0% found this document useful (0 votes)
39 views3 pages

Instruction A11_A20 EN

The document provides instructions for operating the command and control panel, emphasizing the importance of understanding command functions before testing. It details various alarms, including high/low pressure and fan motor protection, and includes troubleshooting tips for specific error codes like EE and SE alarms. Maintenance procedures and the need for professional personnel for certain operations are also highlighted.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
39 views3 pages

Instruction A11_A20 EN

The document provides instructions for operating the command and control panel, emphasizing the importance of understanding command functions before testing. It details various alarms, including high/low pressure and fan motor protection, and includes troubleshooting tips for specific error codes like EE and SE alarms. Maintenance procedures and the need for professional personnel for certain operations are also highlighted.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

ENGLISH

COMMAND AND CONTROL PANEL ( A11 ÷ A14)


BEFORE CARRYING OUT THE OPERATION TEST, READ CAREFULLY AND ACQUIRE A GOOD KNOWLEDGE OF THE
COMMAND FUNCTIONS.

Ref. 1) Digital controller


Ref. 8) Stop - Running button – Door block
Ref. 9) Green indicator of voltage - Running
Ref. 10) Red indicator of alarm for:
- High pressure 1
- Fan motor protection

2 3 4 5 1
8 2 Alarms
3 Power ON
6 4 Fan ON
9
5 PDP temperature
7 10 6 Unit °C or °F
7 Alarms led

COMMAND AND CONTROL PANEL ( A15 ÷ A20 )


BEFORE CARRYING OUT THE OPERATION TEST, READ CAREFULLY AND ACQUIRE A GOOD KNOWLEDGE OF THE
COMMAND FUNCTIONS.

Ref. 1) Digital controller


Ref. 8) Stop - Running button - Door block
Ref. 9) Green indicator of voltage - Running
Ref. 10) Red indicator of alarm for:
- Condensate drain
Ref. 11) Red indicator of alarm for:
- High / Low pressure 1
- Fan motor protection

2 3 4 5 1
2 Alarms
8 3 Power ON
6 9 4 Fan ON
5 PDP temperature
7 10 11 6 Unit °C or °F
7 Alarms led

ICON MODE FUNCTIONS


OFF No active alarms
ALARM Probe failure alarm
ON
High/Low temperature alarm
OFF Dryer off
COMPRESSOR FLASH Maintenance warning
ON Dryer on
OFF Fan off
FAN FLASH n/a
ON Fan on

Cod. 2200780107 01 – Edition 01/2015 - 1


ENGLISH
DIGITAL CONTROL ALARMS

N.B. OPERATIONS MARKED   MUST BE CARRIED OUT BY PROFESSIONALLY SKILLED PERSONNEL APPROVED THE
MANUFACTURER

DISPLAY FLASHING WARNING NOTES Possible root causes Observations

Dryer is working OK n/a

Warning icon NOT


Fan control probe failed  replace probe
fashing, label P1 flashing

 refrigerant leak
Warning icon NOT  flow rate / inlet
High PDP call for service
fashing, label H1 flashing  temperature
exeeding the limit.

 hot gas by pass


valve out of order.
Warning icon NOT
Low PDP call for service  ambient temperature
fashing, label L1 flashing
lower then limits

EE ALARM

EE alarm is shown when internal EPROM errors happens, if this warning will appear, the dryer will stop running. The error can be reset by pressing
one of the four buttons of the controller, anyway please replace the controller itself.

NOTE: In case of EE alarm please contact your tech support.

2 - Edition 01/2015 Cod. 2200780107 01 -


ENGLISH

SE ALARM

After 4000Hrs, the controller will issue a “SE” warning. This is the maintenance due warning.

How to reset the maintenance warning: follow steps 1 to 6