0% found this document useful (0 votes)
26 views29 pages

INR21700-40P IEC62133 证书+报告 20211116

The document is a test report for a lithium-ion rechargeable cell (model INR21700/40P) manufactured by EVE Energy Co., Ltd., which complies with IEC 62133-2:2017 standards. It details the testing procedures, results, and safety evaluations conducted by Guangzhou MCM Certification & Testing Co., Ltd. The report confirms that the cell meets safety requirements and provides specifications for charging and discharging parameters.

Uploaded by

Itai Levy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
26 views29 pages

INR21700-40P IEC62133 证书+报告 20211116

The document is a test report for a lithium-ion rechargeable cell (model INR21700/40P) manufactured by EVE Energy Co., Ltd., which complies with IEC 62133-2:2017 standards. It details the testing procedures, results, and safety evaluations conducted by Guangzhou MCM Certification & Testing Co., Ltd. The report confirms that the cell meets safety requirements and provides specifications for charging and discharging parameters.

Uploaded by

Itai Levy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 29

JPTUV-129570

Lithium-ion rechargeable cell

EVE Energy Co., Ltd.


No. 38, Hui Feng 7th Road
Zhongkai Hi-Tech Zone, Huizhou, Guangdong, P.R. China

EVE Energy Co., Ltd.


No. 38, Hui Feng 7th Road
Zhongkai Hi-Tech Zone, Huizhou, Guangdong, P.R. China

EVE POWER Co., Ltd.


No. 68,
Jingnan Avenue, Jingmen Hi-tech Zone, Jingmen City, Hubei,
P.R. China

DC 3.6V, 4000mAh, 14.4Wh

EVE

N/A
INR21700/40P

IEC 62133-2:2017+A1
See Test Report for National Differences

CN214DGF 001

TÜV Rheinland Japan Ltd.


Global Technology Assessment Center
4-25-2 Kita-Yamata, Tsuzuki-ku
Yokohama 224-0021, Japan
Phone + 81 45 914-3888
Fax + 81 45 914-3354
Mail: [email protected]
Web : www.tuv.com

2021-11-16 A. Chen
Test Report issued under the responsibility of:

TEST REPORT
IEC 62133-2
Secondary cells and batteries containing alkaline or other non-acid
electrolytes – Safety requirements for portable sealed secondary cells,
and for batteries made from them, for use in portable applications –
Part 2: Lithium systems

Report Number. .............................. : CN214DGF 001


Date of issue ................................... : 2021-11-16
Total number of pages .................. : 24 pages

Name of Testing Laboratory


preparing the Report ..................... : Guangzhou MCM Certification & Testing Co., Ltd.
Applicant’s name ........................... : EVE Energy Co., Ltd.
Address ........................................... : No. 38, Hui Feng 7th Road Zhongkai Hi-Tech Zone, Huizhou,
Guangdong, P.R. China
Test specification:
Standard ......................................... : IEC 62133-2:2017, IEC 62133-2:2017/AMD1:2021
Test procedure ............................... : CB Scheme
Non-standard test method ............ : N/A
TRF template used ......................... : IECEE OD-2020-F1:2021, Ed.1.4
Test Report Form No. .................... : IEC62133_2B
Test Report Form(s) Originator .... : DEKRA Certification B.V.
Master TRF ..................................... : Dated 2021-08-31
Copyright © 2021 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment
and Components (IECEE System). All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB
Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved IECEE Testing Laboratory
and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
General disclaimer:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing NCB. The
authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this
Test Report.
Page 3 of 24 Report No. CN214DGF 001
List of Attachments (including a total number of pages in each attachment):
- Attachment 1: National Differences (3 pages)
- Attachment 2: Photo Documentation (1 page)
Summary of testing:

Tests performed (name of test and test Testing location:


clause): Guangzhou MCM Certification & Testing Co.,
cl.5.6.2 Design recommendation; Ltd.
cl.7.1 Charging procedure for test purposes (for 1 F No.13, Zhong San Section, Shi Guang Road,
Cells); Zhong Cun Street, Panyu District, Guangzhou,
cl.7.2.1 Continuous charging at constant voltage Guangdong China
(cells);
cl.7.3.1 External short circuit (cells);
cl.7.3.3 Free fall (cells );
cl.7.3.4 Thermal abuse (cells);
cl.7.3.5 Crush (cells);
cl.7.3.7 Forced discharge (cells);
cl.7.3.9 Design evaluation – Forced internal short-
circuit (cells)

Tests are made with the number of cells and


batteries specified in IEC 62133-2: 2017+A1 Table
1.

Summary of compliance with National Differences (List of countries addressed):


KR
KR=Republic of Korea

The product fulfils the requirements of EN 62133-2:2017+A1

TRF No. IEC62133_2B


Page 4 of 24 Report No. CN214DGF 001

Use of uncertainty of measurement for decisions on conformity (decision rule) :

No decision rule is specified by the IEC standard, when comparing the measurement result with the
applicable limit according to the specification in that standard. The decisions on conformity are made
without applying the measurement uncertainty (―simple acceptance‖ decision rule, previously known as
―accuracy method‖).

