgrade
(ISSU)
• Reversible airflow
Enhanced for data center hot-cold aisle deployment with reversible airflow—for either front-to-back or back-to-front
airflow
• Redundant fans and power supplies
Internal redundant and hot-pluggable power supplies and dual fan trays enhance reliability and availability
• Lower OPEX and greener data center
Provides reversible airflow and advanced chassis power management
• Data Center Bridging (DCB) protocols
Provides support for IEEE 802.1Qbb Priority Flow Control (PFC), Data Center Bridging Exchange (DCBX), IEEE 802.1Qaz
Enhanced Transmission Selection (ETS), Explicit Congestion Notification (ECN) for converged FCoE, iSCSI, and RoCE
environments
• Jumbo frames
With frame sizes of up to 9416 bytes on 100GbE ports, high-performance remote backup and disaster recovery services
are enabled
• VXLAN hardware support
VXLAN L2/L3 gateway support for up to 4K tunnels
• Dynamic VXLAN configuration
OVSDB support for dynamic VXLAN configuration
• Security
MACsec encryption with swappable interface modules for enhanced security

Convergence
• LLDP-MED (Media Endpoint Discovery)
Defines a standard extension of LLDP that stores values for parameters such as QoS and VLAN to configure network
devices such as IP phones automatically

Page 3
QuickSpecs HPE FlexFabric 5945 Switch Series

Standard Features

Manageability
• HPE IMC Orchestrator and Analyzer
Offers enhanced network operations with orchestration, automation, and analytical capabilities. automated network
overlay/underlay deployment enhanced visibility with application telemetry
• AI-enabled network monitoring for faster troubleshooting
For more information, please refer to the HPE IMC Orchestrator and Analyzer datasheet
• Full-featured console
Provides complete control of the switch with a familiar CLI
• Troubleshooting
− Ingress and egress port monitoring: Enable network problem solving
− Traceroute and ping: Enable testing of network connectivity
• Multiple configuration files
Allow multiple configuration files to be stored to a flash image
• sFlow® (RFC 3176)
Provides wirespeed traffic accounting and monitoring
• SNMP v1, v2c, and v3
Facilitates centralized discovery, monitoring, and secure management of networking devices
• Out-of-band interface
Isolates management traffic from user data plane traffic for complete isolation and total reachability, no matter what
happens in the data plane
• Remote configuration and management
Delivered through a secure CLI over Telnet and SSH; role-based access control (RBAC) provides multiple levels of access;
configuration rollback and multiple configurations on the flash provide ease of operation; remote visibility is provided with
sFlow and SNMP v1/v2/v3, and is fully supported in HPE Intelligent Management Center (IMC)
• ISSU and hot patching
Provides hitless software upgrades with IRF-based ISSU and hitless patching of the modular operating system
• PTP and NTP support
Synchronizes timekeeping among distributed time servers and clients; support for Precision Time Protocol (PTP) and
Network Time Protocol (NTP)

Layer 2 switching
• Address Resolution Protocol (ARP)
Supports static, dynamic, and reverse ARP and ARP proxy
• IEEE 802.3x Flow Control
Provides intelligent congestion management via PAUSE frames
• Ethernet Link Aggregation
Provides IEEE 802.3ad Link Aggregation of up to 256 groups of 32 ports; support for LACP, LACP Local Forwarding First,
and LACP Short-time provide a fast, resilient environment that is ideal for the data center
• Spanning Tree Protocol
Supports STP (IEEE 802.1D), Rapid STP (RSTP, IEEE 802.1w), and Multiple STP (MSTP, IEEE 802.1s)
• VLAN support
Provides support for 4096 VLANs based on port
• IGMP support
Provides support for IGMP Snooping, fast-leave, and group policy; IPv6 IGMP Snooping provides L2 optimization of
multicast traffic
• DHCP support at L2
Provides full DHCP Snooping support for DHCP Snooping Option 82, DHCP Relay Option 82, DHCP Snooping Trust, and
DHCP Snooping Item Backup

Page 4
QuickSpecs HPE FlexFabric 5945 Switch Series

Standard Features

Resiliency and high availability


• IRF technology
Enables an HPE FlexFabric switch to deliver resilient, scalable, and secured data center networks for physical and
virtualized environments; groups up to 10 HPE FlexFabric 5945 switches in an HPE IRF configuration, allowing them to
be configured and managed as a single switch with a single IP address; simplifies ToR deployment and management,
reducing data center deployment and operating expenses
• IEEE 802.1w Rapid Convergence Spanning Tree Protocol
Increases network uptime through faster recovery from failed links
• IEEE 802.1s Multiple Spanning Tree
Provides high-link availability in multiple VLAN environments by allowing Multiple Spanning Trees
• Virtual Router Redundancy Protocol (VRRP)
Allows groups of two routers to back each other up dynamically to create highly available routed environments
• Hitless patch upgrades
Allows patches and new service features to be installed without restarting the equipment, increasing network uptime, and
facilitating maintenance
• Fast protocol convergence with standard-based failure detection-Bidirectional Forwarding Detection (BFD)
Enables link connectivity monitoring and reduces network convergence time for RIP, OSPF, BGP, IS-IS, VRRP, MPLS, and
IRF
• Device Link Detection Protocol (DLDP)
Monitors link connectivity and shuts down ports at both ends if unidirectional traffic is detected, preventing loops in STP-
based networks
• Graceful restart
Allows routers to indicate to others their capability to maintain a routing table during a temporary shutdown and
significantly reduces convergence times upon recovery; supports OSPF, BGP, and IS-IS

Layer 3 services
• Address Resolution Protocol
Determines the MAC address of another IP host in the same subnet; supports static ARPs; gratuitous ARP allows
detection of duplicate IP addresses; proxy ARP allows normal ARP operation between subnets or when subnets are
separated by a L2 network
• Dynamic Host Configuration Protocol
Simplifies the management of large IP networks and supports client and server; DHCP Relay enables DHCP operation
across subnets
• Operations, administration, and maintenance (OAM) support
Provides support for Connectivity Fault Management (IEEE 802.1AG) and Ethernet in the First Mile (IEEE 802.3AH);
provides additional monitoring that can be used for fast fault detection and recovery

Security
• Access control lists
Provides IP L3 filtering based on source/destination IP, address/subnet, and source/destination TCP/UDP port number
• RADIUS/TACACS+
Eases switch management security administration by using a password authentication server
• Secure shell
Encrypts all transmitted data for secure remote CLI access over IP networks
• IEEE 802.1X and RADIUS network logins
Controls port-based access for authentication and accountability
• Port security
• Allows access only to specified MAC addresses, which can be learned or specified by the administrator

Page 5
QuickSpecs HPE FlexFabric 5945 Switch Series

Standard Features

Layer 3 routing
• EVPN and EVPN-DCI
Can act as a VTEP, EVPN Gateway, or Border Gateway enabling virtual multipoint bridged connectivity between different
Layer 2 domains over an IP network
• VRRP and VRRP Extended
Allows quick failover of router ports
• Policy-based routing
Makes routing decisions based on policies set by the network administrator
• Equal-Cost Multipath (ECMP)
Enables multiple equal-cost links in a routing environment to increase link redundancy and scale bandwidth
• L3 IPv4 routing
Provides routing of IPv4 at media speed; supports static routes, RIP and RIPv2, OSPF, BGP, and IS-IS
• Open shortest path first
Delivers faster convergence; uses this link-state routing interior gateway protocol (IGP), which supports ECMP, NSSA, and
MD5 authentication for increased security and graceful restart for faster failure recovery
• Border Gateway Protocol 4 (BGP-4)
Delivers an implementation of the BGP utilizing path vectors; uses TCP for enhanced reliability for the route discovery
process; reduces bandwidth consumption by advertising only incremental updates; supports extensive policies for
increased flexibility; scales to very large networks
• Intermediate system to intermediate system (IS-IS)
Uses a path vector IGP, which is defined by the ISO organization for IS-IS routing and extended by IETF RFC 1195 to
operate in both TCP/IP and the OSI reference model (integrated IS-IS)
• Static IPv6 routing
Provides simple manually configured IPv6 routing
• Dual IP stack
Maintains separate stacks for IPv4 and IPv6 to ease the transition from an IPv4-only network to an IPv6-only network design
• Routing Information Protocol next generation (RIPng)
Extends RIPv2 to support IPv6 addressing
• OSPFv3
Provides OSPF support for IPv6
• BGP+
Extends BGP-4 to support Multiprotocol BGP (MBGP), including support for IPv6 addressing
• IS-IS for IPv6
Extends IS-IS to support IPv6 addressing
• IPv6 tunneling
Allows IPv6 packets to traverse IPv4-only networks by encapsulating the IPv6 packet into a standard IPv4 packet;
supports manually configured, 6 to 4, and intra-site automatic tunnel addressing protocol (ISATAP) tunnels; is an
important element for the transition from IPv4 to IPv6
• Policy routing
Allows custom filters for increased performance and security; supports ACLs, IP prefix, AS paths, community lists, and
aggregate policies
• Bidirectional Forwarding Detection (BFD)
Enables link connectivity monitoring and reduces network convergence time for RIP, OSPF, BGP, IS-IS, VRRP, MPLS, and
IRF
• Multicast Routing PIM dense and sparse modes
Provides robust support of multicast protocols
• Layer 3 IPv6 routing
Provides routing of IPv6 at media speed; supports static routing, RIPng, OSPFv3, BGP4+ for IPv6, and IS-ISv6.
• Storage Network
32/16/8/4/2G Fiber Channel, FCoE, NVMe over FC, ROCE V1/V2. VSAN and Zoning, single and multi-hop SAN network.

