0% found this document useful (0 votes)
11 views28 pages

Guia Simetrix

The siMetrix Installation Guidelines provide comprehensive instructions for the installation of various Sikla support frames and components, suitable for applications like frame supports and industrial engineering. The guide emphasizes quick assembly through an innovative click-system and offers technical advice for tailored solutions. It includes detailed product descriptions, assembly instructions, and safety considerations for connecting to building structures.

Uploaded by

Luciano JV
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views28 pages

Guia Simetrix

The siMetrix Installation Guidelines provide comprehensive instructions for the installation of various Sikla support frames and components, suitable for applications like frame supports and industrial engineering. The guide emphasizes quick assembly through an innovative click-system and offers technical advice for tailored solutions. It includes detailed product descriptions, assembly instructions, and safety considerations for connecting to building structures.

Uploaded by

Luciano JV
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 28

siMetrix

Installation Guidelines
Sales Organisation

Sikla GmbH
In der Lache 17
78056 VS-Schwenningen

International Sales
[email protected]
Fon +497720 948 0
www.sikla.com
09/2024

3
Applications

 Frame supports
 Modular construction
 Ceiling supports and ceiling grids
 Roof-mounted units
 Air conditioning and ventilation systems
 Industrial and plant engineering
 Prefabricated modules
 Combination with SiFramo/Siconnect
 Electrical cable routing

Simple and quick installation

 One type of screw for all connections


 The innovative click-system
aides fast assembly
 Installation of intermediate floors
 Flexible construction in production buil-dings
 Realization of complex structures using the
innovative 1-2-3 principle
09/2024

4
siMetrix Installation Guidelines

Area of application

This guide enables the user to easily select suitable application solutions with typical Sikla support frames.

Technical advice

Our customer service representatives and application engineers are happy to provide you with further detailed information –
to answer your questions or to work with you to develop specific solutions using Sikla design software.

Disclaimer

This documentation is intended for the use of the recipient only and is the property of Sikla in all its parts. The technical
representations and all information are given to the best of our knowledge. Illustrations and drawings are non-binding.
Liability for printing errors or defects is excluded.

We reserve the right to make changes and improve the design, particularly in the interests of technical progress.

Product overview

The product range of the siMetrix system can be divided into four different blocks depending on the application, which are
explained separately in this installation manual:

Internal connections / frame constructions 6

Installation to the building structure 13

Pipe connections 19

Combination of systems 23
09/2024

5
siMetrix Installation Guidelines

Internal connections / frame constructions

Profile PRO 46

Material:
Steel, HCP coating
(Corrosion category ≤ C4
according to DIN EN ISO 12944)

PRO 46

46mm

Hole pattern
(only PRO 46-P)
PRO 46-P

46mm
Ø8 mm

Profil with
internal gearing
50mm

The closed shape not only provides high


torsional rigidity but also allows for the
adjustment of connecting parts and pipe support
connections on all four sides without restriction.
11mm

Type Profile Modulus Second Moment of Area Radius of Gyration Area of Section Cut Lengths Z
Wy = 4,12 cm3 Iy = 9,49 cm4 iY = 1,60 cm
PRO 46 3,70 cm2 2m, 6m
Wz = 4,12 cm3 Iz = 9,49 cm4 iz = 1,60 cm Y
Wy = 3,46 cm3 Iy = 7,96 cm4 iY = 1,55 cm
PRO 46 -P 3,33 cm2 2m, 6m
Wz = 4,11 cm3 Iz = 9,45 cm4 iz = 1,68 cm

Precise, continuous
installation can be achieved on
all four sides simultaneously,
without limitation

Quick assembly
system for fastening
pipe clamps and other
components
07/2024

6
siMetrix Installation Guidelines

Connector CN 46 1 The connector is pressed onto the profile.

AF 17 / T50

Click!

2 Then press onto another profile at 90°

Connecting element for frame constructions and


cantilevers. For cantilevers, the connector must
always be used in pairs.

Click!

3 Tighten screw

30 Nm

Once inserted into the profile,


it is self-retaining and can be
easily moved by hand.

The central spring allows the connector to be pressed onto the profile and locked into place.

1 2 3
09/2024

7
siMetrix Installation Guidelines

The closed and symmetrical profile shape enables the adaptation of


connecting parts and pipe support connections on all four sides
without restriction.

Upper traverse shown with one


connector per connection due
to lower static requirements.

1x connector per connection

2x connectors per connection


(use in pairs)

Depending on the impact, one or two connectors must be used per connection
07/2024

8
siMetrix Installation Guidelines

Interlocking
Force and form fit guarantee
optimum safety at the
connection points when
installed correctly

Using the connector, any frame


arrangement can be built
(e.g. roof constructions)

Insulated Foot SHB SQF 46

End Cap ADK 46


Easy
assembly

Material
PE-LD, yellow

End cap for a clean


profile finish.
09/2024

9
siMetrix Installation Guidelines

Profile Coupling PK 46

Self-drilling screws
SKB ST 5,5x16 HCP
200mm

(x8)

35mm

The 8 screws are supplied in a


polybag inside the profile coupling.