Other: N/A (to be specified, for example when required by the standard or client, or if national
accreditation requirements apply)

Information on uncertainty of measurement:


The uncertainties of measurement are calculated by the laboratory based on application of criteria given
by OD-5014 for test equipment and application of test methods, decision sheets and operational
procedures of IECEE.
IEC Guide 115 provides guidance on the application of measurement uncertainty principles and applying
the decision rule when reporting test results within IECEE scheme, noting that the reporting of the
measurement uncertainty for measurements is not necessary unless required by the test standard or
customer.
Calculations leading to the reported values are on file with the NCB and testing laboratory that conducted
the testing.

TRF No. IEC62133_2B


Page 5 of 24 Report No. CN214DGF 001

Copy of marking plate:


The artwork below may be only a draft. The use of certification marks on a product must be
authorized by the respective NCBs that own these marks.

Remark: The agreement about marking plate between battery pack manufacturer and cell factory
provided.

TRF No. IEC62133_2B


Page 6 of 24 Report No. CN214DGF 001

Test item particulars...................................................:


Classification of installation and use.......................: To be defined in final product
Supply Connection .....................................................: Electrode tab
Recommend charging method declared by the Charging the battery with 2000mA constant current
manufacturer ...............................................................: and 4.2V constant voltage until the current reduces
to 100mA at ambient 20°C±5°C.
Discharge current (0,2 It A) .......................................: 800mA
Specified final voltage ................................................: 2.5V
Upper limit charging voltage per cell .......................: 4.25V
Maximum charging current .......................................: 8000mA
Charging temperature upper limit ............................: 60°C
Charging temperature lower limit .............................: 0°C
Polymer cell electrolyte type .....................................: gel polymer solid polymer N/A
Possible test case verdicts:
- test case does not apply to the test object ........... : N/A
- test object does meet the requirement.................. : P (Pass)
- test object does not meet the requirement ........... : F (Fail)
Testing.......................................................................... :
Date of receipt of test item ........................................ : 2021-10-27
Date (s) of performance of tests ............................... : 2021-10-27 to 2021-11-11

General remarks:
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.

Throughout this report a comma / point is used as the decimal separator.


Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate Yes
includes more than one factory location and a Not applicable
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided ............................................................... :

When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .......................... : EVE POWER Co., Ltd.
No.68, Jingnan Avenue, Jingmen Hi-tech Zone,
Jingmen City, Hubei, P.R. China

TRF No. IEC62133_2B


Page 7 of 24 Report No. CN214DGF 001
General product information and other remarks:
The cell consists of the positive electrode plate, negative electrode plate, separator, electrolyte and case.
The positive and negative electrode plates are housed in the case in the state being separated by the
separator.

The main features of the cell are shown as below (clause 7.1.1):
Nominal Nominal Maximum Maximum Maximum
Rated Nominal Final
Model Charge Discharge Charge Discharge Charge
capacity voltage Voltage
Current Current Current Current Voltage

INR21700/40P 4000mAh 3.6V 2000mA 800mA 8000mA 50000mA 4.25V 2.5V

The main features of the cell are shown as below (clause 7.1.2):

Upper limit Taper-off Lower charge Upper charge


Model
charge voltage current temperature temperature

INR21700/40P 4.25V 200mA 0C 60C

Construction:

Cell(Unit:mm)
Circuit diagram:
None, Cell only

TRF No. IEC62133_2B


Page 8 of 24 Report No. CN214DGF 001
IEC 62133-2
Clause Requirement + Test Result - Remark Verdict

4 PARAMETER MEASUREMENT TOLERANCES P


Parameter measurement tolerances P

5 GENERAL SAFETY CONSIDERATIONS P


5.1 General P
Cells and batteries so designed and constructed P
that they are safe under conditions of both
intended use and reasonably foreseeable misuse
5.2 Insulation and wiring N/A
The insulation resistance between the positive No metal surface exists. N/A
terminal and externally exposed metal surfaces of
the battery (excluding electrical contact surfaces) is
not less than 5 MΩ
Insulation resistance (MΩ) ...................................... : N/A —
Internal wiring and insulation are sufficient to N/A
withstand maximum anticipated current, voltage and
temperature requirements
Orientation of wiring maintains adequate clearances N/A
and creepage distances between conductors
Mechanical integrity of internal connections N/A
accommodates reasonably foreseeable misuse
5.3 Venting P
Battery cases and cells incorporate a pressure relief Explosion-proof safety valve P
mechanism or are constructed so that they relieve for venting exists.
excessive internal pressure at a value and rate that
will preclude rupture, explosion and self-ignition
Encapsulation used to support cells within an outer N/A
casing does not cause the battery to overheat during
normal operation nor inhibit pressure relief
5.4 Temperature, voltage and current management Cell only. N/A
Batteries are designed such that abnormal N/A
temperature rise conditions are prevented
Batteries are designed to be within temperature, N/A
voltage and current limits specified by the cell
manufacturer
Batteries are provided with specifications and N/A
charging instructions for equipment manufacturers
so that specified chargers are designed to maintain
charging within the temperature, voltage and current
limits specified
5.5 Terminal contacts Complied. P
The size and shape of the terminal contacts ensure P
that they can carry the maximum anticipated current

