CKT NO. LOAD DESCRIPTION NO. OF SWITCHES CONDUIT TYPE BRANCH CIRCUIT PROTECTION
VA V A NO., SIZE & TYPE OF WIRE
& SIZE
LIGHTING PANEL (LP) - SCHEDULE OF LOADS L.O. C.O. SA SAB SABC AT V P KAIC TYPE
CKT NO. LOAD DESCRIPTION NO. OF SWITCHES NO., SIZE & TYPE CONDUIT TYPE & BRANCH CIRCUIT PROTECTION 1 Lighting Panel (LP) 12450 230 54.13 2 - 14.0 mm² THHN PVC 32 mmØ 90 230 2 10 MCCB
VA V A
OF WIRE SIZE
L.O. C.O. SA SAB SABC AT V P KAIC TYPE
2 Distribution Panel A (DPA) 85917 230 313.552 2 - 250.0 mm² THHN PVC 100 mmØ 500 230 2 10 MCCB
1 9 Pin Light @ 25 W 225 230 0.98 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
9 Pin Light @ 25 W
2 275 230 1.20 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB 3 Distribution Panel B (DPB) 36446 230 120.652 2 - 60 mm² THHN PVC 50 mmØ 175 230 2 10 MCCB
1 Lighting Outlets @ 50 W
7 Lighting Outlets @ 50 W TOTAL 112310 230 488.304
3 425 230 1.85 2 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
3 Pin Light @ 25 W SERVICE ENTRANCE AMPACITY = 490.30 x 125% = 612.88 A
COMPUTATION @ 80% DEMAND FACTOR
4 10 Pin Light @ 25 W 250 230 1.09 1 2 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB USE: 2 - 250 mm2 THW WIRE IN 155 mm Ø RMC PIPE
(107710 + 25%(2300)(80%))/230 = 490.30 A
5 9 Pin Light @ 25 W 225 230 0.98 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB 1 - 700 AT, 230 V, 2P 10 KAIC MCCB FOR OVER CURRENT PROTECTION
6 9 Pin Light @ 25 W 225 230 0.98 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
7 8 Pin Light @ 25 W 200 230 0.87 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
8 10 Lighting Outlets @ 50 W 500 230 2.17 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
9 7 Pin Light @ 25 W 175 230 0.76 1 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
10 9 Pin Light @ 25 W 225 230 0.98 1 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
11
12
10 Pin Light @ 25 W
8 Pin Light @ 25 W
250
175
230
230
1.09
0.76
7
2 1
2
2
-
-
2.0
2.0
mm²
mm²
THHN
THHN
PVC
PVC
15
15
mmØ
mmØ
15
15
230
230
2
2
10
10
MCCB
MCCB
MDP SCHEDULE OF LOADS
13 10 Pin Light @ 25 W 250 230 1.09 2 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB SCALE: NTS
14 10 Pin Light @ 25 W 250 230 1.09 2 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
15 10 Pin Light @ 25 W 250 230 1.09 1 2 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
16 10 Lighting Outlets @ 50 W 500 230 2.17 2 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
17 8 Lamp Post @ 50 W 400 230 1.74 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
18 9 Lamp Post @ 50 W 450 230 1.74 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
19 6 lamp Post @ 50 W 300 230 1.30 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
20 SPARE 2300 230 10 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
21 SPARE 2300 230 10 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB DISTRIBUTION PANEL A (DPA) - SCHEDULE OF LOADS
22 SPARE 2300 230 10 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
TOTAL 12450 230 54.13 19 11 5 CKT NO. LOAD DESCRIPTION NO. OF SWITCHES BRANCH CIRCUIT PROTECTION
