0% found this document useful (0 votes)
3 views

Laboratory and Problem Set

The document outlines a series of laboratory assignments for BSCE 4A and 4B students, focusing on the design of various components of welded Howe and riveted Fink trusses using AISC specifications and ASTM A36 steel. Each laboratory has specific design problems, including ceiling joists, purlins, top and bottom chords, and joints, with detailed requirements for material properties and dimensions. Deadlines for each laboratory are specified, with all submissions due by 12 PM on the indicated dates in December 2023.

Uploaded by

Koalatzy.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3 views

Laboratory and Problem Set

The document outlines a series of laboratory assignments for BSCE 4A and 4B students, focusing on the design of various components of welded Howe and riveted Fink trusses using AISC specifications and ASTM A36 steel. Each laboratory has specific design problems, including ceiling joists, purlins, top and bottom chords, and joints, with detailed requirements for material properties and dimensions. Deadlines for each laboratory are specified, with all submissions due by 12 PM on the indicated dates in December 2023.

Uploaded by

Koalatzy.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

BSCE 4A

Laboratory No. 4 (December 1, 2023, 12PM only) Design of Ceiling Joist


Problem: Design the ceiling joist of your welded Howe Truss using W Shape AISC Specs and ASTM A36
Steel. Use min d=L/30 where L is the beam, spacing of ceiling joist is equal to 1m. Assume Laterally
supported.

Laboratory No. 5 (December 6, 2023, 12 PM Only) Design of Purlins


Problem: Design the purlins, sag rod and tie rod of your welded howe truss using LC shape with sagrods
each third points, there should be purlins on every joint and the spacing of purlins should be controlled
by the allowable span of roof covering which is equal to 1.52m use min d=L/30. Use AISC Specifications
and allowable bending stress to be Fb=0.6Fy.

Laboratory No. 6 (December 8, 2023, 12PM only) Design of Top Chord


Problem: Design the top chord of your welded howe truss using Channel Section, for the load
transmitted by the purlins to the top chord see your laboratory no. 5. Use F b=148.8 MPa. ASTM A36 Steel
and AISC Specifications need to be used.

Laboratory No. 7 (December 12,2023, 12PM only) Design of Bottom Chord


Problem: Design the bottom chord of your welded howe truss using Channel Section,Use F b=148.8 MPa.
ASTM A36 Steel and AISC Specifications need to be used. Assume that the load transmitted by the ceiling
joist to the bottom chord is distributed uniformly (Since spacing of ceiling joist is 1m) see lab 4.

Laboratory No. 8 (December 18, 2023, 12PM only) Design of Joints


Problem: Determine the size/thickness of weld and base plate needed on every joint of your welded
howe truss. Use A36 steel use AISC Specifications for all assumptions. Use thickness of plate as 10mm
adjust accordingly based on your design specifications.

BSCE 4B

Laboratory No. 4 (December 1, 2023, 12PM only) Design of Ceiling Joist


Problem: Design the ceiling joist of your riveted fink truss using W Shape AISC Specs and ASTM A36
Steel. Use min d=L/30 where L is the beam, spacing of ceiling joist is equal to 1m. Assume Laterally
supported.

Laboratory No. 5 (December 6, 2023, 12 PM Only) Design of Purlins


Problem: Design the purlins, sag rod and tie rod of your riveted fink truss using LC shape with sagrods
each third points, there should be purlins on every joint and the spacing of purlins should be controlled
by the allowable span of roof covering which is equal to 1.52m use min d=L/30. Use AISC Specifications
and allowable bending stress to be Fb=0.6Fy.

Laboratory No. 6 (December 8, 2023, 12PM only) Design of Top Chord


Problem: Design the top chord of your riveted fink truss using Channel Section, for the load transmitted
by the purlins to the top chord see your laboratory no. 5. Use F b=148.8 MPa. ASTM A36 Steel and AISC
Specifications need to be used.

Laboratory No. 7 (December 12,2023, 12PM only) Design of Bottom Chord


Problem: Design the bottom chord of your riveted fink truss using Channel Section,Use F b=148.8 MPa.
ASTM A36 Steel and AISC Specifications need to be used. Assume that the load transmitted by the ceiling
joist to the bottom chord is distributed uniformly (Since spacing of ceiling joist is 1m) see lab 4.

Laboratory No. 8 (December 18, 2023, 12PM only) Design of Joints


Problem: Determine the size/thickness of rivets and base plate needed on every joint of your riveted fink
truss. Use A36 steel use AISC Specifications for all assumptions. Use thickness of plate as 10mm adjust
accordingly based on your design specifications.