TRF No. IEC62133_2B


Page 9 of 24 Report No. CN214DGF 001
IEC 62133-2
Clause Requirement + Test Result - Remark Verdict

External terminal contact surfaces are formed from P


conductive materials with good mechanical strength
and corrosion resistance
Terminal contacts are arranged to minimize the risk P
of short circuits
5.6 Assembly of cells into batteries N/A
5.6.1 General Cell only. N/A
Each battery has an independent control and N/A
protection for current, voltage, temperature and any
other parameter required for safety and to maintain
the cells within their operating region
This protection may be provided external to the N/A
battery such as within the charger or the end
devices
If protection is external to the battery, the N/A
manufacturer of the battery provide this safety
relevant information to the external device
manufacturer for implementation
If there is more than one battery housed in a single N/A
battery case, each battery has protective circuitry
that can maintain the cells within their operating
regions
Manufacturers of cells specify current, voltage and N/A
temperature limits so that the battery
manufacturer/designer may ensure proper design
and assembly
Batteries that are designed for the selective N/A
discharge of a portion of their series connected cells
incorporate circuitry to prevent operation of cells
outside the limits specified by the cell manufacturer
Protective circuit components are added as N/A
appropriate and consideration given to the end-
device application
The manufacturer of the battery provide a safety N/A
analysis of the battery safety circuitry with a test
report including a fault analysis of the protection
circuit under both charging and discharging
conditions confirming the compliance
5.6.2 Design recommendation Cell only. N/A
For the battery consisting of a single cell or a single N/A
cellblock, it is recommended that the charging
voltage of the cell does not exceed the upper limit of
the charging voltage specified in Table 2

TRF No. IEC62133_2B


Page 10 of 24 Report No. CN214DGF 001
IEC 62133-2
Clause Requirement + Test Result - Remark Verdict

For the battery consisting of series-connected plural N/A


single cells or series-connected plural cellblocks, it is
recommended that the voltages of any one of the
single cells or single cellblocks does not exceed the
upper limit of the charging voltage, specified in
Table 2, by monitoring the voltage of every single
cell or the single cellblocks
For the battery consisting of series-connected plural N/A
single cells or series-connected plural cellblocks, it is
recommended that charging is stopped when the
upper limit of the charging voltage is exceeded for
any one of the single cells or single cellblocks by
measuring the voltage of every single cell or the
single cellblocks
For batteries consisting of series-connected cells or N/A
cell blocks, nominal charge voltage are not counted
as an overcharge protection
For batteries consisting of series-connected cells or N/A
cell blocks, cells have closely matched capacities,
be of the same design, be of the same chemistry
and be from the same manufacturer
It is recommended that the cells and cell blocks are N/A
not discharged beyond the cell manufacturer’s
specified final voltage
For batteries consisting of series-connected cells or N/A
cell blocks, cell balancing circuitry are incorporated
into the battery management system
5.6.3 Mechanical protection for cells and components of Cell only. N/A
batteries
Mechanical protection for cells, cell connections and N/A
control circuits within the battery are provided to
prevent damage as a result of intended use and
reasonably foreseeable misuse
The mechanical protection can be provided by the N/A
battery case or it can be provided by the end
product enclosure for those batteries intended for
building into an end product
The battery case and compartments housing cells N/A
are designed to accommodate cell dimensional
tolerances during charging and discharging as
recommended by the cell manufacturer
For batteries intended for building into a portable N/A
end product, testing with the battery installed within
the end product is considered when conducting
mechanical tests
5.7 Quality plan P

TRF No. IEC62133_2B


Page 11 of 24 Report No. CN214DGF 001
IEC 62133-2
Clause Requirement + Test Result - Remark Verdict

The manufacturer prepares and implements a Complied. P


quality plan that defines procedures for the ISO 9001: 2015 certificate
inspection of materials, components, cells and provided.
batteries and which covers the whole process of
producing each type of cell or battery
5.8 Battery safety components See TABLE: Critical N/A
components information