Page 6
QuickSpecs HPE FlexFabric 5945 Switch Series

Standard Features

Management
• USB support
− File copy: Allows users to copy switch files to and from a USB flash drive
• Multiple configuration files
Stores easily to the flash image
• SNMPv1, v2c, and v3
Facilitates centralized discovery, monitoring, and secure management of networking devices
• Out-of-band interface
Isolates management traffic from user data plane traffic for complete isolation and total reachability, no matter what
happens in the data plane
• Port mirroring
Enables traffic on a port to be simultaneously sent to a network analyzer for monitoring
• Remote configuration and management
Is available through a CLI
• IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
Advertises and receives management information from adjacent devices on a network, facilitating easy mapping by
network management applications
• sFlow (RFC 3176)
Provides scalable ASIC-based wirespeed network monitoring and accounting with no impact on network performance; this
allows network operators to gather a variety of sophisticated network statistics and information for capacity planning and
real-time network monitoring purposes
• Command authorization
Leverages RADIUS to link a custom list of CLI commands to an individual network administrator’s login; an audit trail
documents activity
• Dual flash images
Provides independent primary and secondary operating system files for backup while upgrading
• Command-line interface
Provides a secure, easy-to-use CLI for configuring the module via SSH or a switch console; provides direct real-time
session visibility
• Logging
Provides local and remote logging of events via SNMP (v2c and v3) and syslog; provides log throttling and log filtering to
reduce the number of log events generated
• Management interface control
Provides management access through a modem port and terminal interface, as well as in-band and out-of-band Ethernet
ports; provides access through terminal interface, Telnet, or SSH
• Industry-standard CLI with a hierarchical structure
Reduces training time and expenses, and increases productivity in multivendor installations
• Management security
Restricts access to critical configuration commands; offers multiple privilege levels with password protection; ACLs provide
Telnet and SNMP access; local and remote syslog capabilities allow logging of all access
• Information center
Provides a central repository for system and network information; aggregates all logs, traps, and debugging information
generated by the system and maintains them in order of severity; outputs the network information to multiple channels
based on user-defined rules
• Network management
HPE IMC centrally configures, updates, monitors, and troubleshoots
• Remote intelligent mirroring
Mirrors ingress/egress ACL-selected traffic from a switch port or VLAN to a local or remote switch port anywhere on the
network

Page 7
QuickSpecs HPE FlexFabric 5945 Switch Series

Standard Features

Additional information
• Green IT and power
Improves energy efficiency through the use of the latest advances in silicon development; shuts off unused ports and
utilizes variable-speed fans, reducing energy costs

Warranty and support


• 1-year warranty
See http://www.hpe.com/networking/warrantysummary for warranty and support information included with your
product purchase.
• Software releases
To find software for your product, refer to http://www.hpe.com/networking/support; for details on the software releases
available with your product purchase, refer to http://www.hpe.com/networking/warrantysummary

Page 8
QuickSpecs HPE FlexFabric 5945 Switch Series

Configuration Information

BTO Models
Standard Switch Enclosures
Rule # Description SKU
1, 2, 3, 4, 5, 6,HPE FlexFabric 5945 48SFP28 8QSFP28 Switch JQ074A
7, 8
• 48 SFP/SFP+/SFP28 ports (min=0 \ max=48)
• 8 QSFP+/QSFP28 ports (min=0 \ max=8)
• 3 SFP Management Port (min=0 \ max=3)
• 2 Power Supply Slots (Min 1 required)
• 5 Fan Tray Slots (Min 5 required)
• 1U - Height
1, 2, 5, 6 HPE FlexFabric 5945 2-slot Switch JQ075A
• 2 port expansion module slots
• 1 SFP Management Port (min=0 \ max=1)
• 2 QSFP+/QSFP28 (min=0 \ max=2)
• 2 Power Supply Slots (Min 1 required)
• 5 Fan Tray Slots (Min 5 required)
• 1U - Height
1, 2 HPE FlexFabric 5945 4-slot Switch JQ076A
• 4 port expansion module slots
• 3 SFP Management Port (min=0 \ max=3)
• 4 Power Supply Slots (Min 2 required)
• 2 Fan Tray Slots (Min 2 required)
• 2U - Height
1, 2, 5, 6, 7, 8 HPE FlexFabric 5945 32QSFP28 Switch JQ077A
• 32 QSFP+/QSFP28 ports (min=0 \ max=32)
• 3 SFP Management Port (min=0 \ max=3)
• 2 Power Supply Slots (Min 1 required)
• 5 Fan Tray Slots (Min 5 required)
• 1U - Height
Configuration Rules
Rule # Description SKU
1 The following SFP/SFP+ Transceivers install into this Switch's Management Ports and SFP+
Ports:
HPE X115 100M SFP LC FX Transceiver JD102B
HPE X110 100M SFP LC LX Transceiver JD120B
2 The following SFP Transceivers install into this switch's Management Port and SFP+ Ports:
HPE X120 1G SFP LC SX Transceiver JD118B
HPE X120 1G SFP LC LX Transceiver JD119B
HPE X120 1G SFP LC LH100 Transceiver JD103A
HPE X120 1G SFP RJ45 T Transceiver JD089B
3 The following SFP+ Transceivers install into this Switch:
HPE X130 10G SFP+ LC BiDi 10km-Uplink Transceiver JL737A
HPE X130 10G SFP+ LC BiDi 10km-Downlink Transceiver JL738A
HPE X130 10G SFP+ LC BiDi 40km-Uplink Transceiver JL739A
HPE X130 10G SFP+ LC BiDi 40km-Downlink Transceiver JL740A
HPE X130 10G SFP+ LC SR Transceiver JD092B
HPE X130 10G SFP+ LC LR Transceiver JD094B
HPE X2A0 10G SFP+ to SFP+ 7m Active Optical Cable JL290A
HPE X2A0 10G SFP+ to SFP+ 10m Active Optical Cable JL291A
HPE X2A0 10G SFP+ to SFP+ 20m Active Optical Cable JL292A
HPE FlexNetwork X240 10G SFP+ to SFP+ 0.65m Direct Attach Copper Cable JD095C

Page 9
QuickSpecs HPE FlexFabric 5945 Switch Series

Configuration Information

HPE FlexNetwork X240 10G SFP+ to SFP+ 1.2m Direct Attach Copper Cable JD096C
HPE FlexNetwork X240 10G SFP+ to SFP+ 3m Direct Attach Copper Cable JD097C
HPE FlexNetwork X240 10G SFP+ to SFP+ 5m Direct Attach Copper Cable JG081C
Rule # Description SKU
4 The following SFP28 Transceivers install into this Switch:
HPE X190 25G SFP28 LC SR 100m MM Transceiver JL293A
HPE 25G SFP28 LC LR 10km SMF Xcvr JL855A
HPE X240 25G SFP28 to SFP28 1m Direct Attach Copper Cable JL294A
HPE X240 25G SFP28 to SFP28 3m Direct Attach Copper Cable JL295A
HPE X240 25G SFP28 to SFP28 5m Direct Attach Copper Cable JL296A
HPE X2A0 25G SFP28 to SFP28 3m Active Optical Cable JH955A
HPE X2A0 25G SFP28 to SFP28 5m Active Optical Cable JH956A
HPE X2A0 25G SFP28 to SFP28 7m Active Optical Cable JL297A
HPE X2A0 25G SFP28 to SFP28 10m Active Optical Cable JL298A
HPE X2A0 25G SFP28 to SFP28 20m Active Optical Cable JL299A
5 The following QSFP+ Transceivers install into this Switch:
HPE X140 40G QSFP+ MPO SR4 Transceiver JG325B
HPE X140 40G QSFP+ MPO MM 850nm CSR4 300m Transceiver JG709A
HPE X140 40G QSFP+ LC BiDi 100m MM Transceiver JL251A
HPE X140 40G QSFP+ LC LR4 SM 10km 1310nm Transceiver JG661A
HPE X140 40G QSFP+ LC LR4L 2km SM Transceiver JL286A
HPE X2A0 40G QSFP+ to QSFP+ 7m Active Optical Cable JL287A
HPE X2A0 40G QSFP+ to QSFP+ 10m Active Optical Cable JL288A
HPE X2A0 40G QSFP+ to QSFP+ 20m Active Optical Cable JL289A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 1m Direct Attach Copper Cable JG326A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 3m Direct Attach Copper Cable JG327A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 5m Direct Attach Copper Cable JG328A
6 The following QSFP28 Transceivers install into this Switch:
HPE X150 100G QSFP28 MPO SR4 100m MM Transceiver JL274A
HPE X150 100G QSFP28 LC SWDM4 100m MM Transceiver JH419A
HPE X150 100G QSFP28 LC BiDi 100m MM Transceiver JQ344A
HPE X150 100G QSFP28 eSR4 300m MM Transceiver JH672A
HPE X150 100G QSFP28 MPO PSM4 500m SM Transceiver JH420A
HPE X150 100G QSFP28 LC LR4 10km SM Transceiver JL275A
HPE X150 100G QSFP28 CWDM4 2km SM Transceiver JH673A
HPE X2A0 100G QSFP28 to QSFP28 7m Active Optical Cable JL276A
HPE X2A0 100G QSFP28 to QSFP28 10m Active Optical Cable JL277A
HPE X2A0 100G QSFP28 to QSFP28 20m Active Optical Cable JL278A
HPE X240 100G QSFP28 to QSFP28 1m Direct Attach Copper Cable JL271A
HPE X240 100G QSFP28 to QSFP28 3m Direct Attach Copper Cable JL272A
HPE X240 100G QSFP28 to QSFP28 5m Direct Attach Copper Cable JL273A
Notes: Selection Form -
HPE Offering > DataCenter Networking > FlexFabric Switches - Access:
HPE FlexFabric 5945 Switch Series
7 The following QSFP28 Transceivers install into this Switch:
HPE X240 QSFP28 4xSFP28 1m Direct Attach Copper Cable JL282A
HPE X240 QSFP28 4xSFP28 3m Direct Attach Copper Cable JL283A
HPE X240 QSFP28 4xSFP28 5m Direct Attach Copper Cable JL284A
8 The following QSFP28 Transceivers install into this Switch:
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 1m Direct Attach Copper Splitter Cable JG329A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable JG330A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 5m Direct Attach Copper Splitter Cable JG331A

