Vacuum line
Vacuum pumps and
pre-evacuation units
Vacuum line
Vacuum pumps
Since 1940, Galileo’s vacuum pump line has provided top quality and cost effective vacuum pumps for
both industrial and scientific applications. Galileo’s dual stage rotary vane vacuum pumps are available in
two different series:
Vacsound Modular
Multi-purpose line for up to For wider pumping applications
28 m3/h (22 cfm) applications up to 80 m3/h
Galileo pumps feature a special anti-suck back Each pump is leak tested with helium and is
device that isolates the vacuum systems when the equipped with high flow gas ballasts to increase
pump is stopped, preventing any contamination of performance when operating with condensable
the product while being processed. gases or water vapor.
The temperature is kept constant in every A built-in trap limits the amount of oil that reaches
section of the pump thanks to a streamlined the exhaust port.
forced ventilation and lubrication system, which
results in achieving better performance, reduced Each Galileo pump can be supplied with a wide
maintenancedowntime and cost reductions. range of fittings and accessories such as outlet
filters, including high-efficiency options with oil
The items are manufactured with high precision vapor recovery.
tooling machines and high quality raw materials for
enhanced service life.
2
\\ Ascential Brochure
Vacsound Modular
Vacsound
Units A B C H L M N P R W
MODULAR
Units A B C H L M N P R W Z
galileotp.com 3
Vacuum line
Vg502 Units Hz
The VG502 vacuum gauge has the capability The VG502 vacuum gauge can enable a gas
of measuring either vacuum (down to 10-3 mbar) ballast valve to clean the pump periodically when
or pressure (up to 160 bar), depending on the it’s contaminated with condensed vapors.
sensor that is installed (see technical data).
The VG502 also has also the following features:
VG502 displays the pressure read on channel A,
B or alternatively displays the most accurate read s Easy programming with touch panel or
by merging the two channels. remotely via PC with serial protocol RS232;
s Integration with RECDATA TJ V to manage
The VG502 can work as a stand-alone one or more VG in a carousel line to display
instrument or an integrated system with RecData vacuum curve, report and cycle. The
TJ V. The VG502 vacuum gauge can operate in connection of each vacuum gauge to the
one of three modes: PC with the software Recadata TJ V can be
done via RS485 or via Wi-Fi module/protocol;
s Set Point: standard working mode, the s Digital I/O for field/line communication (pass,
VG502 acts as a measurement instrument fail contact) and remote control (start, stop
s Time: the vacuum must be reached in a remote input).
selected time
s Pressure Rise Test: when the LOW set point
is reached, the interception valve is closed
and the rise curve monitored (optional mode)
4
\\ Ascential Brochure
Since 1940
Galileo’s
galileotp.com 5
Vacuum line
Diagnovac/Vg
The highly flexible pumping groups
Diagnovac has been designed to meet the requirements
of pre-evacuation and drying phases for refrigerant units
in production lines with either fixed or mobile carousels.
Various models are available depending on the required pump
(all the Vacsound and Modular models can be fitted in the
Diagnovac), the number of inlets (one for Diagnovac 1, two
for Diagnovac 2) and the required supply voltage 3-phase.
Diagnovac can be supplied with the VG502 vacuum gauge
to perform a vacuum cycle (Diagnovac 1VG with one inlet,
Diagnovac 2VG with two inlets) that lasts until the evacuation
time or the set point.
The system performs leak detection with the pressure rise method, using an interception valve (Vacuum
Interception Valve) and a VG502 vacuum gauge connected to a PIRANI device (pressure sensor) on a single
refrigeration circuit. The LCD screen will feature the results of the cycle. If the vacuum is better than the
programmed set point, a “Pass” message will be displayed.
RecData TJ V
RecData TJ V is a PC software that manages the
vacuum stations of cooling units. The test is carried out
by collecting the vacuum level from VG502 vacuum
gauges either with fixed stations or mobile carousels.
It is possible to set different working cycles for different models and to manage the vacuum rise test.
The test may last from one second up to a maximum of 9 hours. All the performed tests are stored in a
SQL database.
RecData TJ V is completely integrated with the GEDA system for data acquisition and statistics, as well as
external supervision of the line.
6
\\ Ascential Brochure
Pre-evacuation units
galileotp.com 7
+39 055 722 13 58 | [email protected]
galileotp.com