CONDUIT TYPE &
VA V A NO., SIZE & TYPE OF WIRE
SERVICE ENTRANCE AMPACITY = 55.18 x 125% = 68.98 A SIZE
COMPUTATION @ 80% DEMAND FACTOR L.O. C.O. SA SAB SABC AT V P KAIC TYPE
USE: 2 - 14 mm2 THHN WIRE IN 32 mm Ø PVC PIPE
IT = (54.13 + 0.8) + (0.25 + 0) = 55.18 A
1 - 90 AT, 240 V, 2P 10 KAIC MCCB FOR OVER CURRENT PROTECTION 1 10 CO @ 180 W 1800 230 7.83 2 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
2 10 CO @ 180 W 1800 230 7.83 2 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
4 CO @ 180 W
3 2 WP @ 180 W 1260 230 5.48 2 - 3.5 mm² THHN PVC 20 mmØ 20 230 2 10 MCCB
1 EL @ 180 W
8 CO @ 180 W
4 1620 230 7.04 2 - 3.5 mm² THHN PVC 20 mmØ 20 230 2 10 MCCB
1 GFCI @ 180 W
5 10 CO @ 180 W 1800 230 7.83 2 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
LP SCHEDULE OF LOADS 6 7 CO @ 180 W 1260 230 5.48 2 - 3.5 mm² THHN PVC 20 mmØ 20 230 2 10 MCCB
7 CO @ 180 W
SCALE: NTS 7
2 GFCI @ 180 W
1620 230 7.04 2 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
8 8 CO @ 180 W 1440 230 6.26 2 - 3.5 mm² THHN PVC 20 mmØ 20 230 2 10 MCCB
9 CO @ 180 W
9 1800 230 7.83 2 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
1 WP @ 180 W
5 CO @ 180 W
DISTRIBUTION PANEL B (DPB) - SCHEDULE OF LOADS 10 3 WP @ 180 W 1800 230 7.83 2 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
2 GFCI @ 180 W
CKT NO. LOAD DESCRIPTION NO. OF SWITCHES BRANCH CIRCUIT PROTECTION 3 CO @ 180 W
NO., SIZE & TYPE OF CONDUIT TYPE & 11 900 230 3.91 2 - 3.5 mm² THHN PVC 20 mmØ 20 230 2 10 MCCB
VA V A 2 GFCI @ 180 W
WIRE SIZE
L.O. C.O. SA SAB SABC AT V P KAIC TYPE 12 1 CD - S.P.O. @ 3 kW 3000 230 13.043 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
1 8 Lighting Outlets @ 50 W 400 230 1.74 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
8 Pin Light @ 25 W 13 1 WM - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
2 200 230 0.87 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
3 10 Lighting Outlets @ 50 W 500 230 2.17 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB 14 1 WM - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
4 8 Pin Light @ 25 W 200 230 0.87 4 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
9 Pin Light @ 25 W 15 1 REF - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
5 225 230 0.98 2 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
6 10 Pin Light @ 25 W 250 230 1.09 2 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB 16 1 REF - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
7 9 Pin Light @ 25 W 225 230 0.98 2 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
17 1 REF - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
8 9 Pin Light @ 25 W 225 230 0.98 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
9 6 Pin Light @ 25 W 225 230 0.98 1 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB 18 1 REF - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
10 6 Lighting Outlets @ 50 W 300 230 1.30 2 2 - 2.0 mm² THHN PVC 15 mmØ 15 230 2 10 MCCB
19 1 ACU - S.P.O. @ 2 HP 2760 230 12 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
4 CO @ 180 W