Page 10
QuickSpecs HPE FlexFabric 5945 Switch Series

Configuration Information

Rack Level Integration CTO Models


CTO Switch Chassis
Rule # Description SKU
1, 2, 3, 4, 5, 6,HPE FlexFabric 5945 48SFP28 8QSFP28 Switch JQ074A
7, 8
• 48 SFP/SFP+/SFP28 ports (min=0 \ max=48)
• 8 QSFP+/QSFP28 ports (min=0 \ max=8)
• 3 SFP Management Port (min=0 \ max=3)
• 2 Power Supply Slots (Min 1 required)
• 5 Fan Tray Slots (Min 5 required)
• 1U - Height
1, 2, 5, 6 HPE FlexFabric 5945 2-slot Switch JQ075A
• 2 port expansion module slots
• 1 SFP Management Port (min=0 \ max=1)
• 2 QSFP+/QSFP28 (min=0 \ max=2)
• 2 Power Supply Slots (Min 1 required)
• 5 Fan Tray Slots (Min 5 required)
• 1U - Height
1, 2 HPE FlexFabric 5945 4-slot Switch JQ076A
• 4 port expansion module slots
• 3 SFP Management Port (min=0 \ max=3)
• 4 Power Supply Slots (Min 2 required)
• 2 Fan Tray Slots (Min 2 required)
• 2U - Height
1, 2, 5, 6, 7, HPE FlexFabric 5945 32QSFP28 Switch JQ077A
8
• 32 QSFP+/QSFP28 ports (min=0 \ max=32)
• 3 SFP Management Port (min=0 \ max=3)
• 2 Power Supply Slots (Min 1 required)
• 5 Fan Tray Slots (Min 5 required)
• 1U - Height
Configuration Rules
Rule # Description SKU
1 The following SFP/SFP+ Transceivers install into this Switch's Management Ports and SFP+ Ports:
(Use #0D1 or #B01 if switch is CTO) - if applicable
HPE X115 100M SFP LC FX Transceiver JD102B
HPE X110 100M SFP LC LX Transceiver JD120B
2 The following SFP Transceivers install into this switch's Management Ports and SFP+ Ports:
(Use #0D1 or #B01 if switch is CTO) - if applicable
HPE X120 1G SFP LC SX Transceiver JD118B
HPE X120 1G SFP LC LX Transceiver JD119B
HPE X120 1G SFP LC LH100 Transceiver JD103A
HPE X120 1G SFP RJ45 T Transceiver JD089B
3 The following SFP+ Transceivers install into this Switch: (Use #0D1 or #B01 if switch is CTO) - if
applicable
HPE X130 10G SFP+ LC BiDi 10km-Uplink Transceiver JL737A
HPE X130 10G SFP+ LC BiDi 10km-Downlink Transceiver JL738A
HPE X130 10G SFP+ LC BiDi 40km-Uplink Transceiver JL739A
HPE X130 10G SFP+ LC BiDi 40km-Downlink Transceiver JL740A
HPE X130 10G SFP+ LC SR Transceiver JD092B
HPE X130 10G SFP+ LC LR Transceiver JD094B
HPE X2A0 10G SFP+ to SFP+ 7m Active Optical Cable JL290A

Page 11
QuickSpecs HPE FlexFabric 5945 Switch Series

Configuration Information

HPE X2A0 10G SFP+ to SFP+ 10m Active Optical Cable JL291A
HPE X2A0 10G SFP+ to SFP+ 20m Active Optical Cable JL292A
HPE FlexNetwork X240 10G SFP+ to SFP+ 0.65m Direct Attach Copper Cable JD095C
HPE FlexNetwork X240 10G SFP+ to SFP+ 1.2m Direct Attach Copper Cable JD096C
HPE FlexNetwork X240 10G SFP+ to SFP+ 3m Direct Attach Copper Cable JD097C
HPE FlexNetwork X240 10G SFP+ to SFP+ 5m Direct Attach Copper Cable JG081C
4 The following SFP28 Transceivers install into this Switch: (Use #0D1 or #B01 if switch is CTO) - if
applicable
HPE X190 25G SFP28 LC SR 100m MM Transceiver JL293A
HPE 25G SFP28 LC LR 10km SMF Xcvr JL855A
HPE X240 25G SFP28 to SFP28 1m Direct Attach Copper Cable JL294A
HPE X240 25G SFP28 to SFP28 3m Direct Attach Copper Cable JL295A
HPE X240 25G SFP28 to SFP28 5m Direct Attach Copper Cable JL296A
HPE X2A0 25G SFP28 to SFP28 3m Active Optical Cable JH955A
HPE X2A0 25G SFP28 to SFP28 5m Active Optical Cable JH956A
HPE X2A0 25G SFP28 to SFP28 7m Active Optical Cable JL297A
HPE X2A0 25G SFP28 to SFP28 10m Active Optical Cable JL298A
HPE X2A0 25G SFP28 to SFP28 20m Active Optical Cable JL299A
5 The following QSFP+ Transceivers install into this Switch: (Use #0D1 or #B01 if switch is CTO) - if
applicable
HPE X140 40G QSFP+ MPO SR4 Transceiver JG325B
HPE X140 40G QSFP+ MPO MM 850nm CSR4 300m Transceiver JG709A
HPE X140 40G QSFP+ LC BiDi 100m MM Transceiver JL251A
HPE X140 40G QSFP+ LC LR4 SM 10km 1310nm Transceiver JG661A
HPE X140 40G QSFP+ LC LR4L 2km SM Transceiver JL286A
HPE X140 40G QSFP+ LC ER4 40km SM Transceiver JL306A
HPE X2A0 40G QSFP+ to QSFP+ 7m Active Optical Cable JL287A
HPE X2A0 40G QSFP+ to QSFP+ 10m Active Optical Cable JL288A
HPE X2A0 40G QSFP+ to QSFP+ 20m Active Optical Cable JL289A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 1m Direct Attach Copper Cable JG326A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 3m Direct Attach Copper Cable JG327A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 5m Direct Attach Copper Cable JG328A
6 The following QSFP28 Transceivers install into this Switch: (Use #0D1 or #B01 if switch is CTO) -
if applicable
HPE X150 100G QSFP28 MPO SR4 100m MM Transceiver JL274A
HPE X150 100G QSFP28 LC SWDM4 100m MM Transceiver JH419A
HPE X150 100G QSFP28 LC BiDi 100m MM Transceiver JQ344A
HPE X150 100G QSFP28 eSR4 300m MM Transceiver JH672A
HPE X150 100G QSFP28 MPO PSM4 500m SM Transceiver JH420A
HPE X150 100G QSFP28 LC LR4 10km SM Transceiver JL275A
HPE X150 100G QSFP28 CWDM4 2km SM Transceiver JH673A
HPE X2A0 100G QSFP28 to QSFP28 7m Active Optical Cable JL276A
HPE X2A0 100G QSFP28 to QSFP28 10m Active Optical Cable JL277A
HPE X2A0 100G QSFP28 to QSFP28 20m Active Optical Cable JL278A
HPE X240 100G QSFP28 to QSFP28 1m Direct Attach Copper Cable JL271A
HPE X240 100G QSFP28 to QSFP28 3m Direct Attach Copper Cable JL272A
HPE X240 100G QSFP28 to QSFP28 5m Direct Attach Copper Cable JL273A
7 If HPE CTO Switch Chassis is selected for Rack Level Integration, Then the Switch needs to
integrate (with #0D1) to the Rack.
Notes: Clic UNB - If an option is ordered with #0D1/#B01, then the switch must have #0D1 option.

