0% found this document useful (0 votes)
5 views

Sheet9

The document provides a detailed schedule of loads for the Main Distribution Panel (MDP) and associated lighting and distribution panels, including circuit numbers, load descriptions, switch counts, wire types, conduit types, and branch circuit protection details. It includes calculations for service entrance ampacity and demand factors for various lighting and outlet configurations. The total load for the lighting panel is 12,450 VA, while the distribution panels have respective loads of 85,917 VA and 36,446 VA.

Uploaded by

shbeldia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
5 views

Sheet9

The document provides a detailed schedule of loads for the Main Distribution Panel (MDP) and associated lighting and distribution panels, including circuit numbers, load descriptions, switch counts, wire types, conduit types, and branch circuit protection details. It includes calculations for service entrance ampacity and demand factors for various lighting and outlet configurations. The total load for the lighting panel is 12,450 VA, while the distribution panels have respective loads of 85,917 VA and 36,446 VA.

Uploaded by

shbeldia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

MAIN DISTRIBUTION PANEL (MDP) - SCHEDULE OF LOADS

CKT NO. LOAD DESCRIPTION NO. OF SWITCHES CONDUIT TYPE BRANCH CIRCUIT PROTECTION
VA V A NO., SIZE & TYPE OF WIRE
& SIZE
LIGHTING PANEL (LP) - SCHEDULE OF LOADS L.O. C.O. SA SAB SABC AT V P KAIC TYPE

CKT NO. LOAD DESCRIPTION NO. OF SWITCHES NO., SIZE & TYPE CONDUIT TYPE & BRANCH CIRCUIT PROTECTION 1 Lighting Panel (LP) 12450 230 54.13 2 - 14.0 mm² THHN PVC 32 mmØ 90 230 2 10 MCCB
VA V A
OF WIRE SIZE
L.O. C.O. SA SAB SABC AT V P KAIC TYPE
2 Distribution Panel A (DPA) 85917 230 313.552 2 - 250.0 mm² THHN PVC 100 mmØ 500 230 2 10 MCCB
1 9 Pin Light @ 25 W 225 230 0.98 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
9 Pin Light @ 25 W
2 275 230 1.20 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB 3 Distribution Panel B (DPB) 36446 230 120.652 2 - 60 mm² THHN PVC 50 mmØ 175 230 2 10 MCCB
1 Lighting Outlets @ 50 W
7 Lighting Outlets @ 50 W TOTAL 112310 230 488.304
3 425 230 1.85 2 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
3 Pin Light @ 25 W SERVICE ENTRANCE AMPACITY = 490.30 x 125% = 612.88 A
COMPUTATION @ 80% DEMAND FACTOR
4 10 Pin Light @ 25 W 250 230 1.09 1 2 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB USE: 2 - 250 mm2 THW WIRE IN 155 mm Ø RMC PIPE
(107710 + 25%(2300)(80%))/230 = 490.30 A
5 9 Pin Light @ 25 W 225 230 0.98 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB 1 - 700 AT, 230 V, 2P 10 KAIC MCCB FOR OVER CURRENT PROTECTION
6 9 Pin Light @ 25 W 225 230 0.98 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
7 8 Pin Light @ 25 W 200 230 0.87 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
8 10 Lighting Outlets @ 50 W 500 230 2.17 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
9 7 Pin Light @ 25 W 175 230 0.76 1 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
10 9 Pin Light @ 25 W 225 230 0.98 1 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
11
12
10 Pin Light @ 25 W
8 Pin Light @ 25 W
250
175
230
230
1.09
0.76
7
2 1
2
2
-
-
2.0
2.0
mm²
mm²
THHN
THHN
PVC
PVC
15
15
mmØ
mmØ
15
15
230
230
2
2
10
10
MCCB
MCCB
MDP SCHEDULE OF LOADS
13 10 Pin Light @ 25 W 250 230 1.09 2 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB SCALE: NTS
14 10 Pin Light @ 25 W 250 230 1.09 2 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
15 10 Pin Light @ 25 W 250 230 1.09 1 2 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
16 10 Lighting Outlets @ 50 W 500 230 2.17 2 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
17 8 Lamp Post @ 50 W 400 230 1.74 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
18 9 Lamp Post @ 50 W 450 230 1.74 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
19 6 lamp Post @ 50 W 300 230 1.30 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
20 SPARE 2300 230 10 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
21 SPARE 2300 230 10 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB DISTRIBUTION PANEL A (DPA) - SCHEDULE OF LOADS
22 SPARE 2300 230 10 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
TOTAL 12450 230 54.13 19 11 5 CKT NO. LOAD DESCRIPTION NO. OF SWITCHES BRANCH CIRCUIT PROTECTION
CONDUIT TYPE &
VA V A NO., SIZE & TYPE OF WIRE
SERVICE ENTRANCE AMPACITY = 55.18 x 125% = 68.98 A SIZE
COMPUTATION @ 80% DEMAND FACTOR L.O. C.O. SA SAB SABC AT V P KAIC TYPE
USE: 2 - 14 mm2 THHN WIRE IN 32 mm Ø PVC PIPE
IT = (54.13 + 0.8) + (0.25 + 0) = 55.18 A
1 - 90 AT, 240 V, 2P 10 KAIC MCCB FOR OVER CURRENT PROTECTION 1 10 CO @ 180 W 1800 230 7.83 2 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB

2 10 CO @ 180 W 1800 230 7.83 2 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
4 CO @ 180 W
3 2 WP @ 180 W 1260 230 5.48 2 - 3.5 mm² THHN PVC 20 mmØ 20 230 2 10 MCCB
1 EL @ 180 W
8 CO @ 180 W
4 1620 230 7.04 2 - 3.5 mm² THHN PVC 20 mmØ 20 230 2 10 MCCB
1 GFCI @ 180 W
5 10 CO @ 180 W 1800 230 7.83 2 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB

LP SCHEDULE OF LOADS 6 7 CO @ 180 W 1260 230 5.48 2 - 3.5 mm² THHN PVC 20 mmØ 20 230 2 10 MCCB
7 CO @ 180 W
SCALE: NTS 7
2 GFCI @ 180 W
1620 230 7.04 2 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB

8 8 CO @ 180 W 1440 230 6.26 2 - 3.5 mm² THHN PVC 20 mmØ 20 230 2 10 MCCB
9 CO @ 180 W
9 1800 230 7.83 2 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
1 WP @ 180 W
5 CO @ 180 W
DISTRIBUTION PANEL B (DPB) - SCHEDULE OF LOADS 10 3 WP @ 180 W 1800 230 7.83 2 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
2 GFCI @ 180 W
CKT NO. LOAD DESCRIPTION NO. OF SWITCHES BRANCH CIRCUIT PROTECTION 3 CO @ 180 W
NO., SIZE & TYPE OF CONDUIT TYPE & 11 900 230 3.91 2 - 3.5 mm² THHN PVC 20 mmØ 20 230 2 10 MCCB
VA V A 2 GFCI @ 180 W
WIRE SIZE
L.O. C.O. SA SAB SABC AT V P KAIC TYPE 12 1 CD - S.P.O. @ 3 kW 3000 230 13.043 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
1 8 Lighting Outlets @ 50 W 400 230 1.74 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
8 Pin Light @ 25 W 13 1 WM - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
2 200 230 0.87 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
3 10 Lighting Outlets @ 50 W 500 230 2.17 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB 14 1 WM - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
4 8 Pin Light @ 25 W 200 230 0.87 4 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
9 Pin Light @ 25 W 15 1 REF - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
5 225 230 0.98 2 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
6 10 Pin Light @ 25 W 250 230 1.09 2 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB 16 1 REF - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
7 9 Pin Light @ 25 W 225 230 0.98 2 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
17 1 REF - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
8 9 Pin Light @ 25 W 225 230 0.98 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
9 6 Pin Light @ 25 W 225 230 0.98 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB 18 1 REF - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
10 6 Lighting Outlets @ 50 W 300 230 1.30 2 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
19 1 ACU - S.P.O. @ 2 HP 2760 230 12 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
4 CO @ 180 W
11 1080 230 4.70 2 - 3.5 mm² THHN PVC 20 mmØ 20 230 2 10 MCCB
2 WP @ 180 W 20 1 ACU - S.P.O. @ 2 HP 2760 230 12 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
7 CO @ 180 W
12 1440 230 6.26 2 - 3.5 mm² THHN PVC 20 mmØ 20 230 2 10 MCCB
1 GFCI @ 180 W 21 1 ACU - S.P.O. @ 2 HP 2760 230 12 2 - 8.0 mm² THHN + 5.5 mm² THHN (G) PVC 32 mmØ 60 230 2 10 MCCB
7 CO @ 180 W
13 1440 230 6.26 2 - 3.5 mm² THHN PVC 20 mmØ 20 230 2 10 MCCB 22 1 ACU - S.P.O. @ 2 HP 2760 230 12 2 - 8.0 mm² THHN + 5.5 mm² THHN (G) PVC 32 mmØ 60 230 2 10 MCCB
1 GFCI @ 180 W
7 CO @ 180 W 23 1 ACU - S.P.O. @ 2.5 HP 3450 230 15 2 - 8.0 mm² THHN + 5.5 mm² THHN (G) PVC 32 mmØ 60 230 2 10 MCCB
14 1440 230 6.26 2 - 3.5 mm² THHN PVC 20 mmØ 20 230 2 10 MCCB
1 GFCI @ 180 W
15 4 WP @ 180 W 720 230 3.13 2 - 3.5 mm² THHN PVC 20 mmØ 20 230 2 10 MCCB 24 1 ACU - S.P.O. @ 2 HP 2760 230 12 2 - 8.0 mm² THHN + 5.5 mm² THHN (G) PVC 32 mmØ 60 230 2 10 MCCB
16 1 REF - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
25 1 WH - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
17 1 ACU - S.P.O. @ 2 HP 2760 230 12 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
18 1 ACU - S.P.O. @ 2 HP 2760 230 12 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB 26 1 WH - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB

19 1 ACU - S.P.O. @ 2 HP 2760 230 12 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
27 1 WH - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
20 1 WH - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
21 1 WH - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB 28 1 WH - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB

22 1 WH - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB 1 R,O - S.P.O. @ 8 kW 2 - 8.0 mm² THHN + 5.5 mm² THHN (G)
29 6400 230 27.826 PVC 32 mmØ 60 230 2 10 MCCB
23 SPARE 2300 230 10 20 230 2 10 MCCB
24 SPARE 2300 230 10 20 230 2 10 MCCB 30 1 MO - S.P.O. @ 3 kW 3000 230 13.043 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB

TOTAL 27750 230 120.653 13 5 2 31 1 DW - S.P.O. @ 3 kW 3000 230 13.043 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
SERVICE ENTRANCE AMPACITY = 133.7 x 125% = 167.13 A
COMPUTATION @ 80% DEMAND FACTOR
USE: 2 - 60 mm2 THHN WIRE IN 50 mm Ø PVC PIPE 32 1 WP - S.P.O. @ 2 HP 2760 230 12 2 - 8.0 mm² THHN + 5.5 mm² THHN (G) PVC 32 mmØ 60 230 2 10 MCCB
IT = (120.65 + 0.8) + (0.25 + 12) = 133.7 A
1 - 200AT, 230 V, 2P 10 KAIC MCCB FOR OVER CURRENT PROTECTION 33 SPARE 2300 230 10 20 230 2 10 MCCB
34 SPARE 2300 230 10 20 230 2 10 MCCB
TOTAL 72110 230 313.521
SERVICE ENTRANCE AMPACITY = 329.57 x 125% = 411.96 A
COMPUTATION @ 80% DEMAND FACTOR
USE: 2 - 250 mm2 THHN WIRE IN 100 mm Ø PVC PIPE

DPB SCHEDULE OF LOADS


IT = (313.52 + 0.8) + (0.25 + 15) = 329.57 A
1 - 500 AT, 230 V, 2P 10 KAIC MCCB FOR OVER CURRENT PROTECTION

SCALE: NTS

DPA SCHEDULE OF LOADS


SCALE: NTS

PRC NO.
CERTIFIED BY: VALID:
PROJECT TITLE: CHECKED AND APPROVED BY: SHEET CONTENT: SHEET NO.
OF
ENGR. CLINT KENNETH U. REDUCTO TIN:

9
MAIN DISTRIBUTION PANEL SCHEDULE OF LOADS
IN
TE

TE
TU

ELECTRICAL ENGINEER
TI

PROPOSED RESIDENTIAL BUILDING VINCE DIVINO ALINSOG


S

PTR NO. LIGHTING PANEL SCHEDULE OF LOADS


A
IN

TE
D

11
EL
CAPIZ STATE UNIVERSITY DISTRIBUTION PANEL A SCHEDULE OF LOADS
S

EC DATE: 08/28/2024
R
EE

TR
IC 1975 MAIN CAMPUS
IN

DISTRIBUTION PANEL B SCHEDULE OF LOADS


G

A
L
OWNER
EN

FUENTES DRIVE, ROXAS CITY ISSUED AT: CAPSU LOCATION: BRGY. DINGINAN, ROXAS CITY