0% found this document useful (1 vote)
4 views

Hardware and Software Prerequisites En

This technical note outlines the hardware and software prerequisites for ENVEA software products, including eSAM, XR, and WEX servers. It details minimum hardware configurations, operating system requirements, and communication protocols necessary for installation and operation. The document serves as a guide for users to ensure compatibility and optimal performance of the software systems.

Uploaded by

f.ottavioli.qc
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (1 vote)
4 views

Hardware and Software Prerequisites En

This technical note outlines the hardware and software prerequisites for ENVEA software products, including eSAM, XR, and WEX servers. It details minimum hardware configurations, operating system requirements, and communication protocols necessary for installation and operation. The document serves as a guide for users to ensure compatibility and optimal performance of the software systems.

Uploaded by

f.ottavioli.qc
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

230 Allée Théodore Monod –Technopole Izarbel – 64210 BIDART – FRANCE

 Tel. : +33 (0)5 59 41 55 66  [email protected]  www.envea.global

Technical Note
Hardware and Software
Prerequisites

   Non-contractual document and may be modified without prior notice

Version no. 2.13 10th Oct. 2024

Document Ref.: 21-0759

Number of pages: 11

Author: Patrice BONNET

   This document is the property of ENVEA and may not be communicated to third parties without written authorization
Technical Note Hardware and Software Prerequisites

TRACEABILITY – DOCUMENT VERSION


PAGES OR §
DATE VERSION AUTHOR CONCERNED MODIFICATIONS
20/03/2015 V1.0 KMI Document creation
21/11/2016 V1.1 YST §1 & §2 Changing paragraph
13/12/2016 V2.0 PBT All Rewriting the document
12/01/2017 V2.1 PBT §1 Add Hard disk limit
31/01/2017 V2.2 PBT §2 Memory for 64-bits O.S.
24/05/2017 V2.3 PBT §2.1 XP O.S.
20/10/2017 V2.4 PBT §3 Add used protocol (IP/RS)
20/04/2018 V2.5 PBT §4.1 Add this §
09/05/2018 V2.6 DSE §4.2 Add this §
Add eSAM 6.5 & Server 6.5
22/05/2018 V2.7 MSA §2.1
32-bits
03/10/2018 V2.8 PBT §1.1 Update need in RAM
31/01/2019 V2.9 PBT ADAM 4055 info. correction
31/03/2019 V2.10 PBT ADAM 6050 info. correction
21/04/2022 V2.11 PBT Updating document template
21/04/2022 V2.12 PBT Memory for 64-bits O.S.
10/10/2024 V2.13 PBT §2.1 Add Server 7.0

21-0759 Page | 2
Technical Note Hardware and Software Prerequisites 1. Hardware prerequisites

Contents

1. HARDWARE PREREQUISITES 5
1.1 XR Premium & eSAM 5
1.2 WEX 5

2. SOFTWARE PREREQUISITES 6
2.1 Operating system 6
2.2 Web browsers 6

3. ESAM DAS INPUT / OUTPUT PREREQUISITES 7


3.1 Analog Inputs 7
3.2 Analog Outputs 7
3.3 Digital Inputs 7
3.4 Digital outputs 8
3.5 Counter Input 8
3.6 Serial ports 8

4. COMMUNICATION 9
4.1 Server - SAM Communication 9
4.1 Remote Access to the DAS through the eSAM WEB interface 9
4.2 Firewall settings 10
Incoming rules 10
Outgoing rules 11

21-0759 Page | 3
Technical Note Hardware and Software Prerequisites 1. Hardware prerequisites

NOTE
This manual contains the hardware and software prerequisites for all ENVEA software products.
This includes eSAM software for the data acquisition system (DAS), XR and WEX servers and related
software (WorkStation, SPC, ...). The prerequisites are valid for all software versions higher than and
including 6.2.
Please read this manual before installing your ENVEA software. If you need to prepare a
configuration not documented, please contact us.