Then screw in the screws at


Push the profile the same distance on the
coupling in until opposite sides.
it stops.

2
Symmetrical installation!

max. 170mm

= =

Maintain the largest


possible screw spacing
Push the second profile up to for optimal leverage
the stop and screw it tight. conditions!
07/2024

10
siMetrix Installation Guidelines

Cantilever Bracket AK CC 46-P

ADK 46 Screw
AF 17 / T50
Cantilever Bracket for pipe
or duct mounting on
Profiles PRO 46

CC
Scrope of delivery: installation
fully pre-assembled

Mount the Cantilever


Bracket AK CC 46-P to
the Profile PRO 46

Click!

Place AK CC 46-P at By pressing on the


an angle on the profile two locking parts, the
and hook the rigid Cantilever Bracket is
claw into the profile. locked to the profile.

Slide the Cantilever Bracket to


the desired position and 20 Nm
tighten the screws. (2x)
09/2024

11
siMetrix Installation Guidelines

AK CC 46-P
available lengths

200mm 400mm 600mm 800mm 1000mm

3D constructions

STR 550/350

For cantilever lengths ≥


500 mm, a vertical brace or
support is recommended.

e.g. with tie rod STR and


blockset PBS 46 M10 x 50
Installation possible on all profile
sides without collision.
07/2024

12
siMetrix Installation Guidelines

Installation to the building structure

Connection to steel beam


Assembly with U-Holder SB 46
Connecting element for fastening the
max. beam flange = 30mm
Profile PRO 46 to steel beams facilitating
perpendicular of cantilever connection

min.
50mm

Always use in pairs!

M10

1 2

20 Nm

0 mm !
09/2024

13
siMetrix Installation Guidelines

Arrangement below
steel beams

In all arrangements, the load-bearing capacity of the steel beam must be taken into
account, and torsional stiffness in the case of a cantilevered arrangement.

Connection to
vertical steel beams

SB 46

CN 46

For the determination of load AK CC 46


distribution for horizontal
trusses please see the
siMetrix Static Guideline
07/2024

14
siMetrix Installation Guidelines

Mounting using Joining Plate AP 46

Form-locking connection of adapter plate with AK 46 or WBD 46


using countersunk screws and nuts.

The scope of delivery includes countersunk


screws, nuts and washers.

Beam flange widths


t = 80 mm to 120 mm

AK 46

Force-locking fastening to steel beams using


Assembly Set MS 5P M12 S
(tightening torque = 60 Nm + 90° further rotation angle)

End Support WBD 46 + AP 46


09/2024

15
siMetrix Installation Guidelines

Wall, floor and ceiling connection

Connection via Cantilever Bracket AK 46-P

Connection to the structure


using Bolt Anchors AN BZ plus
or heavy-duty anchors M12. 90mm

When used in conjunction with


Slide Elements, a cross brace is
recommended to absorb
the forces in the axial
direction of the pipe

in combination with:
 Universal Joint UG, Blockset PBS
M10x30 and threaded rod GST M10 HCP
 or alternatively with Tie Rod STR and
Blockset PBS M10x50

Lateral Brace CFB 46 HCP


The Lateral Brace is used to absorb Installation using Profile Clip MPK 46
transverse forces, which are mainly (pre-assembled).
caused by the linear expansion
of hot pipes.

The Lateral Brace can optionally be attached MPK 46 is simply pressed onto
to the concrete wall with two M12 anchors the PRO 46 profile.
to achieve higher load values
07/2024

16
siMetrix Installation Guidelines

Connection via End Support WBD 46

Connection to the
structure using Bolt
Scope of delivery:
Anchors AN BZ
pre-assembled
plus or heavy-duty
anchors M12.

90mm

Screws
AF 17 / T50

Depress both locking sides of the profile intake, insert the The locking
profile and release. mechanism must
engage in the profile 3
grooves. The screws
are then tightened.

20 Nm
2 (4x)

When closing, make


sure that both sides
are pressed together
at the same time
Notice:
(L-sheet connection). Click!
The locking parts must be
pressed open completely. (4x)

U-support
suspended
Elevated
assembly

Assembly examples
09/2024

17
siMetrix Installation Guidelines

Profile Holder MPH PRO 46 W

Connection to the
structure using Bolt
Anchors AN BZ plus or
heavy-duty anchors M12.

Bracket for connecting a


PRO 46 profile.

min.
50mm

Suspended
arrangement of
Vertically mounted pipes on a a pipe traverse.
horizotally attached profile

Insulated Foot SHB SQF 46 Tests to determine the coefficient


Insert the Profile PRO 46 into of friction shall be carried out
the Insulated Foot's slot. by the customer

SQF 350

(max. perm.
pressue load
F = 16kN)

SQF 500
Type t [mm] B [mm]
Suitable for equipment, pipes, t SQF 350 60 350
ventilation ducts or walkways.
SQF 500 90 500
B
07/2024

18
siMetrix Installation Guidelines

Pipe connections

Mainly for use in ducting systems, also for sound proof


SAL 46
installations as per DIN 4109.
Material: SBR/
EPDM, black

GA 41-46
Material:
PA 6.0

PBS CC 46
M8, M10

PBH 46
M6, M8, M10,
M12, M16, 1/2"

MPK 46
Notice: M8, M10,
The point load capacity of the profile must M12, M16
not be exceeded.

