0% found this document useful (0 votes)
55 views6 pages

Cummins-C100N6_QSJ5.9G

The document provides specifications for Cummins spark-ignited generator sets ranging from 45 to 100 kW for standby applications, highlighting features such as a rugged gas engine, advanced control systems, and various alternator options. It details performance metrics, compliance with EPA emissions standards, and available configurations for natural gas and propane. Additionally, it includes information on warranty, cooling systems, and optional accessories for enhanced functionality.

Uploaded by

ikhtiyar ali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
55 views6 pages

Cummins-C100N6_QSJ5.9G

The document provides specifications for Cummins spark-ignited generator sets ranging from 45 to 100 kW for standby applications, highlighting features such as a rugged gas engine, advanced control systems, and various alternator options. It details performance metrics, compliance with EPA emissions standards, and available configurations for natural gas and propane. Additionally, it includes information on warranty, cooling systems, and optional accessories for enhanced functionality.

Uploaded by

ikhtiyar ali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Specification sheet

Spark-ignited
generator set
45–100 kW Standby
EPA emissions

Description
®
Cummins generator sets are fully integrated Cooling system - Standard cooling package
power generation systems providing optimum provides reliable running at up to 50 °C
performance, reliability and versatility for (122 °F) ambient temperature.
stationary Standby applications.
Enclosures - The aesthetically appealing
Features enclosure incorporates special designs that
deliver one of the quietest generators of its kind.
Gas engine - Rugged 4-cycle Cummins Aluminum material plus durable powder coat
QSJ5.9G spark-ignited engine delivers reliable paint provides the best anti-corrosion
power. The electronic air/fuel ratio control performance. The generator set enclosure has
provides optimum engine performance and fast been evaluated to withstand 180 MPH wind
response to load changes. loads in accordance with ASCE7 -10. The
Alternator - Several alternator sizes offer design has hinged doors to provide easy access
for service and maintenance.
selectable motor starting capability with low
reactance 2/3 pitch windings, low waveform NFPA - The generator set accepts full rated load
distortion with non-linear loads and fault clearing in a single step in accordance with NFPA 110 for
short-circuit capability. Level 1 systems.
®
Control system - The PowerCommand 1.1 Warranty and service - Backed by a
electronic control is standard equipment and comprehensive warranty and worldwide
provides total generator set system integration distributor network.
including automatic remote starting/stopping,
precise frequency and voltage regulation, alarm
and status message display, output metering,
auto-shutdown at fault detection and NFPA 110
Level 1 compliance. The PowerCommand 2.3
control is also optional and is UL 508 Listed and
TM
provides AmpSentry protection.

Natural gas Propane


Standby Standby
Model kW kVA kW kVA Data sheets
C45 N6 45 56 45 56 NAD-6093-EN
C50 N6 50 63 50 63 NAD-6094-EN
C60 N6 60 75 60 75 NAD-6095-EN
C70 N6 70 88 70 88 NAD-6096-EN
C80 N6 80 100 80 100 NAD-6097-EN
C100 N6 100 125 100 125 NAD-6098-EN

power.cummins.com
©2017 Cummins Inc. | NAS-6092-EN (10/17)
Generator set specifications
Governor regulation class ISO8528 Part 1 Class G3
Voltage regulation, no load to full load ± 1.0%
Random voltage variation ± 1.0%
Frequency regulation Isochronous
Random frequency variation ± 0.25% @ 60 Hz
Radio frequency emissions compliance Meets requirements of most industrial and commercial applications

Engine specifications
Design Naturally aspirated or turbocharged (varies by generator set model)
Bore 102.1 mm (4.02 in.)
Stroke 119.9 mm (4.72 in.)
Displacement 5.9 liters (359 in3)
Cylinder block Cast iron, in-line 6 cylinder
Battery capacity 850 amps at ambient temperature of 0 °F to 32 °F (-18 °C to 0 °C)
Battery charging alternator 52 amps
Starting voltage 12 volt, negative ground
Lube oil filter type(s) Spin-on with relief valve
Standard cooling system 50 °C (122 °F) ambient cooling system
Rated speed 1800 rpm

Alternator specifications
Design Brushless, 4 pole, drip proof, revolving field
Stator 2/3 pitch
Rotor Direct coupled, flexible disc
Insulation system Class H per NEMA MG1-1.65
Standard temperature rise 120 ºC (248 °F) Standby
Exciter type Torque match (shunt) with PMG as option
Alternator cooling Direct drive centrifugal blower
AC waveform Total Harmonic Distortion (THDV) < 5% no load to full linear load, < 3% for any single harmonic
Telephone Influence Factor (TIF) < 50 per NEMA MG1-22.43
Telephone Harmonic Factor (THF) < 3%

Available voltages
1-phase 3-phase
 120/240  120/208  120/240  277/480  347/600  127/220