6 TYPE TEST AND SAMPLE SIZE P


Tests are made with the number of cells or batteries P
specified in Table 1 using cells or batteries that are
not more than six months old
The internal resistance of coin cells are measured in Not coin cells N/A
accordance with Annex D. Coin cells with internal
resistance less than or equal to 3 Ω are tested in
accordance with Table 1
Unless otherwise specified, tests are carried out in P
an ambient temperature of 20 °C ± 5 °C
The safety analysis of 5.6.1 identify those N/A
components of the protection circuit that are critical
for short-circuit, overcharge and over discharge
protection
When conducting the short-circuit test, consideration Cell only. N/A
is given to the simulation of any single fault condition
that is likely to occur in the protecting circuit that
would affect the short-circuit test

7 SPECIFIC REQUIREMENTS AND TESTS P


7.1 Charging procedure for test purposes P
7.1.1 First procedure P
This charging procedure applies to subclauses other P
than those specified in 7.1.2
Unless otherwise stated in this document, the See page 6. P
charging procedure for test purposes is carried out
in an ambient temperature of 20 °C ± 5 °C, using the
method declared by the manufacturer
Prior to charging, the battery has been discharged at See page 6. P
20 °C ± 5 °C at a constant current of 0,2 It A down to
a specified final voltage
7.1.2 Second procedure P
This charging procedure applies only to 7.3.1, 7.3.4, P
7.3.5, and 7.3.9

TRF No. IEC62133_2B


Page 12 of 24 Report No. CN214DGF 001
IEC 62133-2
Clause Requirement + Test Result - Remark Verdict

After stabilization for 1 h to 4 h, at an ambient Charge temperature specified P


temperature of the highest test temperature and the by manufacturer: 0-60°C.
lowest test temperature, respectively, as specified in 65°C used for upper limit tests
Table 2, cells are charged by using the upper limit -5°C used for lower limit tests
charging voltage and maximum charging current,
until the charging current is reduced to 0,05 It A,
using a constant current to constant voltage
charging method
7.2 Intended use P
7.2.1 Continuous charging at constant voltage (cells) Tested complied. P
Fully charged cells are subjected for 7 days to a Charging for 7days with P
charge using the charging method for current and 2.0A and 4.2V.
standard voltage specified by the cell manufacturer
Results: no fire, no explosion, no leakage ................. : (See appended table 7.2.1) P
7.2.2 Case stress at high ambient temperature (battery) Cell only. N/A
Oven temperature (°C) ............................................... : N/A —
Results: no physical distortion of the battery case N/A
resulting in exposure of internal protective
components and cells
7.3 Reasonably foreseeable misuse P
7.3.1 External short-circuit (cell) Tested complied. P
The cells were tested until one of the following P
occurred:
- 24 hours elapsed; or N/A
- The case temperature declined by 20 % of the P
maximum temperature rise
Results: no fire, no explosion ................................... : (See appended table 7.3.1) P
7.3.2 External short-circuit (battery) Cell only. N/A
The batteries were tested until one of the following N/A
occurred:
- 24 hours elapsed; or N/A
- The case temperature declined by 20 % of the N/A
maximum temperature rise
In case of rapid decline in short circuit current, the N/A
battery pack remained on test for an additional one
hour after the current reached a low end steady
state condition
A single fault in the discharge protection circuit is N/A
conducted on one to four (depending upon the
protection circuit) of the five samples before
conducting the short-circuit test

TRF No. IEC62133_2B


Page 13 of 24 Report No. CN214DGF 001
IEC 62133-2
Clause Requirement + Test Result - Remark Verdict

A single fault applies to protective component parts N/A


such as MOSFET (metal oxide semiconductor field-
effect transistor), fuse, thermostat or positive
temperature coefficient (PTC) thermistor
Results: no fire, no explosion ................................... : (See appended table 7.3.2) N/A
7.3.3 Free fall Tested complied. P
Results: no fire, no explosion No fire. No explosion P
7.3.4 Thermal abuse (cells) Tested complied. P
Oven temperature (°C) ............................................... : 130°C —
Results: no fire, no explosion No fire. No explosion P
7.3.5 Crush (cells) Tested complied. P
The crushing force was released upon: P
- The maximum force of 13 kN  0,78 kN has been P
applied; or
- An abrupt voltage drop of one-third of the original N/A
voltage has been obtained
Results: no fire, no explosion ................................... : (See appended table 7.3.5) P
7.3.6 Over-charging of battery Cell only. N/A
The supply voltage which is: N/A
- 1,4 times the upper limit charging voltage N/A
presented in Table A.1 (but not to exceed 6,0 V) for
single cell/cell block batteries or
- 1,2 times the upper limit charging voltage resented N/A
in Table A.1 per cell for series connected multi-cell
batteries, and
- Sufficient to maintain a current of 2,0 It A N/A
throughout the duration of the test or until the supply
voltage is reached
Test was continued until the temperature of the N/A
outer casing:
- Reached steady state conditions (less than 10 °C N/A
change in 30-minute period); or
- Returned to ambient N/A
Results: no fire, no explosion ................................... : (See appended table 7.3.6) N/A
7.3.7 Forced discharge (cells) Tested complied. P
Discharge a single cell to the lower limit discharge Lower limit discharge voltage P
voltage specified by the cell manufacturer 2.5V
The discharged cell is then subjected to a forced P
discharge at 1 It A to the negative value of the upper
limit charging voltage