Copyright
This document is the property of ENVEA and may not be sent to third parties without written
authorization.
This is a non-contractual document and may be modified without prior notice.

21-0759 Page | 4
Technical Note Hardware and Software Prerequisites 1. Hardware prerequisites

1. Hardware prerequisites
The hardware requirements must be adapted to suit your needs; these are minimum configurations.

1.1 XR Premium & eSAM

The following table lists the prerequisites for installing XR and eSAM software.

ITEMS XR PREMIUM eSAM


Processor Type Intel i5 - 6400 minimum Intel i3 - 3240 minimum
Memory(*1) 16 GB minimum 8 GB minimum
32 GB recommended 16 GB recommended
Hard Disk(*2) 500 GB minimum, 2 TB Max. 250 GB minimum
Network Ethernet board Ethernet board

Optional Serial port, Ethernet board,


PCIe depending on the
inputs/output prerequisites
(*1)
Refer to the operating system prerequisites,
(*2)
Oracle does not install if there is more than 2 tera-byte of available disk space

1.2 WEX

The hardware architecture of WEX system on an industrial site consists of two types:
• Centralized architecture: 1 PC with three software WEX CORE, WEX WorkStation and eSAM ;
• Distributed architecture: 1 PC with WEX CORE and WEX WorkStation, 1 PC with eSAM.
Depending on the architecture, the prerequisites for the WEX CORE and WEX WorkStation are presented
below:
DISTRIBUTED
DISTRIBUTED 2 MAIN STACK
ITEMS CENTRALIZED 1 LINE + BACKUP
Processor Type Intel i5 - 6400 minimum
Memory(*1) 16 GB minimum
32 GB recommended(*4)
Hard Disk(*2) 1To minimum
Network(*3) 2 Ethernet board 2 Ethernet board 2 Ethernet board
Monitor 24-inch Full HD 24-inch Full HD 24-inch Full HD
(*1)
Refer to the operating system prerequisites
(*2)
Oracle does not install if there is more than 2 tera-byte of available disk space
(*3)
An additional network card can be used to separate the three networks: Internet network, factory
network (MODBUS, OPC, etc.) and network analyzer.
(*4)
Minimum memory when using an SSD disk (no SWAP) or more than 400 channels.

21-0759 Page | 5
Technical Note Hardware and Software Prerequisites 2. Software prerequisites

2. Software prerequisites
2.1 Operating system

The following table lists the operating system prerequisites for installing XR or WEX or eSAM.
Server
eSAM 6.5 Server Server Workstation
eSAM 6.4 7.0 and
and above 6.2 to 6.4 6.5 software
OPERATING SYSTEM above

Windows™ Pro 32-bits


(*1)
(7 & 8 & 10)

Windows™ Server 32-bits


(2003)

Windows™ Pro 64-bits


(*2)
(7 & 10)

Windows™ Server 64-bits


(*2)
(2008 – 2012 – 2016)

Windows™ 10 IoT 64-bits (*3) (*3) (*3)

Windows™ 11 Pro 64-bits (*3) (*3) (*3)

Windows™ 11 IoT 64-bits (*3) (*3) (*3)

Windows™ Server 2019 & 2022


(*3)
(64-bits)

(*1)
Server 6.5 in 32-bits version
(*2)
Server 6.5 in 64-bits version
(*3)
Version after June 2023

2.2 Web browsers

The following table lists the Web browsers supported by the web interface included in ENVEA
software.

WEB BROWSER Supported


Microsoft Edge
Chrome 110+
(*1)
Firefox
Internet Explorer 10 & 11
(*1)
Not tested

21-0759 Page | 6
3. eSAM DAS input / output
Technical Note Hardware and Software Prerequisites
prerequisites

3. eSAM DAS input / output prerequisites


In the basic configuration, the eSAM software will use the Ethernet port of the computer in order to
communicate over TCP/IP with IP analyzers.
If you need a RS232, RS485 or analog connection to the analyzers you must install one of the
additional modules which are listed here bolow:

3.1 Analog Inputs

A eSAM DAS can have a maximum of 64 analog inputs distributed over a combination of ADAM
modules.
Each ADAM module has a maximum number of analog inputs.