Page 12
QuickSpecs HPE FlexFabric 5945 Switch Series

Configuration Information

Switch Options
Enter the following menu selections as integrated to the CTO Model X server above if order is factory built.
Rule # Description SKU
Modules
(JQ076A) System (std 0 // max 4) User Selection (min 1 // max 4)
1, 2, 7, 8, 11, HPE 5930 24-port SFP+ and 2-port QSFP+ Module JH180A
12, 15
• 24 1G/10G SFP/SFP+ ports (min=0 \ max=24)
• 2 40G QSFP+ ports (min=0 \ max=2)
1, 2, 7, 8, 11, HPE 5930 24-port SFP+ and 2-port QSFP+ with MACsec Module JH181A
12, 15
• 24 1G/10G SFP/SFP+ ports (min=0 \ max=24)
• 2 40G QSFP+ ports (min=0 \ max=2)
2, 8, 11 HPE 5930 24-port 10GBASE-T and 2-port QSFP+ with MACsec Module JH182A
• 24 1/10GBase-T ports
• 2 40G QSFP+ ports (min=0 \ max=2)
2, 8, 11 HPE 5930 8-port QSFP+ Module JH183A
• 8 40G QSFP+ ports (min=0 \ max=8)
1,7, 12, 14, HPE FlexFabric 16-Port 16/32G FC Converged port interface module JL865A
16, 18
• 16 Converged 10G/25G SFP+/SFP28 16/32Gb FC ports (min=0 \ max=16)
1, 2, 7, 8, 11, HPE 5930 24-port Converged Port and 2-port QSFP+ Module JH184A
12, 13, 15,
17
• 24 Converged 1G/10G SFP/SFP+ 8G FC ports (min=0 \ max=24)
• 2 40G QSFP+ ports (min=0 \ max=2)
Rule # Description SKU
3, 8, 11 HPE 5950 16-port QSFP+ Module JH405A
• 16 40G QSFP+ ports (min=0 \ max=16)
Notes: 4x10GbE Splitter Cables are not supported
2, 8, 9, 11 HPE 5950 8-port QSFP28 Module JH406A
• 8 40G/100G QSFP+/QSFP28 ports (min=0 \ max=8)
1, 2, 4, 7, 8, HPE FlexFabric 5950 24-port SFP28 and 2-port QSFP28 Module JH450A
9, 10, 11, 12,
15
• 24 10G/25G SFP+/SFP28 ports (min=0 \ max=24) (Default)
• 2 40G/100G QSFP+/QSFP28 ports (min=0 \ max=2)
HPE FlexFabric 5950 8-port QSFP28 MACsec Module JH957A
2, 9, 11 • 8 40G/100G QSFP+/QSFP28 ports (min=0 \ max=8)
Configuration Rules
Rule # Description SKU
1 The following Transceivers install into this Module's SFP+ Ports: (Use #0D1 or #B01 if switch is
CTO) - if applicable
HPE X130 10G SFP+ LC BiDi 10km-Uplink Transceiver JL737A
HPE X130 10G SFP+ LC BiDi 10km-Downlink Transceiver JL738A
HPE X130 10G SFP+ LC BiDi 40km-Uplink Transceiver JL739A
HPE X130 10G SFP+ LC BiDi 40km-Downlink Transceiver JL740A
HPE X130 10G SFP+ LC SR Transceiver JD092B
HPE X130 10G SFP+ LC LR Transceiver JD094B
HPE FlexNetwork X240 10G SFP+ to SFP+ 0.65m Direct Attach Copper Cable JD095C
HPE FlexNetwork X240 10G SFP+ to SFP+ 1.2m Direct Attach Copper Cable JD096C
HPE FlexNetwork X240 10G SFP+ to SFP+ 3m Direct Attach Copper Cable JD097C
HPE FlexNetwork X240 10G SFP+ to SFP+ 5m Direct Attach Copper Cable JG081C

Page 13
QuickSpecs HPE FlexFabric 5945 Switch Series

Configuration Information

Rule # Description SKU


2 The following 40G Transceivers install into this Module's QSFP+ Ports: (Use #0D1 or #B01 if
switch is CTO) - if applicable
HPE X140 40G QSFP+ LC LR4 SM 10km 1310nm Transceiver JG661A
HPE X140 40G QSFP+ LC BiDi 100m MM Transceiver JL251A
HPE X140 40G QSFP+ MPO SR4 Transceiver JG325B
HPE X140 40G QSFP+ MPO MM 850nm CSR4 300m Transceiver JG709A
HPE X140 40G QSFP+ LC LR4L 2km SM Transceiver JL286A
HPE X140 40G QSFP+ LC ER4 40km SM Transceiver JL306A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 1m Direct Attach Copper Cable JG326A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 3m Direct Attach Copper Cable JG327A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 5m Direct Attach Copper Cable JG328A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 1m Direct Attach Copper Splitter Cable JG329A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable JG330A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 5m Direct Attach Copper Splitter Cable JG331A
3 The following 40G Transceivers install into this Module's QSFP+ Ports: (Use #0D1 or #B01 if
switch is CTO) - if applicable
HPE X140 40G QSFP+ LC LR4 SM 10km 1310nm Transceiver JG661A
HPE X140 40G QSFP+ LC BiDi 100m MM Transceiver JL251A
HPE X140 40G QSFP+ MPO SR4 Transceiver JG325B
HPE X140 40G QSFP+ MPO MM 850nm CSR4 300m Transceiver JG709A
HPE X140 40G QSFP+ LC LR4L 2km SM Transceiver JL286A
HPE X140 40G QSFP+ LC ER4 40km SM Transceiver JL306A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 1m Direct Attach Copper Cable JG326A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 3m Direct Attach Copper Cable JG327A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 5m Direct Attach Copper Cable JG328A
7 The following 10G Transceivers install into this Module's SFP+ Ports: (Use #0D1 or #B01 if switch
is CTO) - if applicable
HPE X2A0 10G SFP+ to SFP+ 7m Active Optical Cable JL290A
HPE X2A0 10G SFP+ to SFP+ 10m Active Optical Cable JL291A
HPE X2A0 10G SFP+ to SFP+ 20m Active Optical Cable JL292A
8 The following 40G Transceivers install into this Module's QSFP+ Ports: (Use #0D1 or #B01 if
switch is CTO) - if applicable
HPE X2A0 40G QSFP+ to QSFP+ 7m Active Optical Cable JL287A
HPE X2A0 40G QSFP+ to QSFP+ 10m Active Optical Cable JL288A
HPE X2A0 40G QSFP+ to QSFP+ 20m Active Optical Cable JL289A
9 The following 100G Transceivers install into this Module's QSFP28 Ports: (Use #0D1 or #B01 if
switch is CTO) - if applicable
HPE X150 100G QSFP28 MPO SR4 100m MM Transceiver JL274A
HPE X150 100G QSFP28 LC SWDM4 100m MM Transceiver JH419A
HPE X150 100G QSFP28 LC BiDi 100m MM Transceiver JQ344A
HPE X150 100G QSFP28 eSR4 300m MM Transceiver JH672A
HPE X150 100G QSFP28 LC LR4 10km SM Transceiver JL275A
HPE X150 100G QSFP28 MPO PSM4 500m SM Transceiver JH420A
HPE X150 100G QSFP28 CWDM4 2km SM Transceiver JH673A
HPE X2A0 100G QSFP28 to QSFP28 7m Active Optical Cable JL276A
HPE X2A0 100G QSFP28 to QSFP28 10m Active Optical Cable JL277A
HPE X2A0 100G QSFP28 to QSFP28 20m Active Optical Cable JL278A
HPE X240 100G QSFP28 to QSFP28 1m Direct Attach Copper Cable JL271A
HPE X240 100G QSFP28 to QSFP28 3m Direct Attach Copper Cable JL272A
HPE X240 100G QSFP28 to QSFP28 5m Direct Attach Copper Cable JL273A
HPE X240 QSFP28 4xSFP28 1m Direct Attach Copper Cable JL282A
HPE X240 QSFP28 4xSFP28 3m Direct Attach Copper Cable JL283A

