ICE Maker User Manual V1 2021 1
ICE Maker User Manual V1 2021 1
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Fault Self-diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Fault Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
-1-
ICEQ55Z ICEQ210Z
Model nameplate
Display screen
Front panel
Supporting foot
Power switch
(optional)
-2-
Model label
Water cooling
configuration/ customization
-3-
6. ice making machine should not be installed in the
environment without sewer and water seepage, and it is
strictly prohibited from high temperature equipment.
-4-
ICEQ55Z ICEQ210Z Installation
Sewer inlet
Ice water
Drain pipe The filter cover
Filter core must be taken out before Pure water Tap water
use, tearing off the packaging film and
tightening it back
Air cooled
ice maker
*Caution *Caution
then connected with the 4/6 hose, and Ice water outlet
pip e
Condensation water inlet
Ice water inlet pipe
ani ng dra in
pipe(water cooling)
d ra in
ag e bi n
e r c o n w a te r
Ic e st or
)
o l in g
Aut om atic cle
o
p i p e e n s a ti
(wat
d
Con
* Caution * Caution
*Caution
Note: Unplug the power supplies after finishing the day's work .
Ⅰ. Button instruction
A. There are five tangibly buttons below the control
panel
2. Press the button in the status of manual clean, machine go to drain step and then enter into
rinsing process after drain finished. Press the button in the status of rinsing, machine will go
to drain and then go to next procedure.
3. Press the button goes to manual clean, in the status of ice freezing, ice harvest and ice
full .
c.Schedule/+ button
1. Press it to enter time schedule setting when power OFF.
2. In the status of time schedule setting, press the button to increase 10 minutes, long
pressing to increase time continuously.
3. In the status of setting, press the button to increase one of the parameter, long pressing to increase
continuously.
d. Light/- button
1. In the status of setting, press the button to reduce one of the parameter, long press to reduce
continuously.
2. In the status of time schedule setting, press the button to reduce 10 minutes, long press to reduce
continuously.
3. In the status of non set , press the button to turn on/off the blue light.
Ⅱ. LCD control panel status instructions (Drawing instruction)
-8-
1. Switch on: LCD control panel lights up.
2. Switch on time-delay:
Water inlet: Display time C00, icons of Clean, Freezing, Ice cube harvest and Ice full of
storage light up.
Switch on clean: Display time is cleaning time, Clean icon lights up.
Pressure balance: Icons of Clean, Freezing, Ice cube harvest and Ice full of storage light
up. If condenser sensor had fault, Fault icon lights up, Condenser sensor icon
lights up, temperature displays EE.
3. Manual clean: Clean icon flashes. Displays time is cleaning time.(It will not display
icon, if the programhas no cleaning function..
Display time is ice freezing time. After entering the countdown program, it displays
remaining time for ice making. In the status of delayed shutting down, Freezing icon
flashes.
If condenser sensor had fault, Fault icon light on, Condenser sensor icon lights
up, temperature displays EE.
5. Ice harvest: Ice cube harvest icon light up. Display time is ice cube harvest time.
In the status of delayed shutting down , Ice cube harvest icon flashes.
If condenser sensor had fault, Fault icon lights up, Condenser sensor icon lights up,
temperature displays EE.
6. Ice full: Ice full of storage icon lights up. Display time is ice full time. All the load works
will be turned off.
Ice full of storage icon works with ice chute board. When the ice chute board close,
Ice full of storage icon lights up, Ice full of storage icon goes out when ice chute
board opens. No button pressed for 60 seconds, screen locked, screen lock icon lights
up. Press any key to unlock.
Ice full is released (compressor is on delayed status), Ice full of storage icon flashes, turn
on delay. If condenser sensor had fault, Fault icon light on, Condenser sensor
icon lights up, temperature displays EE.
-9-
7. Fault: Fault icon lights up, corresponding fault status icons light on. All the load
works will turn off.
9. Schedule time setting: Time schedule icon lights up. Display time is the schedule time
to turn on the machine.