TRF No. IEC62133_2B


Page 14 of 24 Report No. CN214DGF 001
IEC 62133-2
Clause Requirement + Test Result - Remark Verdict

- The discharge voltage reaches the negative value N/A


of upper limit charging voltage within the testing
duration. The voltage is maintained at the negative
value of the upper limit charging voltage by reducing
the current for the remainder of the testing duration
- The discharge voltage does not reach the negative P
value of upper limit charging voltage within the
testing duration. The test is terminated at the end of
the testing duration
Results: no fire, no explosion ................................... : (See appended table 7.3.7) P
7.3.8 Mechanical tests (batteries) N/A
7.3.8.1 Vibration Cell only. N/A
Results: no fire, no explosion, no rupture, no (See appended table 7.3.8.1) N/A
leakage or venting. ................................................... :
7.3.8.2 Mechanical shock Cell only. N/A
Results: no leakage, no venting, no rupture, no (See appended table 7.3.8.2) N/A
explosion and no fire ................................................ :
7.3.9 Design evaluation – Forced internal short-circuit Tested complied. P
(cells)
The cells complied with national requirement for ...... : France, Japan, Korea, —
Switzerland
The pressing was stopped upon: P
- A voltage drop of 50 mV has been detected; or N/A
- The pressing force of 800 N (cylindrical cells) or 800N for cylindrical cell. P
400 N (prismatic cells) has been reached
Results: no fire .......................................................... : (See appended table 7.3.9) P

8 INFORMATION FOR SAFETY P


8.1 General P
Manufacturers of secondary cells provides Information for safety P
information about current, voltage and temperature mentioned in manufacturer’s
limits of their products specifications.
Manufacturers of batteries provides information N/A
regarding how to minimize and mitigate hazards to
equipment manufacturers or end-users
Systems analyses are performed by device N/A
manufacturers to ensure that a particular battery
design prevents hazards from occurring during use
of a product
As appropriate, any information relating to hazard N/A
avoidance resulting from a system analysis is
provided to the end user
8.2 Small cell and battery safety information Not small cells N/A

TRF No. IEC62133_2B


Page 15 of 24 Report No. CN214DGF 001
IEC 62133-2
Clause Requirement + Test Result - Remark Verdict

The following warning language is to be provided N/A


with the information packaged with the small cells
and batteries or equipment using them:
- Keep small cells and batteries which are N/A
considered swallowable out of the reach of children
- Swallowing may lead to burns, perforation of soft N/A
tissue, and death. Severe burns can occur within 2
h of ingestion
- In case of ingestion of a cell or battery, seek N/A
medical assistance promptly

9 MARKING P
9.1 Cell marking P
Cells are marked as specified in IEC 61960, except N/A
coin cells
Coin cells whose external surface area is too small N/A
to accommodate the markings on the cells show
the designation and polarity
By agreement between the cell manufacturer and Agreement between the cell P
the battery and/or end product manufacturer, manufacturer and user
component cells used in the manufacture of a provided.
battery need not be marked
9.2 Battery marking Cell only. N/A
Batteries are marked as specified in IEC 61960, N/A
except for coin batteries
Coin batteries whose external surface area is too N/A
small to accommodate the markings on the
batteries show the designation and polarity
Batteries are marked with an appropriate caution N/A
statement
- Terminals have clear polarity marking on the N/A
external surface of the battery, or
- Not be marked with polarity markings if the design N/A
of the external connector prevents reverse polarity
connections
9.3 Caution for ingestion of small cells and N/A
batteries
Coin cells and batteries identified as small batteries N/A
include a caution statement regarding the hazards
of ingestion in accordance with 8.2
Small cells and batteries are intended for direct N/A
sale in consumer-replaceable applications, caution
for ingestion is given on the immediate package
9.4 Other information P

TRF No. IEC62133_2B


Page 16 of 24 Report No. CN214DGF 001
IEC 62133-2
Clause Requirement + Test Result - Remark Verdict

The following information are marked on or Information for storage and P


supplied with the battery: disposal instructions
mentioned in manufacturer’s
specifications.
- Storage and disposal instructions P
- Recommended charging instructions P

10 PACKAGING AND TRANSPORT N/A


Packaging for coin cells are not be small enough to Not coin cells. N/A
fit within the limits of the ingestion gauge of Figure
3