Page 14
QuickSpecs HPE FlexFabric 5945 Switch Series

Configuration Information

10 The following SFP28 Transceivers install into this Module's SFP28 Ports: (Use #0D1 or #B01 if
switch is CTO) - if applicable
HPE X190 25G SFP28 LC SR 100m MM Transceiver JL293A
HPE 25G SFP28 LC LR 10km SMF Xcvr JL855A
HPE X240 25G SFP28 to SFP28 1m Direct Attach Copper Cable JL294A
HPE X240 25G SFP28 to SFP28 3m Direct Attach Copper Cable JL295A
HPE X240 25G SFP28 to SFP28 5m Direct Attach Copper Cable JL296A
HPE X2A0 25G SFP28 to SFP28 3m Active Optical Cable JH955A
HPE X2A0 25G SFP28 to SFP28 5m Active Optical Cable JH956A
HPE X2A0 25G SFP28 to SFP28 7m Active Optical Cable JL297A
HPE X2A0 25G SFP28 to SFP28 10m Active Optical Cable JL298A
HPE X2A0 25G SFP28 to SFP28 20m Active Optical Cable JL299A
11 The following 40G Transceiver installs into this Module's QSFP+ Ports with PHY: (Use #0D1 or
#B01 if switch is CTO) - if applicable
HPE X140 40G QSFP+ LC ER4 40km SM Transceiver JL306A
12 The following 10G Transceiver installs into this Module's SFP+ Ports: (Use #0D1 or #B01 if
switch is CTO) - if applicable
HPE X130 10G SFP+ LC LH 80km Transceiver JG915A
HPE X130 10G SFP+ LC ER 40km Transceiver JG234A
13 Fibre channel support is 8Gb/4Gb/2Gb on any of the 24 converged ports of the JH184A Module.
Note that a maximum of 8Gb FC is supported regardless of the FC optics used.
14 Fibre channel support is 8Gb/16Gb/32Gb on any of the 16 converged ports of the JL865A
Module. Note that a maximum of 32Gb FC is supported regardless of the FC optics used.
15 The following Transceivers install into this Module's (SFP28) Ports: (Use #0D1 or #B01 if switch
is CTO) - if applicable
HPE X120 1G SFP LC SX Transceiver JD118B
HPE X120 1G SFP LC LX Transceiver JD119B
HPE X120 1G SFP RJ45 T Transceiver JD089B
HPE X120 1G SFP LC LH100 Transceiver JD103A
16 The following Transceivers install into this Module's (SFP28) Ports: (Use 0D1 or B01 if switch is
CTO) - if applicable
HPE 32Gb SFP28 Short Wave Commercial Temperature Transceiver P9H30A
HPE 16Gb SFP+ Short Wave 1-pack Commercial Transceiver E7Y10A
HPE 16Gb FC/10GbE 100m SR SFP+ Transceiver H6Z42A
HPE 8Gb Short Wave Fibre Channel SFP+ 1 Pack Transceiver AJ718A
HPE 32Gb SFP28 Short Wave 1-pack Pull Tab Optical Transceiver Q2P62A
17 The following Transceivers install into this Module's (SFP28) Ports: (Use 0D1 or B01 if switch is
CTO) - if applicable
HPE 16Gb SFP+ Short Wave 1-pack Commercial Transceiver E7Y10A
HPE 16Gb FC/10GbE 100m SR SFP+ Transceiver H6Z42A
HPE 8Gb Short Wave Fibre Channel SFP+ 1 Pack Transceiver AJ718A
18 The following SFP28 Transceivers install into this Module's SFP28 Ports: (Use 0D1 or B01 if
switch is CTO) - if applicable
HPE X190 25G SFP28 LC SR 100m MM Transceiver JL293A
Transceivers
Rule # Description SKU
SFP Transceivers
HPE X115 100M SFP LC FX Transceiver JD102B
HPE X110 100M SFP LC LX Transceiver JD120B
HPE X120 1G SFP RJ45 T Transceiver JD089B
HPE X120 1G SFP LC SX Transceiver JD118B
HPE X120 1G SFP LC LX Transceiver JD119B
HPE X120 1G SFP LC LH100 Transceiver JD103A

Page 15
QuickSpecs HPE FlexFabric 5945 Switch Series

Configuration Information

Notes: ­ 1G transceivers are supported in all Management Ports as well as SFP Ports, SFP+ Ports and
SFP28 Ports.
­ 100M Transceivers are supported ONLY in SFP or Management Ports, not in any SFP+ or
SFP28 ports.
SFP+ Transceivers
HPE X130 10G SFP+ LC BiDi 10km-Uplink Transceiver JL737A
HPE X130 10G SFP+ LC BiDi 10km-Downlink Transceiver JL738A
HPE X130 10G SFP+ LC BiDi 40km-Uplink Transceiver JL739A
HPE X130 10G SFP+ LC BiDi 40km-Downlink Transceiver JL740A
HPE X130 10G SFP+ LC SR Transceiver JD092B
HPE X130 10G SFP+ LC LR Transceiver JD094B
HPE X130 10G SFP+ LC ER 40km Transceiver JG234A
HPE X130 10G SFP+ LC LH 80km Transceiver JG915A
HPE X2A0 10G SFP+ to SFP+ 7m Active Optical Cable JL290A
HPE X2A0 10G SFP+ to SFP+ 10m Active Optical Cable JL291A
HPE X2A0 10G SFP+ to SFP+ 20m Active Optical Cable JL292A
HPE FlexNetwork X240 10G SFP+ to SFP+ 0.65m Direct Attach Copper Cable JD095C
HPE FlexNetwork X240 10G SFP+ to SFP+ 1.2m Direct Attach Copper Cable JD096C
HPE FlexNetwork X240 10G SFP+ to SFP+ 3m Direct Attach Copper Cable JD097C
HPE FlexNetwork X240 10G SFP+ to SFP+ 5m Direct Attach Copper Cable JG081C
Rule # Description SKU
SFP28 Transceivers
HPE X190 25G SFP28 LC SR 100m MM Transceiver JL293A
HPE 25G SFP28 LC LR 10km SMF Xcvr JL855A
HPE X240 25G SFP28 to SFP28 1m Direct Attach Copper Cable JL294A
HPE X240 25G SFP28 to SFP28 3m Direct Attach Copper Cable JL295A
HPE X240 25G SFP28 to SFP28 5m Direct Attach Copper Cable JL296A
HPE X2A0 25G SFP28 to SFP28 3m Active Optical Cable JH955A
HPE X2A0 25G SFP28 to SFP28 5m Active Optical Cable JH956A
HPE X2A0 25G SFP28 to SFP28 7m Active Optical Cable JL297A
HPE X2A0 25G SFP28 to SFP28 10m Active Optical Cable JL298A
HPE X2A0 25G SFP28 to SFP28 20m Active Optical Cable JL299A
FC SFP+ Transceivers
HPE 32Gb SFP28 Short Wave Commercial Temperature Transceiver P9H30A
HPE 16Gb SFP+ Short Wave 1-pack Commercial Transceiver E7Y10A
HPE 16Gb FC/10GbE 100m SR SFP+ Transceiver H6Z42A
HPE 8Gb Short Wave Fibre Channel SFP+ 1 Pack Transceiver AJ718A
HPE 32Gb SFP28 Short Wave 1-pack Pull Tab Optical Transceiver Q2P62A
QSFP+ Transceivers
HPE X140 40G QSFP+ MPO SR4 Transceiver JG325B
HPE X140 40G QSFP+ MPO MM 850nm CSR4 300m Transceiver JG709A
HPE X140 40G QSFP+ LC BiDi 100m MM Transceiver JL251A
HPE X140 40G QSFP+ LC LR4 SM 10km 1310nm Transceiver JG661A
HPE X140 40G QSFP+ LC LR4L 2km SM Transceiver JL286A
HPE X140 40G QSFP+ LC ER4 40km SM Transceiver JL306A
HPE X2A0 40G QSFP+ to QSFP+ 7m Active Optical Cable JL287A
HPE X2A0 40G QSFP+ to QSFP+ 10m Active Optical Cable JL288A
HPE X2A0 40G QSFP+ to QSFP+ 20m Active Optical Cable JL289A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 1m Direct Attach Copper Cable JG326A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 3m Direct Attach Copper Cable JG327A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 5m Direct Attach Copper Cable JG328A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 1m Direct Attach Copper Splitter Cable JG329A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable JG330A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 5m Direct Attach Copper Splitter Cable JG331A

Page 16
QuickSpecs HPE FlexFabric 5945 Switch Series

Configuration Information

QSFP28 Transceivers
HPE X150 100G QSFP28 MPO SR4 100m MM Transceiver JL274A
HPE X150 100G QSFP28 LC SWDM4 100m MM Transceiver JH419A
HPE X150 100G QSFP28 LC BiDi 100m MM Transceiver JQ344A
HPE X150 100G QSFP28 eSR4 300m MM Transceiver JH672A
HPE X150 100G QSFP28 MPO PSM4 500m SM Transceiver JH420A
HPE X150 100G QSFP28 LC LR4 10km SM Transceiver JL275A
HPE X150 100G QSFP28 CWDM4 2km SM Transceiver JH673A
HPE X2A0 100G QSFP28 to QSFP28 7m Active Optical Cable JL276A
HPE X2A0 100G QSFP28 to QSFP28 10m Active Optical Cable JL277A
HPE X2A0 100G QSFP28 to QSFP28 20m Active Optical Cable JL278A
HPE X240 100G QSFP28 to QSFP28 1m Direct Attach Copper Cable JL271A
HPE X240 100G QSFP28 to QSFP28 3m Direct Attach Copper Cable JL272A
HPE X240 100G QSFP28 to QSFP28 5m Direct Attach Copper Cable JL273A
HPE X240 QSFP28 4xSFP28 1m Direct Attach Copper Cable JL282A
HPE X240 QSFP28 4xSFP28 3m Direct Attach Copper Cable JL283A
HPE X240 QSFP28 4xSFP28 5m Direct Attach Copper Cable JL284A
Internal Power Supplies
(JQ074A, JQ075A and JQ077A) System (std 0 // max 2) User Selection (min 1 // max 2)
(JQ076A) System (std 0 // max 4) User Selection (min 2 // max 4)
1, 2, 3 HPE 58x0AF 650W AC Power Supply JC680A
• includes 1 x c13, 650w
HPE 58x0AF 650W AC Power Supply PDU Cable NA/JP/TW JC680A#B2B
• C15 PDU Jumper Cord (NA/MX/TW/JP)
HPE 58x0AF 650W AC Power Supply PDU Cable ROW JC680A#B2C
• C15 PDU Jumper Cord (ROW)
HPE A58x0AF 650W AC Power Supply JC680A#AC3
• No Localized Power Cord Selected
1, 3 HPE FlexFabric Switch 650W 48V Hot Plug NEBS-compliant DC Power Supply JH336A
• includes 1 x c13, 650w
Configuration Rules
Rule # Description
1 PSU's cannot be mixed in the same switch enclosure
2 Localization (Wall Power Cord) required on orders without #B2B, #B2C, and #AC3 (PDU Power
Cord) . (See Localization Menu)
REMARK: When Switches/Routers are Factory Racked, Then #B2B, or #B2C should be the
Defaulted Power Cable option on the Switches/Routers.
3 Must be ordered in multiples of 2 if configuring with JQ076A
Notes: ­ Drop down under power supply should offer the following options and results:
­ Switch/Router to PDU Power Cord - #B2B in NA, Mexico, Taiwan, and Japan or #B2C ROW.
(Watson Default B2B or B2C for Rack Level CTO)
­ Switch/Router/Power Supply to Wall Power Cord - Localized Option (Watson Default for BTO
and Box Level CTO)
­ No Power Cord - #AC3 Option
Fan Trays
(JQ074A, JQ075A and JQ077A) System (std 0 // max 5) User Selection (min 5 // max 5)
(JQ076A) System (std 0 // max 2) User Selection (min 2 // max 2)
Rule # Description SKU
1, 2 HPE X712 Back (Power Side) to Front (Port Side) Airflow High Volume 2 Fan Tray JH389A
1, 2 HPE X711 Front (Port Side) to Back (Power Side) Airflow High Volume 2 Fan Tray JH388A
1, 3 HPE 5930 4-slot Back (Power Side) to Front (Port Side) Airflow Fan Tray JH185A
1, 3 HPE 5930 4-slot Front (Port Side) to Back (Power Side) Airflow Fan Tray JH186A
Configuration Rules

