Un coverage 8D Report
Un coverage 8D Report
Page No. : 1 of 3
8D Open Date : 05.12.2023
SUPPLIER NAME : HEBRON AUTOMOTIVE 8D Submission Date : 10.12.2023
8D Close Date : 14.12.2023
D1. PROBLEM DEFINITION DATE : 06.12.2023
D ACTION TAKEN TO DISPOSE NON -CONFORMING PARTS / ICA : Containtment action in process
Identification on
Part checkes at Date OK Not OK Mfg date & shift traceability for Rej qty
Ok part
2 In Transit or Godown - -
8D No :- 01 / 2023
CORRECTIVE & PREVENTIVE ACTION REPORT
Page No. : 2 of 3
Sr. No. Non Detection Root causes identified Action Plan PA CA Action By Target Date Comp. On
1 100% inspection not Effective Re Training to be provided concern inspectors √ Hariharan 12.12.2023 07.12.2023
plan
Non Calibration
method not ok Current FLow NO Instructions
Instrument used
not Sufficient Uncoverage
SQA/003 - 01
VALIDATION OF POTENTIAL ROOT CAUSE (Induce the cause where possible to reproduce the defect) DATE : 08.12.2023
Sr.No Potential Root Cause (shortlisted) Verification Validation Significant Non significant
3 PMI Carried out as per schedule PMI carried out as per plan PMI plan
4 Process Parameter Not Ok Verified the process parameters found OK Setup approval
WHY-WHY ANALYSIS of SIGNIFICANT CAUSES FOR CONVERGING INTO ROOT CAUSE (for Occurance)
8D No :- 01 / 2023
CORRECTIVE & PREVENTIVE ACTION REPORT
Page No. : 3 of 3
CORRECTIVE & PREVENTIVE ACTION PLAN:
D5. DATE : 09.12.2023
(Actions planned to avoid recurrence & to prevent potential causes)
Sr. No. Root causes identified Action Plan PA CA Action By Target Date Comp. On
Consider Yes No Comment (If Yes) along with referance of deployment plannification
Other similar parts Spray gun cleaning frequency reduced All Powder coating parts of Eyelet & Adjusters
Mr. Kumar, Mr. Hariharan, Mr. Sakthivel, Mr. Siddaraj, Mrs. Chebadevi, Mr. Arun
1 gun cleaning Confirmation of by supervisor . Have operetors donne cleaning of gunas per the rule?.
1st lot After Action Implementation 2nd lot After Action Implementation 3rd lot After Action Implementation
VERIFIED BY :- APPROVED BY :-
SQA/003 - 01