11 1080 230 4.70 2 - 3.5 mm² THHN PVC 20 mmØ 20 230 2 10 MCCB
2 WP @ 180 W 20 1 ACU - S.P.O. @ 2 HP 2760 230 12 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
7 CO @ 180 W
12 1440 230 6.26 2 - 3.5 mm² THHN PVC 20 mmØ 20 230 2 10 MCCB
1 GFCI @ 180 W 21 1 ACU - S.P.O. @ 2 HP 2760 230 12 2 - 8.0 mm² THHN + 5.5 mm² THHN (G) PVC 32 mmØ 60 230 2 10 MCCB
7 CO @ 180 W
13 1440 230 6.26 2 - 3.5 mm² THHN PVC 20 mmØ 20 230 2 10 MCCB 22 1 ACU - S.P.O. @ 2 HP 2760 230 12 2 - 8.0 mm² THHN + 5.5 mm² THHN (G) PVC 32 mmØ 60 230 2 10 MCCB
1 GFCI @ 180 W
7 CO @ 180 W 23 1 ACU - S.P.O. @ 2.5 HP 3450 230 15 2 - 8.0 mm² THHN + 5.5 mm² THHN (G) PVC 32 mmØ 60 230 2 10 MCCB
14 1440 230 6.26 2 - 3.5 mm² THHN PVC 20 mmØ 20 230 2 10 MCCB
1 GFCI @ 180 W
15 4 WP @ 180 W 720 230 3.13 2 - 3.5 mm² THHN PVC 20 mmØ 20 230 2 10 MCCB 24 1 ACU - S.P.O. @ 2 HP 2760 230 12 2 - 8.0 mm² THHN + 5.5 mm² THHN (G) PVC 32 mmØ 60 230 2 10 MCCB
16 1 REF - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
25 1 WH - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
17 1 ACU - S.P.O. @ 2 HP 2760 230 12 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
18 1 ACU - S.P.O. @ 2 HP 2760 230 12 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB 26 1 WH - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
19 1 ACU - S.P.O. @ 2 HP 2760 230 12 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
27 1 WH - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
20 1 WH - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
21 1 WH - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB 28 1 WH - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
22 1 WH - S.P.O. @ 1.5 kW 1500 230 6.522 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB 1 R,O - S.P.O. @ 8 kW 2 - 8.0 mm² THHN + 5.5 mm² THHN (G)
29 6400 230 27.826 PVC 32 mmØ 60 230 2 10 MCCB
23 SPARE 2300 230 10 20 230 2 10 MCCB
24 SPARE 2300 230 10 20 230 2 10 MCCB 30 1 MO - S.P.O. @ 3 kW 3000 230 13.043 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
TOTAL 27750 230 120.653 13 5 2 31 1 DW - S.P.O. @ 3 kW 3000 230 13.043 3 - 5.5 mm² THHN PVC 20 mmØ 30 230 2 10 MCCB
SERVICE ENTRANCE AMPACITY = 133.7 x 125% = 167.13 A
COMPUTATION @ 80% DEMAND FACTOR
USE: 2 - 60 mm2 THHN WIRE IN 50 mm Ø PVC PIPE 32 1 WP - S.P.O. @ 2 HP 2760 230 12 2 - 8.0 mm² THHN + 5.5 mm² THHN (G) PVC 32 mmØ 60 230 2 10 MCCB
IT = (120.65 + 0.8) + (0.25 + 12) = 133.7 A
1 - 200AT, 230 V, 2P 10 KAIC MCCB FOR OVER CURRENT PROTECTION 33 SPARE 2300 230 10 20 230 2 10 MCCB
34 SPARE 2300 230 10 20 230 2 10 MCCB
TOTAL 72110 230 313.521
SERVICE ENTRANCE AMPACITY = 329.57 x 125% = 411.96 A
COMPUTATION @ 80% DEMAND FACTOR
USE: 2 - 250 mm2 THHN WIRE IN 100 mm Ø PVC PIPE
SCALE: NTS
PRC NO.
CERTIFIED BY: VALID:
PROJECT TITLE: CHECKED AND APPROVED BY: SHEET CONTENT: SHEET NO.
OF
ENGR. CLINT KENNETH U. REDUCTO TIN:
9
MAIN DISTRIBUTION PANEL SCHEDULE OF LOADS
IN
TE
TE
TU
ELECTRICAL ENGINEER
TI
TE
D
11
EL
CAPIZ STATE UNIVERSITY DISTRIBUTION PANEL A SCHEDULE OF LOADS
S
EC DATE: 08/28/2024
R
EE
TR
IC 1975 MAIN CAMPUS
IN
A
L
OWNER
EN