Page 17
QuickSpecs HPE FlexFabric 5945 Switch Series

Configuration Information

1 Fan Trays cannot be mixed in the same switch enclosure


2 This fan tray is supported on:
HPE FlexFabric 5945 48SFP28 8QSFP28 Switch JQ074A
HPE FlexFabric 5945 2-slot Switch JQ075A
HPE FlexFabric 5945 32QSFP28 Switch JQ077A
3 This fan tray is supported on:
HPE FlexFabric 5945 4-slot Switch JQ076A
Notes: ­ If there is any empty space below the switch (JQ075A) in a rack when using Back to Front
Fan Tray, JH389A, the rack will receive an Air Plenum kit that takes up 1U of additional space
in the rack. The Air Plenum kit is not required on fully configured racks. The Air Plenum Kit is
a non-saleable SKU, and is brought in automatically for CTO Factory Rack Level Integration.
­ If there is any empty space below the switch (JQ076A) in a rack when using Back to Front
Fan Tray, JH185A, the rack will receive an Air Plenum kit that takes up 1U of additional space
in the rack. The Air Plenum kit is not required on fully configured racks. The Air Plenum Kit is
a non-saleable SKU, and is brought in automatically for CTO Factory Rack Level Integration.
Software
Orchestrator
Rule# Description SKU
1, 2 HPE IMC Orchestrator Base E-LTU JL849AAE
1, 3 HPE IMC Orchestrator Analyzer Add-on E-LTU JL850AAE
1, 4 HPE IMC Orchestrator Network Node Add-on E-LTU JL851AAE
1, 3 HPE IMC Orchestrator Analyzer IP Host Add-on E-LTU JL852AAE
Configuration Rules
Rule # Description
1 When configuring 12900 Switch Chassis(JH262A or JL255A), this Orchestrator Service is available
when one of the following Type X MPUs is added:
HPE FlexFabric 12904E Type X Main Processing Unit JL844A
HPE FlexFabric 12900E Type X Main Processing Unit JL845A
2 IMC Orchestrator Base E-LTU sku must be Qty 1 per solution
3 If this analyzer E-LTU is selected, then Qty 1 must be added per solution.
Additionally, if this Analyzer E-LTU is selected, then IP Host E-LTU must match qty of desired
Hosts.
4 This Network Node Add-on E-LTU must match the switch qty in the solution

Page 18
QuickSpecs HPE FlexFabric 5945 Switch Series

Technical Specifications

HPE FlexFabric 5945 48SFP28 8QSFP28 Switch (JQ074A)


I/O ports and slots 48 x 25G SFP28 ports
8 x 100G QSFP28 ports
2 x 1G SFP ports
Supports 48 x 10/25GbE and 8 x 100GbE fixed ports, or up to 80 x 10GbE ports when using splitter
cables
Additional ports and slots 1 x console port
1 x mini USB port
1 x USB port
2 x out-of-band management ports (one fiber port and one copper port)
Power supplies 2 power supply slots
1 minimum power supply required (ordered separately)
Fan tray 5 fan tray slots
The customer must order fan trays, as they are not included with the switch. This system requires
same-direction airflow fan trays to function properly. The system should not be operated with less
than five fan trays for more than 24 hours. The system should not be operated without a fan tray for
more than two minutes. The system should not be operated outside of the temperature range of 32°F
(0°C) to 113°F (45°C). Failure to comply with these operating requirements may void the product
warranty.
Physical characteristics Dimensions 43.6 x 440 x 460 mm (1.72 x 17.32 x 18.11 in)
Weight 10.10 kg (22.27 lb) shipping weight
Full configuration weight 15 kg (33.07 lb)
Memory and processor 1 GB flash; packet buffer size: 32 MB, 8 GB SDRAM
Performance Latency < 1 μs (64-byte packets)
Throughput 2024 Mpps
Routing/Switching capacity 4 Tbps
Routing table size 324K entries (IPv4), 162K entries (IPv6)
MAC address table size 288K entries
Environment Operating temperature 32°F to 113°F (0°C to 45°C)
Operating relative humidity 5% to 95%, noncondensing
Acoustic Low-speed fan: 62.1 dB, high-speed fan: 77.9 dB
Electrical characteristics Frequency 50/60 Hz
Maximum heat dissipation 1381 BTU/hr (1458 kJ/hr)
Voltage 100 VAC to 240 VAC V rated
90 VAC to 264 VAC max

–40 VDC to –60 VDC rated


–40 VDC to –72 VDC max
Maximum power rating 650 W
Idle power 179 W
Notes: Idle power is the actual power consumption of the device with no ports connected.
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum
numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic,
all ports plugged in, and all modules populated
Safety UL 60950-1, CAN/CSA C22.2 No 60950-1, IEC 60950-1, EN 60950-1, AS/NZS 60950-1, FDA 21
CFR Subchapter J
Emissions FCC Part 15 (CFR 47) CLASS A, ICES-003 CLASS A, VCCI CLASS A, CISPR 32 CLASS A , EN 55032
CLASS A, AS/NZS CISPR32 CLASS A, EN 61000-3-2, EN 61000-3-3, ETSI EN 300 386
Immunity CISPR 24, EN 55024, ETSI EN 300 386
Management IMC; CLI; out-of-band management; SNMP Manager; Telnet; FTP
Notes: The customer must install a minimum of one power supply, as the device does not come with
one. The customer must install 5 fan kits, as the device does not come with one.

Page 19
QuickSpecs HPE FlexFabric 5945 Switch Series

Technical Specifications

Services Refer to the Hewlett Packard Enterprise website at: http://www.hpe.com/networking/services for
details on the service-level descriptions and product numbers. For details about services and
response times in your area, please contact your local Hewlett Packard Enterprise sales office.

HPE FlexFabric 5945 4-slot Switch (JQ076A)


I/O ports and slots 4 module slots
2 x 1G SFP ports
Type 1000BASE-LX
Supports up to a maximum of 96 x 10/25GbE and 8 x 100GbE ports, or up to 32 x 100GbE ports
Additional ports and slots 1 x console port
1 x mini USB port
1 x USB port
2 x out-of-band management ports (one fiber port and one copper port)
Power supplies 4 power supply slots
2 minimum power supplies required (ordered separately)
Fan tray 2 fan tray slots
The customer must order fan trays, as they are not included with the switch. This system requires two
same-direction airflow fan trays to function properly. The system should not be operated with only
one fan tray for more than 24 hours. The system should not be operated without a fan tray for more
than two minutes. The system should not be operated outside of the temperature range of 32°F
(0°C) to 113°F (45°C). Failure to comply with these operating requirements may void the product
warranty.
Physical characteristics Dimensions 88.1 x 440 x 660 mm (3.47 x 17.32 x 25.98 in) (2U height)
Weight 18.10 kg (39.90 lb) shipping weight
Full configuration weight 27 kg (59.52 lb)
Memory and processor 1 GB flash; packet buffer size: 32 MB, 8 GB SDRAM
Performance Latency < 1 μs (64-byte packets)
Throughput 2024 Mbpps
Routing/Switching capacity 6.4 Tbps
Routing table size 324K entries (IPv4), 162K entries (IPv6)
MAC address table size 288K entries
Environment Operating temperature 32°F to 113°F (0°C to 45°C)
Operating relative humidity 5% to 95%, noncondensing
Acoustic Low-speed fan: 70.8 dB, high-speed fan: 83.2dB
Electrical characteristics Frequency 50/60 Hz
Maximum heat dissipation 2348 BTU/hr (2478 kJ/hr)
Voltage 100 VAC to 240 VAC V rated, 90 VAC to 264 VAC max.., –40
VDC to –60 VDC rated
–40 VDC to –72 VDC max.
Maximum power rating 650 W
Idle power 185 W
Notes: Idle power is the actual power consumption of the device with no ports connected.
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum
numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic,
all ports plugged in, and all modules populated
Safety UL 60950-1, CAN/CSA C22.2 No 60950-1, IEC 60950-1, EN 60950-1, AS/NZS 60950-1, FDA 21
CFR Subchapter J
Emissions FCC Part 15 (CFR 47) CLASS A, ICES-003 CLASS A, VCCI CLASS A, CISPR 32 CLASS A , EN 55032
CLASS A, AS/NZS CISPR32 CLASS A, EN 61000-3-2, EN 61000-3-3, ETSI EN 300 386
Immunity CISPR 24, EN 55024, ETSI EN 300 386
Management IMC; CLI; out-of-band management; SNMP Manager; Telnet; FTP
Notes: The customer must install a minimum of two power supplies, as the device does not come
with one. The customer must install 2 fan kits, as the device does not come with one.