Assembly 4
2 PBS CC 46
und PBH 46

15 Nm
Click!
3
1 Notice:
To disassemble, loosen
Hook/insert part the nut and press on the raised
with fixed claw. side of the upper part. The block
can then be removed from the profile.

3
Assembly
MPK 46 15 Nm
Click!

2
1
Push through
the threaded
rod and nuts. Tighten
MPK 46 is simply pressed onto hex nuts.
the PRO 46 profile.
09/2024

19
siMetrix Installation Guidelines

Slide Set GS H3G-PL 46


M16
1/2"
M10

H3G-PL 46

AF 17
/ T50

H3G2-PL 46
Scope of delivery: fully pre-assembled

Click!
2
Press the Slide Set onto the profile
using the pre-assembled
retaining clips.

15 Nm
(2x)
Slide the Slide Set GS
to the desired position. Then tighten the screw
connection of the Profile
Clips (AF 17 or T50).
07/2024

20
siMetrix Installation Guidelines

Connection to the
structure using Bolt
Anchors AN BZ
plus or heavy-duty
anchors M10.

Notice:
For supported
installations from
DN 100 upwards, a
locking nut must be
mounted on the 3G
triple thread nut for
both Slide Sets.

Notice:
Connecting elements must have
sufficient rigidity. For larger
distances, threaded pipes
must be used.

max. lever arm max. glide path


Type
H [mm] s [mm]
H3G-PL 46 500 100
H3G2-PL 46 500 140
09/2024

21
siMetrix Installation Guidelines

U Bolt RUB 46 Scope of delivery: Completely pre-assembled

U Bolt with sheath Slide Support


M8/M10/M12 GA 41-46

MPK 46 (2x) (is simply pressed


onto the PRO 46 profile.)

(2x) nuts on
each side

Guide bearing Fixed point


1

When used as a fixed point, first tighten the lower


nuts until the pipe is clamped.

When used as a guide bearing, nuts arranged on both 2


sides at the top and bottom of the round steel bracket
must be tightened.

GA 41-46: Sound- Then tighten the upper nuts.


absorbing and insulating
pipe support surface For fixed points, the permissible forces of the structural
connection and the bending loads of the U Bolt must
The pipe should remain freely movable. not be exceeded.
07/2024

22
siMetrix Installation Guidelines

Combination of systems

Combination with Siconnect


Channel Adapter SA PRO

Screw CC-46
AF 17 CC-46 Screw
AF 17 assembly
/ T50 assembly
/ T50

Scope of
delivery: fully CC-27
pre-assembled assembly
CC-41
assembly

SA PRO 46 - 41 SA PRO 46 - 27
Combination with Assembly System Pressix CC 41 Combination with Assembly System Pressix CC 27

SA PRO assembly

1 Click!

20 Nm (2x)

Place SA PRO at an angle By pressing on the two Tighten screws


on the profile and hook the locking parts, the SA PRO
rigid claw into the profile. is locked to the profile.

Click!

SA PRO 46-27: 10 Nm
SA PRO 46-41: 40 Nm (2x)
Slide SA PRO to the Then insert the channel, press it
desired position. firmly and tighten the screws.
09/2024

23
siMetrix Installation Guidelines

Cross connection using Profile Holder MPH PRO

Screw
AF 17

MPH PRO
41- 46 1

Click!
(CC-41)
Scope of delivery:
pre-assembled in a
set with 2x Speed Nut

40 Nm (2x)
2

Click!
1 (CC-46)

MPH PRO
46 - 41

pre-assembled
in a set with 2x
Blockset

2 15 Nm (2x)
07/2024

24
siMetrix Installation Guidelines

Combination with SiFramo

Cross connection using Profile Holder MPH F 80/F 100 - 46

available for Beam


Section TP F 80
and TP F 100

60 Nm
(4x)

Form-fitting connection to
Beam Section TP F using 4
Self Forming screws FLS F

Profile Adapter MPA F 80/F 100 - 46


2 Press the four locking
parts onto the profile.
Scope of delivery:
fully pre-assembled Form-fitting
connection to the
Beam Section TP F
using 4 Self Forming
Screws Screws FLS F.
AF 17 / T50

available for Beam


Section TP F 80 and
TP F 100
Click!
1 (4x)
Press the locking parts together and insert
the PRO 46 profile into the profile intake. Tighten 4
3
screws.

60 Nm
(4x)

Notice: 20 Nm
The locking parts must be (4x)
pressed open completely.
09/2024

25
siMetrix Installation Guidelines

Combination of Sikla systems: Assembly examples

MPH
F 80 - 46

MPH PRO MPA


41 - 46 F 80 - 46

SA PRO
41 - 46
07/2024

26
Art-Nr. 806168

You might also like