ANNEX A CHARGING AND DISCHARGING RANGE OF SECONDARY LITHIUM ION P


CELLS FOR SAFE USE
A.1 General P
A.2 Safety of lithium ion secondary battery Complied. P
A.3 Consideration on charging voltage Complied. P
A.3.1 General P
A.3.2 Upper limit charging voltage 4.25V applied. P
A.3.2.1 General P
A.3.2.2 Explanation of safety viewpoint P
A.3.2.3 Safety requirements, when different upper limit 4.25V applied. P
charging voltage is applied
A.4 Consideration of temperature and charging P
current
A.4.1 General P
A.4.2 Recommended temperature range See A.4.2.2. P
A.4.2.1 General P
A.4.2.2 Safety consideration when a different Charging temperature P
recommended temperature range is applied declared by client is: 0-60C
A.4.3 High temperature range P
A.4.3.1 General P
A.4.3.2 Explanation of safety viewpoint P
A.4.3.3 Safety considerations when specifying charging P
conditions in the high temperature range
A.4.3.4 Safety considerations when specifying a new upper 65C applied. P
limit in the high temperature range
A.4.4 Low temperature range P
A.4.4.1 General P
A.4.4.2 Explanation of safety viewpoint P

TRF No. IEC62133_2B


Page 17 of 24 Report No. CN214DGF 001
IEC 62133-2
Clause Requirement + Test Result - Remark Verdict

A.4.4.3 Safety considerations, when specifying charging P


conditions in the low temperature range
A.4.4.4 Safety considerations when specifying a new lower -5C applied. P
limit in the low temperature range
A.4.5 Scope of the application of charging current P
A.4.6 Consideration of discharge P
A.4.6.1 General P
A.4.6.2 Final discharge voltage and explanation of safety 2.5V specified by cell P
viewpoint manufacturer.
A.4.6.3 Discharge current and temperature range P
A.4.6.4 Scope of application of the discharging current P
A.5 Sample preparation P
A.5.1 General P
A.5.2 Insertion procedure for nickel particle to generate P
internal short
A.5.3 Disassembly of charged cell P
A.5.4 Shape of nickel particle P
A.5.5 Insertion of nickel particle in cylindrical cell P

A.5.5.1 Insertion of nickel particle in winding core P

A.5.5.2 Marking the position of the nickel particle on both P


ends of the winding core of the separator
A.5.6 Insertion of nickel particle in prismatic cell N/A
A.6 Experimental procedure of the forced internal P
short-circuit test
A.6.1 Material and tools for preparation of nickel particle P
A.6.2 Example of a nickel particle preparation procedure P
A.6.3 Positioning (or placement) of a nickel particle P
A.6.4 Damaged separator precaution P
A.6.5 Caution for rewinding separator and electrode P
A.6.6 Insulation film for preventing short-circuit P
A.6.7 Caution when disassembling a cell P
A.6.8 Protective equipment for safety P
A.6.9 Caution in the case of fire during disassembling P
A.6.10 Caution for the disassembling process and P
pressing the electrode core
A.6.11 Recommended specifications for the pressing P
device

TRF No. IEC62133_2B


Page 18 of 24 Report No. CN214DGF 001
IEC 62133-2
Clause Requirement + Test Result - Remark Verdict

ANNEX B RECOMMENDATIONS TO EQUIPMENT MANUFACTURERS AND BATTERY N/A


ASSEMBLERS

ANNEX C RECOMMENDATIONS TO THE END-USERS N/A

ANNEX D MEASUREMENT OF THE INTERNAL AC RESISTANCE FOR COIN CELLS N/A


D.1 General N/A
D.2 Method N/A
A sample size of three coin cells is required for this N/A
measurement
Coin cells with an internal resistance greater than 3 (See appended table D.2) N/A
Ω require no further testing ........................................ :
Coin cells with an internal resistance less than or N/A
equal to 3 Ω are subjected to the testing according
to Clause 6 and Table 1

ANNEX E PACKAGING AND TRANSPORT N/A

ANNEX F COMPONENT STANDARDS REFERENCES N/A

TRF No. IEC62133_2B


Page 19 of 24 Report No. CN214DGF 001
IEC 62133-2
Clause Requirement + Test Result - Remark Verdict

7.2.1 TABLE: Continuous charging at constant voltage (cells) P


Sample No. Recommended Recommended OCV before test Results
charging voltage charging current (Vdc)
Vc (Vdc) Irec (A)
Cell #01 4.20 2.0 4.16 P
Cell #02 4.20 2.0 4.16 P
Cell #03 4.20 2.0 4.16 P
Cell #04 4.20 2.0 4.16 P
Cell #05 4.20 2.0 4.16 P
Supplementary information:
- No fire or explosion
- No leakage

7.3.1 TABLE: External short circuit (cell) P


Sample No. Ambient (C) OCV at start of Resistance of Maximum case Results
test (Vdc) circuit (m) temperature
rise T (K), °C
Samples charged at charging temperature upper limit (65°C)
Cell #06 56.9 4.19 87.7 92.7 P
Cell #07 56.9 4.19 89.1 108.0 P
Cell #08 56.9 4.19 87.2 114.1 P
Cell #09 56.9 4.18 84.6 119.3 P
Cell #10 56.9 4.18 84.5 114.6 P
Samples charged at charging temperature lower limit (-5°C)
Cell #11 56.6 4.18 86.9 123.1 P
Cell #12 56.6 4.18 83.4 128.6 P
Cell #13 56.6 4.18 87.6 122.5 P
Cell #14 56.6 4.17 84.5 100.2 P
Cell #15 56.6 4.17 86.8 123.1 P
Supplementary information:
- No fire or explosion