Page 20
QuickSpecs HPE FlexFabric 5945 Switch Series

Technical Specifications

Services Refer to the Hewlett Packard Enterprise website at: http://www.hpe.com/networking/services for
details on the service-level descriptions and product numbers. For details about services and
response times in your area, please contact your local Hewlett Packard Enterprise sales office.

HPE FlexFabric 5945 32QSFP28 Switch (JQ077A)


I/O ports and slots 32 x 100G QSFP28 ports
2 x 1G SFP ports
Additional ports and slots 1 x console port
1 x mini USB port
1 x USB port
2 x out-of-band management ports (one fiber port and one copper port)
Power supplies 2 power supply slots
1 minimum power supply required (ordered separately)
Fan tray 5 fan tray slots
The customer must order fan trays, as they are not included with the switch. This system requires
same-direction airflow fan trays to function properly. The system should not be operated with less
than five fan trays for more than 24 hours. The system should not be operated without a fan tray for
more than two minutes. The system should not be operated outside of the temperature range of 32°F
(0°C) to 113°F (45°C). Failure to comply with these operating requirements may void the product
warranty.
Physical characteristics Dimensions 43.6 x 440 x 460 mm (1.72 x 17.32 x 18.11 in)
Weight 10.4 kg (22.93 lb) shipping weight
Memory and processor 1 GB flash; packet buffer size: 32 MB, 8 GB SDRAM
Performance Latency < 1 μs (64-byte packets)
Throughput 2024 Mpps
Routing/Switching capacity 6.4 Tbps
Routing table size 324K entries (IPv4), 162K entries (IPv6)
MAC address table size 288K entries
Environment Operating temperature 32°F to 113°F (0°C to 45°C)
Operating relative humidity 5% to 95%, noncondensing
Acoustic Low-speed fan: 62.4 dB, high-speed fan: 78.1 dB
Electrical characteristics Frequency 50/60 Hz
Maximum heat dissipation 1283 BTU/hr (1458 kJ/hr)
Voltage 100 VAC to 240 VAC V rated
90 VAC to 264 VAC max

–40 VDC to –60 VDC rated


–40 VDC to –72 VDC max
Maximum power rating 650 W
Idle power 154 W
Notes: Idle power is the actual power consumption of the device with no ports connected.
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum
numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic,
all ports plugged in, and all modules populated
Safety UL 60950-1, CAN/CSA C22.2 No 60950-1, IEC 60950-1, EN 60950-1, AS/NZS 60950-1, FDA 21
CFR Subchapter J
Emissions FCC Part 15 (CFR 47) CLASS A, ICES-003 CLASS A, VCCI CLASS A, CISPR 32 CLASS A , EN 55032
CLASS A, AS/NZS CISPR32 CLASS A, EN 61000-3-2, EN 61000-3-3, ETSI EN 300 386
Immunity CISPR 24, EN 55024, ETSI EN 300 386
Management IMC; CLI; out-of-band management; SNMP Manager; Telnet; FTP
Notes: The customer must install a minimum of one power supply, as the device does not come
with one. The customer must install 5 fan kits, as the device does not come with one.

Page 21
QuickSpecs HPE FlexFabric 5945 Switch Series

Technical Specifications

Services Refer to the Hewlett Packard Enterprise website at: http://www.hpe.com/networking/services for
details on the service-level descriptions and product numbers. For details about services and
response times in your area, please contact your local Hewlett Packard Enterprise sales office.

HPE FlexFabric 5945 2-slot Switch (JQ075A)


I/O ports and slots 2 module slots
2 x 100G QSFP28 ports
Supports up to a maximum of 48 x 10/25GbE and 4 x 100GbE ports, or up to 16 x 100GbE ports
Additional ports and slots 1 x console port
1 x mini USB port
1 x USB port
2 x out-of-band management ports (one fiber port and one copper port)
Power supplies 2 power supply slots
1 minimum power supply required (ordered separately)
Fan tray 5 fan tray slots
The customer must order fan trays, as they are not included with the switch. This system requires
same-direction airflow fan trays to function properly. The system should not be operated with with
less than five fan trays for more than 24 hours. The system should not be operated without a fan tray
for more than two minutes. The system should not be operated outside of the temperature range of
32°F (0°C) to 113°F (45°C). Failure to comply with these operating requirements may void the
product warranty.
Physical characteristics Dimensions 44.2 x 440 x 660 mm (1.74 x 17.32 x 25.98 in.)
Weight 13.10 kg (28.88 lb) shipping weight
Memory and processor 1 GB flash; packet buffer size: 32 MB, 8 GB SDRAM
Performance Latency < 1 μs (64-byte packets)
Throughput 2024 Mbpps
Routing/Switching capacity 3.6 Tbps
Routing table size 324K entries (IPv4), 162K entries (IPv6)
MAC address table size 288K entries
Environment Operating temperature 32°F to 113°F (0°C to 45°C)
Operating relative humidity 5% to 95%, noncondensing
Acoustic Low-speed fan: 70.8 dB, high-speed fan: 83.2dB
Electrical characteristics Frequency 50/60 Hz
Maximum heat dissipation 1392 BTU/hr (1458 kJ/hr)
Voltage 100 VAC to 240 VAC V rated, 90 VAC to 264 VAC max.., –40
VDC to –60 VDC rated
–40 VDC to –72 VDC max.
Maximum power rating 650 W
Idle power 136 W
Notes: Idle power is the actual power consumption of the device with no ports connected.
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum
numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic,
all ports plugged in, and all modules populated
Safety UL 60950-1, CAN/CSA C22.2 No 60950-1, IEC 60950-1, EN 60950-1, AS/NZS 60950-1, FDA 21
CFR Subchapter J
Emissions FCC Part 15 (CFR 47) CLASS A, ICES-003 CLASS A, VCCI CLASS A, CISPR 32 CLASS A , EN 55032
CLASS A, AS/NZS CISPR32 CLASS A, EN 61000-3-2, EN 61000-3-3, ETSI EN 300 386
Immunity CISPR 24, EN 55024, ETSI EN 300 386
Management IMC; CLI; out-of-band management; SNMP Manager; Telnet; FTP
Notes: The customer must install a minimum of two power supplies, as the device does not come
with one. The customer must install five fan kits, as the device does not come with any.

Page 22
QuickSpecs HPE FlexFabric 5945 Switch Series

Technical Specifications

Services Refer to the Hewlett Packard Enterprise website at: http://www.hpe.com/networking/services for
details on the service-level descriptions and product numbers. For details about services and
response times in your area, please contact your local Hewlett Packard Enterprise sales office.
Standards and protocols
Applies to all products in series
• IEEE 802.1ad Q-in-Q
• IEEE 802.1AX-2008 Link Aggregation
• IEEE 802.1D MAC Bridges
• IEEE 802.1p Priority
• IEEE 802.1Q VLANs
• IEEE 802.1s Multiple Spanning Trees
• IEEE 802.1w Rapid Reconfiguration of Spanning Tree
• IEEE 802.3ad Link Aggregation Control Protocol (LACP)
• IEEE 802.3ae 10-Gigabit Ethernet
• IEEE 802.3ag Ethernet OAM
• IEEE 802.3ah Ethernet in First Mile over Point to Point Fiber—EFMF
• IEEE 802.3x Flow Control RFC 768 UDP
• RFC 783 TFTP Protocol (revision 2)
• RFC 791 IP
• RFC 792 ICMP
• RFC 793 TCP
• RFC 826 ARP
• RFC 854 Telnet
• RFC 856 Telnet
• RFC 868 Time Protocol
• RFC 896 Congestion Control in IP/TCP Internetworks
• RFC 950 Internet Standard Subnetting Procedure
• RFC 1027 Proxy ARP
• RFC 1058 RIPv1
• RFC 1091 Telnet Terminal-Type Option
• RFC 1141 Incremental updating of the internet checksum
• RFC 1142 OSI IS-IS Intra-domain Routing Protocol
• RFC 1191 Path MTU discovery
• RFC 1213 Management Information Base for Network Management of TCP/IP-based internet RFC 1253 (OSPF v2)
• RFC 1531 DHCP
• RFC 1533 DHCP Options and BOOTP Vendor Extensions
• RFC 1534 DHCP/BOOTP Interoperation
• RFC 1541 DHCP
• RFC 1542 Clarifications and Extensions for the Bootstrap Protocol
• RFC 1591 DNS (client only)
• RFC 1624 Incremental internet Checksum
• RFC 1723 RIP v2
• RFC 1812 IPv4 Routing
• RFC 2030 Simple Network Time Protocol (SNTP) v4
• RFC 2131 DHCP
• RFC 2236 IGMP Snooping
• RFC 2338 VRRP
• RFC 2453 RIPv2
• RFC 2581 TCP Congestion Control
• RFC 2644 Directed Broadcast Control