Generator set options


Fuel system Control Cooling system
 Single fuel - natural gas or propane  AC output analog meters  Shutdown – low coolant level
vapor, field selectable  Stop switch – emergency  Warning – low coolant level
 Dual fuel – natural gas and propane  Auxiliary output relays (2)  Extension – coolant drain
vapor auto changeover  Auxiliary configurable signal  Coolant heater options:
 Low fuel gas pressure warning inputs (8) and relay outputs (8) - <4 °C (40 °F) – cold weather
Engine Electrical - <-17 °C (0 °F) – extreme cold
 Engine air cleaner  One, two or three circuit breaker Exhaust system
 Shut down – low oil pressure configurations  Exhaust connector NPT
 Extension – oil drain  80% rated circuit breakers  Exhaust muffler mounted
 Engine oil heater  100% rated LSI circuit breakers Generator set application
Alternator  Battery charger  Base barrier – elevated genset
 120 °C temperature rise alternator Enclosure  Battery rack, standard battery
 105 °C temperature rise alternator  Aluminum enclosure Sound Level 1  Battery rack, larger battery
 PMG or Level 2, sandstone or green color  Radiator outlet duct adapter
 Alternator heater, 120 V  Aluminum weather protective Warranty
 Reconnectable full 1 phase output enclosure with muffler installed,
 Base warranty – 2 year/1000
alternator green color
hours, Standby
 3 year Standby warranty options
 5 year Standby warranty options

power.cummins.com
©2017 Cummins Inc. | NAS-6092-EN (10/17)
Generator set accessories
 Coolant heaters – 1000 W/1500 W  Remote monitoring device –  Alternator PMG
 Battery rack, standard/larger battery PowerCommand 500/550  Alternator heater
 Battery heater kit  Battery charger – stand-alone, 12 V
 Engine oil heater  Circuit breakers
 Remote control displays  Enclosure Sound Level 1 to Sound
 Auxiliary output relays (2) Level 2 upgrade kit
 Auxiliary configurable signal  Base barrier – elevated generator
inputs (8) and relay outputs (8) set
 Annunciator – RS485  Mufflers – industrial, residential or
critical

Control system PowerCommand 1.1


 Fail to crank shutdown
 Redundant start disconnect
 Cranking lockout
 Sensor failure indication
 Low fuel level warning or shutdown
Alternator data
 Line-to-Line and Line-to-neutral AC volts
 3-phase AC current
PowerCommand control is an integrated generator set  Frequency
control system providing voltage regulation, engine protection,
 Total kVa
operator interface and isochronous governing (optional). Major
features include: Engine data
 Battery monitoring and testing features and smart starting  DC voltage
control system.  Lube oil pressure
 Standard PCCNet interface to devices such as remote  Coolant temperature
annunciator for NFPA 110 applications.  Engine speed
 Control boards potted for environmental protection. Other data
 Control suitable for operation in ambient temperatures from  Generator set model data
-40 °C to +70 °C (-40 °F to +158 °F) and altitudes to 5000
 Start attempts, starts, running hours
meters (13,000 feet).
 Fault history
 Prototype tested; UL, CSA, and CE compliant.
 RS485 Modbus® interface
 InPower™ PC-based service tool available for detailed
diagnostics.  Data logging and fault simulation (requires InPower
service tool)
Operator/display panel
Digital governing (optional)
 Manual off switch
 Integrated digital electronic isochronous governor
 Alpha-numeric display with pushbutton access for viewing
engine and alternator data and providing setup, controls and  Temperature dynamic governing
adjustments (English or international symbols) Digital voltage regulation
 LED lamps indicating generator set running, not in auto,  Integrated digital electronic voltage regulator
common warning, common shutdown, manual run mode and  2-phase Line-to-Line sensing
remote start  Configurable torque matching
 Suitable for operation in ambient temperatures from Control functions
-40 °C to +70 °C
 Time delay start and cooldown
 Bargraph display (optional)
 Cycle cranking
AC protection
 PCCNet interface
 Over current warning and shutdown
 (2) Configurable inputs
 Over and under voltage shutdown
 (2) Configurable outputs
 Over and under frequency shutdown
 Remote emergency stop
 Over excitation (loss of sensing) fault
 Automatic Transfer Switch (ATS) control
 Field overload
 Generator set exercise, field adjustable
Engine protection
 Overspeed shutdown
 Low oil pressure warning and shutdown
 High coolant temperature warning and shutdown
 Low coolant level warning or shutdown
 Low coolant temperature warning
 High, low and weak battery voltage warning
 Fail to start (overcrank) shutdown

power.cummins.com
©2017 Cummins Inc. | NAS-6092-EN (10/17)
Options  Digital governing
 Auxiliary output relays (2)  AC output analog meters (bargraph)
 Remote annunciator with (3) configurable inputs and - Color-coded graphical display of:
(4) configurable outputs - 3-phase AC voltage
 PMG alternator excitation - 3-phase current
 PowerCommand 500/550 for remote monitoring and - Frequency
alarm notification (accessory) - kVa
 Auxiliary, configurable signal inputs (8) and  Remote operator panel
configurable relay outputs (8)
 PowerCommand 2.3 control with AmpSentry protection