10. Schedule status: All icons of Clean, Freezing, Ice cube harvest, Ice full of
storage light up. Time schedule icon flashes. Displaying scheduled time
counts down.
11. Condenser fault, Fault icon lights up, Condenser sensor icon lights up, and the
machine working.
12. Ice chute board or ice full switch faults, Ice flip lights up, Fault icon flashes.
13. Overtime ice making fault, if it happens 10 times consecutively, Freeze overtime icon
lights Fault icon flashes.
14. Overtime ice harvest fault, if it happens 3 times consecutively, Harvest overtime icon
lights Fault icon flashes.
16. Water shortage fault, after 4 minutes water inputting continuously, water is still
not full, Water shortage icon lights up and Fault icon flashes.
17. High pressure fault, HP switch open (the function is invalid without HP switch),
High pressure icon lights up and Fault icon flashes.
-10-
Ⅲ. Several frequently-used procedures setting for your reference. Please operate as
the following steps when you need.
A. How to adjust the thickness of the ice?
Step 1.When the is on making ice model. Press the discretional one of the five buttons to
unlocked.
Step 2. Press Schedule/+ button, the position which displays temperature will flash “00”.
-11-
Step 3. Press Schedule/+ button and Light/- button to adjust. Press Schedule/+
button for one time,the position which displays temperature will appear “01” as
the following picture. It means the ice making time will be increased 1 min, the ice will
become thick.
Press Light/- button for one time,the position which displays temperature will
appear “-1” as the following picture. It means the ice making time will be reduced
1 min, the ice will become thin. After setting, you need no other operation, the
machine will resume making ice automatically.
-12-
B. How to clean the machine?
Step 1. Press the discretional one of the five buttons to unlocked.
Step 2. Press On/Off button, the control panel will appear 'OFF' as the following
picture.
Step 3. Press Clean/Set button, the control panel will display clean pattern.
Usually, 2 minutes to clean the machine is enough.
-13-
C. How to set the program when the ice storage is full?
When the ice storage is full, the control panel will display'full
ice‘pattern as the following picture.
Step 1. Use ice shovel to clean the ices which cover on the ice chute board.
Step 2. Press the discretional one of the five buttons to unlocked.
Step 3. Press On/Off button to turn off the machine, the control panel will
appear'OFF'. Step 4. Press On/Off button to turn on the machine, then press 3
times Model button to back to making ice model.
-14-
Ice Thickness Adjustment Instruction
When the water is circulating, the compressor works to cool down the ice
lattice. The water will gradually cool to 0 degree celsius. The ice will appear
and thicken in the ice lattice.
The narrow gap between the detector and the ice lattice will reduce to a
certain extent, the water which passes through the pipe comes into the gap
and contact with the metal detector, detector signal detects the circuit
control chip for more than 8 seconds, it means completing the process of
making ice. So the gap between the detector and the ice lattice is the key to
control the ice thickness.
Adjusting screw clockwise to increase the thickness of the ice, adjusting screw
counter-clockwise to reduce the thickness of the ice. Every adjustment
should not exceed half a lap, and you can see the effect of the ice after the
adjustment.
-15-
Routine Cautions
1. When transportation and mobile location, the ice machine tilt shall not
exceed 45 degrees.
2. Ice machine, please use independent water source, and check regularly
to prevent water pressure is too low, fluctuations or filter clogging.
3. Do not store any sundries in the ice storage room, or freeze any food in
the ice storage room and keep the ice shovel clean.
4. Switch the ice storage bucket plastic door, should be light open and
light closed, don't beat box door, after taking the ice, please turn off the
sliding door of the ice storage bucket.
5. Ice machine should be far away from the heat source. It is strictly
prohibited to use in high temperature or low temperature environment. It
is necessary to avoid direct sunlight in order to avoid affecting the heat
dissipation of the machine.
6. It is forbidden to wash the surface of ice machine directly with water,
otherwise it may lead to short circuit, leakage and other faults.
7. After the ice machine is used for a period of time, if it is stopped for a
long time, it should be electrified every two months for four to six hours.