MAXIMUM NUMBER OF
ADAM MODULE CONNECTION
ANALOG INPUTS
4017 RS485 8
6017 TCP/IP 8
5017 TCP/IP 8
5017P TCP/IP 8

3.2 Analog Outputs

A eSAM DAS can have a maximum of 32 analog outputs distributed over a combination of ADAM
modules.
Each ADAM module has a maximum possible analog outputs.
MAXIMUM NUMBER OF
ADAM MODULE CONNECTION
ANALOG OUTPUTS
4024 RS485 4
6024 TCP/IP 2
5024 TCP/IP 4

3.3 Digital Inputs

A eSAM DAS can have a maximum of 96 digital inputs distributed over a combination of ADAM
modules.
Each ADAM module has a maximum possible a digital inputs.
Some ADAM modules provide digital inputs and digital outputs.
MAXIMUM NUMBER MAXIMUM NUMBER
ADAM MODULE CONNECTION OF OF DIGITAL
DIGITAL INPUTS OUTPUTS
4051 RS485 16 -
4055 RS485 8 8
6050 TCP/IP 12 6
6051 TCP/IP 12 Not implemented!
6060 TCP/IP 6 6
5051S TCP/IP 16 -

21-0759 Page | 7
3. eSAM DAS input / output
Technical Note Hardware and Software Prerequisites
prerequisites

3.4 Digital outputs

A eSAM DAS can have a maximum of 64 digital outputs distributed over a combination of ADAM
modules.
Each ADAM module has a maximum possible a digital outputs.
Some ADAM modules provide digital inputs and digital outputs.
MAXIMUM NUMBER MAXIMUM
ADAM MODULE CONNECTION OF NUMBER OF
DIGITAL INPUTS DIGITAL OUTPUTS
4055 RS485 8 8
6050 TCP/IP 12 6
6060 TCP/IP 6 6
5068 TCP/IP - 8

3.5 Counter Input

A eSAM DAS can have a maximum of 96 digital inputs distributed over a combination of ADAM
modules.
Each ADAM module has a maximum possible a Counter inputs.
MAXIMUM NUMBER OF
ADAM MODULE CONNECTION
COUNTER INPUTS
6051 TCP/IP 12

3.6 Serial ports

A eSAM DAS can have a maximum of 32 Serial ports(*1) distributed over a combination of MOXA
equipment and system serial ports.
MOXA EQUIPMENT CONNECTION NUMBER OF PORTS
MOXA NPort TCP/IP 1 to 32(*2)
MOXA UPort USB 1 to 16(*2)
MOXA PCI Cards CP-168U PCI 8(*3)

(*1)
in the Windows™ operating system the ports available for connection are port numbers 1 to 32
inclusive.
(*2)
Chose from models with 1, 2, 8, 16 or 32 ports.
(*3)
Two PCI cards maximum.

21-0759 Page | 8
Technical Note Hardware and Software Prerequisites 4. Communication

4. Communication
4.1 Server - SAM Communication

Several types of communication can be used for communication between the XR/WEX server and the
data acquisition eSAM: analog (phone network), cellular (GSM/GPRS), router 3G/4G, Ethernet (IP)
and ADSL.
It is strongly recommended that you use the recommended hardware, ENVEA does not take
responsibility for malfunctioning with other equipment.