TRF No. IEC62133_2B


Page 20 of 24 Report No. CN214DGF 001
IEC 62133-2
Clause Requirement + Test Result - Remark Verdict

7.3.2 TABLE: External short circuit (battery) N/A


Sample No. Ambient T OCV before Resistance Maximum Component Results
(C) test (Vdc) of circuit case single fault
(m) temperature condition
rise T (K)
°C

Supplementary information:
- No fire or explosion
- Others (please explain)

7.3.5 TABLE: Crush (cells) P


Sample No. OCV before test OCV at removal of Maximum force Results
(Vdc) crushing force applied to the cell
(Vdc) during crush (kN)
Samples charged at charging temperature upper limit (65°C)
Cell #29 4.20 4.18 13.18 P
Cell #30 4.19 4.18 13.13 P
Cell #31 4.19 4.18 13.07 P
Cell #32 4.19 4.18 13.12 P
Cell #33 4.19 4.19 13.13 P
Samples charged at charging temperature lower limit (-5°C)
Cell #34 4.17 4.17 13.17 P
Cell #35 4.17 4.16 13.12 P
Cell #36 4.17 4.16 13.11 P
Cell #37 4.16 4.16 13.14 P
Cell #38 4.16 4.16 13.13 P
Supplementary information:
- No fire or explosion

TRF No. IEC62133_2B


Page 21 of 24 Report No. CN214DGF 001
IEC 62133-2
Clause Requirement + Test Result - Remark Verdict

7.3.6 TABLE: Over-charging of battery N/A


Constant charging current (A) .................................. : 
Supply voltage (Vdc) .................................................. : 
Sample No. OCV before charging Total charging time Maximum outer case Results
(Vdc) (minute) temperature (C)

Supplementary information:
- No fire or explosion

7.3.7 TABLE: Forced discharge (cells) P


Sample No. OCV before Measured reverse Lower limit Results
application of charge It (A) discharge voltage
reverse charge (Vdc) (Vdc)
Cell #39 2.98 4.0 2.5 P
Cell #40 2.98 4.0 2.5 P
Cell #41 2.96 4.0 2.5 P
Cell #42 3.03 4.0 2.5 P
Cell #43 3.00 4.0 2.5 P
Supplementary information:
- No fire or explosion

7.3.8.1 TABLE: Vibration N/A


Sample No. OCV before OCV after test Mass before Mass after test Results
test (Vdc) (Vdc) test (g) (g)

Supplementary information:
- No fire or explosion
- No rupture
- No leakage
- No venting

TRF No. IEC62133_2B


Page 22 of 24 Report No. CN214DGF 001
IEC 62133-2
Clause Requirement + Test Result - Remark Verdict

7.3.8.2 TABLE: Mechanical shock N/A


Sample No. OCV before OCV after test Mass before Mass after test Results
test (Vdc) (Vdc) test (g) (g)

Supplementary information:
- No fire or explosion
- No rupture
- No leakage
- No venting

7.3.9 TABLE: Forced internal short circuit (cells) P


Sample No. Chamber OCV before Particle Maximum Results
1)
ambient T (C) test (Vdc) location applied
pressure (N)
Samples charged at charging temperature upper limit (65°C)
Cell #44 65 4.19 1 800 P
Cell #45 65 4.19 1 800 P
Cell #46 65 4.19 1 800 P
Cell #47 65 4.19 1 800 P
Cell #48 65 4.19 1 800 P
Samples charged at charging temperature lower limit (-5°C)
Cell #49 -5 4.17 1 800 P
Cell #50 -5 4.17 1 800 P
Cell #51 -5 4.17 1 800 P
Cell #52 -5 4.16 1 800 P
Cell #53 -5 4.16 1 800 P
Supplementary information:
1)
Identify one of the following:
1: Nickel particle inserted between positive and negative (active material) coated area.
2: Nickel particle inserted between positive aluminium foil and negative active material coated area.
Remark: No position 2.
- No fire

TRF No. IEC62133_2B


Page 23 of 24 Report No. CN214DGF 001
IEC 62133-2
Clause Requirement + Test Result - Remark Verdict

D.2 TABLE: Internal AC resistance for coin cells N/A


1)
Sample no. Ambient T (C) Store time (h) Resistance Rac () Results

Supplementary information:

TRF No. IEC62133_2B


Page 24 of 24 Report No. CN214DGF 001
IEC 62133-2
Clause Requirement + Test Result - Remark Verdict

TABLE: Critical components information P


Object / part Manufacturer/ Type / Technical data Standard Mark(s) of
No. trademark model conformity
1)