2. Cleaning of the shell can be cleaned with a neutral cleaning agent, and
then wipe clean with a rag which is made of soft material. Commercial
stainless steel cleanser and polishing agent can be used when necessary.
3. Filter element should be checked regularly. Most of the ordinary filter
element is replaced in half a year, and the senior core should be replaced on
time according to the description.
4. Water pipes can be washed directly when the water tank and the ice
storage barrel are cleaned. Do not let water pressure is too large, do not
directly flush the water pump and the above part of the ice, to prevent the
leaching circuit part.
Fault self-diagnosis
1. Pump -- can directly observe whether there is water from the ice grid
up, if there is no pump failure.
2. Refrigeration--after 10 minutes of ice making, the water in the sink will
be significantly cooler, and you can feel the water temperature directly by
touching the ice grid or running water.
3. Influent-- one by one in the automatic cleaning process can be
observed in the tank overflow pipe constantly flowing into the ice storage
tank. In the process of ice making, you can put your hand into the water
tank to feel the amount of water, the normal situation accounts for more
than half of the sink.
-18-
Fault Possible Cause Solution
The cover of ice tray does not reset. Adjust the cover to make it reset free.
The water supply has not been opened Recheck the water supply.
or not connected firmly.
Ice maker
shuts down Ice maker didn’t be placed horizontally. Adjust the feet to be horizontal.
after operation
High-voltage temperature control switch Open the front panel, clean the
action. condenser.
Open the front panel, clean the
Didn’t clean more than two months .
condenser.
The water temperature is too high
(Usually it happens in summer).
Lack of ice
Clean up the surrounding sundries and
production. The environment temperature is too high. use electric fan to makes the temperature
cool down and the air circulating.
The environment space is small or closed. Clean up the surrounding sundries to
make air circulating.
The water inlet valve fails and keeps open Replace the water inlet valve.
( the water tank is overflowing).
Improper adjustment of ice thickness Reset the ice thickness detector
detector.
The The water quality is poor. Install the filter, replace the filter element.
transparency
of ice cube is The water tank and ice tray is too dirty. Clean the ice maker and replace the
poor or the filter element.
shape of the
ice is The water inlet valve filter screen is dirty. Clean the water inlet valve filter screen.
incomplete.
Large amount of running water above Tighten silicon tube of water pump,
ice tray. regulate water flow.
The drain valve fails and keeps close Replace the drain valve.
( Split ice maker).
The ice cube The ice is too thick. Adjust the Ice thickness.
can not drop
from the ice Clear the probe and check the
tray. The ice detector is dirty and loose.
connection.
The ice maker placed instability, foot
Place the ice maker smoothly.
Excessive hangs in the air.
noises. The shell of the ice maker touch other
Avoid touching other objects.
objects.
The shell of The door of ice storage bin is Completely shut down the ice storage
the ice maker not completely closed. tank.
has condensed Working in a high temperature and humid Normal phenomenon.
water. environment.
-19-
Before calling for service
If the ice maker is abnormal, please confirm the following contents before
making a phone call :
1. Is the water source supply of the ice maker normal?
The method of inspection is to loosen the ice water inlet ( 6” joints )
behind the machine, when loosening to a certain extent, the water will leak
out. The water source supply will be normal when the water is exuded for a
long time, otherwise, there is no water.
2. Whether the ice maker has been connected to the power supply or not?
The ice maker produced by our company is fully automatic without manual
operation. You just need to connect the power supply and open the red
switch on side of the back of the ice maker. Please let the person who
understand the electricity to check whether the ice maker is electrified ,
focus on checking the plug base.
3. Model and series No. of our ice maker.
There is model and series No. nameplate on the side panel of the machine.
Plastic parts of the ice maker do not belong to the scope of warranty.
-20-
Other Language Instruction
The insulating material between the metal shell and the ice storage
bin is combustible polyurethane foaming material. After the
machine is waste, please treat it according to the national or local
regulations on the treatment of combustible waste.
-21-
The instruction is the undivided part of the ice maker.
The user must keep it properly.