Preface
Overview 1
Safety instructions 2
SIMATIC HMI
Security 3
HMI devices
Smart 700 IE V5, Smart 1000 IE V5 4
Mounting and connecting
Commissioning a project 7
Technical specifications 9
Technical Support B
Abbreviations C
01/2025
A5E53807433-AA
https://365electricalvn.com/category/automation-manual/
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens Aktiengesellschaft. The remaining trademarks in
this publication may be trademarks whose use by third parties for their own purposes could violate the rights of
the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
https://365electricalvn.com/category/automation-manual/
Preface
The WinCC flexible SMART online help contains additional information. The online help
contains instructions, examples and reference information in electronic form.
Scope
These operating instructions apply to the following Smart HMI devices:
Note
The firmware version must be V5.0.0.0 and later versions.
https://365electricalvn.com/category/automation-manual/
Preface
Note
A note contains important information on described products and their handling or on a
section of this documentation.
Trademarks
Names labeled with a ® symbol are registered trademarks of the Siemens AG. Other names
used in this documentation may be trademarks, the use of which by third parties for their
own purposes could violate the rights of the owner.
• HMI®
• SIMATIC®
• SIMATIC HMI®
• WinCC®
• SIMICAS®
History
Edition Comment
01/2025 First Edition
https://365electricalvn.com/category/automation-manual/
Table of contents
Preface ................................................................................................................................................... 3
1 Overview.............................................................................................................................................. 11
1.1 Product description ............................................................................................................ 11
1.2 Design of the HMI devices .................................................................................................. 13
1.3 Scope of delivery ............................................................................................................... 14
1.4 Accessories ........................................................................................................................ 14
2 Safety instructions ............................................................................................................................... 15
2.1 General safety instructions ................................................................................................. 15
2.2 Notes about usage ............................................................................................................. 16
3 Security ................................................................................................................................................ 19
3.1 Cybersecurity information .................................................................................................. 19
3.2 Data protection.................................................................................................................. 19
3.3 User access model ............................................................................................................. 21
3.4 Secure decommissioning ................................................................................................... 21
3.4.1 Securely removing data ..................................................................................................... 22
3.4.2 Recycling and disposal ....................................................................................................... 23
3.5 IoT certification.................................................................................................................. 23
3.6 Secure communication ...................................................................................................... 24
4 Mounting and connecting ................................................................................................................... 25
4.1 Preparations ...................................................................................................................... 25
4.1.1 Checking the package contents .......................................................................................... 25
4.1.2 Checking the operating conditions ..................................................................................... 25
4.1.3 Selecting a mounting position ............................................................................................ 25
4.1.4 Checking clearances .......................................................................................................... 27
4.1.5 Making the mounting cutout ............................................................................................. 27
4.2 Mounting the HMI device ................................................................................................... 29
4.3 Connecting the HMI device ................................................................................................ 31
4.3.1 Connection sequence ........................................................................................................ 31
4.3.2 Connecting the equipotential bonding circuit ..................................................................... 32
4.3.3 Connecting the power supply............................................................................................. 34
4.3.4 Connecting the configuration PC ........................................................................................ 35
4.3.5 Connecting the PLC or other field devices ........................................................................... 36
4.3.6 Connecting a USB device, micro SD card ............................................................................. 38
4.4 Installing SMART LINE IoT module ...................................................................................... 39
4.5 Switching on and testing the HMI device ............................................................................ 41
https://365electricalvn.com/category/automation-manual/
Table of contents
https://365electricalvn.com/category/automation-manual/
Overview 1
1.1 Product description
Smart IE V5 HMI device provides optimal choices and high-level functionality for small
automation systems.
Stronger hardware
• Equipped with high-performance dual-core CPU
• Extend RTC power-off retention up to 3 years
Enhanced capability
• Support extension IoT modules: 4G module, Wi-Fi module
• Support SIMICAS IoT connection for remote access and data maintenance
• Support JavaScript programming
• Support Freeport protocol communication
Seamless compatibility
• Seamless compatible with Smart Panel V4 mounting cutout for smooth project migration
https://365electricalvn.com/category/automation-manual/
Overview
1.2 Design of the HMI devices
The Ethernet port can be configured via the Control Panel or the WinCC flexible SMART
software.
The RS 422/485 port is configured via the WinCC flexible SMART software.
1.4 Accessories
Accessories are not included in the HMI device scope of delivery, but can be ordered on the
Internet under Industry Mall (http://mall.industry.siemens.com).
https://365electricalvn.com/category/automation-manual/
Safety instructions 2
2.1 General safety instructions
NOTICE
The HMI device is approved for indoor use only.
The HMI device may be damaged if it is operated outdoors.
Operate the HMI device indoors only.
WARNING
The device constitutes open equipment on the back side
The device constitutes open equipment on the back side. This means that the device may
only be integrated in an enclosure or cabinet which provides front access for operating the
device. The enclosure, the cabinet or the electrical operating rooms must provide protection
against electric shock and the spread of fire. The requirements regarding the mechanical
strength must also be considered.
Access to the enclosure or cabinet in which the device is installed should only be possible by
means of a key or tool and for trained and qualified personnel.
Dangerous voltage
Opening the cabinet will expose high voltage parts. Contact with these parts could be fatal.
Must disconnect the cabinet from the mains before opening it.
Note
Unwanted operating states
High-frequency radiation, for example, from cellular phones, can trigger unwanted operating