Cell EVE Energy Co., INR21700/40 DC3.6V, IEC 62133- Tested with
Ltd. P 4000mAh,14.4Wh 2:2017+A1 appliance
Positive Hunan 10073704 LiNixCoyAlzO2, content -- --
Electrode Changyuan Co., of Ni is the maxium
Ltd. among this metal
Negative Shanghai 10055385 Carbon -- --
Electrode Shanshan New
Energy
Technology Co.,
Ltd
Separator Shenzhen Senior 10086599 PE+Al2O3 -- --
Techonlogy
Material Co., Ltd.
Electrolyte Shenzhen 10028668 LiPF6+EC+DMC -- --
Capchem +EMC
Technology Co.,
Ltd.
Wuxi Jingyang 10059502 SPCE -- --
Steel can Technology Co.,
Ltd.
Supplementary information:
1)
Provided evidence ensures the agreed level of compliance. See OD-CB2039.

-- End of Report --

TRF No. IEC62133_2B


Page 1 of 3
Attachment 1 Report No.: CN214DGF 001

IEC62133_2A ATTACHMENT

Clause Requirement + Test Result - Remark Verdict


ATTACHMENT TO TEST REPORT
IEC 62133-2
(Republic of Korea) NATIONAL DIFFERENCES
(Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for
portable sealed secondary lithium cells, and for batteries made from them, for use in portable applications -
Part 2: Lithium systems)

Differences according to ............... : National standard KC62133-2(2020-07)

TRF template used: ..................... : IECEE OD-2020-F3, Ed. 1.1

Attachment Form No. .................... : KR_ND_IEC62133_2A

Attachment Originator ................... : KTR

Master Attachment ......................... : Dated 2020-09-25

Copyright © 2020 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.

National Differences
7.3.6 Over-charging of battery N/A
(Revision) [Add the bolded text]

b) Test
The test shall be carried out in an ambient
temperature of 20 °C ± 5 °C. Each test battery shall
be discharged at a constant current of 0,2 It A, to a
final discharge voltage specified by the
manufacturer. Sample batteries shall then be
charged at a constant current of 2,0 It A, using a
supply voltage which is:
• 1,4 times the upper limit charging voltage
presented in Table A.1 (but not to exceed 6,0 V) for
single cell/cell block batteries or Cell only. N/A
• 1,2 times the upper limit charging voltage
presented in Table A.1 per cell for series connected
multi-cell batteries, and
• sufficient to maintain a current of 2,0 It A
throughout the duration of the test or until the
supply voltage is reached.
• In case the charging voltage specified by the
manufacturer is higher than the overcharge test
voltage, the maximum charging voltage
specified by manufacturer should be applied
with 2.0 ItA,
(e.g., quick charging power bank, etc.)
Page 2 of 3
Attachment 1 Report No.: CN214DGF 001

IEC62133_2A ATTACHMENT

Clause Requirement + Test Result - Remark Verdict

[Replace to the following statement]


c) Acceptance criteria
N/A
Overcharging exceeding to the limits specified by
the manufacturer should not result in fire or
explosion.
Annex G Definition for shape and materials of outer case for cell P
(Addition) G.1 General
Annex G provides definitions for shape and
materials of outer case for cell

G.2 Shape of outer case for cell


G 2.1 Cylindrical cell
Cell with a cylindrical shape in which the overall
height is equal to or greater than diameter. (Shape of outer cases)
Cylindrical
G 2.2 Prismatic cell Prismatic

Cell having the shape of a parallelepiped whose
faces are rectangular (Materials of outer cases)
Hard
G.3 Materials of outer case for cell Soft
G.3.1 Soft case
Non-metallic outer case or container for cell

G.3.2 Hard case


Metallic outer case or container for cell.

Annex H Calculation method of the volumetric energy density for cell —


(Addition) Annex H provide a calculation method of the
volumetric energy density for cell in use of smart
phone, tablet, notebook.

H.1 General
Unless otherwise stated in the Annex E, the
dimensions for calculation are based on these for 577.56 Wh/L —
cell before shipment and the volumetric energy
density shall be calculated with a maximum values
specified by manufacturer. If the specification for
cell can’t be provided a dimension for calculation,
the manufacturer’s other documentation shall be
provided to demonstrate compliance for its
calculation.
Page 3 of 3
Attachment 1 Report No.: CN214DGF 001

IEC62133_2A ATTACHMENT

Clause Requirement + Test Result - Remark Verdict

H.2 Calculation Method

[H.1 – Prismatic cell using soft case]

[H.2 – Prismatic cell using hard case]

[H.3 – Cylindrical cell using hard case]


Attachment 2 Photo Documentation

Page 1 of 1 Report No.: CN214DGF 001


Product: Lithium-ion rechargeable cell
Type Designation: INR21700/40P

Figure 1 Front view of cell

Figure 2 Back view of cell