COMMUNICATION TYPE RECOMMENDED HARDWARE


MultiTech modem MT5656ZDX
Analog modem
Analog modem 56K V.92
Cellular modem MultiTech modem HTC-G3 GSM/GPRS
Router modem 3G/4G Router modem MultiTech MTR-H6
Ethernet Native 10/100/1000 Mbps
Netgear modem DM111P ADSL 2+
ADSL
& Netgear Router FVS318G

4.1 Remote Access to the DAS through the eSAM WEB interface

You can visualize the data remotely with a web browser through the web interface of the eSAM
Software.
If the eSAM is on your local network then use a standard web browser (Chrome, Firefox,…) and type
the IP address of your eSAM (see the documentation of the eSAM).
If you want to connect remotely to your eSAM from outside of your local network you need the following:
• Permanent Internet access at the place where you use the WEB browser.
• Router-modem 3G/4G (ref. Multitech MTR-H6 ) to be connected to the Data Acquisition System.
• Data mobile subscription for this router-modem. This must be a “M2M” type data subscription
with a Public IP address.
The Public IP address which will be given with this data subscription can be FIXED or most
DYNAMIC (a dynamic IP address can change over the time)
• If the Public IP address is DYNAMIC, you must subscribe to a service like DynDNS
(https://cart.dyn.com/checkout/#/) which will make the IP fixed so that you can reach the DAS
through the internet network even if the IP address has changed.
• If the public IP address is FIXED, there is no need to subscribe to a service like DynDNS.
Then you should configure your router-modem in order to open and secure the connection.

21-0759 Page | 9
Technical Note Hardware and Software Prerequisites 4. Communication

4.2 Firewall settings

Each product use communication protocols with specific network ports to work fine. All given rules in
the following table needs to be availables. The ENVEA products setup integrates the Windows
Firewall configuration.

Incoming rules
PRODUCT VERSION PROCESS PROTOCOL PORT
XR/WEX All C:/iseo/SRV/bin/Alarme_httpDMS.exe TCP/UDP All
XR/WEX All C:/iseo/SRV/bin/ligne.exe TCP/UDP All
XR/WEX All C:/iseo/SRV/bin/ModbusIP.exe TCP/UDP All
XR/WEX All C:/iseo/SRV/bin/SysManager.exe TCP/UDP All
C:/Oracle/product/12.1.0/dbhome_1/BIN/TNS
XR/WEX All TCP/UDP All
LSNR.EXE
C:/Oracle/product/12.1.0/dbhome_1/BIN/sqlpl
XR/WEX All TCP/UDP All
us.EXE
XR/WEX All C:/iseo/SRV/tomcat/bin/tomcat7.exe TCP 8080,8443(*1)
XR/WEX
C:/Program Files
(Backup All TCP/UDP All
(x86)/FileZilla_Server/FileZilla Server.exe
system)
XR/WEX
(Backup All C:/Windows/system32/ftp.exe TCP/UDP All
system)
SAM/eSAM
All C:/iseo/SAM/bin/httpd.exe All All
FT Controller
SAM/eSAM
All C:/iseo/SAM/bin/modbusIPMaster.exe TCP 502
FT Controller
SAM/eSAM
All C:/iseo/SAM/bin/protocole.exe All All
FT Controller
SAM/eSAM
All C:/iseo/SAM/bin/server_http.exe TCP All(*2)
FT Controller
SAM/eSAM
All C:/iseo/SAM/bin/StateFileServer.exe TCP 3600
FT Controller
SAM/eSAM
All C:/iseo/SAM/bin/transparent.exe TCP 5010
FT Controller
eSAM From v6.4 C:/iseo/SAM/bin/nodejs/node.exe TCP All

FT Controller All C:/iseo/SAM/bin/Comserver.exe TCP 8010

21-0759 Page | 10
Technical Note Hardware and Software Prerequisites 4. Communication

Outgoing rules
PRODUCT VERSION PROCESS PROTOCOL PORT
XR/WEX From v6.5 C:/iseo/SRV/bin/java/mqttSubscripter.jar TCP/UDP 1883,8883(*3)

C:/iseo/SAM/bin/Client_subscripter.exe
SAM/eSAM From v6.5 TCP/UDP 1883,8883(*3)
C:/iseo/SAM/bin/Client_publisher.exe
(*1)
Port used by eWorkstation
(*2)
Used for http protocol, by default port 3500 is used.
(*3)
Used for MQTT protocol

21-0759 Page | 11