For ammonia vapor, at Tavg = 80°C; CPG = 2.418 kJ/kg-°C, kG = 0.0317 W/m-°C, µG =
1.2 x 10–5 kg/m-s, ρG = 4.03 kg/m3.
Design the proposed shell and tube heat exchanger and evaluate the overall heat transfer
coefficient for the above duty
B) Estimate the heat transfer area required and the pressure drop for the above problem. Is
the calculated required area within the 30% overdesign limit in comparison with the
available surface area? (4)
C) Is the proposed design suitable for the duty of above problem? If not, recommend the
suitable changes for an efficient operation of heat transfer (2)
2) A horizontal 1-2 condenser is required for the complete condensation of 25000 kg/h
saturated vapor of pure n-propanol (propyl alcohol) at 117⁰C, coming from the top of the
distillation column operating at 15 psi(g). Cooling water is available at 30⁰C and was (4)
A) heated to 50⁰C during condensation. Tubes of 3/4 in. OD, 16 BWG, 8 ft length on
triangular pitch are available for the design. Assume the tube wall resistance is
1 of 3 25-04-2024, 18:26
CHE 3251 about:srcdoc
negligible. Fouling resistance value of 0.0002 can be considered for n-propanol and
water. The properties are given as:
Design a horizontal 1-2 condenser for the above duty and perform the shell and tube side
calculations.
B) Evaluate the actual overall heat transfer coefficient value and pressure drop on both side
for the above problem. (4)
C) Is the design acceptable for the above duty? if not, recommend the possible changes.
(2)
B) Evaluate the steam economy of the evaporator for the above problem.
(3)
C) Determine the total capacity of the designed evaporator in the above problem
(2)
4) A saturated vapor feed mixture containing 35% benzene, 35% toluene and 30% cumene
(all mole %) is to be fractionated at a rate of 100 kmol/h to recover 98% benzene in
distillate and 98.5% toluene in bottom product. Constant molar flow rate and ideal
A) solution behaviour may be assumed. The column top temperature is 80.5°C and bottom (3)
temperature is 124°C. Also, the vapor pressure (mm Hg) as a function of Temperature
(K) of all three components are given as:
2 of 3 25-04-2024, 18:26
CHE 3251 about:srcdoc
B) Determine the minimum number of stages required and minimum reflux ratio for the
above problem. (4)
C) For the above problem, evaluate the number of ideal stages required and locate the feed
tray for this multicomponent distillation system (3)
B) Determine the standard thickness of shell if stiffeners are used (with 0.8 m spacing).
(4)
C) Is the calculated thickness safe against plastic deformation in both the cases? If not, then
recommend the changes. (2)
-----End-----