Page 23
QuickSpecs HPE FlexFabric 5945 Switch Series

Technical Specifications

• RFC 2767 Dual Stacks IPv4 & IPv6


• RFC 2865 RADIUS
• RFC 2868 RADIUS Attributes for Tunnel Protocol Support
• RFC 2890 Key and Sequence Number Extensions to GRE
• RFC 3046 DHCP Relay Agent Information Option
• RFC 3411 An Architecture for Describing Simple Network Management Protocol (SNMP) Management Frameworks
• RFC 3412 Message Processing and Dispatching for the Simple Network Management Protocol (SNMP)
• RFC 3413 SNMP Applications
• RFC 3416 Protocol Operations for SNMP
• RFC 3417 Transport Mappings for the SNMP
• RFC 3418 Management Information Base (MIB) for the SNMP
• RFC 3768 VRRP
• RFC 4250 The SSH) Protocol Assigned Numbers
• RFC 4251 The SSH Protocol Architecture
• RFC 4252 The SSH Authentication Protocol
• RFC 4253 The SSH Transport Layer Protocol
• RFC 4254 The SSH Connection Protocol
• RFC 4292 IP Forwarding Table MIB
• RFC 4293 Management Information Base for the Internet Protocol (IP)
• RFC 4364 BGP/MPLS IP Virtual Private Networks (VPNs)
• RFC 4419 Diffie-Hellman Group Exchange for the SSH Transport Layer Protocol
• RFC 4594 Configuration Guidelines for DiffServ Service Classes
• RFC 4601 Protocol Independent Multicast— Sparse Mode (PIM-SM): Protocol Specification (Revised)
• RFC 4604 Using Internet Group Management Protocol Version 3 (IGMPv3) and Multicast Listener Discovery Protocol
Version 2 (MLDv2) for Source-Specific Multicast
• RFC 4607 Source-Specific Multicast for IP
• RFC 4941 Privacy Extensions for Stateless Address Auto configuration in IPv6
• RFC 5340 OSPF for IPv6
• RFC 5905 NTP Version 4: Protocol and Algorithms Specification
• RFC 2929 RADIUS Support DS for RADIUS
Device Management
• RFC 1157 SNMPv1/v2c
• RFC 1305 NTPv3
• RFC 1591 DNS (client)
• RFC 1902 (SNMPv2)
• RFC 1908 (SNMP v1/2 Coexistence)
• RFC 2573 (SNMPv3 Applications)
• RFC 2576 (coexistence between SNMP V1, V2, V3)
• RFC 2819 RMON
• Multiple configuration files
• Multiple software images
• SSHv1/SSHv2 Secure Shell
• TACACS/TACACS+
IPv6
• RFC 2080 RIPng for IPv6
• RFC 2460 IPv6 Specification
• RFC 2461 IPv6 Neighbor Discovery
• RFC 2462 IPv6 Stateless Address Auto-configuration
• RFC 2463 ICMPv6

Page 24
QuickSpecs HPE FlexFabric 5945 Switch Series

Technical Specifications

• RFC 2464 Transmission of IPv6 over Ethernet Networks


• RFC 2473 Generic Packet Tunneling in IPv6
• RFC 2545 Use of MP-BGP-4 for IPv6
• RFC 2563 ICMPv6
• RFC 2711 IPv6 Router Alert Option
• RFC 2740 OSPFv3 for IPv6
• RFC 2767 Dual stacks IPv46 & IPv6
• RFC 3315 DHCPv6 (client and relay)
• RFC 3484 Default Address Selection for IPv6
• RFC 3810 Multicast Listener Discovery Version 2 (MLDv2) for IPv6
• RFC 4213 Basic Transition Mechanisms for IPv6 Hosts and Routers
• RFC 4291 IP Version 6 Addressing Architecture
• RFC 4443 ICMPv6
• RFC 4552 Authentication/Confidentiality for OSPFv3
• RFC 4862 IPv6 Stateless Address Auto-configuration
• RFC 5095 Deprecation of Type 0 Routing Headers in IPv6
BGP
• RFC 1163 BGP
• RFC 1771 BGPv4
• RFC 1997 BGP Communities Attribute
• RFC 2918 Route Refresh Capability
• RFC 3392 Capabilities Advertisement with BGP-4
• RFC 4271 A BGP 4 (BGP-4)
• RFC 4360 BGP Extended Communities Attribute
• RFC 4456 BGP Route Reflection: An Alternative to Full Mesh Internal BGP (IBGP)
• RFC 4760 Multiprotocol Extensions for BGP-4
• RFC 7432 BGP MPLS-Based Ethernet VPN
MIBs
• RFC 1213 MIB II
• RFC 1907 SNMPv2 MIB
• RFC 2571 SNMP Framework MIB
• RFC 2572 SNMP-MPD MIB
• RFC 2573 SNMP-Notification MIB
• RFC 2573 SNMP-Target MIB
• RFC 2574 SNMP USM MIB
• RFC 2737 Entity MIB (version 2)
• RFC 3414 SNMP-User based-SM MIB
• RFC 3415 SNMP-View based-ACM MIB
• LLDP-EXT-DOT1-MIB
• LLDP-EXT-DOT3-MIB
• LLDP-MIB
Network Management
• RFC 2580 Conformance Statements for SMIv2
• RFC 3164 BSD syslog Protocol

Page 25
QuickSpecs HPE FlexFabric 5945 Switch Series

Technical Specifications

QoS/CoS
• IEEE 802.1p (CoS)
• RFC 2475 DiffServ Architecture
• RFC 2597 DiffServ Assured Forwarding (AF)
• RFC 3247 Supplemental Information for the New Definition of the EF PHB (Expedited Forwarding Per-Hop Behavior)
• RFC 3260 New Terminology and Clarifications for DiffServ
OSPF
• RFC 1587 OSPF NSSA
• RFC 2328 OSPFv2
• RFC 3101 OSPF NSSA
• RFC 3137 OSPF Stub Router Advertisement
• RFC 3623 Graceful OSPF Restart
• RFC 4577 OSPF as the Provider/Customer Edge Protocol for BGP/MPLS IP Virtual Private Networks (VPNs)
• RFC 4811 OSPF Out-of-Band LSDB
• Resynchronization
• RFC 4812 OSPF Restart Signaling
• RFC 4813 OSPF Link-Local Signaling
Security
• RFC 1321 The MD5 Message-Digest Algorithm
• RFC 2818 HTTP Over TLS
• RFC 6192 Partial Support-Protecting the router control plane
• ACLs SSHv2

Page 26
QuickSpecs HPE FlexFabric 5945 Switch Series

Summary of Changes

Date Version History Action Description of Change


06-Mar-2023 Version 22 Changed Overview and Standard Features sections were updated.
21-Nov-2022 Version 21 Changed Configuration Information section was updated
15-Aug-2022 Version 20 Changed Overview section was updated.
07-Feb-2022 Version 19 Changed Standard Features and Configuration Information sections were updated.
New SKUs added in Configuration Information section.
06-Jul-2021 Version 18 Changed SKUs added in Related Options section.
12-Oct-2020 Version 17 Changed Related Options section was updated. MD
05-Oct-2020 Version 16 Changed Configuration Information section was updated.
10-Aug-2020 Version 15 Changed Configuration Information section was updated.
06-Jul-2020 Version 14 Changed Configuration Information section was updated.
04-May-2020 Version 13 Changed Configuration Information and Related Options sections were updated.
06-Apr-2020 Version 12 Changed Configuration Information section was updated.
18-Nov-2019 Version 10 Changed Configuration Information section was updated.
New SKUS were added.
03-Sep-2019 Version 9 Changed Configuration Information and Additional Options sections were updated.
Obsolete SKUs were removed.
New SKUs were added.
13-May-2019 Version 8 Changed Added JQ075A,and,JQ077A,
Multiple SKUs were added in Related Options
Overview, Standard Features and Technical specifications sections were
updated
02-Apr-2019 Version 7 Changed Configuration was updated. Compatibility rules were updated.
18-Feb-2019 Version 6 Changed Accessories updated
03-Dec-2018 Version 5 Changed Configuration and Technical Specifications updated.
01-Oct-2018 Version 4 Changed HPE Recommended Options section removed
04-Sep-2018 Version 3 Changed Technical Specifications and Configuration sections were updated.
09-Aug-2018 Version 2 Changed Technical Specifications section was updated.
06-Aug-2018 Version 1 New New QuickSpecs

Page 27
QuickSpecs HPE FlexFabric 5945 Switch Series

Copyright

Make the right purchase decision.


Contact our presales specialists.

Get update

© Copyright 2023 Hewlett Packard Enterprise Development L.P. The information contained herein is
subject to change without notice. The only warranties for Hewlett Packard Enterprise products and services
are set forth in the express warranty statements accompanying such products and services. Nothing herein
should be construed as constituting an additional warranty. Hewlett Packard Enterprise shall not be liable for
technical or editorial errors or omissions contained herein.

sFlow is a registered trademark of InMon Corp. All other third-party trademark(s) is/are property of their
respective owner(s).

To learn more, visit: http://www.hpe/networking

a00047323enw - 16266 - Worldwide - V22 - 06-March-2023

Page 28

You might also like