Ratings definitions
Emergency Standby Power (ESP):
Applicable for supplying power to varying electrical load
for the duration of power interruption of a reliable utility
source. Emergency Standby Power (ESP) is in
accordance with ISO 8528. Fuel Stop power in
accordance with ISO 3046, AS 2789, DIN 6271 and
BS 5514.
Limited-Time Running Power (LTP):
Applicable for supplying power to a constant electrical
load for limited hours. Limited Time Running Power (LTP)
is in accordance with ISO 8528.
Prime Power (PRP):
Applicable for supplying power to varying electrical load
for unlimited hours. Prime Power (PRP) is in accordance
with ISO 8528. Ten percent overload capability is
available in accordance with ISO 3046, AS 2789,
DIN 6271 and BS 5514.
Base Load (Continuous) Power (COP):
Applicable for supplying power continuously to a constant This outline drawing is for reference only. See respective
electrical load for unlimited hours. Continuous Power model data sheet for specific model outline drawing
(COP) in accordance with ISO 8528, ISO 3046, AS 2789, number.
DIN 6271 and BS 5514.
Do not use for installation design

power.cummins.com
©2017 Cummins Inc. | NAS-6092-EN (10/17)
Dim “A” Dim “B” Dim “C” Set weight*wet
Model mm (in.) mm (in.) mm (in.) kg (lbs.)
Open set
C45 N6 2489 (98) 1016 (40) 1473 (58) 989 (2180)
C50 N6 2489 (98) 1016 (40) 1473 (58) 989 (2180)
C60 N6 2489 (98) 1016 (40) 1473 (58) 1103 (2431)
C70 N6 2489 (98) 1016 (40) 1473 (58) 1111 (2449)
C80 N6 2489 (98) 1016 (40) 1473 (58) 1173 (2587)
C100 N6 2489 (98) 1016 (40) 1473 (58) 1233 (2719)
Weather protective enclosure
C45 N6 2489 (98) 1016 (40) 1473 (58) 1070 (2359)
C50 N6 2489 (98) 1016 (40) 1473 (58) 1070 (2359)
C60 N6 2489 (98) 1016 (40) 1473 (58) 1184 (2610)
C70 N6 2489 (98) 1016 (40) 1473 (58) 1192 (2628)
C80 N6 2489 (98) 1016 (40) 1473 (58) 1255 (2766)
C100 N6 2489 (98) 1016 (40) 1473 (58) 1315 (2898)
Sound attenuated enclosure Level 1
C45 N6 3023 (119) 1016 (40) 1473 (58) 1114 (2455)
C50 N6 3023 (119) 1016 (40) 1473 (58) 1114 (2455)
C60 N6 3023 (119) 1016 (40) 1473 (58) 1227 (2706)
C70 N6 3023 (119) 1016 (40) 1473 (58) 1236 (2724)
C80 N6 3023 (119) 1016 (40) 1473 (58) 1298 (2862)
C100 N6 3023 (119) 1016 (40) 1473 (58) 1358 (2994)
Sound attenuated enclosure Level 2
C45 N6 3454 (136) 1016 (40) 1473 (58) 1127 (2485)
C50 N6 3454 (136) 1016 (40) 1473 (58) 1127 (2485)
C60 N6 3454 (136) 1016 (40) 1473 (58) 1241 (2736)
C70 N6 3454 (136) 1016 (40) 1473 (58) 1249 (2754)
C80 N6 3454 (136) 1016 (40) 1473 (58) 1312 (2892)
C100 N6 3454 (136) 1016 (40) 1473 (58) 1372 (3024)

* Weights above are average. Actual weight varies with product configuration.

power.cummins.com
©2017 Cummins Inc. | NAS-6092-EN (10/17)
Codes and standards
Codes or standards compliance may not be available with all model configurations – consult factory for availability.
The Prototype Test Support
(PTS) program verifies the
performance integrity of the
The generator set is available
generator set design. Cummins
Listed to UL 2200, Stationary
products bearing the PTS
Engine Generator Assemblies.
symbol meet the prototype test
requirements of NFPA 110 for
Level 1 systems.
The generator set is certified to All low voltage models are CSA
International
International Building Code certified to product class
Building Code
(IBC) 2012. 4215-01.
This generator set is designed
in facilities certified to ISO 9001 Engine certified to U.S. EPA SI
and manufactured in facilities U.S. EPA Stationary Emission Regulation
certified to ISO 9001 or 40 CFR, Part 60.
ISO 9002.

Warning: Back feed to a utility system can cause electrocution and/or property damage. Do not connect to any building’s
electrical system except through an approved device or after building main switch is open.

For more information contact your local Cummins distributor


or visit power.cummins.com

©2017 Cummins Inc. All rights reserved. Cummins is a registered trademark of Cummins Inc. PowerCommand, AmpSentry, InPower and “Our energy working for you.” are trademarks of
Cummins Inc. Other company, product, or service names may be trademarks or service marks of others. Specifications are subject to change without notice.
NAS-6092-EN (10/17)

You might also like